Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Añadir filtros








Intervalo de año
1.
Indian J Ophthalmol ; 2022 Aug; 70(8): 3112-3115
Artículo | IMSEAR | ID: sea-224551

RESUMEN

The authors describe a novel technique of performing retinoscopy assisted with a smartphone (gimbalscope). We found this technique of digital retinoscopy to be useful for demonstrating and documenting retinoscopic reflexes and in addition as an easy teaching tool. This technical report explains the assembly of our smartphone-assisted retinoscope and provides examples of the range of normal and abnormal reflexes that can be captured.

2.
International Eye Science ; (12): 931-934, 2021.
Artículo en Chino | WPRIM | ID: wpr-876030

RESUMEN

@#AIM: To study the application value of digital and visual retinoscope in the detection of ametropia in adolescents.<p>METHODS:A retrospective analysis of digital visual inspection and traditional retinography test results of 69 adolescents in the ophthalmology department of our hospital from January 2019 to October 2019. SPSS 20.0 software analyzed the correlation of spherical equivalent, diopter of cylindrical power and axial direction measured by two detection methods. Taking the clinical examination results as the control, the diagnostic value was compared. <p>RESULTS: There was no statistically significant difference in the measuring of spherical equivalent, diopter of cylindrical power and axial direction between digital and visual retinoscope and traditional retinography(<i>t</i>=0.081, 1.778, 0.983, <i>P</i>=0.935, 0.077, 0.327). And there was a significant positive correlation(<i>r</i>=0.745, 0.572, 0.941,<i> P</i><0.01). At the same time, two detection methods have the same sensitivity. Digital and visual retinoscope higher than traditional retinography at the specificity, accuracy, positive predictivevalue and negative predictive value.<p>CONCLUSION: The detection of ametropia in adolescents with digital and visual retinoscope has a good correlation with traditional retinography. Compared with the latter, the former has improved for the diagnosis of ametropia, which deserves clinical attention.

3.
Chinese Medical Equipment Journal ; (6)1989.
Artículo en Chino | WPRIM | ID: wpr-588156

RESUMEN

A new retinoscope with the ultrasonic distance measure instrument is designed for directly displaying the dioptre of artificial myopia caused by retinoscopy distance.Optometrist can obtain real dioptre of the patient if only adding the direct dioptre of artificial myopia to neutral dioptre obtained at roll-back point.This instrument can obviously increase the accuracy of refraction.

4.
Journal of the Korean Ophthalmological Society ; : 283-287, 1989.
Artículo en Coreano | WPRIM | ID: wpr-75722

RESUMEN

Photorefraction was performed in 96 cases(191 eyes) after instillation of tropicamide and cyclopentolate for the purpose of screening procedure. And then refraction was also carried out by retinoscope. From this comparison study, phtorefraction provided data which were very close to those obtained from the conventional retinoscopy.


Asunto(s)
Ciclopentolato , Tamizaje Masivo , Retinoscopios , Retinoscopía , Tropicamida
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA