Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Añadir filtros








Intervalo de año
1.
Journal of Southern Medical University ; (12): 128-132, 2023.
Artículo en Chino | WPRIM | ID: wpr-971505

RESUMEN

OBJECTIVE@#To explore the application of extended reality (XR) technology in clinical surgeries for improving the success rate of surgeries.@*METHODS@#To assist the surgeons to better understand the location, size and geometric shape of the lesions and reduce potential radiation exposure in minimally invasive surgical navigation based on two-dimensional images, we constructed three-dimensional models based on CT data and used XR technology to achieve intraoperative navigation. An improved quaternion method was used to improve the accuracy of electromagnetic positioning, with which the system error of positioning accuracy was reduced to below 2 mm. A 5G network was used to optimize the server GPU programming algorithm, and real-time video stream coding strategy and network design were adopted to reduce data transmission jam and delay in the remote surgery network, which achieved an average delay of less than 60 ms. A Gaussian distribution deformation model was used to simulate collision detection and stress deformation of the tissues to achieve a tactile perception effect.@*RESULTS AND CONCLUSION@#The intraoperative navigation system based on XR technology allowed more accurate determination of the location of the lesions, effectively reduced the surgical risk, and avoided the risk of intraoperative radiation exposure. The low latency and high fidelity of 5G network achieved real-time interaction during the surgery to provide a technical basis for multi-terminal remote cooperative surgery. The combination of force feedback technology and XR technology enables the surgeons to conduct deep immersion preoperative planning and virtual surgery to improve the success rate of surgery and shorten the learning curve.


Asunto(s)
Algoritmos , Tecnología
2.
Chinese Journal of Medical Education Research ; (12): 367-370, 2019.
Artículo en Chino | WPRIM | ID: wpr-744189

RESUMEN

For provincial children's hospitals and children's hospitals affiliated to medical colleges and universities with a high level of the diagnosis and treatment,they are the center of referral and need to retain pediatricians and build a high-level team of pediatricians.With the authors' own experience in Cincinnati Children's Hospital Medical Center in the US,this article briefly introduces the current clinical operation mode in American children's hospitals,especially the consultation system mainly composed of attending physicians and the mode of continuing medical education based on both clinical and scientific research.Such experience provides a reference for pediatricians in China.

3.
Chinese Medical Equipment Journal ; (6): 17-20, 2017.
Artículo en Chino | WPRIM | ID: wpr-662377

RESUMEN

Objective To develop a laser positioning device for GE OEC850 and Wandong HMC-36 C-arm.Methods The device was composed of two cross-type laser tubes,timing circuit and power source.The optimal 30 cm projection point was determined with laser dual-crossed-line positioning method and considerations on the distance between the tube of GE OEC850 or Wandong HMC-36 C-arm and the image intensifier.Then the projection range was found around 30 cm to define the targeted area.Results The device eliminated the needs of multi times of projection due to improper positioning,decreased the exposure to medical personnel and patient during the operation,prolonged the service life of the tube and reduced the cost for hospital equipment.Conclusion The device behaves well in positioning and easy operation,and thus is worthy promoting clinically.

4.
Chinese Medical Equipment Journal ; (6): 17-20, 2017.
Artículo en Chino | WPRIM | ID: wpr-659915

RESUMEN

Objective To develop a laser positioning device for GE OEC850 and Wandong HMC-36 C-arm.Methods The device was composed of two cross-type laser tubes,timing circuit and power source.The optimal 30 cm projection point was determined with laser dual-crossed-line positioning method and considerations on the distance between the tube of GE OEC850 or Wandong HMC-36 C-arm and the image intensifier.Then the projection range was found around 30 cm to define the targeted area.Results The device eliminated the needs of multi times of projection due to improper positioning,decreased the exposure to medical personnel and patient during the operation,prolonged the service life of the tube and reduced the cost for hospital equipment.Conclusion The device behaves well in positioning and easy operation,and thus is worthy promoting clinically.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA