World Science and Technology-Modernization of Traditional Chinese Medicine ; (12): 1813-1817, 2015.
Artículo en Chino | WPRIM | ID: wpr-481389

RESUMEN

This study was aimed to establish an HPLC method for the content determination ofepimedin A, epimedinB,epimedinC,epimedium glycoside,baohuosideI in epimedium flavonoids capsule. The elusion was performed on an Eclipse Plus C18column (250 mm× 4.6 mm, 5μm). The mobile phase was composed of acetonitrile and water with a gradient elution. The flow rate was set at 1 mL·min-1. The detection wave length was set at 270 nm. The column temperature was 25℃. The results showed that the linear ranges of epimedin A,epimedinB,epimedinC,epimedium glycoside,baohuosideI were 3.10-62.00μg·mL-1, 5.70-114.00μg·mL-1, 9.14-182.80μg·mL-1, 15.20-304.00μg·mL-1, and 1.56-31.20μg·mL-1, respectively. The correlation coefficientr was more than 0.999 3. The average recoveries were 101.06% (RSD = 1.05%,n = 6), 100.78% (RSD = 1.08%,n = 6), 99.17% (RSD = 1.14%,n = 6), 100.23% (RSD = 0.68%,n = 6), and 99.09% (RSD = 1.30%,n = 6), respectively. This experiment was precise, reproducible and stable. It was concluded that the method was simple and accurate, which provided a certain reference value for the multi-component assaying of epimedium flavonoids capsule.