RESUMEN
Stereotactic irradiation, either in the form of stereotactic radiosurgery [SRS] or stereotactic radiotherapy [SRT], of brain lesions requires high precision accuracy in the isocenter, the main determinants were gantry and couch rotations. It is thus necessary to evaluate the isocenter variation due to gantry and couch rotations in the particular setup for SRS/SRT. This paper describes the accuracy of Patients' immobilization and the variation in the isocenter of a Siemens PRIMUS M6/6ST linear accelerator-modified for adapting a couch-mounted radiosurgery system. The accuracy of Patients immobilization was excellent in over twenty patients with 95 setups and 2375 scalp measurements. Ninety two percent of measurements had no displacements from the baseline readings, 7% had 1 mm and one percent had 2 mm displacements. The variations in isocenter position with the table and the gantry rotation were found to be < 0.4 mm with a compounded accuracy of = 1.0 mm. The deviations of the error of readjust The Laser Target Localizer Frame [LTLF] according to the Rectilinear Phantom Pointer [RLPP] were found 0.94, 0.47 and 0.26 mm for Vertical, AP and Lateral position respectively. The mechanical characteristics including dose linearity of this unit were presented. The results of our study show that a modified linear accelerator can be used for performing SRS/SRT after careful and separate evaluation of the isocenter stability due to gantry and couch rotations
Asunto(s)
Aceleradores de Partículas/instrumentación , Garantía de la Calidad de Atención de SaludRESUMEN
A radiocirurgia é uma tecnica de irradiaçäo que nos ultimos anos vem se tornando mais frequentemente utilizada. De inicio realizada apenas em poucos e superespecializados centros, devido à extremamente sofisticada e cara aparelhagem. A introduçäo das tecnicas radiocirurgicas com o acelerador linear fez com que esse procedimento pudesse ser agora realizado na maioria dos grandescentros de radioterapia. Alguns dos requerimentos essenciais para a radiocirurgia incluem a localizaçäo acurada da lesäo a ser tratada, o calculo tridimensional da dose, a precisäo da irradiaçäo no alvo predeterminado e um acentuado gradiente de dose fora do volume-alvo. Nesse trabalho, os princípios, as indicaçöes, uma descriçäo sucinta das principais tecnicas e os resultados terapeuticos iniciais da radiocirurgia, numa variedade de patologias, säo discutidos.
Asunto(s)
Humanos , Aceleradores de Partículas/instrumentación , Cerebro/cirugía , Radiación/instrumentación , Procedimientos Quirúrgicos Operativos/tendencias , Tecnología Radiológica/métodos , BrasilRESUMEN
A radiaçäo síncrotron proporciona uma nova fonte de raios X, altamente adequada para o estudo da circulaçäo coronariana, através da técnica da subtraçäo digital (digital subtraction angiography-DSA). A eliminaçäo das imagens contrastadas decorrentes da existência de estruturas näo-vasculares, a exposiçäo do paciente níveis de radiaçäo muito abaixo dos usualmente empregados em estudos angiográficos, a possibilidade de se obter imagens de alta resoluçäo e a eliminaçäo do uso do cateter intra-arterial nos permitem antecipar sua aplicaçäo, em futuro próximo, como recurso diagnóstico eficaz, seguro e de grande valor epidemiológico. O método apresenta excelente nível de sensibilidade ao iodo intra-arterial, o que possibilita a perspectiva de visualizar as artérias coronárias mediante a injeçäo periférica intravenosa do contraste iodado
Asunto(s)
Humanos , Aceleradores de Partículas/instrumentación , Vasos Coronarios , Angiografía de Substracción Digital/instrumentación , Medios de Contraste , Enfermedad Coronaria/diagnóstico , Inyecciones IntravenosasRESUMEN
Apresentamos as grandezas dosimétricas mais importantes para o uso clínico do feixe de fótons do acelerador linear Mevatron-74. Foram feitas medidas em água e poliestireno com câmara de ionizaçäo dos seguintes parâmetros físicos: profundidade de dose máxima e dose superfície, dependência da dose com o tamanho de campo, porcentagem de dose profunda, planura e simetria de campo, assim como a verificaçäo da lei do inverso do quadrado da distância. Foram também construídas curvas de isodose de campos quadrados pelo método das linhas decrementais