Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Philippine Journal of Obstetrics and Gynecology ; : 1-8, 2020.
Artículo en Inglés | WPRIM | ID: wpr-876566

RESUMEN

Background@#Estimation of fetal weight through ultrasound or clinically, is important in the management of pregnant women. In low resource settings, where ultrasound is scarce, determination of the superior clinical method between Johnson’s rule and palpation method is of significant value.@*Objective@#The objective of this study was to determine the best clinical method in estimating fetal weight in term parturients in a tertiary government hospital. 140 term mothers with singleton pregnancies in cephalic presentation were included in this study.@*Methodology@#Fetal weight was estimated using both palpation method and Johnson’s rule and compared to the actual fetal weight. Effects of body mass index (BMI), cervical dilatation, and engagement on the accuracy of both methods were evaluated using one-way ANOVA and test of proportions. The accuracy of both methods were calculated by mean absolute error and bias. Bland-Altman analysis was used to see limits of agreement and the mean difference between estimated fetal weight to actual birthweight.@*Results@#Mean estimated fetal weight (EFW) was 2846.39 ± 427.29g by Johnson’s and 2904.29 ± 372.79g by palpation with a mean actual birthweight of 3028.30 ± 441.52g. Using paired t-test, no significant differences were found in EFW by the two methods and actual birthweight. Palpation had more estimates that differed from actual by < 100 grams at 41.43% compared to 16.43% for Johnson’s with p < 0.001. Lower bias (7.11%) was seen in palpation compared to Johnson’s (12.09%) and with more precise estimates.@*Conclusion@#Palpation method is more accurate and reliable than Johnson’s rule. Clinical palpation is easy, cost effective, simple and should be considered as a diagnostic tool for fetal weight estimation especially in rural areas. The effect modifiers are cervical dilation for palpation and engagement for Johnson’s. BMI has no effect in accuracy of estimates in both methods.


Asunto(s)
Peso Fetal , Feto , Atención Prenatal , Palpación , Proyectos de Investigación , Servicios de Salud
2.
Malaysian Journal of Medical Sciences ; : 132-138, 2019.
Artículo en Inglés | WPRIM | ID: wpr-780815

RESUMEN

@#Background: Endotracheal tube cuff (ETTc) inflation pressure is usually not regarded as an important aspect during intubation. In this study, we compared measuring ETTc pressure and pilot balloon palpation method in causing post-operative airway complications. Methods: Two hundred and ninety-two surgical patients requiring intubation were recruited into this prospective, double-blind, randomised controlled study. Group A patients had their ETTc initially inflated, checked by a cuff pressure gauge, recorded and then set to 25 cmH2O. Group B patients had their ETTc inflated using the pilot balloon palpation method. Patients were then followed up for post-operative sore throat, hoarseness and cough. Results: The overall incidence of post-operative sore throat was 39.0% versus 75.3% (P < 0.001), hoarseness 6.2% versus 15.1% (P < 0.05) and cough 7.5% versus 21.9% (P < 0.05) in Group A and B, respectively. Group A patients experienced a significant reduction in the incidence and severity of sore throat up to 24 h post-operatively (P < 0.001), hoarseness at the first hour (P = 0.004) and cough at first and 12 h post-operatively (P = 0.002). Conclusion: Adjusting the ETTc pressure to 25 cmH2O reduces post-operative sore throat, hoarseness and cough compared to pilot balloon palpation method.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA