1.
Chinese Medical Equipment Journal ; (6): 122-123,155, 2015.
Artículo en Chino | WPRIM | ID: wpr-600527

RESUMEN

Objective To explore the causes of accidental instability of SYSMEX XS-800i blood cell analyzer for WBC testing and their countermeasures.Methods Totally 10 pieces of specimen with high deviation were analyzed retrospectively, and the changes of DIFF-Y values of WBC were observed. Sysmex detergent was used to clean the pipelines including 4DL, 4DS and EPK pipes. Fluid path electromagnetic valve was checked and then repaired or replaced. Results It's proved that the results at the first time were not reliable, and there was significant differences between the results at the first and second times for DIFF-Y value, with P<0.01. The failures were eliminated after the above countermeasures were carried out.Conclusion WBC testing pipelines and electromagnetic valve of fluid path have to be cleaned periodically to eliminate the influence on DIFF-Y value of WBC and false increase of WBC counting.

2.
Indian J Med Sci ; 2011 Nov; 65(11) 469-475
Artículo en Inglés | IMSEAR | ID: sea-147798

RESUMEN

Context: Automated analyzers based on flow cytometry have evolved as an effective adjuvant diagnostic tool in malaria diagnosis. Aim: To find out the correlation of interpretive (IP) message from automated hematology analyzer XS-800i and Plasmodium infection diagnosed in peripheral smear. Settings and Design: Prospective study carried over a period of 2 years (July 2010 to June 2012). Materials and Methods: All cases with IP message of eosinophilia in Sysmex XS-800i analyzer were screened for microscopic correlation of eosinophilia and other peripheral smear findings. Results: In 24 out of 5012 patients with eosinophilia, microscopic eosinophil counts were normal. In these 24 cases, IP message in hematology analyzers was that the eosinophilia and WBC scattergram showed narrowed space between the eosinophil and neutrophil population. On careful examination of the peripheral smears of all 5012 cases, 39 cases revealed different stages of Plasmodium vivax (trophozoites, schizonts or gametocytes) in erythrocytes. Conclusion: Peripheral smears of the cases having inconsistent eosinophilia result with that of Sysmex XS-800i analyzer should be examined carefully for the presence of malaria parasites in the red blood cells. Sysmex XS-800i analyzers have moderate range of sensitivity and high degree of specificity in diagnosing malaria as spurious eosinophilia.

3.
Chinese Medical Equipment Journal ; (6)1993.
Artículo en Chino | WPRIM | ID: wpr-591897

RESUMEN

0.05).The results differentiated by Sysmex XS-800i showed excellent correlation with those by handwork.Conclusion The performance of the Sysmex XS-800i automated hematology analyzer is satisfied.