Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 75
Filtrar
1.
Braz. dent. sci ; 27(1): 1-7, 2024. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-1551411

RESUMEN

Objective: The aim of the study was to report the aplicability of intraoral scanning while rubber dam isolation is in place. Material and Methods: Female patient, 50 years old, required restorative procedures on teeth 35 and 37. An intraoral scan was initially performed on both arches. Isolation was carried out from 33 to 37, tooth preparation and immediate dentin sealing were carried out. A new scan with the rubber dam in place was performed and a CAD/CAM lithium disilicate hybrid block was digitally designed, milled, crystallized and cemented under the tooth surface with the rubber dam still in position. After completing this stage, the rubber dam was removed, the occlusion was verified, presenting excellent aesthetic and functional results. Results: The absolute isolation process used in the present study works as an excellent device for gingival retraction. Conclusion: The absolute isolation can be recommended in clinical activities of intraoral scanning favoring the quality of the final result of treatments (AU)


Objetivo: O objetivo do estudo foi relatar a aplicabilidade do escaneamento intraoral sob isolamento absoluto. Material e Métodos: Paciente do sexo feminino, 50 anos, necessitou de procedimentos restauradores nos dentes 35 e 37. Uma varredura intraoral foi inicialmente realizada em ambos os arcos. O isolamento absoluto foi feito de 33 a 37, permitindo a realização do preparo dentário e selamento imediato da dentina. Um novo escaneamento com o dique de borracha colocado foi realizado e um bloco híbrido de dissilicato de lítio CAD/CAM foi projetado digitalmente, fresado, cristalizado e cimentado sob a superfície dentária ainda com o dique de borracha em posição. Após a finalização dessa etapa, o dique de borracha foi removido, a oclusão foi verificada apresentando ótimos resultados estéticos e funcionais. Resultados: O isolamento absoluto utilizado no presente estudo funciona como um excelente dispositivo para retração gengival. Conclusão: O isolamento absoluto pode ser recomendado em atividades clínicas de escaneamento intraoral favorecendo a qualidade do resultado final dos tratamentos (AU)


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Dique de Goma , Diseño Asistido por Computadora , Ajuste de Precisión de Prótesis , Tecnología Digital , Rehabilitación Bucal
2.
Odontol. vital ; (39): 5-16, jul.-dic. 2023. tab
Artículo en Español | LILACS, SaludCR | ID: biblio-1550583

RESUMEN

RESUMEN Objetivo: Comparar la cantidad y características de las prótesis dentales removibles parciales y totales, en el servicio de odontología del Hospital Nacional de Geriatría y Gerontología, en el periodo de tiempo comprendido del 1 de enero 2005 al 31 de diciembre 2008, equivalentes a 326 expedientes. Se tomó la base de datos del servicio de odontología de consulta externa especializada de los pacientes atendidos de los años 2005 al 2008, en los cuales se entregaron un total de 2786 prótesis dentales removibles. Materiales y métodos: Con base en el dato anterior se seleccionó la muestra no aleatoria a conveniencia hasta alcanzar el tamaño de 599 prótesis entregadas, examinando 326 expedientes del periodo de enero del 2005 a diciembre del 2008, con un nivel de confianza de 99% y un error de muestreo de 0.0466. La recolección de datos se realizó por medio del programa Microsoft Excel donde se utilizó una tabla en la que se anotó el número de expediente, fecha de inicio y conclusión de prótesis, tipo de prótesis, cantidad y color de prótesis, edad, género y domicilio del paciente por distrito, cantón y provincia. El procesamiento se realizó por medio de estadística descriptiva utilizando cuadros y gráficos. Resultados: Se determinó que el mayor porcentaje de rango de edad de personas que solicitaron prótesis removibles fue de 62 a 65 años, independiente si eran prótesis totales o parciales, los pacientes que requirieron dos prótesis fueron 273 de 326, en su mayoría los pacientes solicitaron prótesis totales para un total de 372 de 599 prótesis entregadas. De la guía de color utilizada en el HRBC los colores más requeridos fueron los tonos claros blanco amarillentos que corresponde al número 62 y 65; de los expedientes analizados la mayoría de los pacientes residían en San José con un total de 200 pacientes. Se concluye que el mayor porcentaje de edentulismo que se presento es el edentulismo total con un 62%, la prótesis más utilizada es la prótesis total superior removible y en su mayoría los pacientes requieren dos prótesis, con respecto al color no es concluyente para este estudio debido a los datos no disponibles en los expedientes analizados.


ABSTRACT Objective: Compare the quantity and characteristics of partial and total removable dental prostheses, in the dentistry service of the National Hospital of Geriatrics and Gerontology, in the period from January 1, 2005 to December 31, 2008. The database of the specialized outpatient dentistry service of the patients treated from 2005 to 2008 was taken, in which a total of 2786 removable dentures were delivered. Materials and methods: Based on the previous data, the non-random sample was selected for convenience until reaching the size of 599 protheses of 326 files, with a confidence level of 99% and a sampling error of 0.0466. Data collection was carried out through the Microsoft Excel program where a table was used in which the file number, date of start and conclusion of the prosthesis, type of prosthesis, amount and color of prosthesis, age, gender and address were used of the patient by district, canton and province. The processing was carried out by means of descriptive statistics using tables and graphs. Results: It was determined that the highest percentage of the age range of people who requested removable prostheses was 62 to 65 years, the patients that required two prostheses were 273 of 326. In their majority, the patients requested total prostheses for a total of 372 of 599 prostheses delivered. Of the color guide used in the HRBC, the most requested colors were the light yellowish-white tones corresponding to the number 62 and 65; of the files analyzed, most of the patients resided in San José with a total of 200 patients. Conclusion: It is concluded that the highest percentage of edentulism that is presented is total edentulism with 62%, the most commonly used prosthesis is the removable upper total prosthesis and for the most part patients require two prostheses, with respect to color it is inconclusive for this study due to data not available in the analyzed files.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Dentadura Completa/estadística & datos numéricos , Dentadura Parcial Removible/estadística & datos numéricos , Costa Rica , Ajuste de Precisión de Prótesis
3.
Braz. dent. sci ; 26(3): 1-9, 2023. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-1442902

RESUMEN

Objective: This study aims to compare the strain induced in the supporting structures of unilateral mandibular removable partial denture frameworks retained by extra-coronal attachments fabricated with three different materials. Material and Methods: Three mandibular class II digitally designed and printed acrylic models with detachable abutments were used to fabricate three removable partial denture framework with extra coronal attachments from three different materials. A total of 33 models were prepared for strain testing (n=11). Models were divided into three groups according to framework's material: porcelain fused to cobalt chromium (PFM), polyetherketoneketone (PEKK) and polyetheretherketone (PEEK) group. Unilateral load of 60 N was applied in the three groups and strains were measured around the main abutment and saddle area using strain gauge. Results: Statistical analysis was performed using Shapiro-Wilk's test and by checking data distribution. Data were found to be non-parametric and were analysed using Kruskal-Wallis test followed by Dunn's post hoc test with Bonferroni correction. PFM group showed significantly the highest strain values around abutment, slot 1 (1mm distal to the socket of the last abutment) and slot 2 (1 cm away from slot 1) respectively (843.00±23.08, 91.00±6.52 and 1274.00±65.71) than the other tested groups (p<0.05) at same tested sites respectively followed by PEKK group (384.00±37.48, 81.00±2.24 and 135.00±0.00) and PEEK group (29.00±4.18, 63.00±4.47 and 52.00±5.70). Conclusions: PEEK and PEKK for partial denture framework with extra coronal attachments are adequate alternative to PFM due to their good mechanical response applying less strain on supportive structures in free-end cases. PEEK induces lower strain magnitude on the supporting structures when compared to PEKK. (AU)


Objetivo: Este estudo tem como objetivo comparar a tensão induzida nas estruturas de suporte de estruturas de próteses parciais removíveis mandibulares unilateraisretidas por encaixes extracoronários fabricados com três materiais diferentes. Material e Métodos: Três modelos mandibulares de classe II digitalmente projetados e impressos em acrílico com pilares destacáveis foram usados para fabricar três estruturas de próteses parciais removíveis com encaixes extracoronários de três materiais diferentes. Um total de 33 modelos foram preparados para testes de deformação (n=11). Os modelos foram divididos em três grupos de acordo com o material da estrutura: porcelana fundida com cobalto-cromo (PFM), poliétercetonacetona (PEKK) e polieteretercetona (PEEK). Carga unilateral de 60 N foi aplicada nos três grupos e as deformações foram medidas em torno do pilar principal e área de sela usando medido de tensão. Resultados: A análise estatística foi realizada por meio do teste de Shapiro-Wilk e com a verificação da distribuição dos dados. Os dados mostraram-se não paramétricos e foram analisados pelo teste de Kruskal-Wallis seguido pelo de Dunn com correção de Bonferroni. O grupo PFM mostrou significativamente os maiores valores de tensão ao redor do pilar, slot 1 (1mm distal do último pilar) e slot 2 (1 cm de distância do slot 1) respectivamente (843,00±23,08, 91,00±6,52 e 1274,00±65,71) do que os outros grupos testados (p<0,05) nos mesmos locais testados, respectivamente, seguido pelo grupo PEKK (384,00±37,48, 81,00±2,24 e 135,00±0,00) e grupo PEEK (29,00±4,18, 63,00±4,47 e 52,00±5,70). Conclusão: PEEK e PEKK para estrutura de prótese parcial com encaixes extracoronários são alternativas adequadas ao PFM devido à sua boa resposta mecânica aplicando menos tensão nas estruturas de suporte em casos de extremidade livre. O PEEK induz menor magnitude de deformação nas estruturas de suporte quando comparado ao PEKK (AU)


Asunto(s)
Dentadura Parcial , Dentadura Parcial Removible , Ajuste de Precisión de Prótesis
4.
Braz. dent. sci ; 22(4): 528-537, 2019. ilus, tab
Artículo en Inglés | BBO, LILACS | ID: biblio-1024787

RESUMEN

Objetivos: Comparar o efeito de duas opções de tratamento (próteses parciais removíveis retidas por encaixe de precisão (PA-RPD) ou grampos (C-RPD) em casos de classe I inferiores de Kennedy em relação à qualidade de vida relacionada à saúde bucal (OHRQoL) e a força de mordida. Material e Métodos: O estudo incluiu 32 pacientes parcialmente desdentados, dos quais 16 receberam PA-RPD (OT Cap Attachment) e 16 pacientes receberam C-RPD. Todos os pacientes de ambos os grupos foram solicitados a preencher o questionário OHRQoL após 1 semana (linha de base), 3 meses, 6 meses e 12 meses após a inserção da prótese. A força de mordida foi medida usando o i-load Star Sensor uma semana, 3 meses, 6 meses e 1 ano após a inserção parcial da prótese em todos os pacientes dos dois grupos. A análise estatística compreendeu o teste U de Mann Whitney, teste de Friedman, teste de Dunn e teste do qui-quadrado. Resultados: Os resultados da OHRQoL revelaram que, no período basal, 3 meses e 6 meses, o PA-RPD apresentou um escore total médio mais baixo estatisticamente significativo do OHIP-14 do que o C-RPD. No entanto, após 12 meses, não houve diferença estatisticamente significante entre os escores totais do OHIP-14 nos dois grupos. Em relação à força de mordida, não houve diferença estatisticamente significante entre os dois grupos. Conclusão: Dentro das limitações deste estudo, concluiu-se que a OHRQoL do PARPD e do C-RPD era comparável após 12 meses. Da mesma forma, a força de mordida foi a mesma para as duas opções de tratamento.(AU)


Objective: To compare the effect of two treatment options in mandibular Kennedy class I cases regarding oral health related quality of life (OHRQoL) and the biting force, removable partial dentures retained by either precision attachment (PA-RPD) or clasps (C-RPD). Material and Methods: The study included 32 partially edentulous patients which 16 patients received PA-RPD (OT Cap Attachment) and 16 patients received C-RPD. All the patients in both groups were asked to fill the OHRQoL questionnaire after 1 week (baseline), 3 months, 6 months and 12 months after prosthesis insertion. Biting force was measured using the i-load Star Sensor one week, 3 months, 6 months and 1 year after partial denture insertion for all patients in both groups. Statistical analysis comprised Mann Whitney U test, Friedman's test, Dunn's test and Chisquare test. Results: The results of OHRQoL revealed that at the baseline, 3 months and 6 months the PA-RPD showed statistically significant lower mean total OHIP- 14 score than the C-RPD. However, after 12 Monthes , there was no statistically significant difference between total OHIP-14 scores in the two groups. Concerning the biting force there was no statistically significant difference between the two groups. Conclusion: Within the limitations of this study it was concluded that the OHRQoL of both the PA-RPD and the C-RPD was comparable after 12 months. Similarly the biting force was the same for both treatment options. (AU)


Asunto(s)
Humanos , Fuerza de la Mordida , Abrazadera Dental , Dentadura Parcial Removible , Ajuste de Precisión de Prótesis
5.
Braz. dent. j ; 29(6): 576-582, Nov.-Dec. 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-974198

RESUMEN

Abstract Several attachment systems for mandibular implant-supported overdentures are currently available and studies are required to understand their mechanical properties. The objective of this study was to evaluate the retention force and wear characteristics of three attachment systems in a simulation of the cyclic dislodging of implant-supported overdentures. Thirty samples were fabricated and divided into 3 groups: 1-O-ring; 2-Mini Ball; and 3-Equator. A mechanical fatigue test was applied to the specimens using a servo-hydraulic universal testing machine performing 5500 insertion/removal cycles (f=0.8 Hz), immersed in artificial saliva. Retention force values ​​were obtained before and after 1500, 3000, and 5500 cycles using a speed of 1 mm/min and a load cell of 1 kN. One specimen from each group was randomly selected and analyzed by scanning electron microscopy. Two-way repeated measures ANOVA and the Bonferroni post hoc test were used for statistical analyses (α=0.05). The O-ring system remained stable during all periods tested and exhibited significantly lower retention force values than the Mini Ball and Equator systems. The Mini Ball system exhibited a significant increase in retention force after the mechanical test (baseline=21.04±3.29N; 5500 cycles=24.01±3.30N).The Equator system exhibited a significant decrease in retention force after each period tested, but the values were higher than the other systems. The type of attachment was found to influence retention force in different ways after mechanical tests. The Equator system exhibited the highest retention force values. The Mini Ball and Equator matrices produced deformation and wear on the surfaces without breakage of the polyamide rings.


Resumo Vários sistemas de encaixe para sobredentaduras mandibulares implantossuportadas estão atualmente disponíveis e estudos são necessários para entender as suas propriedades mecânicas. O objetivo deste estudo foi avaliar a força de retenção e as características de desgaste de três sistemas de encaixe por meio de uma simulação de deslocamento cíclico de sobredentaduras implantossuportadas. Trinta amostras foram fabricadas e divididas em 3 grupos: 1-O-ring; 2-Mini Ball; e 3-Equador. Um teste de fadiga mecânica foi aplicado aos espécimes utilizando uma máquina de teste universal servo-hidráulica com 5500 ciclos de inserção/remoção (f = 0,8 Hz), imersos em saliva artificial. Os valores da força de retenção foram obtidos antes e após 1500, 3000 e 5500 ciclos utilizando uma velocidade de 1 mm/min e uma célula de carga de 1 kN. Um espécime de cada grupo foi selecionado aleatoriamente e analisado por microscopia eletrônica de varredura. O teste de Análise de Variância a dois fatores para medidas repetidas e o teste de comparações múltiplas de Bonferroni foram utilizados para análises estatísticas (α = 0,05). O sistema de O-ring permaneceu estável durante todos os períodos testados e apresentou valores de força de retenção significativamente menores do que os sistemas Mini Ball e Equator. O sistema Mini Ball apresentou um aumento significativo na força de retenção após o teste mecânico (controle = 21,04 ± 3,29N; 5500 ciclos = 24,01 ± 3,30N). O sistema Equator apresentou uma diminuição significativa na força de retenção após cada período testado, mas os valores eram maiores do que os outros sistemas. O tipo de sistema de encaixe influenciou na força de retenção de diferentes maneiras após testes mecânicos. O sistema do Equador exibiu os maiores valores de força de retenção. As matrizes dos sistemas Mini Ball e Equator produziram deformação e desgaste nas superfícies sem ruptura dos anéis de poliamida.


Asunto(s)
Humanos , Prótesis Dental de Soporte Implantado , Prótesis de Recubrimiento , Ajuste de Precisión de Prótesis , Saliva Artificial , Resistencia a la Tracción , Ensayo de Materiales , Análisis del Estrés Dental
6.
Biosci. j. (Online) ; 34(6): 1796-1804, nov.-dec. 2018. ilus
Artículo en Inglés | LILACS | ID: biblio-968979

RESUMEN

The increase in life expectancy occurred along an increase in the demand of edentulous patients for a type of rehabilitation that provides higher masticatory efficiency. Thus, implant overdentures using the ball/o-ring and bar-clip attachment systems represent a muco-supported and implant-retained prosthetic type that allows greater security, stability, and aesthetics, besides presenting a lower cost and easier hygiene. The present study aims to report a clinical case of overdenture with the o-ring retention system. In this case, the patient complained of difficulties during mastication due to instability of the mandibular complete denture, sensitivity from the superficialization of the mental foramina, dissatisfaction with aesthetics, and successive dislocations of the mandibular condyle. After clinical and radiographic evaluation, the treatment proposed was the installation of two osseointegrated implants between the mental foramina and the o-ring attachment overdenture. This prosthetic rehabilitation presents a successful clinical follow-up of 24 months, confirming the effectiveness of the treatment applied. The patient was satisfied because the implant-retained prosthesis provided benefits related to aesthetics, comfort, phonation, and mastication. It is noted that the rehabilitation performed has solved the patient's initial complaints. After the clinical case and literature review, it is concluded that overdentures using the o-ring retention system are viable alternatives and provide adequate function and aesthetics, presenting integration with the stomatognathic system.


Com o aumento da expectativa de vida, houve também o aumento da procura dos pacientes edêntulos por uma forma reabilitadora que lhes proporcione maior eficiência mastigatória. Sendo assim, as sobredentaduras sobre implantes utilizando sistemas de encaixe bola/o'ring e barra-clip representam modalidade protética mucossuportada e implantorretida que possibilita maior segurança, estabilidade e estética, além de apresentarem menor custo e facilidade para higienização. O presente trabalho tem por objetivo relatar um caso clínico de overdenture que utiliza o sistema de retenção o'ring. Neste caso, a paciente queixava-se de dificuldades durante a mastigação devido à instabilidade da prótese total inferior, sensibilidade pela superficialização dos forames mentuais, insatisfação com a estética, além de sucessivas luxações do côndilo mandibular. Após avaliação clínica e radiográfica, o tratamento proposto foi a instalação de dois implantes osseointegráveis entre os forames mentuais e overdenture com encaixes do tipo o'ring. A reabilitação protética em questão apresenta um acompanhamento clínico bem sucedido de 24 meses, comprovando a eficácia do tratamento instituído. A paciente demonstrou estar satisfeita, pois a prótese implanto-retida possibilitou benefícios relacionados à estética, conforto, fonação e mastigação. Nota-se que a reabilitação realizada atendeu às queixas iniciais da paciente. Após a realização do caso clínico e revisão de literatura, conclui-se que overdentures que utilizam o sistema de retenção o'ring são alternativas viáveis e que promovem função e estética adequadas, integrando-se ao sistema estomatognático.


Asunto(s)
Prostodoncia , Implantes Dentales , Prótesis Dental , Prótesis de Recubrimiento , Ajuste de Precisión de Prótesis
7.
West Indian med. j ; 67(1): 89-93, Jan.-Mar. 2018. graf
Artículo en Inglés | LILACS | ID: biblio-1045810

RESUMEN

ABSTRACT Tooth and bone preservation is essential to support dentures, especially for elderly patients. Retaining the existing teeth and roots for an overdenture postpones edentulism, and this is a convenient alternative to complete dentures and extraction of teeth. Root-supported overdentures attach to the roots with precision attachments. The fit of the attachment of both the denture and the roots or implants is very important for overdentures. The combination of the attachments increases the retention and stability of attachment-retained overdentures. This technique describes an alternative procedure to fabricate root-supported overdentures with combined locator and casted telescopic attachments.


RESUMEN La preservación de los dientes y los huesos es esencial para apoyar las dentaduras postizas, especialmente para pacientes de edad avanzada. Retener los dientes y raíces existentes para una sobredentadura aplaza el edentulismo, y constituye una alternativa conveniente para completar las dentaduras postizas y la extracción de dientes. Las sobredentaduras apoyadas en la raíz se unen a las raíces con aditamentos de precisión. El ajuste del aditamento tanto de la dentadura como de las raíces o implantes es muy importante para las sobredentaduras. La combinación de los aditamentos aumenta la retención y la estabilidad de las sobredentaduras retenidas por aditamento. Esta técnica describe un procedimiento alternativo para fabricar sobredentaduras ancladas en la raíz con un localizador combinado y aditamentos telescópicos fundidos.


Asunto(s)
Humanos , Femenino , Anciano , Técnica de Perno Muñón , Diseño de Dentadura/métodos , Ajuste de Precisión de Prótesis , Técnica de Impresión Dental , Prótesis de Recubrimiento
8.
Rev. odontol. Univ. Cid. São Paulo (Online) ; 28(1): 43-49, jan.-abr. 2016.
Artículo en Portugués | LILACS, BBO | ID: biblio-2636

RESUMEN

As próteses totais convencionais inferiores são as mais difíceis de adaptar, devido à perda óssea ser maior e consequentemente à baixa estabilidade e pouca retenção. Entretanto, com o aparecimento dos implantes osse-ointegráveis surgiram os tratamentos com próteses do tipo overdenture, as quais oferecem melhor estabilidade e retenção. O objetivo deste trabalho foi comparar os três principais tipos de sistemas de retenção para a pró¬tese overdenture encontrada na literatura. Para isso, foram realizadas pesquisas com os termos "overdenture"; "attachment", "implant-supported", "dental prosthesis", "denture" e "oral rehabilitation" nas bases de dados PubMed, Science Direct e Scielo. Os sistemas barra-clipe e esférico apresentaram semelhanças estatísticas quanto à retenção e estabilidade. Já o sistema magnético apresentou pouca retenção e baixa estabilidade


The conventional lower total prosthesis is the most difficult dental prosthesis to adapt in the patients mouth, due to bone loss be greater in this region, which consequently decreases stability and retention of the prosthe¬sis. However, the appearance of osseointegrated implants gave rise to treatments with overdenture prostheses, which offer better stability and retention to the prostheses. The aim of this study was to compare the three main types of overdenture prosthesis restraint systems found in the literature. For this research, we used the terms: "overdenture"; "attachment", "implant-supported", "dental prosthesis", "denture" and "oral rehabilitation" in the databases of PubMed, Science Direct and Scielo. The clip bar and spherical systems presented statistical similarities regarding retention and stability. Already, the magnetic system presented little retention and low stability


Asunto(s)
Implantación de Prótesis Mandibular , Implantación de Prótesis , Prótesis de Recubrimiento , Ajuste de Precisión de Prótesis , Rehabilitación Bucal
9.
Prosthes. Lab. Sci ; 5(20): 85-89, jul.-set. 2016. ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-859398

RESUMEN

Os medicamentos antirreabsortivos, como os bisfosfonatos, são usados para tratamento de diversas patologias ósseas. Uma de suas complicações relacionadas à Odontologia é a osteonecrose dos maxilares e o tratamento conservador deve ser a primeira opção. Em casos de pacientes total ou parcialmente edêntulos que fazem uso de medicamentos desta classe, as próteses são mais convenientes para reabilitação. Sabemos que estética é um dos fatores de maior relevância para o paciente, o que torna cada vez mais difícil a aceitação de próteses que contenham grampos, como as próteses parciais removíveis e que, por mais criterioso que seja o planejamento, a associação de suporte, retenção, estabilidade e estética sempre deixa a desejar. O objetivo deste relato de caso foi mostrar uma reabilitação sem a instalação de implantes, a prótese parcial removível, com encaixe de precisão em paciente que faz uso do medicamento e que prezava por uma estética satisfatória.


Antiresorptive drugs such as bisphosphonates are used to treat several bone diseases. Their complication related to Dentistry is osteonecrosis of the jaw and a conservative treatment should be the first option. In cases of total or partially edentulous patients that make use of this class of medication prostheses are more convenient for rehabilitation. It is known that aesthetics is one of the most important factors for the patient and this hampers the acceptance of prostheses with staples such as removable partial dentures. And it doesn't matter how judicious the planning the association of retention, support, stability and aesthetics always falls short. The objective of this report was to present rehabilitation without implant installation using removable partial denture with precision fit in a bisphosphonates who wished a satisfactory aesthetic outcome.


Asunto(s)
Humanos , Femenino , Anciano , Ajuste de Precisión de Prótesis , Dentadura Parcial Removible , Difosfonatos , Estética Dental , Osteonecrosis
10.
The Journal of Advanced Prosthodontics ; : 411-416, 2016.
Artículo en Inglés | WPRIM | ID: wpr-180730

RESUMEN

Patients who underwent resection of maxilla due to benign or malignant tumor, or accident will have defect in palatal area. They get retention, support and stability from remaining tissues which are hardly optimal. The advantage of swing-lock attachment design is having multiple contacts on labial and lingual side of the abutment teeth by retentive strut and palatal bracing component. Because the force is distributed equally to abutment teeth, abutment teeth of poor prognosis can be benefited from it. It is also more advantageous to cover soft tissue defects which are hard to reach with conventional prosthesis. A 56-year-old female patient who had undergone a maxillectomy due to malignant melanoma complaining of loose and unstable surgical obturator. Surveyed crowns were placed on #12, 26, and 27. Teeth #11, 21, 22, and 23 had lingual rest seat and #24 had mesial rest seat to improve stability and support of the obturator. This clinical report presents the prosthetic management of a patient treated with obturator on the maxilla using swing-lock attachment to the remaining teeth.


Asunto(s)
Femenino , Humanos , Persona de Mediana Edad , Tirantes , Coronas , Ajuste de Precisión de Prótesis , Maxilar , Melanoma , Obturadores Palatinos , Pronóstico , Prótesis e Implantes , Diente
11.
Rev. estomatol. Hered ; 24(3): 186-193, jul.-sept.2014. ilus
Artículo en Español | LILACS, LIPECS | ID: lil-781717

RESUMEN

El procedimiento para la elaboración de una prótesis atornillada de arco completo sobre implantes (PAACI), requiere como requisito mecánico fundamental un acoplamiento y ajuste pasivo para garantizar un adecuado comportamiento biomecánico de dicha prótesis a largo plazo. El proceso de confección de una infraestructura para una PAACI que brinde una pasividad adecuada es minucioso y requiere el uso de materiales de alta precisión, los procedimientos clínicos y de laboratorio deben ser cuidadosos para minimizar las deficiencias de éstos y llevar a buen término el trabajo final. El presente artículo muestra un reporte de caso donde se plantea la utilización de un modelo de trabajo pasivo mediante la verificación intraoral para corregir las limitaciones de los materiales utilizados y reducir los procedimientos clínicos y de laboratorio...


The use of a verification jig and a passive master model for the preparation of implant-supported full-arch prosthesis: a case report. In order to achieve long term prognosis, the fabrication of a implant-supported full-arch prosthesis (ISFAP) should follow principles of mechanical coupling and passive fitting. This is achieved through the use of highprecision techniques and materials for both chair side and laboratory to minimize shortcomings and get an adequate result. This article reports the use of a verification jig to confirm passive fi t. The passive working model is tried intraorally to correct for possible errors, and thereby reduces chair time and the need to send the case out for numerous laboratory corrections...


Asunto(s)
Humanos , Masculino , Persona de Mediana Edad , Ajuste de Precisión de Prótesis , Implantación Dental , Prótesis Dental de Soporte Implantado
12.
Pakistan Oral and Dental Journal. 2014; 34 (1): 184-189
en Inglés | IMEMR | ID: emr-157693

RESUMEN

Dentists are challenged to create solutions for problems that patients present from chipped or missing teeth, a collapsed bite, or teeth that are irregular or misshapen. A clear diagnosis of the condition often is required for a proper treatment planning. The diagnostic cast helps the dentist to evaluate the condition of the patient's oral condition and for the diagnostic purposes. Casts may also be used as education tools for dentists as they explain characteristics of a patient's bite or particular dental needs. They can also show how a restoration will look when the work is complete


Asunto(s)
Humanos , Dentadura Parcial Fija , Ajuste de Precisión de Prótesis , Diseño de Dentadura , Equipo para Diagnóstico , Preparación del Diente
13.
ImplantNews ; 11(6): 756-760, 2014. tab
Artículo en Portugués | LILACS, BBO | ID: lil-743136

RESUMEN

Objetivo: deste trabalho foi comparar as tensões transmitidas ao osso peri-implantar em diferentes sistemas de retenções de overdentures mandibulares e maxilares retidas por implantes. Material e métodos: a busca dos trabalhos publicados foi realizada na base de dados PubMed/Medline, entre janeiro de 2002 e agosto de 2014. A seleção dos estudos relevantes foi realizada de acordo com os critérios de inclusão e exclusão. Os dados foram extraídos por dois revisores independentes. Resultados: um total de 140 artigos foi encontrado, sendo que, após a aplicação dos critérios de inclusão e exclusão, foram selecionados 21 artigos. Oito estudos utilizaram extensiometria, cinco avaliaram as tensões por meio da fotoelasticidade e sete realizaram elementos finitos. Apenas um estudo in vivo foi selecionado. O sistema de retenção mais comumente avaliado foi o O-ring (18/21). O sistema O-ring individualizado distribuiu melhor as forças para o tecido ósseo peri-implantar, quando comparado com o sistema barra-clipe. Conclusão: o presente estudo não encontrou evidências suficientes a respeito do melhor mecanismo de retenção de overdentures. As metodologias testadas nos estudos selecionados devem ser validadas por outras análises complementares e utilizadas como guia para a realização de estudos clínicos futuros.


Objective: to the purpose of this study was to compare the stress distribution in the peri-implant hard tissue on different attachment systems for mandibular or maxillary implant-retained overdentures. Material and methods: the search for published studies was performed on PubMed/Medline database covering the period of January 2000 to April 2014. The selection of the eligible studies was performed according to including and excluding criteria. Results: a total of 140 studies were screened and according to the search strategy, 21 studies were selected for this review. Eight studies perfomed strain-gauge analysis, 5 evaluated the stress distribution though photoelastic test and 7 performed tridimensional fi nite element analysis. Only one study in vivo was included. Non-splinted O-rings showed better stress distribution than other bar-clip attachment systems. Conclusions: the present study did not fi nd suffi cient evidences regarding the most indicated attachment system for overdentures with better stress distribution for the peri-implant hard tissue. The methodologies analyzed should be complemented with other tests and used as a tool for further clinical studies.


Asunto(s)
Implantes Dentales , Ajuste de Precisión de Prótesis
14.
ImplantNews ; 11(4): 505-508, 2014. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-730890

RESUMEN

A reabilitação com implantes da maxila desdentada é muitas vezes dificultada pela reabsorção óssea excessiva em sua região anterior, após a perda dos dentes, levando a um suporte labial deficiente. As overdentures são recomendadas para estes casos pela presença da flange vestibular, que se estende até o fundo de vestíbulo labial e proporciona maior suporte ao lábio do paciente. O objetivo deste estudo foi apresentar o caso clínico de um paciente reabilitado com overdenture suportada por implantes e fixada pelo sistema de encaixes MK1. Durante exame clínico inicial, foi identificada a ausência de suporte labial para proporcionar a estética labial necessária para a resolução do caso com próteses fixas totais convencionais suportadas por implantes (prótese/protocolo). A overdenture suportada por implantes dentários permitiu o restabelecimento do suporte labial perdido pelo paciente, contribuindo para a boa estética facial final do caso e o restabelecimento da função mastigatória. O sistema de encaixes MK1 também proporcionou o conforto de uma prótese fixa, sem cobertura palatina, mas com fácil dispositivo para sua remoção, facilitando a higienização adequada.


Severe bone resorption of the edentulous anterior maxilla leads to deficient upper lip support and difficult implant rehabilitation. Overdentures are recommended because of the presence of the anterior flange extension that provides adequate lip support. This study present a clinical case of an edentulous patient rehabilitated with an overdenture supported by dental implants and associated with the MK1 precision attachment system. Deficient upper lip support was diagnosed during clinical exam preventing treatment with an implant-fixed dental prosthesis. The use of the MK1 attachment system on the implant-supported overdentures allowed the adequate upper lip support that the patient needed, contributing to the final facial esthetics and the reestablishment of masticatory function. The attachment system also provided characteristics of an implant-fixed restoration, without palatal covering and also provided easy access for adequate oral hygiene procedures.


Asunto(s)
Humanos , Femenino , Adulto , Implantes Dentales , Prótesis Dental , Ajuste de Precisión de Prótesis , Prótesis de Recubrimiento
15.
In. Carreiro, Adriana da Fonte Porto; Batista, André Ulisses Dantas. Prótese parcial removível contemporânea. São Paulo, Santos, 2013. p.313-328, ilus. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-708398
16.
Full dent. sci ; 4(15): 452-457, June 18, 2013. ilus
Artículo en Portugués | LILACS, BBO | ID: biblio-850879

RESUMEN

Atualmente, a utilização de próteses fixas e/ou implantes osseointegrados é o tratamento almejado pela maioria dos pacientes parcialmente edêntulos. No entanto, dependendo da condição periodontal dos dentes remanescentes, bem como da condição óssea do espaço protético, a reabilitação oral com esses tratamentos torna-se limitada ou contraindicada. Nesses casos, a utilização de próteses parciais removíveis com encaixes torna-se importante alternativa para a reabilitação estética e funcional. Os encaixes são dispositivos mecânicos compostos por duas partes (macho-fêmea), uma situada internamente em relação à outra, que atuam como retentor direto, propiciando retenção, suporte e estabilidade às próteses dentárias. Esses dispositivos podem ser classificados como intra ou extracoronários, considerando o seu posicionamento em relação ao dente pilar. No entanto, independentemente do tipo de encaixe selecionado, a associação entre as próteses parciais fixa e removível deve ser realizada respeitando-se os princípios biomecânicos de ambas. Sendo assim, o objetivo deste estudo foi revisar e discutir a literatura quanto às implicações clínicas e laboratoriais da associação entre próteses parciais fixas e removíveis por intermédio de encaixes


Nowadays, the fixed partial dentures and/or dental implants is the most requested treatmentby the majority of partially edentulous patients. However, depending on the periodontal condition of the remaining teeth, as well as the bone condition of the prosthetic space, the oral rehabilitation with these treatments may be limited or even contraindicated. In such cases, the use of removable partial dentures associated to attachments becomes an important alternative for aesthetic and functional rehabilitation. Attachments are mechanical devices consisted of two parts (patrix-matrix), one placed inside another, which act as direct retainer, providing retention, support and stability to the dentures. These devices can be classified as intra or extracoronal attachments, considering their position in relation to the abutment tooth. However, regardless the type of attachment, the association between fixed and removable partial dentures should be performed respecting the biomechanical principles of both. Therefore, the purpose of this study was to review and discuss the literature about the clinical and laboratory implications of the association between fixed and removable partial dentures by means of attachments


Asunto(s)
Continuidad de la Atención al Paciente , Diseño de Dentadura , Ajuste de Precisión de Prótesis , Dentadura Parcial Removible , Fenómenos Biomecánicos
17.
Full dent. sci ; 4(14): 288-293, jan.-mar. 2013. ilus
Artículo en Portugués | LILACS, BBO | ID: lil-681704

RESUMEN

Nos dias atuais os implantes com conexão tipo Cone Morse estão cada vez mais sendo utilizados como eleição para a reposição de dentes ausentes. Apesar da variedade de componentes protéticos disponíveis no mercado ainda existem algumas limitações com relação à união prótese-implante. Este artigo visa apresentar as dificuldades e limitações das próteses implanto-retidas com conexões tipo Cone Morse (com indexador) em casos onde a cirurgia de colocação do implante não foi bem sucedida; uma das alternativas propostas para a resolução destes casos conhecida como técnica do encaixe tubo-parafuso, parafuso transversal ou parafuso lateral. Utilizando tal dispositivo foi possível a composição e adaptação satisfatória da prótese fixa implanto-retida, permitindo atender às necessidades da paciente, devolvendo a função e a estética


From a recent perspective the morse-taper dental implants connections are increasingly being used as an alternative for replacement of a missing teeth. Nevertheless, there are a large variety of prosthetic components available on the market with some limitations regarding the final prothesis. This article demonstrated the difficulties and limitations of prosthesis implant-retained connections when using morse-taper implants (with a prosthetic index) case in which the surgical placement of the implant wasn’t successfully performed. The alternative to overcome this scenario was the technique using the tube screw over the top of a mini abutment component. It was possible to manufacture and to have satisfactory adaptation, achieving the satisfaction of the patient, restoring function and esthetics


