Annals of Laboratory Medicine ; : 244-249, 2016.
Artículo en Inglés | WPRIM | ID: wpr-56702

RESUMEN

We established age- and gender-specific reference ranges for the 36 routine complete blood cell (CBC) and 57 cell population data (CPD) items in the Sysmex XN-2000 (Sysmex, Japan). In total, 280 peripheral blood samples were obtained from an equal number of healthy adults. Values for 36 routine items and 57 CPD items were obtained for each sample, and the results were categorized into six subgroups (N>39 in each subgroup) according to patient age (20-40, 41-60, and >60 yr) and gender (male and female), and compared with respect to age and gender differences. The majority of data items (22 of 36 routine CBC items and 44 of 57 CPD items) exhibited significant differences (P< or =0.05) in their results with respect to age or gender, and several red cell-, lymphocyte-, and platelet-related data tended to decrease in women or older adults. These results provide a basis for establishing age- and gender-specific reference ranges for routine and CPD items in Sysmex XN-2000. Furthermore, these reference ranges could be used to determine clinical significance for new items of Sysmex XN-2000 in further studies.


Asunto(s)
Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Factores de Edad , Automatización , Recuento de Células Sanguíneas/métodos , Valores de Referencia , Factores Sexuales
2.
Laboratory Medicine Online ; : 188-195, 2015.
Artículo en Coreano | WPRIM | ID: wpr-55298

RESUMEN

BACKGROUND: The XN-series (Sysmex, Japan) is the new hematology analyzer from Sysmex, with new channels to improve the accuracy of differential leukocyte count and platelet count in the low cell count range. We evaluated the analytical performance and low white blood cell (WBC) mode of the XN-2000. METHODS: Precision, linearity, and carryover were evaluated for the analyzer. We analyzed the accordance of complete blood count (CBC), reticulocyte count, and differential leukocyte count between the XN-2000 and XE-2100 (Sysmex), using 200 samples from normal controls and patients. For 80 samples with a WBC count 0.9800 for all CBC parameters except mean corpuscular hemoglobin concentration, mean platelet volume, and platelet distribution width, and >0.9900 for differential leukocyte count except monocytes and basophils. The low WBC mode provided accurate counts for neutrophils and lymphocytes, with r>0.9300 for samples with a WBC count of 0.1-1.5x10(9) cells/L. CONCLUSIONS: The XN-2000 showed good analytical performance and correlation with the existing model, the XE-2100. The XN-2000 provided accurate results for differential leukocyte count in samples with a WBC count of 0.1-1.5x10(9) cells/L, and reduced manual slide reviews.


Asunto(s)
Humanos , Basófilos , Recuento de Células Sanguíneas , Plaquetas , Recuento de Células , Índices de Eritrocitos , Hematología , Recuento de Leucocitos , Leucocitos , Linfocitos , Volúmen Plaquetario Medio , Monocitos , Neutrófilos , Recuento de Plaquetas , Recuento de Reticulocitos