1.
Indian J Ophthalmol ; 2022 Dec; 70(12): 4152-4157
Artículo | IMSEAR | ID: sea-224743

RESUMEN

Purpose: The current study was aimed at assessment of optic disk by disk damage likelihood scale (DDLS) staging using slit?lamp biomicroscopy and optical coherence tomography (OCT) in diagnosing primary open?angle glaucoma (POAG) patients. Methods: This was a cross?sectional observational study of 106 POAG patients, which was conducted from April 2017 to April 2018. All patients underwent slit?lamp fundoscopy with a +78 D lens and high?definition (HD)?OCT, and the vertical cup disk ratios (VCDRs) were recorded. Disk size and neuroretinal rim assessment were done, and the disk was then staged using the recent version, which stages the optic nerve head (ONH) from 1 to 10 as read from the DDLS nomogram table. DDLS scores >5 indicate glaucomatous damage. Pearson coefficient was used to correlate the DDLS staging by slit?lamp biomicroscopy with best?corrected visual acuity (BCVA), intraocular pressure (IOP), disk size, and VCDR and VCDR, mean deviation, and DDLS staging by HD?OCT. Results: The mean age of the patients was 59.54 ± 6.61 years. The male: female ratio was 2:1. The mean IOP was 16.04 ± 1.97 mmHg, and BCVA was 0.72 ± 0.13 LogMAR units. The mean VCDR on 78 D slit?lamp biomicroscopy was 0.76 ± 0.09 (standard deviation [SD]) (range 0.1–0.77), whereas on HD?OCT, the mean VCDR was 0.81 ± 0.09 (SD) (range 0.07–0.81). The mean deviation on visual field testing in decibels was ?14.43 ± 3.31 (SD). The correlation coefficient between DDLS staging by slit?lamp biomicroscopy and DDLS staging by HD?OCT parameters was r = 0.96. Conclusion: There is a positive correlation between the DDLS system of optic disk evaluation on slit?lamp biomicroscopy and most of the HD?OCT evaluation parameters

2.
International Eye Science ; (12): 533-537, 2019.
Artículo en Chino | WPRIM | ID: wpr-731859

RESUMEN

@#AIM: To compare the ability of spectral-domain optical coherence tomography(SD-OCT)and slit lamp biomicroscopy to detect anterior segment findings in patients with closed globe injury.<p>METHODS: This is an observational, cross-sectional study. Sixteen patients with a closed globe injury were consecutively recruited from January 2010 to July 2015 in Huizhou Municipal Central Hospital. All patients underwent complete ophthalmic examination, including assessment of visual acuity, measurement of intraocular pressure using a noncontact tonometry, and slit lamp biomicroscopy. SD-OCT was used to examine the anterior segments of all injured eyes. Two patients had bilateral ocular injuries and received bilateral SD-OCT examinations. The OCT findings of the cornea, iris, anterior chamber and lens were recorded and compared with findings seen using slit lamp biomicroscopy.<p>RESULTS: All 18 eyes were examined by SD-OCT had hyphema occupying at least one-third of the anterior chamber volume. Sixteen eyes had corneal edema and corneal abrasion detected on both slit lamp biomicroscopy and OCT examination. OCT examination was also able to detect Descemet's membrane detachment(<i>n</i>=7), angle recession(<i>n</i>=6), lens subluxation(<i>n</i>=3)and iridodialysis(<i>n</i>=3).<p>CONCLUSION: SD-OCT was able to identify features of closed globe injury that were otherwise not visible on slit lamp biomicroscopy. SD-OCT may have advantages over clinical examination in cases of closed globe injury.

3.
Indian J Ophthalmol ; 2018 Feb; 66(2): 195-201
Artículo | IMSEAR | ID: sea-196623

RESUMEN

Current corneal assessment technologies make the process of corneal evaluation extremely fast and simple, and several devices and technologies show signs that help in identification of different diseases thereby, helping in diagnosis, management, and follow-up of patients. The purpose of this review is to present and update readers on the evaluation of cornea and ocular surface. This first part reviews a description of slit lamp biomicroscopy (SLB), endothelial specular microscopy, confocal microscopy, and ultrasound biomicroscopy examination techniques and the second part describes the corneal topography and tomography, providing up-to-date information on the clinical recommendations of these techniques in eye care practice. Although the SLB is a traditional technique, it is of paramount importance in clinical diagnosis and compulsory when an eye test is conducted in primary or specialist eye care practice. Different techniques allow the early diagnosis of many diseases, especially when clinical signs have not yet become apparent and visible with SLB. These techniques also allow for patient follow-up in several clinical conditions or diseases, facilitating clinical decisions and improving knowledge regarding the corneal anatomy.

4.
Recent Advances in Ophthalmology ; (6): 935-938, 2017.
Artículo en Chino | WPRIM | ID: wpr-657700

RESUMEN

Objeetive To investigate the detection of hemodynamiCS parameters of conjunctival microvessels by functional slit lamp biomicroscopy (FSLB) in normal adult and its clinical application values.Methods Randomly selected 16 postgraduate students aged 21 to 25 years from the Nanchang University and Zhongshan Ophthalmic Center,including 8 males and 8 females.The density,length and diameter of conjunctival microvessel and the flow velocity of arteriolar and venular blood were measured by FSLB and software program (BenoitTM,TruSoft Inc,St.Petersburg,FL,USA),as well as the indicators' characteristics of the subjects' were analyzed.Results As for subjects' right eyes,the microvascular density,length,diameter,and the arteriolar and venular blood flow velocity were no significant difference between the upper,and lower sides,as well as between nasal and temporal sides (all P > 0.05);meanwhile the microvascular density,length and diameter of the upper and lower sides were both lower than those of the nasal and temporal sides,and the differences were statistically significant (all P < 0.05),while the arteriolar and venular blood flow velocity of the upper and lower sides were both significantly higher than those of the nasal and temporal sides,and the differences were statistically significant (all P < 0.05).In addition,the changes in hemodynamics parameters of conjunctival microvessels of the left eyes and total eyes in subjects were consistent with the right eyes.Conclusion FSLB can clearly obtain hemodynamics parameters of conjunctival microvessels in healthy grown-ups,and has a promising clinical value.

5.
Recent Advances in Ophthalmology ; (6): 935-938, 2017.
Artículo en Chino | WPRIM | ID: wpr-660044

RESUMEN

Objeetive To investigate the detection of hemodynamiCS parameters of conjunctival microvessels by functional slit lamp biomicroscopy (FSLB) in normal adult and its clinical application values.Methods Randomly selected 16 postgraduate students aged 21 to 25 years from the Nanchang University and Zhongshan Ophthalmic Center,including 8 males and 8 females.The density,length and diameter of conjunctival microvessel and the flow velocity of arteriolar and venular blood were measured by FSLB and software program (BenoitTM,TruSoft Inc,St.Petersburg,FL,USA),as well as the indicators' characteristics of the subjects' were analyzed.Results As for subjects' right eyes,the microvascular density,length,diameter,and the arteriolar and venular blood flow velocity were no significant difference between the upper,and lower sides,as well as between nasal and temporal sides (all P > 0.05);meanwhile the microvascular density,length and diameter of the upper and lower sides were both lower than those of the nasal and temporal sides,and the differences were statistically significant (all P < 0.05),while the arteriolar and venular blood flow velocity of the upper and lower sides were both significantly higher than those of the nasal and temporal sides,and the differences were statistically significant (all P < 0.05).In addition,the changes in hemodynamics parameters of conjunctival microvessels of the left eyes and total eyes in subjects were consistent with the right eyes.Conclusion FSLB can clearly obtain hemodynamics parameters of conjunctival microvessels in healthy grown-ups,and has a promising clinical value.