Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Ginecol. obstet. Méx ; 90(11): 893-900, ene. 2022. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1430416

RESUMEN

Resumen OBJETIVO: Comparar la eficacia del misoprostol intravaginal con el dispositivo vaginal de liberación prolongada de dinoprostona en la inducción del parto. Además, analizar el perfil de seguridad en relación con los desenlaces maternos y perinatales. MATERIALES Y MÉTODOS: Estudio retrospectivo y comparativo efectuado en pacientes atendidas entre 2018 y 2020 en el Área Sanitaria de Ferrol, La Coruña, España, con partos que se iniciaron con inducción con prostaglandinas. Las pacientes se dividieron en dos cohortes, en función de la prostaglandina sintética administrada (misoprostol por vía vaginal o dinoprostona en dispositivo intravaginal). Para la comparación entre ambos grupos se aplicó la prueba U de Mann-Whitney. Para las variables cualitativas se describió su cantidad total y el porcentaje, que se compararon con prueba de χ2 de Pearson. RESULTADOS: Se analizaron 508 pacientes con inducción del parto. En las indicaciones de ésta no se encontraron diferencias entre uno y otro grupo, aunque destacó la indicación del misoprostol en pacientes con embarazo cronológicamente prolongado (63%) y de dinoprostona en rotura prematura de membranas (49%). En relación con los desenlaces perinatales, se registró un Apgar menor de 7 a los 5 minutos en 2 pacientes tratadas con dinoprostona y 1 con misoprostol; así como un pH arterial umbilical menor de 7.10 en 8 pacientes tratadas con dinoprostona y 7 con misoprostol. CONCLUSIONES: Los datos aquí reportados hacen suponer que ambas prostaglandinas consiguen una tasa de inicio del parto similar, aunque la dinoprostona parece reducir el tiempo hasta el inicio del parto en mujeres con indicación de inducción.


Abstract OBJECTIVE: To compare the efficacy of intravaginal misoprostol with the dinoprostone extended-release vaginal device in labor induction. In addition, to analyze the safety profile in relation to maternal and perinatal outcomes. MATERIALS AND METHODS: Retrospective and comparative study performed in patients attended between 2018 and 2020 in the Health Area of Ferrol, La Coruña, Spain, with deliveries that were initiated with prostaglandin induction. The patients were divided into two cohorts, depending on the synthetic prostaglandin administered (misoprostol vaginally or dinoprostone in intravaginal device). The Mann-Whitney U test was used to compare the two groups. For qualitative variables, the total number and percentage were described and compared with Pearson's 2 test. RESULTS: A total of 508 patients undergoing labor induction were analyzed. No differences were found in the indications for induction of labor between one group and the other, although the indication for misoprostol in patients with chronologically prolonged pregnancy (63%) and for dinoprostone in premature rupture of membranes (49%) stood out. In relation to perinatal outcomes, an Apgar of less than 7 at 5 minutes was recorded in 2 patients treated with dinoprostone and 1 with misoprostol; as well as an umbilical arterial pH of less than 7.10 in 8 patients treated with dinoprostone and 7 with misoprostol. CONCLUSIONS: The data reported here suggest that both prostaglandins achieve a similar rate of onset of labor, although dinoprostone appears to reduce the time to onset of labor in women indicated for induction.

2.
Ginecol. obstet. Méx ; 88(3): 139-145, ene. 2020. tab, graf
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1346168

RESUMEN

OBJETIVO: Determinar la frecuencia y correlación de las episiotomías y desgarros en pacientes con parto eutócico. MATERIALES Y MÉTODOS: Estudio observacional y retrospectivo efectuado en el Hospital General Universitario de Alicante en dos periodos: 1) 2008-2012 y 2) 2013-2018. Se incluyen los partos eutócicos de embarazos únicos, a término, en presentación cefálica. Variables de estudio: episiotomía, desgarro, edad, semanas de embarazo, paridad, inducción del parto, cesárea anterior, analgesia regional, peso y sexo del recién nacido. Los resultados se expresan en porcentaje, coeficiente de correlación y las variables implicadas con razón de momios (RM). RESULTADOS: La tasa de episiotomía entre el periodo 1 vs el 2 disminuyó de manera muy importante: de 42.3 a 32.8%; [p < 0.001; RM: 0.81 (0.78-0.84)]. En cambio, el porcentaje de desgarros aumentó: de 42.7 a 50.8%; (p < 0.001; RM: 1.16[1.13-1.20]). El coeficiente de correlación fue de -0.91. Uno de los factores de riesgo asociados con la episiotomía fue la edad menor de 35 años, con RM de 1.25; IC95%: 1.16-1.35; p < 0.001, pero fue un factor protector de desgarros con RM de 0.76; IC95%: 0.71-0.81; p < 0.001. CONCLUSIONES: La tendencia de la episiotomía es decreciente, mientras que la de desgarro es inversamente proporcional. No se encontraron diferencias en la tasa de desgarro de III y IV grado.


Abstract OBJECTIVE: To determine the frequency and correlation of episiotomies and tears of patients with eutocic deliveries. MATERIALS AND METHODS: Observational and retrospective study carried out at the Hospital General de Alicante, Spain, in two periods: 1) 2008-2012 and 2) 2013-2018. Eutocic deliveries of single pregnancies, at term, in cephalic presentation are included. Study variables: episiotomies, tear, age, weeks of pregnancy, parity, labor induction, previous caesarean section, regional analgesia, weight and sex of the newborn. The results are expressed as a percentage, correlation coefficient and the variables involved with odds ratio. RESULTS: The episiotomy rate between period 1 vs. 2 decreased very significantly: 42.3% vs 32.8%; [p <0.001; OR: 0.81 (0.78-0.84)]. In contrast, the percentage of index tears: 42.7% vs 50.8%; (p <0.001; OR: 1.16 [1.13-1.20]). The correlation coefficient was -0.91. Regarding risk factors associated with episiotomy, one of them was the age under 35 years with an OR (95% CI): 1.25 (1.16-1.35; p <0.001), but it was a OR protective factor (95% CI): 0.76 (0.71-0.81; p <0.001) for the appearance of tears. CONCLUSIONS: The tendency in the realization of episiotomies is decreasing, while the tendency of the appearance of tears is inversely proportional. No differences were found in the tear rate of III and IV grade.

3.
Enferm. actual Costa Rica (Online) ; (33): 43-60, jul.-dic. 2017. tab, ilus
Artículo en Español | LILACS, BDENF | ID: biblio-891487

RESUMEN

ResumenLas prácticas del cuidado del embarazo y el parto varían ampliamente entre los países, las instituciones y los diferentes equipos encargados del cuidado obstétrico: en este contexto con prácticas tan diversas, la práctica clínica basada en la evidencia permite que el accionar de los profesionales encargados del cuidado obstétrico se fundamente en la mejor evidencia disponible. El objetivo del presente estudio es analizar la mejor evidencia científica disponible sobre los efectos adversos del uso del balón cervical durante y posterior a la labor de parto, en comparación con el uso de prostaglandinas endocervicales para la inducción del parto en mujeres con embarazo a término. La secuencia de etapas para la recolección de la información se inició con la aplicación del mapa de búsqueda en las bases de datos MEDLINE, PUBMED y COCHRANE LIBRARY, a partir de los siguientes criterios de filtro de información: artículos publicados entre los años 2010 al 2015, mujeres gestantes de cualquier edad, únicamente se incluyó estudios como ensayos aleatorizados controlados, revisiones sistemáticas, meta-análisis o guías de práctica clínica y de preferencia artículos científicos en idioma inglés o portugués. Esta búsqueda y análisis de la evidencia encontrada se realizó durante los meses de abril y mayo del año 2015 por dos revisores. Los resultados obtenidos para el análisis crítico fueron revisados minuciosamente a través de la plataforma informática FCL 2.0 con las plantillas de ensayo clínico y revisión sistemática incluidas en los anexos. Se concluye que la utilización del balón endocervical comparado con el uso de prostaglandinas endocervicales presenta menos efectos adversos de manera específica durante la labor del parto. En relación con los efectos adversos posteriores, no se encuentra mayor diferencia entre uno u otro método.


AbstractPregnancy and childbirth care practices vary widely across countries, institutions, and different obstetrical care teams: in this context with such diverse practices, evidence-based clinical practice allows the Obstetric care is based on the best available evidence. The objective of the present study is to analyze the best available scientific evidence on the adverse effects of cervical balloon use during and after labor, compared to the use of endocervical prostaglandins for induction of labor in women with term pregnancy. The sequence of steps for the collection of information was initiated with the application of the search map in the databases MEDLINE, PUBMED and COCHRANE LIBRARY, based on the following information filter criteria: articles published between the years 2010 to 2015, Pregnant women of any age, only included studies such as randomized controlled trials, systematic reviews, meta-analyzes or guidelines of clinical practice and preferably scientific papers in English or Portuguese. This search and analysis of the evidence found was carried out during the months of April and May of the year 2015 by two reviewers. The results obtained for the critical analysis were carefully reviewed through the FCL 2.0 computer platform with the clinical trial templates and systematic review included in the annexes. It is concluded that the use of the endocervical balloon compared to the use of endocervical prostaglandins presents less adverse effects specifically during labor. In relation to the subsequent adverse effects, no greater difference is found between one or the other method.


ResumoPráticas de cuidados a gravidez eo parto variam amplamente entre os países, instituições e diferentes equipas de cuidados obstétricos; neste contexto como práticas diversas, a prática clínica baseada em evidências permite que as ações dos profissionais responsáveis pela assistência obstétrica é baseada na melhor evidência disponível. O objetivo deste estudo é analisar a melhor evidência científica disponível sobre os efeitos adversos durante e após o parto com o uso de bola cervical em comparação com o uso de prostaglandina endocervical para indução do parto em mulheres com gravidez a termo. A sequência dos passos para a recolha de dados começa com a busca do mapa aplicação em Medline, PubMed e os dados Cochrane Library, onde os seguintes critérios de filtro de informação artigos introduzidos foram seleccionados publicação período entre 2010 e 2015, a população foi delimitada a mulheres grávidas de qualquer idade, digite apenas ensaios estudos clínicos randomizados, revisões sistemáticas, meta-análises ou diretrizes de prática clínica e artigos científicos de preferência em Inglês ou Português foram incluídos. Esta pesquisa e análise da evidência encontrada foi realizado durante os meses de Abril e Maio de 2015, dois colaboradores. Os resultados obtidos para a análise crítica foram cuidadosamente controlados através da plataforma FCL computador 2,0 modelos ensaio clínico e revisão sistemática estão incluídos nos anexos. Concluiu-se que o uso de bola endocervical em comparação com a utilização de prostaglandinas endocervicais tem menos efeitos adversos especificamente durante o trabalho de parto. Em ligação com os efeitos adversos subsequentes não é maior diferença entre qualquer um dos métodos.


Asunto(s)
Extracción Obstétrica/instrumentación , Complicaciones del Trabajo de Parto , Trabajo de Parto Inducido , Enfermeras Obstetrices
4.
Medisan ; 21(9)set. 2017.
Artículo en Español | LILACS | ID: biblio-995148

RESUMEN

La inducción del parto resulta un procedimiento elemental en la práctica obstétrica, que se aplica en un grupo importante de pacientes para interrumpir con éxito el embarazo debido a riesgos materno y perinatal. En este artículo se expone brevemente un nuevo método que permite abordar con efectividad la respuesta a la oxitocina, después del uso del Misofar® en función facilitadora para inducir el parto, acortando la latencia en la rotura prematura de membranas y condicionando las estructuras cervicales en gestantes con preeclampsia para obtener una mejor respuesta. Esta nueva herramienta se pone a disposición de la comunidad médica, en beneficio materno y perinatal.


Labor induction is an elementary procedure in obstetrics that is applied in an important group of patients to successfully interrupt pregnancy due to maternal and perinatal risks. In this work, a new method that allows to approach with effectiveness the oxytocin response is briefly exposed, after the use of Misofar® in facilitator function to induce labor, shortening the latency in early break of membranes and conditioning the cervical structures in pregnant women with pre-eclampsia to obtain a better response. This new tool is at medical community disposal for the maternal and perinatal benefit.


Asunto(s)
Humanos , Femenino , Embarazo , Prostaglandinas , Misoprostol/uso terapéutico , Parto Obstétrico/métodos , Trabajo de Parto Inducido/métodos , Oxitocina/uso terapéutico , Comunicación
5.
Rev. peru. ginecol. obstet. (En línea) ; 63(2): 191-197, abr.-jun. 2017. tab
Artículo en Español | LILACS | ID: biblio-991553

RESUMEN

Objetivo. Comparar la efectividad de la sonda de Foley transcervical más oxitocina con oxitocina endovenosa sola, en la inducción del parto en embarazos a término. Diseño. Estudio de casos y controles. Institución. Hospital Central "Dr. Urquinaona", Maracaibo, Venezuela. Participantes. Embarazadas a término que asistieron para maduración cervical e inducción del parto asignadas al azar con sonda de Foley transcervical - oxitocina endovenosa (grupo A) u oxitocina endovenosa (grupo B). Principales medidas de resultado. Características generales, intervalo inicio de la inducción y el parto, tasa de parto vaginal, complicaciones maternas, variables perinatales y efectos adversos. Resultados. No se encontraron diferencias estadísticamente significativas entre los grupos con relación a las características generales (p = ns). Las pacientes del grupo A presentaron un intervalo significativamente menor desde el inicio de la inducción hasta el parto comparado con las pacientes del grupo B (p < 0,05). No se hallaron diferencias significativas con relación a la tasa de partos vaginales entre los grupos (p = ns). No hubieron diferencias en los valores de Ápgar al minuto y a los 5 minutos entre los recién nacidos de ambos grupos (p = ns). El efecto adverso más común en ambos grupos fue náuseas, pero no se hallaron diferencias estadísticamente significativas entre los grupos en la frecuencia de efectos adversos (p = ns). Conclusión. El uso sonda de Foley transcervical más oxitocina disminuye el intervalo entre el inicio de la inducción y el parto comparado con la oxitocina sola, con una incidencia similar de efectos adversos maternos y perinatales.


Objective: To compare the effectiveness of transcervical Foley catheter - oxytocin with oxytocin alone for labor induction in term pregnancies. Design: Case-control study. Setting: Hospital Central "Dr. Urquinaona", Maracaibo, Venezuela. Participants: Pregnant women undergoing cervical ripening and labor induction were randomly assigned to be treated with transcervical Foley catheter - oxytocin (group A) or oxytocin alone (group B). Main outcome measures: General characteristics, interval between beginning of induction and delivery, vaginal birth rate, maternal complications, perinatal variables, and adverse effects were evaluated. Results: There were no significant differences between groups in general characteristics (p = ns). Patients of group A showed a shorter interval between the beginning of induction and delivery compared with patients in group B (p < 0.05). There was no significant difference in vaginal birth rate between groups (p = ns). Newborns of both groups had similar mean values of Apgar scores at 1 minute and 5 minutes (p = ns). The most common adverse effect in both groups was nausea, but there were no significant differences between groups in frequency of adverse effects (p = ns). Conclusions: Use of transcervical Foley catheter - oxytocin shortened the interval between beginning of induction and delivery compared with oxytocin alone, with similar incidence of maternal and perinatal adverse effects.

6.
Rev. Univ. Ind. Santander, Salud ; 49(1): 45-55, Marzo 20, 2017. tab, graf
Artículo en Español | LILACS | ID: biblio-897089

RESUMEN

RESUMEN Introducción: La ruptura prematura de membranas pretérmino (PPROM) es una patología obstétrica que genera un alto riesgo de morbilidad fetal. Pese a esto, actualmente prevalece la incertidumbre ante el manejo adecuado para ésta entidad. Objetivo: Comparar los desenlaces materno-fetales de la inducción del parto (IL) y manejo expectante (EM) Metodología: Revisión sistemática y metanálisis Fuentes de datos: Se buscó en las bases de datos MEDLINE, EMBASE, SCIELO y Google Académico. Criterios de elección, pacientes e intervenciones: Se incluyeron ensayos clínicos aleatorizados controlados y estudios de cohortes que compararan el EM e IL en pacientes con PPROM entre la semana 24 a 36 6/7, y que adicionalmente tuvieran en cuenta como desenlaces analizados: sepsis neonatal (NS), síndrome de distrés respiratorio (SDR), muerte neonatal y corioamionitis. Recolección de datos y análisis: La extracción y registro de datos se ejecutó por dos revisores de forma independiente. La evaluación de calidad se realizó con CONSORT y STROBE, según corresponda. Metanálisis: Para cada desenlance, se realizó la estimación del Riesgo Relativo (RR) consolidado, usando modelos de efectos aleatorios. Resultados: Un total de 3378 mujeres con PPROM fueron incluidas en los 9 estudios (8 ensayos clínicos). En el meta-análisis no se encontraron diferencias significativas en la ocurrencia de SDR (RR= 1,08; IC 95%: 0,89-1,31), ni de sepsis neonatal (RR= 0,92; IC 95%: 0,61-1,39), en los tratados con IL comparados con el EM. Tampoco se encontraron diferencias significativas en la ocurrencia de muertes neonatales (RR= 1,34; IC 95%: 0,93-1,93) ni corioamnionitis (RR= 0,88; IC 95%: 0,58-1,35). Conclusiones: Los resultados sugieren que no existe evidencia de diferencias estadísticamente significativas en la ocurrencia de los principales desenlaces cuando se compara EM con IL. Más estudios y con mayores tamaños de muestras son necesarios.


ABSTRACT Introduction: Preterm premature rupture of membranes (PPROM), is an obstetric pathology that causes a high-risk of morbidities and higher rate of hospital readmission in the first month of life. However, the management of this patology is still uncertain. Objetive: To compare maternal-fetal outcomes of induction of labor (IL) and expectant management (EM) in order to determine the actions to follow. Methodology: Systematic review and meta-analysis Data collection: We searched MEDLINE, EMBASE, SCIELO and Google Scholar. Selection Criteria, patients and interventions: Controlled randomized clinical trial and cohort studies were included. These studies compared the EM and IL in patients with PPROM within 24 to 36 6/7 weeks and take into account outcomes such as neonatal sepsis (NS), respiratory distress syndrome (RDS), neonatal death or chorioamnionitis. Analysis and data collection: Two authors independently executed the extraction and recording of data. Quality assessment was performed with the CONSORT or STROBE score, accordingly. Meta-analysis: For each outcome, a pooled Relative Risk was estimated using random effects models. Results 3378 women with PPROM were included in 9 studies (8 clinical trials). In the meta-analysis, we did not find a statistically significant differences in the occurrence of RDS (RR =1.08; 95% CI: 0.89-1.31 or NS (RR= 0.92; IC 95%: 0.61-1.39), in the IL group in comparison with EM. We did not find either differences in the occurrence of neonatal deaths (RR= 1.34; IC 95%: 0.93-1.93) or chorioamnionitis ( RR= 0.88; IC 95%: 0.58-1.35). Conclusions: The results suggest that there is no evidence of statistically significant differences in the occurrence of major outcomes when comparing MS with IL. Further studies and larger sample sizes will be necesary.


Asunto(s)
Humanos , Rotura Prematura de Membranas Fetales , Enfermedades Respiratorias , Corioamnionitis , Espera Vigilante , Trabajo de Parto Inducido
7.
Rev. colomb. obstet. ginecol ; 63(1): 64-72, ene.-mar. 2012. tab
Artículo en Español | LILACS | ID: lil-620844

RESUMEN

Objetivos: analizar la respuesta a una dosis intravaginal de misoprostol administrada ambulatoriamente en pacientes embarazadas a término y de bajo riesgo, con deseos de una inducción selectiva del trabajo de parto.Materiales y métodos: cohorte descriptiva realizada en 373 pacientes con embarazos de 38 o más semanas, de bajo riesgo y sin una indicación médica específica, con el deseo de la paciente de finalizar su embarazo quienes recibieron una dosis inicial de 50 mcg de misoprostol intravaginal en forma ambulatoria. Se tomaron los tiempos entre la colocación del misoprostol, la iniciación del trabajo de parto, la hora de hospitalización y del parto. El trabajo de parto fue monitorizado y se evaluó la actividad uterina para detectar polisistolia o hiperestimulación uterina y estado fetal. Se evaluó el tipo de parto, el recién nacido, la necesidad de traslado a la unidad de neonatología y complicaciones maternas. Resultados: se obtuvo respuesta exitosa con dosis única de misoprostol de 50 mcg en 308 pacientes (85,3%). La tasa total de éxito teniendo en cuenta todas las dosis de 50 mcg fue del 98,9%. El 88,3% presentó su parto dentro de las primeras 24 horas de haber sido inducidas. El 91,7% de los casos fueron partos vaginales (74,8% eutócicos y 16,9% instrumentados), y el porcentaje de cesárea fue del 8,3%. El 97,3% de los RN tuvieron un puntaje de Apgar de 7 o más al minuto, y el 100% de 8 o más a los 5 minutos. No hubo complicaciones maternas. Conclusiones: el uso ambulatorio del misoprostol surge como alternativa para la inducción del trabajo del parto por su efectividad y seguridad. Aunque este no es un estudio controlado, los resultados señalan un beneficio importante del misoprostol ambulatorio, que convendría confirmar con estudios aleatorizados.


Objectives: Analyzing response to an outpatient intravaginal dose of misoprostol administered to low-risk, full-term pregnant patients desiring selective induction of labor. Materials and methods: Descriptive cohort study of 373 low-risk pregnant patients (38 or more weeks), lacking medical indication for such procedure but desiring to terminate their pregnancy who received an initial 50 mcg dose of intravaginal misoprostol as outpatients. The time taken between placing the misoprostol, initiation of labor, hospitalization time and actual labor were recorded. Labor was monitored and uterine activity evaluated for detecting polysistolia or uterine hyper-stimulation and fetal state. The type of birth, the newborn, the need for transfer to a neonatal unit and maternal complications were also evaluated. Results: A successful response was obtained in 308 patients (85.3%) with a single 50 mcg dose of misoprostol; success rate was 98.9% considering all 50 mcg doses. 88.3% of the patients gave birth within the first 24 hours of having been induced. Vaginal birth accounted for 91.7% of the cases (74.8% eutocic and 16.9% instrumented), the rest being cesarean (8.3%). 97.3% of the newborn had an APGAR score of 7 or more at one minute and 100% scored 8 or more at 5 minutes. There were no maternal complications. Conclusions: Using out-patient misoprostol has emerged as an alternative for inducing labor due to its effectiveness and safety. Even though this was not a controlled study, the results highlighted misoprostol's important out-patient benefit which should be confirmed by randomized studies.


Asunto(s)
Adulto , Femenino , Embarazo , Misoprostol , Embarazo
8.
Medisan ; 15(4)abr. 2011. tab
Artículo en Español | LILACS | ID: lil-616188

RESUMEN

La inducción del parto con misoprostol es un procedimiento médico reconocido por la Organización Mundial de la Salud como práctica clínica beneficiosa para la madre y el perinato y, por ello, los autores de este trabajo se propusieron sistematizar su aplicación por vía vaginal, en dosis de 50 µg (máxima de 200 µg) e intervalos de 4 horas, en gestantes seleccionadas (n= 468) con criterio de interrupción médica del embarazo, ingresadas y tratadas en el Hospital Queen Elizabeth II -- institución de referencia nacional -- de Maseru, capital de Lesotho. Se considera que las experiencias y resultados obtenidos pueden ser de apreciable utilidad para los colegas que en circunstancias y condiciones similares, brinden atención médica internacionalista, puesto que la inducción del parto con ese producto fue altamente efectiva, por cuanto disminuyó el índice de cesáreas; mostró muy buen pronóstico de vida y salud, según puntaje de Apgar al quinto minuto, morbilidad y mortalidad del peripato, así como también garantizó que la morbilidad materna se correspondiera con el patrón de la población obstétrica en general y que no se produjeran defunciones.


Artificial abortion using Misoprostol is a medical procedure recognized by the World Health Organization as a clinical practice that benefits both the mother and the neonate. That is why the authors of the present work proposed to systematize its vaginal application using doses of 50 µg (200 µg as maximum) and time periods of 4 hours in pregnant women (n= 468) who were chosen under the criterion of medical pregnancy interruption and hospitalized and treated at Queen Elizabeth II Hospital -- a national reference institution -- from Maseru, capital of Lesotho. Experiences and results obtained are considered of high usefulness for colleagues who, under similar conditions and circumstances, provide international medical care. Artificial abortion using this product was highly effective; thus, rates of abdominal delivery decreased, life and health prognosis was very good according to Apgar score at fifth minute, and morbidity and mortality of the neonate were also good. In addition, maternal morbidity matched the model of general obstetric population and no death occurred.


Asunto(s)
Humanos , Adolescente , Adulto , Femenino , Embarazo , Persona de Mediana Edad , Trabajo de Parto Inducido , Misoprostol/uso terapéutico , Estudios Prospectivos
9.
Rev. chil. obstet. ginecol ; 74(4): 233-238, 2009. ilus, tab
Artículo en Español | LILACS | ID: lil-551379

RESUMEN

Objetivo: Comprobar si el sobrepeso y la obesidad materna son factores de riesgo de complicaciones pe-rinatales. Método: Estudio transversal de 1.223 gestantes nulíparas atendidas en el Hospital La Paz entre agosto 2007 y abril 2008. Las gestantes se dividieron en tres grupos según el índice de masa corporal (IMC) al inicio del embarazo: 482 con peso normal (IMC: 18,5-24,9 Kg/m²); 419 con sobrepeso (IMC: 25-29,9Kg/m²) y 322 con obesidad (IMC: >30Kg/m²). Se estudiaron las complicaciones obstétricas, semanas de gestación en el momento del parto, tipo de parto y peso fetal. Resultados: El riesgo de cesßrea en las gestantes con sobrepeso fue casi el doble que el de las gestantes de peso normal (OR: 1,9; IC95 por ciento 1,4-2,5) Las gestantes obesas sufrieron el triple de cesáreas que las de peso normal (OR: 3,1; IC95 por ciento 2,8-4,3). El número de inducciones del parto fue mayor en las gestantes con sobrepeso (OR: 1,7; IC95 por ciento 1,4-1,9) y el doble en las obesas (OR: 2,0; IC95 por ciento 1,8-2,9) con respecto a las de peso normal. El riesgo de macrosomía fetal (>4.000 gramos) fue mayor en las gestantes con sobrepeso (OR: 1,5; IC95 por ciento 1,4-2,2) y en las obesas (OR: 1,9; IC95 por ciento 1,3-2,8) que en las de peso normal. En el análisis de regresión logística multivariante (ajusfando por edad, diabetes e hipertensión gestacionales) persistió la asociación entre sobrepeso y cesárea (OR: 2,1; IC95 por ciento 1,7-2,7) y entre obesidad y cesárea (OR: 3,0; IC95 por ciento 2,6-3,8). Conclusiones: El sobrepeso y la obesidad materna al inicio del embarazo están asociados con un aumento del número de cesáreas y de inducciones del parto. Este riesgo es mayor a medida que aumenta el IMC materno.


Objective: The objective of this study is to determine if the maternal prepregnancy overweight and obesity are related to risk of cesarean delivery and other obstetrical complications. Methods: Transversal study of 1223 nulliparous women that delivered in our maternity between August 2007 and April 2008. Women were categorized by the body mass index (BMI): 482 normal weight (BMI: 18.5-24.9 Kg/m²), 419 overweight (BMI: 25-29.9 Kg/m²) and 322 obesity (BMI: >30 Kg/m²). Obstetrical complications, labor and its complications, and neonatal weight were studied. Results: Women who were overweight was nearly twice as likely to deliver by cesarean section as women with normal weight (OR: 1.8; 95 percent CI 1.4-2.9). Obese women experienced a three-fold increase in risk of cesarean section in comparison to normal weight women (OR: 3.02; 95 percent CI 2.6-4.5). Number of labor inductions was higher in overweight and obese group (OR: 1.6; 95 percent CI 1.3-1.9) and (OR: 2.1; 95 percent CI 1.7-2.9) respectively in comparison to control group. The highest risk of fetal macrosomia (weight >4000 g) was in the overweight (OR: 1.5; 95 percent CI 1.4-2.2) and obese women (OR: 1.9; 95 percent CI 1.3-2.8) compared with the normal weight women. In multivariate logistic regression analysis, the association persisted between obesity and cesarean delivery (OR 3.0; 95 percentCI 2.6-3.8) and among overweight and cesarean section (OR 2.1; 95 percentCI 1.7-2.7) after adjusting for variables such as age, diabetes and hypertension. Conclusions: Overweight or obesity prior to pregnancy are associated with an increased risk of cesarean delivery and labor inductions. This risk increases as the BMI increases.


Asunto(s)
Humanos , Adolescente , Adulto , Femenino , Embarazo , Cesárea/estadística & datos numéricos , Complicaciones del Trabajo de Parto/etiología , Sobrepeso/complicaciones , Trabajo de Parto Inducido/estadística & datos numéricos , Índice de Masa Corporal , Estudios Transversales , España/epidemiología , Estado Nutricional , Obesidad/complicaciones , Paridad , Factores de Riesgo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA