Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery ; (12): 397-400, 2018.
Artículo en Chino | WPRIM | ID: wpr-749771

RESUMEN

@#Objective     To compare clinical outcomes between the performed titanium locking plate and nickel-titanium memory alloy embracing fixator for the treatment of multiple rib fractures, and to select a better internal fixator for multiple rib fractures. Methods     A total of 206 consecutive patients with multiple rib fractures were admitted to Department of Cardiothoracic Surgery in Beijing Luhe Hospital of Capital Medical University from October 2011 to September 2016. According to different treatment strategies, the patients were divided into 2 groups: a performed titanium locking plate group (a titanium plate group, n=105) and a nickel-titanium memory alloy embracing fixator group (an embracing fixator group, n=101). There were 82 males and 23 females with a mean age of 46.5±9.7 years ranging from 23 to 65 years in the titanium plate group, and 83 males and 18 females with a mean age of 44.7±10.3 years ranging from 19 to 63 years in the embracing fixator group. The preoperative data, curative outcomes, visual analogue scale (VAS) and postoperative complications were compared between the two groups. Results     There was no statistical difference in the preoperative data between the two groups, and all patients successfully completed the operation. Compared with the embracing fixator group, the incision length and operation time were shorter, intraoperative bleeding and VAS score were less, and curative outcome was better in the titanium plate group. Conclusion     The performed titanium locking plate has a great advantage in the clinic, which can be preferred.

2.
Acta Universitatis Medicinalis Anhui ; (6): 689-691, 2014.
Artículo en Chino | WPRIM | ID: wpr-448329

RESUMEN

To compare the effect of surgical and non-surgical treatment for multiple fractured ribs retrospectively, with 30 cases in each group. Patient's length of stay, visual analogue scale ( VAS) pain, independent ambulation time, cost of hospitalization, thoracoplasty degree and the lung ventilation function were evaluated. The results showed that VAS declined obviously in patients of surgical group, length of stay and independent ambulation time were shorter. Compared to the non-surgical group, the maximal voluntary ventilation increased significantly and ref-erral rib reduction was significantly better, but cost of the surgical group was higher. It's an effective treatment for using nickel titanium memory alloy embracing fixator in the treatment of multiple fractured rips, and is worthy of clinical application.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA