International Journal of Laboratory Medicine ; (12): 140-143, 2019.
Artículo en Chino | WPRIM | ID: wpr-742872

RESUMEN

Objective To evaluate the performance of hook effect of five immunoturbidimetric kits for the detection of specific proteins on biochemical analyzers.Methods Five immunoturbidimetric kits with higher market share that came from Beijing BSBE (A), Sichuan maccura (B), Shenzhen Mindray (C), Ningbo Medical System (D) and Beijing Leadman (E) were used to determine six specific proteins.A series of concentration gradient samples were prepared and tested to compare the performance of hook effect from different manufactures′kits when the analytical measurement ranges were known.Results In the five kits, the upper limits of the safe range of antigen excess about ASO, hs-CRP andβ2-MG were relatively higher in B and C.No hook effect occurred at the approximate concentration of 10 000IU/mL, 1 000mg/L and 226mg/L respectively.The highest upper limits for CysC were C and E kits, and both were greater than 112mg/L.The upper limits of the safety range for other manufacturers were more than 700mg/L about RBP except for D.The maximum upper limit of mALB was D.Hook effect did not appear at the concentration of 43 560mg/L approximately.Conclusion Different manufactures′immunoturbidimetric kits have different hook effect performance.The laboratories should verify the hook effect performance before using the kits, and select the most suitable kit to prevent hook effect.

2.
Journal of Jilin University(Medicine Edition) ; (6): 1178-1181, 2014.
Artículo en Chino | WPRIM | ID: wpr-485471

RESUMEN

Objective To measure the reconstructed cranial CT images,and to clarify the safety range of unilateral nasal transsphenoidal approach for pituitary surgery.Methods 100 normal pituitary cranial CT images were randomly selected,and the three-dimensional reconstruction was performed by using the CT images of perpendicular and parallel to the edge of the two eyes as base line, and the distance and angle in unilateral nasal transsphenoidal approach for pituitary surgery from the sagittal plane in the middle of the nasal meatus and the plane through the tip of the nose and both ends of dorsum sellae were measured,respectively. The angles and distances were compared when grouped the data by gender and age. Results Angle A1 (the angle between the tip of the nose and the tuberculum sellae and saddle back root line in the sagittal plane)in the sagittal plane of the middle nasal meatus was (11.22±1.35)°,95% confidence interval was 8.92°-13.76°degrees;the distance D1(the distance on the line between tuberculum sellae and saddle back root, and the line was formed by the plate contained the angle A1 and sellar floor)was (16.71 ± 2.07)mm,95% confidence interval was 13.11-19.93 mm.Angle A2 (the angle between the tip of the nose and the saddle back ends)which was in the plane through the tip of the nose and both ends of dorsum sellae was (8.91±1.19)°,95% confidence interval was 7.12°-10.72°;the distance D2(the distance on the line between the saddle back ends,and the line was formed by the plate contained the angle A2 and sellar floor)was (14.23±2.09)mm,95% confidence interval was 10.81-17.92 mm. The four parameter data was normally distributed,and there was no significantly statistic difference between different gender and ages (P>0.05).Conclusion The angle of the movement for unilateral nasal transsphenoidal approach for pituitary surgery operation in the sagittal plane in the middle of the nasal meatus should be less than (11.22 ± 1.35)°,and the distance of the movement should be less than (16.71±2.07)mm. The angle of the movement in the plane through the tip of the nose and both ends of dorsum sellae should be less than (8.9 1 ± 1.1 9 )°, and the distance of the movement should be less than (14.23±2.09)mm.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA