Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Añadir filtros








Intervalo de año
1.
Acta Pharmaceutica Sinica ; (12): 1293-1300, 2023.
Artículo en Chino | WPRIM | ID: wpr-978681

RESUMEN

A hydrophilic interaction chromatography tandem mass spectrometry method was developed for simultaneous quantification of 35 components in gualoupi injection. The analytes were separated with an ACQUITY XBridge Amide column using 20 mmol·L-1 ammonium formate aqueous solution (pH 3.0) as mobile phase A and 20 mmol·L-1 ammonium formate (pH 3.0)∶acetonitrile (1∶9) as mobile phase B for gradient elution. Mass spectrometry with dynamic multiple reaction monitoring and external standard method were used for quantitative analysis. A total of 35 components were determined in 10 batches of gualoupi injection. The results showed that the 35 compounds had a good linear relationship within their respective concentration ranges with the correlation coefficients (R2 > 0.998 0), the recoveries ranged from 76.6% to 118.5%. The results showed that γ-aminobutyric acid, trigonelline, alanine, threonine, homoserine, citrulline, and leucine were abundant in gualoupi injection, while nicotinamide, methylsuccinic acid, cytosine and choline account for a low percentege. The present study provides an important reference for elucidation of the effective material basis and the improvement of quality standard of gualoupi injection.

2.
Acta Pharmaceutica Sinica ; (12): 3621-3625, 2022.
Artículo en Chino | WPRIM | ID: wpr-964315

RESUMEN

An analytical method was developed for determination of 7 aminoglycosides antibiotics in bear bile powder by hydrophilic interaction liquid chromatography tandem mass spectrometry. The samples were purified by mix-mode weak cation exchange and reversed-phase SPE. Waters ACQUITY UPLC BEH Amide column (100 mm × 3.0 mm, 1.7 μm) was used with 0.2% formic acid aqueous solution-0.2% formic acid acetonitrile solution as mobile phases by gradient elution. The aminoglycosides were detected by electrospray ionization mass spectrometry in positive mode with multiple reaction monitoring (MRM) mode. Spectinomycin, streptomycin, amikacin, kanamycin, tobramycin, apramycin and neomycin possessed good linear correlation in the respective concentration ranges, with the correlation coefficients more than 0.99. The mean recoveries at 3 spiked levels were in the range of 61.3%~127.3%, and the RSDs were 0.1%~1.9%. The limits of quantification were 0.2~1.0 mg·kg-1. The method had been applied to the analysis of actual samples.

3.
Chinese Journal of Analytical Chemistry ; (12): 1611-1616, 2014.
Artículo en Chino | WPRIM | ID: wpr-460117

RESUMEN

Anultra-performancehydrophilicinteractionliquidchromatography-triplequadrupolemass spectrometric ( UPLC-MS/MS) method was developed for the determination of tetrodotoxin ( TTX) in human urine and plasma. After the sample was cleaned-up and concentrated by immunoaffinity column, the separation of the TTX was carried out on an Acquity UPLC BEH amide column (100 mm×2. 1 mm, 1. 7 μm) with gradient elution using mobile phases of 0. 1% ( V/V) formic acid in water and acetonitrile. The analyte was detected by positive electrospray ionization mass spectrometry in the multiple reaction monitoring ( MRM) mode, and quantified by external solvent standard calibration. The measuring ranges of TTX in urine and plasma were 0. 05-400 μg/L. The average recoveries were 92%-95% and 91%-96% for TTX respectively spiked in urine and plasma with relative standard deviations of 3 . 3%-7 . 2% and 3 . 9%-7 . 8% ( n=5 ) . The limits of detection (LOD, S/N=3) and limits of quantitation (LOQ, S/N=10) of TTX were 0. 02 μg/L and 0. 05μg/L for urine and plasma, respectively. This method is suitable for the detection of TTX in urine and plasma for both forensic and clinical purposes.

4.
Chinese Journal of Analytical Chemistry ; (12): 1829-1833, 2009.
Artículo en Chino | WPRIM | ID: wpr-404810

RESUMEN

A rapid method for the detection of tetrodotoxin(TTX) in human plasma and urine was developed by hydrophilic interaction liquid chromatography-tandem mass spectrometry. After a simple protein precipitation step was undertaken, the subsequent analysis of TTX was achieved on a TSK-gel amide-80 column using an ammonium formate-methanol-acetonitrile gradient with a cycle time of 13 min, and detected by positive electrospray ionization tandem mass spectrometry in the MRM mode, and quantified by matrix-match standard solution. It was found that linearity in urine was observed within concentration ranged from 3 μg/L to 500 μg/L, that in plasma 1 μg/L to 200 μg/L and that limits of detection(S/N=3) for urine and plasma were 1 and 0.3 μg/L, respectively. The average recoveries were 96%-108% and 100%-105% for TTX spiked in urine and plasma, respectively, with relative standard deviations of 1.7%-8.6% and 8.9%-16%(n=6). This method was simple, selective and sensitive to detect TTX in urine and plasma for both clinical and forensic purposes.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA