Orthopedic Journal of China ; (24)2006.
Artículo en Chino | WPRIM | ID: wpr-548753

RESUMEN

0.05).The clinical outcomes were evaluated according to improvement HSS knee joint function scoring,and the score showed an average of 87.5 points (range,71-97).[Conclusion]The dual-incision technique resulted in accurate fracture reduction with low tissue complication rate,and the medial and lateral plating treatment achieved improved stabilization which enabled mobilization of the knee joint to start immediately after surgery.Medial and lateral plating treatment with dual incisions is a safe and effective technique for Schatzker type Ⅴ tibial plateau fractures.