Acta Pharmaceutica Sinica ; (12): 2442-2448, 2020.
Artículo en Chino | WPRIM | ID: wpr-829382

RESUMEN

To establish a method for the determination of polymer impurities in cefixime raw materials and preparations, a cefixime degradation solution containing polymer impurities was prepared by forced polymerization. Polymer impurities in the degradation solution were separated and identified by high performance gel chromatography and the column switching-LC-MSn method. A new RP-HPLC method for cefixime polymer was established and validated with a Phenomenex Gemini-C18 column using a mobile phase gradient elution of 0.5% formic acid-water solution and 0.5% formic acid-acetonitrile solution. The results showed that when using this high performance gel chromatography method some small molecular weight impurities were co-eluted with the polymers, resulting in a poor specificity and poor quantitative accuracy. But when using the RP-HPLC method, three polymer impurities were detected with good specificity, sensitivity and robustness, including two cefixime dimers, and dehydrate dimer. Therefore, the described RP-HPLC method is suitable for the quality control of polymer impurities in cefixime, and cefixime degradation solution can be used as suitable solution for analysis of cefixime polymers.

2.
Acta Pharmaceutica Sinica ; (12): 1889-1896, 2020.
Artículo en Chino | WPRIM | ID: wpr-825166

RESUMEN

To establish a method for the determination of polymer impurities in ceftazidime raw materials and preparations, a ceftazidime degradation solution containing polymer impurities was prepared by forced polymerization. Polymer impurities in the degradation solution were separated and identified by high performance gel chromatography and the column switching-LC-MSn method. A new RP-HPLC method for ceftazidime polymer was established and validated with a Phenomenex Gemini-C18 column using a mobile phase gradient elution of 0.02 mol·L-1 phosphate buffer, methanol and acetonitrile. The results showed that when using this high performance gel chromatography method some small molecular weight impurities were co-eluted with the polymers, resulting in a poor specificity and poor quantitative accuracy. But when using the RP-HPLC method, four polymer impurities were detected in the 25-45 min time range with good specificity, sensitivity and robustness, including two ceftazidime dimers, trimers, and derivatives. Therefore, the described RP-HPLC method is suitable for the quality control of polymer impurities in ceftazidime, and ceftazidime degradation solution can be used as suitable solution for analysis of ceftazidime polymers.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA