Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Añadir filtros








Intervalo de año
1.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1342-1346, 2023.
Artículo en Chino | WPRIM | ID: wpr-1009065

RESUMEN

OBJECTIVE@#To investigate the effectiveness of arthroscopic multi-point fixation with anchor and suture in the treatment of tibial insertion avulsion fracture of anterior cruciate ligament (ACL) involving the anterior root of lateral meniscus (LM).@*METHODS@#A retrospective analysis was conducted on the clinical data of 28 patients with tibial insertion avulsion fracture of ACL involving the anterior root of LM who were treated with arthroscopic multi-point fixation with anchor and suture between October 2017 and January 2023. There were 12 males and 16 females with the mean age of 26 years (range, 13-57 years). There were 20 cases of sports injury and 8 cases of traffic accident injury. In 2 cases of old fracture, the time from injury to operation was 45 days and 90 days, respectively; in 26 cases of fresh fracture, the time from injury to operation was 3-20 days (mean, 6.7 days). According to the Meyers-McKeever classification, there were 4 cases of type Ⅱ, 11 cases of type Ⅲ, and 13 cases of type Ⅳ. The preoperative Lysholm knee function score was 42.1±9.0, the International Knee Documentation Committee (IKDC) score was 40.0±7.3, and the Tegner score was 0.7±0.7.@*RESULTS@#All operations were successfully completed, and the incisions healed by first intention. All the 28 patients were followed up 5-60 months (mean, 20.4 months). During the follow-up, there was nocomplication such as infection, vascular or nerve injury, loosening or breakage of internal fixator, or stiffness of knee joint. Postoperative X-ray films showed satisfactory fracture reduction and firm fixation. All fractures healed clinically, and the healing time was 8-16 weeks (mean, 10.3 weeks). At last follow-up, Lachman test and anterior drawer test were negative. At last follow-up, Lysholm knee function score was 92.4±5.5, IKDC score was 91.6±4.4, and Tegner score was 5.2±1.1, which significantly improved when compared with preoperative scores ( t=-22.899, P<0.001; t=-29.870, P<0.001; t=-19.979, P<0.001).@*CONCLUSION@#Multi-point fixation with anchor and suture in the treatment of tibial insertion avulsion fracture of ACL involving the anterior root of LM can not only fix the LM, but also effectively reduce and fix the avulsion fracture, which can obtain good effectiveness.


Asunto(s)
Masculino , Femenino , Humanos , Adulto , Ligamento Cruzado Anterior/cirugía , Meniscos Tibiales/cirugía , Fracturas por Avulsión/cirugía , Estudios Retrospectivos , Lesiones del Ligamento Cruzado Anterior/cirugía , Resultado del Tratamiento , Artroscopía , Fracturas de la Tibia/cirugía , Articulación de la Rodilla/cirugía , Suturas , Técnicas de Sutura
2.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 658-662, 2023.
Artículo en Chino | WPRIM | ID: wpr-981648

RESUMEN

OBJECTIVE@#To explore the effectiveness of arthroscopic binding fixation using suture through single bone tunnel for posterior cruciate ligament (PCL) tibial insertion fractures in adults.@*METHODS@#Between October 2019 and October 2021, 16 patients with PCL tibial insertion fractures were treated with arthroscopic binding fixation using suture through single bone tunnel. There were 11 males and 5 females with an average age of 41.1 years (range, 26-58 years). The fractures were caused by traffic accident in 12 cases and sports in 4 cases. The time from injury to operation ranged from 2 to 10 days with an average of 6.0 days. The fractures were classified as Meyers-McKeever type Ⅱ in 4 cases and type Ⅲ in 9 cases, and Zaricznyi type Ⅳ in 3 cases. There were 2 cases of grade Ⅰ, 7 cases of grade Ⅱ, and 7 cases of grade Ⅲ in the posterior drawer test. There were 3 cases combined with lateral collateral ligament injury and 2 cases with meniscus injury. The visual analogue scale (VAS) score, Lysholm score, International Knee Documentation Committee (IKDC) score, and knee range of motion were used to evaluate knee joint function. The posterior drawer test and knee stability tester (Kneelax 3) were used to evaluate knee joint stability. The X-ray films were used to evaluate fracture reduction and healing.@*RESULTS@#All incisions healed by first intention after operation. There was no incision infection, popliteal neurovascular injury, or deep venous thrombosis of lower limbs. All patients were followed up 6-12 months, with an average of 10 months. X-ray films at 6 months after operation showed the fractures obtained bone union. There were 11 cases of grade 0, 4 cases of gradeⅠ, and 1 case of grade Ⅱin posterior drawer test, showing significant difference when compared with preoperative results ( Z=23.167, P<0.001). The VAS score, Lysholm score, IKDC score, knee range of motion, and the results of Kneelax3 examination all significantly improved when compared with preoperative results ( P<0.05).@*CONCLUSION@#For adult patients with PCL tibial insertion fractures, the arthroscopic binding fixation using suture through single bone tunnel has the advantages of minimal trauma, good fracture reduction, reliable fixation, and fewer complications. The patient's knee joint function recovers well.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Lesiones del Ligamento Cruzado Anterior/cirugía , Artroscopía/métodos , Articulación de la Rodilla/cirugía , Ligamento Cruzado Posterior/lesiones , Técnicas de Sutura , Suturas , Fracturas de la Tibia/cirugía , Resultado del Tratamiento
3.
Chinese Journal of Tissue Engineering Research ; (53): 1591-1596, 2020.
Artículo en Chino | WPRIM | ID: wpr-847923

RESUMEN

BACKGROUND: The avulsion fracture of tibial Insertion of anterior cruciate ligament needs to be operated and fixed as early as possible. At present, the open reduction (absorbable screw, hollow screw, steel wire, and titanium cable) Is commonly used in the clinical treatment plan for internal fixation, which is more traumatic and has many postoperative complications. Arthroscopic reduction and elastic (suture) Internal fixation of anterior cruciate ligament fracture has the advantages of minimally invasive, clear surgical field, high fixation accuracy, few complications, good fracture reduction and healing, meeting the biomechanical requirements, and allowing rapid recovery of joint function, but also has the disadvantages of Insufficient strength, and osteotomy. OBJECTIVE: To compare the treatment efficacy of arthroscopic technique with Fiber Tape circular fixation and open reduction and fixation for the avulsion fracture of tibial Insertion of anterior cruciate ligament. METHODS: Thirty-two patients with tibial eminence fracture at Department of Orthopedics of Shanghai China Metallurgical Hospital from January 2017 to December 2018 were enrolled. All patients signed the informed consents and the study was approved by the Ethics Committee. The patients were divided into two groups based on surgical methods: Minimally Invasive group (n=17, arthroscopic reduction and Fiber Tape circular fixation) and open group (n=15, open reduction and hollow tension screw fixation). The operation time, blood loss, and postoperative complications were recorded. The range of motion of knee joint, Lysholm score, and International Knee Documenting Committee score before operation, 1 and 6 months after surgery were recorded. X-ray film was used to evaluate fracture healing. RESULTS AND CONCLUSION: (1) All patients were followed up for 6-13 months. (2) There were no significant differences in age composition, fracture type, cause of injury or preoperative score between two groups. (3) X-ray film showed satisfactory fracture reduction after operation. There were no neurological, vascular injury or fracture displacement after surgery. The fractures healed well after 6 months. (4) There was no significant difference In the operation time and postoperative complications between two groups. The blood loss showed significant difference between two groups (P=0.036). (5) The range of motion of knee joint at postoperative 1 month In both groups was significantly larger than that at baseline (P < 0.05). The range of motion of knee joint at postoperative 6 months was significantly larger than that at postoperative 1 month (P < 0.05). The range of motion of knee joint at postoperative 1 and 6 months in the minimally invasive group was significantly larger than that in the open group (P < 0.05). (6) The Lysholm and International Knee Documenting Committee scores at postoperative 1 month in both groups were significantly higher than those at baseline (P < 0.05). The scores at postoperative 6 months were significantly higher than those at postoperative 1 month (P < 0.05). The scores at postoperative 1 and 6 months in the minimally invasive group were significantly higher than those in the open group (P < 0.05). (7) These findings suggest that the patients in both groups after undergoing surgical methods had restored motion of range with time going. Compared with open fixation, arthroscopic reduction and Fiber Tape circular fixation for treating tibial eminence fracture has less blood loss, less trauma, shorter recovery time and higher functional recovery.

4.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 860-864, 2019.
Artículo en Chino | WPRIM | ID: wpr-856513

RESUMEN

Objective: To investigate the early effectiveness of three-point suture technique in treatment of anterior cruciate ligament (ACL) tibial eminence avulsion fracture by arthroscopy. Methods: Between January 2016 and December 2017, 12 patients with ACL tibial eminence avulsion fractures underwent arthroscopic fixation of avulsion fractures with Ethibon suture using three-point suture technique. There were 9 males and 3 females, with an average of 36.4 years (range, 18-50 years). The fracture caused by traffic accident in 10 cases and sports in 2 cases. Among them, 1 patient was old fracture and 11 was fresh fracture. According to the modified Meyers-McKeever classification criteria, the fractures were rated as type Ⅲ in 7 cases and type Ⅳ in 5 cases. There were 2 cases of medial collateral ligament injury and medial meniscus injury. The preoperative International Knee Documentation Committee (IKDC) score was 37.9±4.7 and Lysholm score was 46.0±3.7. Results: All operations completed smoothly. The operation time was 45-70 minutes (mean, 61.3 minutes). The incisions healed by first intention in all patients. The hospitalization stays ranged from 4 to 9 days (mean, 5 days). All patients were followed up 3-20 months (mean, 9.3 months). The anterior drawer test, Lachman test, and axis shift test in all patients were negative after operation. At last follow-up, the IKDC score was 89.7±2.5 and Lysholm score was 90.2±1.9, which were significantly higher than those before operation ( t=-30.94, P=0.00; t=-33.03, P=0.00). At last follow-up, the X-ray films showed 9 cases of fracture anatomical reduction and 3 cases of almost anatomical reduction, and 12 cases of fracture healing. Conclusion: For ACL tibial eminence avulsion fracture, arthroscopic three-point suture technique can effectively restore the stability of knee joint and obtain satisfactory early effectiveness.

5.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 1402-1405, 2018.
Artículo en Chino | WPRIM | ID: wpr-856678

RESUMEN

Objective: To explore effectiveness of suture-bridge fixation under arthroscopy in treatment of tibial eminence avulsion fracture of anterior cruciate ligament in adolescents. Methods: Between June 2013 and October 2016, 18 adolescent patients suffered tibial eminence avulsion fracture of anterior cruciate ligament were treated by suture-bridge fixation under arthroscopy. There were 11 males and 7 females with an average age of 12.5 years (range, 5-17 years). The injury caused by bruise in 6 cases, by sprain in 4 cases, and by sport injury in 8 cases. The interval between injury and admission ranged from 2 hours to 10 months (mean, 2 months). The results of preoperative Lachman and anterior drawer tests were positive. There were 10 cases of knee pain, 4 cases of knee extension limitation, and 4 cases of knee extension without strength. According to the Meyer-McKeever classification criteria, 12 cases were type Ⅱ and 6 cases were type Ⅲ. Results: All incisions healed by first intention. All 18 patients were followed up 10-18 months after operation, with an average of 12 months. Postoperative X-ray films showed that all fractures healed after 6-12 weeks (mean, 8 weeks). The results of postoperative Lachman and anterior drawer tests were negative. At last follow-up, the Lysholm knee score was 90.1±5.0 and 93.1±6.2 for affected and unaffected sides, respectively, showing no significant difference between affected and unaffected sides( t=0.669, P=3.184[?]). There was no premature closure of skeleton or leg length discrepancy and deformity. Conclusion: For tibial eminence avulsion fracture of anterior cruciate ligament in adolescents, the suture-bridge fixation under arthroscopy is an effective method with many advantages, such as minimal invasion, reliable fixation, good fracture healing, and no need for second operation to remove implants.

6.
Chinese Journal of Sports Medicine ; (6)1983.
Artículo en Chino | WPRIM | ID: wpr-594624

RESUMEN

Objective To introduce the technique and efficacy of the treatment of avulsion fracture at tibial insertion of anterior cruciate ligament(ACL) in children through internal fixation by hollow cancellous bone screw under arthroscope.Methods December 2002 ~December 2007,internal fixation using percutaneous reduction by leverage was conducted in 68 children with avulsion fracture at tibial insertion of ACL in our hospital.In 68 children,there were 29 females and 39 males,aged 6~15 years(average age of 12 years),including 22 cases of typeⅡ(with limited knee extension)and 46 cases of type Ⅲ.The fracture was fixed by hollow titanium cancellous bone screw.Results Sixty eight cases were followed up for an average of 18 months(12~36 months).The muscle tension(mea sured by KT-2000) in injured side was recovered close to the uninjured side.Excellent reduction,solid inter nal fixation,complete healing,stable knee joint and negative Lachman and drawer tests were shown in this clinical setting.No swelling,pain and knee dysfunction were found.Impingement sign at intercondylar fossa disappeared.The patients were satisfied with their functional recovery.There was no abnormal angulation and shortness.Conclusion Treatment of avulsion fracture(type Ⅱ with limited knee extension or type Ⅲ) at tibial insertion of ACL by arthroscopic internal fixation with hollow titanium alloy cancellous bone screw could obtain accurate and reliable reduction,and avoide epiphysis injury with satisfactory functional recovery.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA