Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Artículo en Inglés | IMSEAR | ID: sea-178101

RESUMEN

Context: Castability has been found to be affected by many aspects of the entire casting system. Very few references in dental literature are available regarding recasting of the base metal alloys. Aims: To evaluate and compare the castability of fresh and reused nickel‑chromium alloy and to evaluate the effect of two brands of investment materials on castability of nickel‑chromium alloy. Subjects and Methods: For the experimental purpose of evaluation of the effect of recasting of nickel‑chromium alloy on its castability, different percentages of new and casted alloy (Nickel‑chromium alloy‑(Wirolloy NB, Type 4 (Ni‑67%; Cr‑25%; Mo‑5%; Si‑1.5%; Mn, Nb, B, C each <1%) and two commercial brands of investment materials namely, Deguvest Impact (Degudent; Dentsply Germany) and Bellavest SH (Degudent; Dentsply Germany) was used to obtain 30 samples. Castability value was obtained using Whitlock’s formula. Student t-test and one way ANOVA using SPSS 20.0 software was done. Results: The results of this study confirm earlier works that demonstrate that there is no significant difference in castability values of new and recast alloys. In addition, it also demonstrated, there was no difference in castability using Deguvest Impact and Bellavest SH investment materials. Conclusions: Within the limitations of the study, it was concluded that there was no significant difference found in castability of different percentage combinations of new and once casted alloy using two investment materials. The addition of new alloy during recasting to maintain the castability of nickel‑chromium alloy may therefore not be required.

2.
J. appl. oral sci ; 17(5): 467-475, Sept.-Oct. 2009. ilus, graf, tab
Artículo en Inglés | LILACS | ID: lil-531399

RESUMEN

OBJECTIVES: As the choice of suprastructure alloy to be combined with titanium for the oral cavity is still a much debated issue, the aim of this study was to investigate the electrochemical interaction of the suprastructure/implant couples under the determined experiment conditions. MATERIAL AND METHODS: The potentiodynamic polarization curves and open-circuit potentials (OCP) of four UCLA type suprastructures coupled with straight Swiss Plus implant fixtures were taken in Afnor type artificial saliva solution at 37°C. The concentration of ions leached into artificial saliva solutions was estimated with ICP-MS. SEM images of the margins of suprastructure/implant couples were obtained before and after the electrochemical tests. RESULTS: The OCP value of titanium became passive at the most negative potential. The lowest difference between the initial and constant OCP value was exhibited by the Au based suprastructure. Suprastructures made greater contributions to the potentiodynamic polarization curves of the implant/suprastructure couples. According to the ICP-MS results, Pd based and Au based couples dissolved less than Co-Ni based and Co-Cr based couples. CONCLUSIONS: Within the conditions this study, it may be concluded that the titanium implant forms a stable passive oxide layer in artificial saliva exposed to open air and does not affect the corrosion properties of the suprastructures. Pd based and Au based couples have been found to be more corrosion-resistant than base alloy couples.


Asunto(s)
Humanos , Implantes Dentales , Aleaciones Dentales/química , Revestimiento para Colado Dental/química , Materiales Dentales/química , Titanio/química , Fenómenos Químicos , Corrosión , Aleaciones de Cromo/química , Técnicas Electroquímicas , Aleaciones de Oro/química , Espectrometría de Masas , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Oxidación-Reducción , Polarografía , Potenciometría , Paladio/química , Solubilidad , Propiedades de Superficie , Saliva Artificial/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA