Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 244
Filtrar
1.
Chinese Journal of Analytical Chemistry ; (12): 121-129,中插38-中插43, 2024.
Artículo en Chino | WPRIM | ID: wpr-1017636

RESUMEN

A rapid analytical method for simultaneous determination of 32 kinds of multi-residue veterinary drugs in eggs was developed using a modified QuEChERS technique based on a reduced graphene oxide-coated melamine sponge(r-GO@MeS)by ultra-high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The influences of graphene oxide(GO)concentrations,sponge dosages,and purification modes on drug recoveries were investigated during the purification process.The optimal purification conditions involved using a GO concentration of 0.5 mg/mL,a sponge dosage of 6.0 cm3/mL,and a dynamic purification mode of 5 extrusion cycles.Separation was achieved using an Agilent Eclipse Plus C18 RRHD column(100 mm×2.1 mm,1.8 μm),and quantitative analysis was performed by the external standard method using an electrospray ionization source(ESI)in multiple reaction monitoring(MRM)mode.The results showed that all 32 kinds of veterinary drugs exhibited good linear correlation with coefficients greater than 0.999,and matrix effects(MEs)ranging from?7.8%to 18.9%.The limits of detection(LODs)and quantification(LOQs)ranged from 0.2 to 10.2 μg/kg and from 0.6 to 28.0 μg/kg,respectively.The recoveries for the three spiked levels were in the range of 66.5%?117.5%,with intra-day and inter-day precision(Relative standard deviation)below 13.3%and 16.3%,respectively.The synthetic r-GO@MeS exhibited efficient matrix purification without the need of high-speed centrifugation or strong magnetic field assistance.This significantly shorted the sample pretreatment time and improved the convenience of the matrix purification process.Combined with UPLC-MS/MS,the method was suitable for the rapid determination of multi-residue veterinary drugs in eggs.

2.
Chinese Journal of Analytical Chemistry ; (12): 286-295,后插1-后插5, 2024.
Artículo en Chino | WPRIM | ID: wpr-1017653

RESUMEN

A new method for simultaneous determination of 23 kinds of per-and polyfluoroalkyl substances(PFASs)(13 kinds of perfluoro carboxylic acids,4 kinds of perfluoro sulfonic acids,and 6 kinds of new substitutes)in plant leaf tissue by ultra-high performance liquid chromatography-tandem mass spectrometry(UHPLC-MS/MS)using automatic online solid phase extraction(SPE)to remove the matrix interference components in plant crude extracts was developed.The plant leaf samples were extracted twice with 1%formic acid-methanol solution,then evaporated to dry,redissolved with 70%methanol solution,and directly injected for analysis.After 23 kinds of target PFASs were purified automatically by online SPE with a WAX column,the six-way valve was switched to rinse PFASs onto an alkaline mobile phase system-compatible C18 analytical column.Then,the 23 kinds of target PFASs were separated within 16 min by gradient elution using a binary mobile phase system of methanol/water(Containing 0.4%ammonium hydroxide).Tandem mass spectrometry was performed in multiple reaction monitoring(MRM)mode for online detection of various PFASs,and quantification was carried out by internal standard method.The results of the method validation showed that satisfactory average recoveries of 23 kinds of PFASs in plant leaf samples(64.2%-125.5%),precision(relative standard deviations(RSDs)of 0.7%-12.8%),linearity(R2>0.990),and sensitivity(the detection limits(S/N=3)were in the range of 0.02-0.50 μg/kg)were achieved.Finally,this method was used to detect PFASs in the marine green tide algae(Enteromorpha prolifera)and several tree leaves,and a total of 6 kinds of PFASs were detected,in which PFBA was the main contaminant.Compared with the reported offline SPE methods,the proposed online SPE technique significantly simplified the sample pretreatment process and provided an automatic,simple,and environment-friendly method for the routine monitoring of legacy and emerging PFASs in plant tissues.

3.
Journal of Modern Laboratory Medicine ; (4): 131-135,145, 2024.
Artículo en Chino | WPRIM | ID: wpr-1019928

RESUMEN

Objective To evaluate the performance of the automated magnetic beads extraction method for extraction of serum fat-soluble vitamins by liquid chromatography-tandem mass spectrometry(LC-MS/MS).Methods A total of 120 clinical residual serum samples were collected automated magnetic beads extraction method was applied to extract serum fat-soluble vitamins A,D2,D3,E and K.The linearity,limit of quantification,precision,accuracy,carryover and matrix effect of fat-soluble vitamins A,D2,D3,E and K were detected by LC-MS/MS.The consistency of the method and conventional extraction method was compared.Results The linear correlation coefficients for extracting fat-soluble vitamins A,D2,D3,E and K by automated magnetic beads extraction method were all greater than 0.99,and the quantitative limits for these five fat-soluble vitamins were 5,0.25,0.25,125 and 0.025 ng/ml.The intra-batch precision and inter-batch precision were 0.66%~4.83%and 0.15%~3.70%,respectively,and the average spike recovery rate was 87.05%~111.11%.The matrix effect was 95.43%~99.07%,and the difference between the mean value of the cyclic injection results of high-low value samples and the mean value of the cyclic injection results of low-low value samples was less than 3s of the mean value of the cyclic injection results of low-low value samples.The statistical analysis showed that the correlation between the results of the automated magnetic beads extraction method and the conventional extraction method was good(r>0.99),and there was no significant bias in the detection results of the two methods.Conclusion The automated magnetic beads extraction method for extraction of fat-soluble vitamins had good detection performance,which may be expected to improve sample flux and analysis efficiency.

4.
Herald of Medicine ; (12): 196-202, 2024.
Artículo en Chino | WPRIM | ID: wpr-1023698

RESUMEN

Objective To establish a quality control method for monitoring the blood concentrations of cyclosporin A and tacrolimus by HPLC-MS/MS,and to evaluate the quality control samples using the Westgard multi-rule theory.Methods HPLC-MS/MS was used to determine the concentration of cyclosporin A and tacrolimus in human whole blood.The quality control samples of low,medium and high concentration levels in the therapeutic drug monitoring process were statistically analyzed,Levery-Jennings and Z-score quality control charts were drawn,and the Westgard multi-rule theory was applied for in-house quality control evaluation.Results The established method was fully validated with linear ranges of 10.40-1 040.00 ng·mL-1 and 0.50-49.50 ng·mL-1,the quantification limits were 10.40 and 0.50 ng·mL-1,respectively.The extraction recoveries were 108.61%-113.24%and 101.99%-109.37%,respectively.The matrix factors normalized by internal standard were 106.68%-111.27%and 95.70%-97.81%for cyclosporin A and tacrolimus,respectively.The intra-day and inter-day accuracy and precision were less than 15.0%.Other parameters were also validated and met the acceptance criteria.Levery-Jennings and Z-score quality control charts showed that there were 4 warnings(violation of the 12s rule)in the results of the 26 groups of quality control samples in the third quarter of 2022,and no phenomenon was observed to be out of control.Conclusion The established in-house quality control system for therapeutic drug monitoring of cyclosporin A and tacrolimus can effectively ensure the accuracy of blood drug concentration detection.

5.
Herald of Medicine ; (12): 345-351, 2024.
Artículo en Chino | WPRIM | ID: wpr-1023718

RESUMEN

Objective To establish a method of LC-MS/MS for determining cordycepin(Cor)and 3′-deoxyinosine(3′-Deo)concentration in rat plasma,and to study their pharmacokinetics in rats.Methods Protein was precipitated with methanol using 2-chloadenosine(2-Chl)as an internal standard.The chromatography was performed on Kinetex C18(3 mm×100 mm,2.6 μm,Phenomenex,USA)with gradient elution in aqueous(5 mmol·L-1 ammonium acetate)-methanol solution as mobile phase.ESI ion source was used for mass spectrometry,and positive ion multiple reaction monitoring(MRM)was used for scanning detection.The pharmacokinetics of Cor and 3′-Deo after oral administration of Cor(10 mg·kg-1)were studied in rats.Results Cor at 0.5-100 ng·mL-1 and 3′-Deo at 1-200 ng·mL-1 had good linearity,and the lower limits of quantification were 0.5 and 1 ng·mL-1,respectively.After oral administration of Cor in rats,the plasma concentration of Cor was low,which was mainly converted into the metabolite 3′-Deo.The Cmax of Cor and 3′-Deo were(5.4±3.4)and(142.0±50.0)ng·mL-1,and AUC0-360min min were(658.4±459.3)and(18 034.9±4 981.1)ng·min·mL-1,respectively.Conclusion The method is simple,sensi-tive,and accurate,which is suitable for determining Cor and 3′-Deo concentration in plasma and the pharmacokinetic study.

6.
Artículo en Chino | WPRIM | ID: wpr-1028725

RESUMEN

AIM To analyze the component composition of Xeriga-4 Powder,and to determine the contents of phellodendrine,chlorogenic acid,gardenoside,berberine,rutin and curcumin.METHODS The high performance liquid chromatography-Q-exactive orbitrap mass spectrometry(HPLC-Q-Exactive-MS)qualitative analysis was performed on a 35℃thermostatic Agilent ZORBAX SB-Aq column(4.6 mm×150 mm,5 μm),with the mobile phase comprising of methanol-0.1%formic acid flowing at 0.35 mL/min in a gradient elution manner,and electron spray ionization source was adopted in positive and negative ion scanning.High performance liquid chromatography tandem mass spectrometry(HPLC-MS/MS)quantitative analysis was performed on a 35℃thermostatic Shim-pack GIST-HP C18 column(2.1 mm×100 mm,3 μm),with the mobile phase comprising of methanol-0.1%formic acid flowing at 0.25 mL/min in a gradient elution manner,and electron spray ionization source was adopted in positive and negative ion scanning with multiple reaction monitoring mode.RESULTS Total 65 constituents were identified,containing 19 alkaloids,13 organic acids,13 flavonoids,7 curcumins,6 iridoids,4 fatty acids,2 aldehydes,and 1 amino acid.Six constituents showed good linear relationships within their own ranges(r≥0.999 1),whose average recoveries were 96.44%-102.37%with the RSDs of 2.05%-3.74%.CONCLUSION This study can provide a reference for the quality control for Xieriga-4 Powder.

7.
JOURNAL OF RARE DISEASES ; (4): 42-49, 2024.
Artículo en Chino | WPRIM | ID: wpr-1032065

RESUMEN

ObjectiveUsing the liquid chromatography-tandem mass spectrometry (LC-MS/MS) to determine the plasma level of Lyso-GL3 in patients with Fabry disease and to analyze the clinical application of the method.MethodsThirty-nine patients with a genetic diagnosis of Fabry disease were included, and plasma levels of Lyso-GL3 were measured by LC-MS/MS analysis, and detailed clinical information of the patients was obtained including: α-galactosidase A activity, genetic variants, quantification of urine protein, mean arterial pressure, and estimation of glomerular filtration rate, and the differences in the levels of Lyso-GL3 in different clinical phenotypes and genotypes were statistically analyzed, as well as the association with clinical indicators.ResultsLyso-GL3 showed good linearity within 0.7856-400 ng/mL(r=0.9992).Further analysis of 39 Fabry disease patients diagnosed in Ruijin Hospital, Shanghai Jiao Tong University School of Medicine showed a median Lyso-GL3 concentration of 23.6 ng/mL(4.3-92.9 ng/mL); Lyso-GL3 levels were significantly higher in patients with both the frameshift and the splicing mutations, as well as in patients with the nonsense mutations, than in patients with the missense mutations (median value 119.7 ng/mL vs. 11.9 ng/mL, P=0.006, and median value 97.0 ng/mL vs. 11.9 ng/mL, P=0.015, respectively). Whereas, association analysis revealed that Lyso-GL3 was not significantly associated with urinary protein, mean arterial pressure and estimated glomerular filtration rate.ConclusionsThe using of LC-MS/MS to quantify plasma Lyso-GL showed significant differences in Lyso-GL3 concentrations between classical and atypical phenotypes, suggesting that plasma Lyso-GL3 may help with clinical phenotypes. However, Lyso-GL3 levels is found to be overlapped between genotypes. No significant linear correlation was found between Lyso-GL3 and renal clinical indicators, suggesting the urgent need in finding a more accurate tool to assess renal involvement and prognosis in patients with Fabry disease.

8.
Artículo en Chino | WPRIM | ID: wpr-1036348

RESUMEN

Backgroud At present, there is no unified standard for the detection of glufosinate ammonium and three metabolites in urine, which affects the accurate assessment of occupational exposure risk to a certain extent. It is of great significance to establish a rapid and effective inspection method to ensure occupational safety and public health. Objective To establish an ultra performance liquid chromatography-tandem mass spectrometry for simultaneous determination of glufosinate ammonium and three metabolites in urine. Methods The effects of dilution solvents and dilution ratios on the response values of glufosinate ammonium and three metabolites were compared, and the retention capacities of solid phase extraction columns for targets as well as the effects of chromatographic columns and mobile phase systems on chromatographic peaks were analyzed. Samples were quantified by matrix effect matching external standard method. Accuracy of the method was evaluated by recovery rate of standard addition, and precision of the method was evaluated by relative standard deviation of intra-day and inter-day measurements. Urine samples of 30 health individuals were collected to evaluate the application of the method. Results The urine samples were diluted with 0.2 mL water and 0.6 mL acetonitrile, purified by HLB solid phase extraction columns, and separated by Dikma Polyamino HILIC columns, and gradient elution was carried out with 0.5 mmol·L−1 ammonium acetate and 0.1% ammonia water as mobile phase, which achieved a good peak shape and mass spectrum response. The linearities of the four target compounds were good in the range of 0.5-50 ng·mL−1, and the correlation coefficients (r) were all greater than 0.998. The detection limits were 0.56-2.86 μg·L−1, the quantification limits were 1.87-29.54 μg·L−1, and the recovery rates of standard addition ranged from 75.0% to 103.6%, The relative standard deviations of intra-batch and inter-batch were from 2.5% to 8.1% and from 4.3% to 9.3% respectively. The method was applied to detect 30 urine samples of subjects, and no target was detected. Conclusion The method is simple, rapid, sensitive, and accurate. It is suitable for the determination of glufosinate ammonium and its metabolites in human urine without derivatization.

9.
JOURNAL OF RARE DISEASES ; (4): 42-49, 2024.
Artículo en Inglés | WPRIM | ID: wpr-1006916

RESUMEN

ObjectiveUsing the liquid chromatography-tandem mass spectrometry (LC-MS/MS) to determine the plasma level of Lyso-GL3 in patients with Fabry disease and to analyze the clinical application of the method.MethodsThirty-nine patients with a genetic diagnosis of Fabry disease were included, and plasma levels of Lyso-GL3 were measured by LC-MS/MS analysis, and detailed clinical information of the patients was obtained including: α-galactosidase A activity, genetic variants, quantification of urine protein, mean arterial pressure, and estimation of glomerular filtration rate, and the differences in the levels of Lyso-GL3 in different clinical phenotypes and genotypes were statistically analyzed, as well as the association with clinical indicators.ResultsLyso-GL3 showed good linearity within 0.7856-400 ng/mL(r=0.9992).Further analysis of 39 Fabry disease patients diagnosed in Ruijin Hospital, Shanghai Jiao Tong University School of Medicine showed a median Lyso-GL3 concentration of 23.6 ng/mL(4.3-92.9 ng/mL); Lyso-GL3 levels were significantly higher in patients with both the frameshift and the splicing mutations, as well as in patients with the nonsense mutations, than in patients with the missense mutations (median value 119.7 ng/mL vs. 11.9 ng/mL, P=0.006, and median value 97.0 ng/mL vs. 11.9 ng/mL, P=0.015, respectively). Whereas, association analysis revealed that Lyso-GL3 was not significantly associated with urinary protein, mean arterial pressure and estimated glomerular filtration rate.ConclusionsThe using of LC-MS/MS to quantify plasma Lyso-GL showed significant differences in Lyso-GL3 concentrations between classical and atypical phenotypes, suggesting that plasma Lyso-GL3 may help with clinical phenotypes. However, Lyso-GL3 levels is found to be overlapped between genotypes. No significant linear correlation was found between Lyso-GL3 and renal clinical indicators, suggesting the urgent need in finding a more accurate tool to assess renal involvement and prognosis in patients with Fabry disease.

10.
China Medical Equipment ; (12): 42-47, 2024.
Artículo en Chino | WPRIM | ID: wpr-1026483

RESUMEN

Objective:To establish a determination method of high performance liquid chromatography-tandem mass spectrometry(HPLC-MS/MS)for serum hydrogen sulfide(H2S),so as to determine serum H2S.Methods:This study collected serum samples of 30 patients who admitted to Beijing Jishuitan Hospital affiliated to Capital Medical University from April 2023 to May 2023,and they were divided into osteoporosis group and control group according to whether existed osteoporosis,with 15 cases in each group.HPLC-MS/MS and enzyme-linked immunosorbent assay were used respectively to determine serum H2S.And then,the precision,accuracy and correlation between the two methods were evaluated.Results:HPLC-MS/MS can fast detect the content of serum H2S through detecting methylene blue in the serum,which analysis time was only 1.5 minutes,and its specificity was higher.The relative standard deviation(RSD)value of quality control plasma was 8.77%,and that of quality control plasma with the standard and pure water with standard were respectively 4.58% and 8.23%.The precisions of them met the requirement of detection(less than 20%).The recovery was 103.5% through used the above data,and the accuracy accorded with the requirements of quantitative detection(recovery was 103.5%).Conclusion:HPLC-MS/MS method is rapid and accurate in detecting H2S,which can accurately detect the content of serum H2S.This method has a series of advantages include fast,high throughput,high sensitivity and favorable stability,which contributes to conduct basic research of the content of serum H2S in the cellular pathways of human.

11.
Journal of Preventive Medicine ; (12): 86-88, 90, 2024.
Artículo en Chino | WPRIM | ID: wpr-1038624

RESUMEN

Objective@#To establish a non-derivatization-PriME-ultra-high performance liquid chromatography-tandem mass spectrometry method for simultaneou determination of 9 kinds of biogenic amines in yellow rice wine.@*Methods@#Yellow rice wine samples were purified by PriME HLB solid phase extraction column purification, separated using Waters XSelect HSS T3 column (150 mm×2.1 mm, 3 μm), and qualified using multiple reaction monitoring mode, electrospray ion source positive ion and external standard method.@*Results@#There was a good linear relationship for the 9 kinds of biogenic amines at 2.0 to 500.0 μg/L (r≥0.996). The limit of detection was 0.1 to 0.2 mg/L, and the limit of quantitation was 0.3 to 0.6 mg/L. The spike recovery rate of 9 kinds of biogenic amines ranged from 83.5% to 108.6% at 0.1 and 1.0 mg/L, with relative standard deviations of 2.8% to 8.7%.@*Conclusion@#Non-derivation-prime ultra-high performance liquid chromatography-tandem mass spectrometry can be used for the rapid quantitative detection of biogenic amines in yellow rice wine.

12.
Acta Pharmaceutica Sinica ; (12): 1293-1300, 2023.
Artículo en Chino | WPRIM | ID: wpr-978681

RESUMEN

A hydrophilic interaction chromatography tandem mass spectrometry method was developed for simultaneous quantification of 35 components in gualoupi injection. The analytes were separated with an ACQUITY XBridge Amide column using 20 mmol·L-1 ammonium formate aqueous solution (pH 3.0) as mobile phase A and 20 mmol·L-1 ammonium formate (pH 3.0)∶acetonitrile (1∶9) as mobile phase B for gradient elution. Mass spectrometry with dynamic multiple reaction monitoring and external standard method were used for quantitative analysis. A total of 35 components were determined in 10 batches of gualoupi injection. The results showed that the 35 compounds had a good linear relationship within their respective concentration ranges with the correlation coefficients (R2 > 0.998 0), the recoveries ranged from 76.6% to 118.5%. The results showed that γ-aminobutyric acid, trigonelline, alanine, threonine, homoserine, citrulline, and leucine were abundant in gualoupi injection, while nicotinamide, methylsuccinic acid, cytosine and choline account for a low percentege. The present study provides an important reference for elucidation of the effective material basis and the improvement of quality standard of gualoupi injection.

13.
Acta Pharmaceutica Sinica ; (12): 1663-1668, 2023.
Artículo en Chino | WPRIM | ID: wpr-978726

RESUMEN

Antibody-drug conjugate (ADC) has the characteristics of low toxicity and high efficiency, and plays an important role in cancer treatment. However, due to the complexity of its structure, it brings difficulties in pharmacokinetic (PK) bioanalysis. This study established an analytical method for the detection of ADC (RC108) in cynomolgus monkey plasma by ligand-binding assay (LBA) and liquid chromatography tandem mass spectrometry (LC-MS/MS), which was used to analyze and quantify the total antibody, bound antibody and free drug in cynomolgus monkey plasma. Based on the LBA method, rabbit anti-RC108 Fab and mouse anti-MMAE (monomethyl auristatin E) mAb were pre-coated in 96-well plates as the total antibody and antibody binding reagents, respectively. The samples to be tested were added, and then the detection reagents were added in turn. Goat anti-human IgG (H+L)-HRP, chromogenic solution tetramethylbenzidine (TMB), H2SO4 terminate the reaction, read data at 450 nm/630 nm wavelength of microplate reader; LC-MS/MS analysis method quantifies MMAE concentration, and refer to relevant regulations for methodological validation. The analytical method for quantifying total antibody, bound antibody and free drug of RC108 drug obtained good accuracy and precision, and the selectivity, dilution linearity, hook effect, parallelism and stability were verified. Meet the requirements of biological analysis. Finally, a bioanalytical method for the determination of the concentration of the test substance RC108 (total antibody, conjugated antibody, free MMAE) in cynomolgus monkey plasma with high sensitivity and high throughput was established by LBA and LC-MS/MS method. Subsequent non-clinical research on PK research in cynomolgus monkeys will provide technical support.

14.
China Tropical Medicine ; (12): 260-2023.
Artículo en Chino | WPRIM | ID: wpr-979627

RESUMEN

@#Abstract: Objective To investigate a poisoning incident caused by eating eight treasure congee, and establish liquid chromatography (LC)-mass spectrometry (MS)/MS screening method of 28 alkaloids to provide references for disposal of similar poisoning incidents. Methods LC-MS/MS was used for screening 28 alkaloids in the urine, eight treasure congee and food raw material, and the detected alkaloids were quantified. Samples were extracted with 0.4% formic acid aqueous solution and separated by a Acquity UPLC BEH C18 column (1.7 μm, 100 × 2.1 mm). Acetonitrile-0.2% formic acid aqueous solution was used as the mobile phase and gradient elution was adopted. The ionization mode was electrospray positive ionization mode, and the detection method was multi-reaction monitoring (MRM). Analytes were quantified with the external standard method. Results In the concentration range of 0-100 ng/mL, the linear correlation coefficient r were greater than 0.999 for 28 alkaloids. The recovery of 28 alkaloids in urine sample ranged from 63.0% to 105.0%, and the relative standard deviations (RSDs) were between 5.8% and 8.6%. The recovery of 28 alkaloids in eight treasure congee sample ranged from 72.0% to 109.0%, and the RSDs were between 6.3% and 9.7%. The recovery of 28 alkaloids in semen sesami nigrum sample ranged from 60.0% to 95.0%, and the RSDs were between 4.8% and 8.2%. Hyoscyamine (2 380.0 ng/mL), scopliamine (3.6 ng/mL) and rac-anisodamine (4.7 ng/mL) were detected in the patient's urine. Hyoscyamine (63.3 μg/g), scopliamine (5.7 μg/g) and rac-anisodamine (2.1 μg/g) were detected in eight treasure congee. Hyoscyamine (901.0 μg/g), scopliamine (80.0 μg/g) and rac-anisodamine (30.1 μg/g) were detected in the seed of Datura stramonium L. The ratio of scopliamine and hyoscyamine in the seed of D. stramonium was 1∶11, which complies with the characteristics of D. stramonium L. In urine sample, the proportion of scopliamine and rac-anisodamine was 0.15% and 0.20%, and hyoscyamine accounted for 99.65%. Conclusion Seed morphology, the content range and proportion of three alkaloids are all in accord with the characteristics of D. stramonium. Combined with the clinical symptoms of atropine poisoning, it can be deduced that this incident is a family food poisoning caused by accidental consumption of seed of D. stramonium L. The method can provide technical support for the clinical diagnosis and treatment of alkaloid poisoning patients, and also provide a basis for emergency detection and disposal of alkaloid poisoning events.

15.
Chinese Journal of Biotechnology ; (12): 1188-1201, 2023.
Artículo en Chino | WPRIM | ID: wpr-970432

RESUMEN

To investigate the formation of polystyrene nanoplastic-plant protein corona and its potential impact on plants, three differently modified polystyrene nanoplastics with an average particle size of 200 nm were taken to interact with the leaf proteins of Impatiens hawkeri for 2 h, 4 h, 8 h, 16 h, 24 h, and 36 h, respectively. The morphological changes were observed by scanning electron microscopy (SEM), the surface roughness was determined by atomic force microscopy (AFM), the hydrated particle size and zeta potential were determined by nanoparticle size and zeta potential analyzer, and the protein composition of the protein corona was identified by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The proteins were classified in terms of biological processes, cellular components, and molecular functions to study the adsorption selection of nanoplastics to proteins, investigate the formation and characteristics of polystyrene nanoplastic-plant protein corona and predict the potential impact of protein corona on plants. The results showed that the morphological changes of the nanoplastics became clearer as the reaction time extends, as evidenced by the increase in size and roughness and the enhancement of stability, thus demonstrating the formation of protein corona. In addition, the transformation rate from soft to hard protein corona was basically the same for the three polystyrene nanoplastics in the formation of protein corona with leaf proteins under the same protein concentration conditions. Moreover, in the reaction with leaf proteins, the selective adsorption of the three nanoplastics to proteins with different isoelectric points and molecular weights differed, and the particle size and stability of the final formed protein corona also differed. Since a large portion of the protein fraction in protein corona is involved in photosynthesis, it is hypothesized that the formation of the protein corona may affect photosynthesis in I. hawkeri.


Asunto(s)
Poliestirenos/química , Corona de Proteínas/química , Microplásticos , Proteínas de Plantas , Cromatografía Liquida , Espectrometría de Masas en Tándem , Nanopartículas/química
16.
Artículo en Chino | WPRIM | ID: wpr-986015

RESUMEN

Objective: To establish ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the determination of 22 phospholipids in serum. Methods: In September 2022, Using synthetic non endogenous phospholipids as internal standard, phospholipids in serum were extracted by methanol-dichloromethane (2∶1, V/V) protein precipitation method. Chromatographic separation was achieved on an ACQUITY UPLC BEH shield RP18 column, and the mobile phase was methanol/water (5∶95, V/V) containing 10 mM ammonium formate and methanol. Detection was performed in multiple reaction monitoring mode with ion mode switching. And the method was applied by analyzing phospholipids in the serum of coal workers' pneumoconiosis patients. Results: The 22 phospholipids showed good linear relationships in their respective concentration ranges and the correlation coefficients were higher than 0.990. The spiked recoveries of the 22 phospholipids were 81.03%-121.63% at the three spiked levels. The intra-assay were less than 14.52%, and the inter-assay were less than 15.00%. Conclusion: The method with the advantages of simplicity, stability and high sensitivity, and it can be used for the analysis of phospholipids in serum.


Asunto(s)
Humanos , Cromatografía Liquida , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Fosfolípidos , Metanol
17.
China Pharmacy ; (12): 2074-2078, 2023.
Artículo en Chino | WPRIM | ID: wpr-987134

RESUMEN

OBJECTIVE To establish a method for simultaneous determination of 15 bile acids in Tongren niuhuang qingxin pills, and to determine the contents of 15 batches of samples. METHODS Using dehydrocholic acid as internal standard, the determination was performed by ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. The determination was performed on Hypersil GOLD C18 column with methanol-0.1% formic acid solution as the mobile phase by gradient elution at the flow rate of 0.2 mL/min. The column temperature was 40 ℃ , and the sample size was 2 µL. Using heated electrospray ion source, parallel reaction monitoring mode scanning was performed in negative ion mode. SPSS 24.0 software was used for chemical pattern recognition analysis of content determination results. RESULTS The 15 bile acid components had a good linear relationship with peak area (all R2≥0.998 9); their precision, repeatability and stability were all good (all RSD≤5.49%); the average recoveries were 93.8%-105.7% (RSD was 0.5%-5.8%). The average contents of taurocholic acid, 7-oxodeoxycholic acid, 12-dehydrocholic acid, glycocholic acid, 3-oxo-7α, 12α-hydroxy-5β-cholanoic acid, taurochenodeoxycholic acid, 3α-hydroxy- 7-oxo-5β -cholanic acid, hyocholic acid, taurodeoxycholic acid sodium salt hydrate, hyodeoxycholic acid, cholic acid, glycochenodeoxycholic acid, glycodeoxycholic acid, chenodeoxycholic acid and deoxycholic acid were 670.56, 25.97, 10.54, 280.12, 4.04, 29.81, 182.98, 813.55, 120.95, 220.31, 797.37, 18.37, 68.59, 30.13, 59.82 μg/g, respectively. Both cluster analysis and principal component analysis divided 15 batches of Tongren niuhuang qingxin pills into 2 categories, S1-S12 as one category and S13-S15 as the other category. CONCLUSIONS The established method is accurate, sensitive and specific, and can determine many types of bile acids. It also can quickly achieve the quantitative analysis of 15 bile acids in Tongren niuhuang qingxin pills, which is suitable for the quality control of this drug.

18.
Artículo en Chino | WPRIM | ID: wpr-988909

RESUMEN

ObjectiveA method was developed for the rapid determination of 18 common disinfection by-products including halogenated oxides and haloacetic acid (HAAs) in drinking water by high performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS). MethodThe water sample was filtered by 0.22 μm hydrophilic membrane then the analytes were separated on a PFP (2.1 mm× 100 mm, 2.7 μm) pentafluorophenyl column with 0.1% acetic acid and acetonitrile as mobile phase gradient elution. Ionization in anionic electrospray mode was detected by multi-reaction monitoring (MRM) mode. The external standard method was used for quantitation. ResultsThe correlation coefficients of 18 disinfection by-products were above 0.999 in the corresponding linear range. The average spiked recoveries of 1, 10 and20 times of LOQ of each analyte were 91.6%‒101.8%, and the relative standard deviation (RSD) was 1.2%‒6.4%. The LOD and LOQ were 0.020‒2 μg·L-1 and 0.050‒5 μg·L-1, respectively. ConclusionThis method is simple, sensitive and accurate, and could be used for the routine analysis of 18 common disinfection by-products in drinking water.

19.
Artículo en Chino | WPRIM | ID: wpr-995794

RESUMEN

Objective:The aim of our study is to develop an LC-MS/MS method using isotope internal standard for the determination of vancomycin in human blood serum and to validate its clinical value.Method:We conducted a methodological evaluation study using serum samples from 221 hospitalized patients (142 males and 79 females; mean age (59.31±15.32) years) who received treatments of vancomycin at the Sir Run Run Shaw Hospital of Zhejiang University between March 2021 and June 2022. In addition, thirty clinical residual serum samples from healthy individuals (15 males and 15 females; mean age (35.65±9.86) years) undergoing physical examination were used for methodological evaluation. The method was established using AB Sciex Triple Quad 4500 MD liquid chromatography-tandem mass spectrometer and chromatographic separation was carried out using a Phenyl-Hexyl column with gradient elution. The mobile phase was composed of 0.1% formic acid in water and methanol; the column temperature was 40℃; Vancomycin-[d12] TFA salt was used as the internal standard (IS). The sensitivity, specificity, linearity, accuracy, imprecision, matrix effect, and carry-over of the method were evaluated.Results:The detection limit of vancomycin was 0.2 mg/L and the lowest limit of quantification was 0.5 mg/L. It showed good linearity ( R2=0.998 4) in the 1 to 50 mg/L concentration range. Accuracy (recovery rate 87.45%-112.69%), intra-day and inter-day imprecision ( CV 4.91%-7.69%), internal standard standardized matrix factor (90.22%-104.29%). Carryover pollution was negligible. Of the 221 patients, the mean trough concentrations of vancomycin in serum was (13.15±8.56) mg/L. Conclusion:The LC-MS/MS method for the detection of serum vancomycin established in our laboratory meets the requirements of the reference method, and can be used for the monitoring of clinical therapeutic drugs.

20.
Artículo en Chino | WPRIM | ID: wpr-995799

RESUMEN

Objective:High performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was used to quantify the levels of vitamins A, D and E in pregnant women during the second trimester, and to investigate the change trends of serum vitamins A, D and E levels during pregnancy.Method:A total of 720 pregnant women with an average age of (29.7±4.4) years and 12-22 weeks of gestation were included from October 1, 2021 to October 30, 2022 in the obstetrics department of the People′s Hospital of Wuhan University. The concentrations of vitamins A, D and E were determined by HPLC-MS/MS. The concentration levels of each group were statistically analyzed and the deficiency rate were calculated.Results:The distribution range of vitamin A, D and E (95% CI) was 0.74-2.74 μmol/L, 2.88-25.37 ng/ml and 6.18-35.08 μmol/L, with the deficiency rates were 9.30%, 93.76% and 35.83%, respectively. Vitamin A, D and E levels in the twin group were (1.67±0.51) μmol/L, (13.18±7.44) ng/ml and 11.97 (8.85, 14.60) μmol/L, respectively. They were significantly higher than those in the singlet group (1.45±0.36) μmol/L, (10.87±5.26) ng/ml and 10.46 (6.99, 14.11) μmol/L, with statistical significance by independent sample t-test ( P<0.001). The concentration of vitamin D in the lower BMI group (<22 kg/m 2) was (12.54±5.74) ng/ml, significantly higher than that in the fat group (≥22 kg/m 2) (10.46±4.90) ng/ml, and the rank-sum test was statistically significant ( P<0.001). Conclusion:In this study, the levels of three vitamins were monitored in mid-pregnancy using HPLC-MS/MS, and the changes of serum vitamin A, D, and E levels during pregnancy were analyzed.

SELECCIÓN DE REFERENCIAS