Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Medical Instrumentation ; (6): 304-308, 2023.
Artículo en Chino | WPRIM | ID: wpr-982233

RESUMEN

Implanted brain-computer interface (iBCI) is a system that establishes a direct communication channel between human brain and computer or an external devices by implanted neural electrode. Because of the good functional extensibility, iBCI devices as a platform technology have the potential to bring benefit to people with nervous system disease and progress rapidly from fundamental neuroscience discoveries to translational applications and market access. In this report, the industrialization process of implanted neural regulation medical devices is reviewed, and the translational pathway of iBCI in clinical application is proposed. However, the Food and Drug Administration (FDA) regulations and guidances for iBCI were expounded as a breakthrough medical device. Furthermore, several iBCI products in the process of applying for medical device registration certificate were briefly introduced and compared recently. Due to the complexity of iBCI in clinical application, the translational applications and industrialization of iBCI as a medical device need the closely cooperation between regulatory departments, companies, universities, institutes and hospitals in the future.


Asunto(s)
Humanos , Interfaces Cerebro-Computador , Encéfalo/fisiología , Electrodos Implantados
2.
Chinese Journal of Medical Instrumentation ; (6): 94-98, 2019.
Artículo en Chino | WPRIM | ID: wpr-772556

RESUMEN

In the electromagnetic compatibility standards of active implantable medical devices such as ISO 14117,radiated immunity test above 450 MHz frequency is recommended to be carried out in the electromagnetic shielding room.However,different test locations and the shape/size of the shielding room may lead to very different electromagnetic field distribution in the radiation exposure area of the sample,thus affecting the consistency of the test.With the model built by COMSOL software,this paper analyzes the impact of different parameters,such as size of the room and position of torso simulator on the distribution of field intensity,and reaches results about the distribution of field intensity on the torso simulator area under tow sizes of shielding rooms and two typical test positions.The results show that the experimental consistency of the electric field intensity on the surface directly below the center of the antenna is not good enough,which may affect the repeatability of the test.


Asunto(s)
Campos Electromagnéticos , Prótesis e Implantes
3.
Chinese Journal of Medical Instrumentation ; (6): 170-172, 2018.
Artículo en Chino | WPRIM | ID: wpr-689841

RESUMEN

In order to compare the radiation immunity test level of ISO 14708 series standards and the domestic and international environmental radiation standards and then to ascertain whether the radiated immunity test level has reached the limit of the radiation strength in the relevant radiation environmental standards, this paper calculated the radiation field intensity and power density according to the radiated immunity test of ISO 14708 standards, and compared with the limit of ICNIRP 1998 and GB 8702-2014.


Asunto(s)
Campos Electromagnéticos , Radiación Electromagnética , Inmunidad , Prótesis e Implantes , Dosis de Radiación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA