Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Medical Instrumentation ; (6): 57-61, 2021.
Artículo en Chino | WPRIM | ID: wpr-880423

RESUMEN

Polymer hydrophilic lubricating coatings for medical catheters refer to highly hydrophilic coating films fixed on the surface of catheters with binding force, which can reduce the surface friction with human tissues during the use of interventional catheters, improve the patient comfort of and effectively reduce the incidence of infection. Based on the development process of medical catheter coating, this review summarizes recent advances in the field of polymer hydrophilic lubricating coatings for medical catheters from types of hydrophilic coating polymer, development of coating technology and establishment of coating performance evaluation method. Main problems in this field are analyzed and development trends in the future are prospected.


Asunto(s)
Humanos , Catéteres , Interacciones Hidrofóbicas e Hidrofílicas , Polímeros
2.
Journal of Biomedical Engineering ; (6): 238-244, 2019.
Artículo en Chino | WPRIM | ID: wpr-774215

RESUMEN

The biocompatible hydrogel was fabricated under suitable conditions with natural dextran and polyethylene glycol (PEG) as the reaction materials. The oligomer (Dex-AI) was firstly synthesized with dextran and allylisocyanate (AI). This Dex-AI was then reacted with poly (ethyleneglycoldiacrylate) (PEGDA) under the mass ratio of 4∶6 to get hydrogel (DP) with the maximum water absorption of 810%. This hydrogel was grafted onto the surface of medical catheter via diphenyl ketone treatment under ultraviolet (UV) initiator. The surface contact angle became lower from (97 ± 6.1)° to (25 ± 4.2)° after the catheter surface was grafted with hydrogel DP, which suggests that the catheter possesses super hydrophilicity with hydrogel grafting. The evaluation after they were implanted into ICR rats subcutaneously verified that this catheter had less serious inflammation and possessed better histocompatibility comparing with the untreated medical catheter. Therefore, it could be concluded that hydrogel grafting is a good technology for patients to reduce inflammation due to catheter implantation, esp. for the case of retention in body for a relative long time.


Asunto(s)
Animales , Ratas , Compuestos Alílicos , Materiales Biocompatibles , Catéteres , Dextranos , Hidrogel de Polietilenoglicol-Dimetacrilato , Hidrogeles , Interacciones Hidrofóbicas e Hidrofílicas , Isocianatos , Polietilenglicoles , Agua
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA