Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Chinese Journal of Blood Transfusion ; (12): 803-806, 2023.
Artículo en Chino | WPRIM | ID: wpr-1004745

RESUMEN

【Objective】 To analyze the distribution of unexpected antibodies in tumor patients retrospectively and explore the clinical significance. 【Methods】 Unexpected antibody screening was performed on inpatients with blood preparation and blood transfusion in our hospital from January 2004 to December 2022, with 1 176 cases tested positive, and the types of unexpected antibodies and distribution characteristics were statistically analyzed. 【Results】 Unexpected antibodies were screened in 1 176 cases, with the positive rate at 1.05% (1 176/111 483). The unexpected antibodies were mainly anti-E 16.33%(192/1 176), anti-M 7.99% (94/1 176), anti-Mur 5.70% (67/1 176) and anti-Lea 4.76% (56/1 176). Among the 1 176 cases, gastrointestinal tumors accounted for 27.99% (329/1 176), gynecological tumors accounted for 24.84% (292/1 176), respiratory tumors accounted for 16.67% (196/1 176) . 【Conclusion】 The influencing factors of unexpected antibodies in tumor patients were disease type, blood transfusion history and blood type. Therefore, it is necessary for clinical departments to carry out unexpected antibody screening and perform Rh blood type matched transfusion for tumor patients to avoid alloantibody production.

2.
Chinese Journal of Blood Transfusion ; (12): 636-639, 2022.
Artículo en Chino | WPRIM | ID: wpr-1004224

RESUMEN

【Objective】 To study the yielding rate and distribution of unexpected antibodies in blood transfusion children with thalassemia in Yunnan province, and to explore the blood transfusion strategies. 【Methods】 From January 2016 to December 2021, 298 children with thalassemia, who received blood transfusion treatment in Kunming, Xishuangbanna, Wenshan, Dehong, Yuxi and Baoshan hospitals across Yunnan Province, were selected. The unexpected antibodies of blood plasma were screened by microcolumn gel card. The samples with positive antibodies were identified for alloantibody specificity. 【Results】 Unexpected antibodies were yielded in 67 out of 298(22.48%) transfused children with thalassemia. The positive rates of unexpected antibodies in boys and girls were 16.55%(24/145) and 28.10%(43/153), respectively. The positive rates of unexpected antibodies in Han, Dai, Zhuang, Yi, Bulang, Jinuo and Miao people were 14.06%(18/128), 30.80%(32/104), 35.71%(10/28), 36.36%(8/22), 50.00%(4/8), 60.00%(3/5)and 66.67%(2/3), respectively, with statistically significant differences between each other. The positive rate of unexpected antibodies in ethnic minorities was higher than that in Han. The positive rates of unexpected antibodies in children who received the first transfusion at birth-one year old, 1~3 years old, 3~6 years old and above 6 years old were 12.50%(3/24), 10.14%(7/69), 24.54%(40/163)and 40.48%(17/42), respectively. The positive rates of unexpected antibodies in children with first transfusion after 3 years old were significantly higher than those before 3 years old. The positive rates of unexpected antibodies in children with one transfusion, 1~3, 3~10, 10~20 and more than 20 transfusions were 4.76%(1/21), 12.07%(7/58), 23.71%(23/97), 28.16%(29/103)and 36.84%(7/19), respectively, with statistically significant differences between each other. The number of blood transfusions was positively correlated with the unexpected antibody yielding. The yielding rate of unexpected antibodies in children with α thalassemia, βthalassemia, δ+ βthalassemia and untyped thalassemia was 7.50%(3/40), 17.62%(34/193), 53.70%(29/54)and 9.09%(1/11), respectively(P<0.05). The yielding rate of unexpected antibodies in transfused children with δ+ βthalassemia was the highest. And 57 unexpected antibodies of Rh blood group system were yielded, 6 anti-M antibodies, 2 anti-N antibodies and 2 undetermined. 【Conclusion】 The positive rate of unexpected antibodies in transfused children with thalassemia in Yunnan province is high. Routine antibody screening should be carried out for transfusion children with thalassemia, and blood units, compatible with ABO, Rh and MNS typing results, should be selected to ensure the safety and effectiveness of clinical blood use.

3.
Korean Journal of Blood Transfusion ; : 59-67, 2018.
Artículo en Coreano | WPRIM | ID: wpr-713984

RESUMEN

BACKGROUND: Among the results of an unexpected antibody screening test using IH-1000, ‘undeterminable’ results can be obtained. Repeated tests not only use reagents and consumables but also cause a turnaround time delay. Therefore, it is important to reduce the ‘undeterminable’ results and to determine the effects. METHODS: From January to early June, 2016, 2,872 cases/259,455 tests (1.11%) of ‘undeterminable’ were detected in the screening test. The factors considered to affect the ‘undeterminable’ were classified into four categories: ① reagent, ② consumables, ③ inspection environment & specimen, and ④ enhancing the equipment management. For data comparison, a chi-square test was conducted (95% confidence interval, 0.05 significant level). RESULTS: The incidence of ‘undeterminable’ cases decreased from 1.11% before management to 0.66% (P < 0.001) after Pool Cells management. The consumption of ‘LISS/Coombs Card’ decreased from 1.07% before management to 0.51% (P < 0.001) after management. By maintaining a clean inspection environment and strengthening sample management, the rate decreased from 1.11% before management to 0.66% (P < 0.001) after management. On the other hand, there was no difference in the incidence of ‘undeterminable’ between before and after IH-1000 management reinforcement. CONCLUSION: Among the factors predicted to affect the decrease in the incidence of ‘undeterminable’, the management of Pool Cells and keeping the inspection environment clean as well as improving sample management contributed the most to the reduced ‘undeterminable’. Improvements in the management of consumables, and removing dust from the inside of the equipment, had a positive impact. A continuous quality improvement theme has been adopted and it is helpful for managing and improving the predicted factors.


Asunto(s)
Aglutinación , Polvo , Mano , Incidencia , Indicadores y Reactivos , Tamizaje Masivo , Mejoramiento de la Calidad
4.
Korean Journal of Blood Transfusion ; : 47-53, 2015.
Artículo en Coreano | WPRIM | ID: wpr-114283

RESUMEN

BACKGROUND: The Dia antigen has been found to have a relatively higher incidence among Korean populations. However, the current popular antibody screening panels contain no Dia positive cells. To prevent hemolytic transfusion reaction, screening for unexpected antibody plus screening for Dia positive cells should be performed. In this study, we evaluate the performance of the 3% Surgiscreen Sub-code D (Ortho-Clinical Diagnostics, USA) manufactured as a 3-cell panel including Dia cell versus the ID-DiaCell I-II (DiaMed, Switzerland) as a 2-cell panel plus ID-DiaCell Dia+ (DiaMed, Switzerland) in screening for irregular red blood cell alloantibodies. METHODS: From December 13, 2013 to April 24, 2014, we tested the 3% Surgiscreen by the AutoVue Innova system and the ID-DiaCell in parallel to evaluate reagent sensitivity in detecting irregular antibodies in multi-transfused patients' plasma or serum. Identification of unexpected antibody tests was performed for positive screening results. RESULTS: Antibody-positive rates were 4.2% (79/1885) and 4.6% (87/1885) for antibody screening with the 3% Surgiscreen and the ID-DiaCell, respectively. Among the 1885 samples, 1875 (99.5%) showed concordant results between the 2 methods, while 10 results differed. From the 10 discrepancies, 1 result was positive only on the 3% Surgiscreen. The prevalence of anti-Dia antibody was 10.1% and 9.2% in the 3% Surgiscreen and the ID-DiaCell, respectively. CONCLUSION: The 3% Surgiscreen manufactured as 3-cell showed a high concordance rate ompared to standard methods. The prevalence of anti-Dia showed no difference between the 2 reagents.


Asunto(s)
Humanos , Anticuerpos , Incompatibilidad de Grupos Sanguíneos , Eritrocitos , Incidencia , Indicadores y Reactivos , Isoanticuerpos , Tamizaje Masivo , Plasma , Prevalencia
5.
Artículo en Inglés | IMSEAR | ID: sea-147163

RESUMEN

Background: The quality of blood transfusion services (BTS) is essential for the treatment of patients who need blood or blood products. BTS involve several steps, including the acquisition of the donor’s blood, blood grouping, unexpected antibody screening, blood storage, transfusion, etc. There is a need to check the effectiveness of all elements in the BTS can be assessed and monitored by an external quality assessment. Aim: To assess and evaluate the performance of ABO and Rh(D) blood grouping and unexpected antibody screening of the selected World Health Organization (WHO) South-East Asia Region Member country laboratories. Methods: WHO Collaborating Centre on Strengthening Quality of Health Laboratories (Thailand) organized a regional external quality assessment scheme for blood group serology (REQAS-BGS) between 2002 and 2008 for laboratories in countries of the WHO South-East Asia Region. Test items for ABO and Rh(D) blood groupings and unexpected antibody screening and identification were distributed three cycles per year to BTS laboratories in Bangladesh, Bhutan, India, Indonesia, Maldives, Myanmar, Nepal, Sri Lanka and Thailand. By the end of the project, a total of 20 BTS laboratories had participated for differing lengths of time. Results: It was found that 87.5%, 93.3%, 81.3%, 92.3%, 100% and 87.5% of laboratories returned the test results in 2002, 2003, 2004, 2006, 2007 and 2008, respectively. Laboratories with excellent quality or a trend of quality improvement for ABO and Rh(D) blood grouping, unexpected antibody screening and identification during the six years were 60% (12/20), 50% (10/20), 52.9% (9/17) and 81.8% (9/11), respectively. At the initiation of the scheme, most laboratories were using substandard methods for ABO and Rh blood groupings, i.e. performing only direct blood grouping alone but subsequently adopted the standard methods, i.e. performing both direct and reverse blood groupings. Conclusion: REQAS-BGS in South-East Asia countries has been useful for assessing, monitoring and improving the quality of testing. Challenges such as high costs and regulatory requirements for international shipment of blood samples could be solved by amending the regulation(s) for shipment, or establishing a national EQAS.

6.
Korean Journal of Blood Transfusion ; : 32-37, 2005.
Artículo en Coreano | WPRIM | ID: wpr-226939

RESUMEN

BACKGROUND: An unexpected antibody screening test with panel cells from abroad without Dia positive cells is common practice in most laboratories in Korea, although it is impossible to detect anti-Dia. Our laboratory have used DiaCell Dia (DiaMed Ag, Cressier, Morat, Switzerland) as one of antibody screening panel cells and only positive samples with DiaCell Dia cells have been also confirmed with Dia antigen positive panel cells from Korean Red Cross (KRC). In this study, the experiences and clinical usefulness of DiaCell Dia were evaluated. METHODS: The 26,102 pretransfusion samples were tested by DiaMed microcolumn gel assay using the LISS/Coombs card, ID-DiaCell I, II, and DiaCell Dia. The DiaMed microcolumn gel assay using the LISS/Coombs card has been used for unexpected antibody screening test with panel cells from KRC. RESULTS: The positive detection rate of unexpected antibody screening test using ID-DiaCell I and II was 0.58%(151/26, 102), and eleven samples were reactive (1+~2+) with DiaCell Dia panel cells (0.04%). However, only six(0.02%) of 11 samples were reactive(2+) with Dia positive cells from KRC. CONCLUSION: The discrepant detection rate for unexpected antibody with Dia panel cells between from DiaMed and KRC is supposed to need further study. The addition of Dia positive cells as an unexpected antibody screening panel cells is strongly recommended in case that antiglobulin phase of crossmatch is abbreviated for unimmunized patients.


Asunto(s)
Humanos , Corea (Geográfico) , Tamizaje Masivo , Cruz Roja
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA