1.
Chinese Journal of Radiation Oncology ; (6): 546-550, 2023.
Artículo en Chino | WPRIM | ID: wpr-993228

RESUMEN

Objective:To analyze the correlation between the monitor units and pass rate of plan dose verification in the volumetric intensity modulated arc therapy (VMAT) plan.Methods:VMAT plans for 20 patients with nasopharyngeal carcinoma (NPC) and 30 patients with cervical cancer who underwent radiotherapy at Liuzhou Workers' Hospital from January to October 2020 were retrospectively chosen. The Detector 1500 array and Octavius 4D phantom from German PTW company were used for dose measurement. The pass rates of dose verification of relevant plans were analyzed under the conditions of 3%/2 mm and 2%/2 mm. The correlation between the monitor units and pass rate of plan dose verification in VMAT plans was assessed by Pearson's bivariate correlation analysis.Results:Under the condition of 3%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.873 ( P<0.001), -0.800 ( P<0.001), -0.781 ( P<0.001), -0.493 ( P=0.006) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Under the condition of 2%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.842 ( P<0.001), -0.770 ( P<0.001), -0.748 ( P<0.001) and -0.531 ( P=0.003) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Conclusion:Significant negative correlation can be observed between the monitor units and plan dose verification pass rate in VMAT plan.

2.
Chinese Journal of Radiological Medicine and Protection ; (12): 609-613, 2019.
Artículo en Chino | WPRIM | ID: wpr-755017

RESUMEN

Objective To investigate the efficacy of concurrent chemoradiotherapy for anal squamous cell carcinoma (ASCC) in the era of intensity-modulated radiotherapy.Methods A total of 19 patients with ASCC who underwent definitive radiotherapy in our hospital since 2011 were collected.The survival curves were depicted with K-M method.Risk factors of disease progression were analyzed using case-control study.Results The median follow-up time was 31 months.The 3 year-LFS and 3 year-OS were 88.1% and 91.7%,respectively.Grade 3 acute toxicities during the chemoradiotherapy were mainly white blood cell reduction (15.8%),platelet reduction (10.5%),diarrhea (15.8%),and skin reaction (31.6%).Compared with historical data,volumetric intensity modulated arc therapy was superior to conventional radiotherapy in the treatment outcome and normal tissue protection in ASCC.Univariate analysis showed that concurrent chemotherapy with capecitabine was a favorable factor in disease progression (P< 0.05).Conclusions Volumetric intensity modulated arc therapy for ASCC may have advantages in terms of efficacy and normal tissue protection.Concurrent chemotherapy with a double-drug regimen containing capecitabine may be a beneficial factor in disease progression.

3.
Chinese Journal of Radiological Medicine and Protection ; (12): 832-837, 2017.
Artículo en Chino | WPRIM | ID: wpr-663165

RESUMEN

Objective To compare the dosimetric differences in heart and lung among three radiotherapy techniques in the treatment of thoracic esophageal cancer. Methods A total of 15 thoracic esophageal cancer patients treated in Zhejiang Cancer Hospital during the period of January 2015 to February 2016 were enrolled in this retrospective dosimetric study. Three radiotherapy treatment plans, including intensity-modulated radiotherapy ( IMRT) , volumetric intensity modulated arc therapy ( VMAT) with Raystation 4. 0v TPS, and tomotherapy (TOMO) plans with TomoTTM v2. 0. 5 TPS were generated for each patient with a prescribed dose of 60 Gy at 2 Gy per fraction. Dosimetric differences in planning target volume ( PTV) , heart, cardiac subunits and lung were compared. Results The mean volumes of PTV, heart and lung were (399 ±355), (671 ±274) and (3907 ±1717)cm3, respectively. Compared with VMAT and IMRT, TOMO reduced the maximum dose of PTV, heart, left atrium and lung ( H=10. 889, 7. 433, 12. 080, 11. 401, P <0. 05). No difference was observed in conformity or homogeneity among these three plans. Conclusions TOMO reduced the maximum dose to PTV, heart, left atrium and lung compared with VMAT and IMRT, However, no difference in conformity and homogeneity was observed. The impact of dosimetric advantage of TOMO needs further verification due to the interaction between heart and lung for thoracic esophageal cancer patients.

4.
Chinese Journal of Radiation Oncology ; (6): 929-933, 2017.
Artículo en Chino | WPRIM | ID: wpr-617759

RESUMEN

Objective To investigate the gamma (γ) passing rates for volumetric-modulated arc therapy (VMAT) dosimetric verification with different techniques.Methods A total of 12 VMAT plans for the treatment of different anatomical sites in cancer patients were chosen.The Octavius 4D system was used to measure the dose distributions in two different settings:the gantry was rotating (three-dimensional (3D) and 2D γ-analysis) and the gantry was fixed at 0°(2D γ-analysis).The γ passing rates were analyzed with 3%/3 mm and 2%/2 mm criteria, using the paired t test or Wilcoxon signed-rank test.The 2D γ passing rates for different irradiation methods were calculated.Results For the 3D and 2D dose distributions obtained at a rotating gantry angle as well as the 2D dose distribution obtained at zero gantry angle, the average γ passing rates were 96.03%, 96.98%, and 98.90% for 3%/3 mm (P=0.227, P=0.000, P=0.003);82.08%, 84.04%, and 90.90% for 2%/2 mm (P=0.379, P=0.000, P=0.000).For the 2D dose distributions obtained with different irradiation methods, the average γ passing rate was 98.99% for 3%/3 mm and 93.68% for 2%/2 mm.Conclusions The VMAT dosimetric verification based on a 3D volumetric dosimeter at a rotating gantry position can be clinically useful for delivery quality assurance (QA), and can achieve the most reliable dose calculation for VMAT, which has more referential values.

5.
Chinese Journal of Radiation Oncology ; (6): 550-553, 2012.
Artículo en Chino | WPRIM | ID: wpr-430126

RESUMEN

Objective To develop an accurate 2D dose reconstruction model using electronic portal imaging device (EPID).2D dosimetric verifications of volumetric intensity-modulated arc therapy (VIMAT)were done using the model.And the results were compared to other dosimeters.Methods The EPID-based dose reconstruction model was using convolve,deconvolve and correction function.The dose profiles which were obtained by the ion chamber were used to determine the model parameters.A total of 12 VIMAT plans for the treatment of anatomical sites of various complexities were chosen.The results obtained from EPID were compared to other dosimeters and treatment planning system (TPS).The ion chamber was used to measure the central point absolute doses.Other dosimeters were used to measure the plane dose distributions.All dosimeters measured the dose at 10 cm depth.The results were analyzed using γevaluation method.Results Regarding absolute central point doses,the ion chamber results were within 1.5% of the EPID results.For the comparison to Seven29 and Matrixx,the average γ pass rates with 2%and 2 mm criteria were 98.9% and 99.8% respectively.For the dose distributions measured by EPID and calculated by TPS,the γ pass rates with 3% and 3 mm criteria were 99.9%.Conclusions The presented results which were obtained from the comparison of measured and calculated doses show the reliability of our EPID-based dose reconstruction model.With the model,EPID can be a reliable and fast tool for IMRT plan dosimetric verification.The model expanded to the 3D dosimetric verification in the uniform phantom will be considered as the next work.