Asunto(s)
Ajuste de Precisión de Prótesis , Implantes Dentales , Diseño de Dentadura/métodos , Prótesis Dental de Soporte Implantado , Rehabilitación Bucal/métodos , Rehabilitación Bucal
18.
Journal of Mashhad Dental School. 2013; 36 (4): 259-270
en Persa | IMEMR | ID: emr-140468

RESUMEN

Considering to patient's complications with conventional denture in the lower arch, the requirement of a denture with more efficacy and cheaper than conventional ones, is definite. One of the most conventional ones is an overdenture with 2 implant. The purpose of this study was comparison of four types of different attachment systems including two prefabricated and 2 castable attachments. Four groups with 6 numbers of attachments [Superflex ball, locator, castable Ball on bar, castable Bar] were selected. 2 castable groups were casted; these attachments were put on implant fixtures. Then a Cr-Co framework was made. It was put on cast and attachments and an acrylic base was made on this assembly. All the samples were put in universal testing machine and a tension force of 50 Newton was loaded to seprate framework from cast. The tension force was recorded. After data collection, the data were analyzed through SPSS version 16 by One-Way ANOVA and Teukey test. Results showed that retention force of castable ball on bar [35. 31N] was the greatest followed by ball [33.33N, P=0.007], Locator [20.90N] and castable bar [14.74N], respectively [P<0.001]. Castable ball on bar was comparable to ball regarding the retentive force. Therefore this cheap attachment could be used in patients instead of prefabricated one. These attachments have more retention compared to locators which are expensive. When less retention is needed, castable bar can be used, and when more retention is needed, castable ball on bar is recommended


Asunto(s)
Implantes Dentales , Retención de Dentadura , Ajuste de Precisión de Prótesis
19.
Journal of Periodontal & Implant Science ; : 12-17, 2013.
Artículo en Inglés | WPRIM | ID: wpr-18705

RESUMEN

The purpose of this review is to examine the performance of attachments used in implant-supported overdenture (IOD) in both clinical and in vitro settings and report the compiled findings, comparisons, and trends in the research literature. Articles published in PubMed on IOD attachment systems and performance were reviewed. Non-original articles were excluded. For each article included, the type of study, number of implants, number of attachment systems, and study outcome were recorded. Of the 283 articles found, 158 met the inclusion criteria. Ninety-four articles were clinical studies and 64 articles were in vitro studies. Studies on retention were the most common for in vitro studies, and four or more attachment systems were compared in most articles with significant differences in outcome. A clinical outcome of one attachment system was most common for clinical studies, while most studies had neutral outcomes overall. Ball attachment was the most commonly tested IOD attachment system. The trend in the literature showed that there is a large discrepancy between the study designs and outcomes between the clinical and the in vitro studies for IOD. Further clinical studies that can validate in vitro research should be encouraged to address this discrepancy between the two areas.


Asunto(s)
Implantes Dentales , Ajuste de Precisión de Prótesis , Prótesis de Recubrimiento , Retención en Psicología
20.
Stomatos ; 17(33): 51-59, Jul.-Dec. 2011. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: lil-693957

RESUMEN

The objective of this study was to evaluate the retentive ability and weight change of two extracoronal attachments after repeated insertion/removal cycles. Material and methods: Two extracoronal attachments were used, one with plastic inserts and the other one with conventional metal-alloy. Initial retentive ability was checked under a 20kgf load cell at 5mm/min. The weight of the fixed/removable pairs was verified with an electronic mass comparator. Fixed/removable pairs were tested with an insertion/removal cycling machine, for 5800 cycles (corresponding to 5 years) at a speed of 32 rpm speed. Insertion/ removal cycles were performed under artificial saliva. Weight change and retentive ability of attachments were verified at baseline, six-month, one-year, two-year, three-year, four-year and five-year time intervals. The two-way ANOVA for repeated measurements test was used to verify possible interactions between precision attachment type and retentive ability/weight change over time. Statistically significant associations were found between attachment type and retentive ability over time (P=0.006). Metal-alloy group showed signifi cant differences between baseline and first year (P=0.005), baseline and second year (P=0.001), and between baseline and five years (P=0.035) of insertion/removal cycles. In the plastic insert group, no significant differences were found over time. No statistically significant associations were found between precision attachment types and weight change over time (P=0.643). Initial retentive ability can not be standardized for both attachments; the metal-alloy showed better performance than the plastic insert after five years. Both attachments did not show weight change after five years of simulated use.


O objetivo deste estudo foi avaliar a capacidade retentiva e a alteração do peso de dois encaixes extracoronários após repetidos ciclos de inserção e remoção. Materiais e métodos: Dois encaixes extracoronários foram usados, um com fêmea em plástico e o outro em metal. A capacidade retentiva inicial foi verificada em uma máquina de ensaio universal com célula de carga de 20kgf a velocidade de 5mm/min. O peso do conjunto macho/fêmea foi verificado com uma balança eletrônica. Os conjuntos macho/fêmeas foram testados em um simulador de ciclos por 5800 vezes (correspondendo a 5 anos) a uma velocidade de 32 rpm. Os ciclos de remoção e inserção foram realizados com saliva artificial. A alteração de peso e a capacidade retentiva dos encaixes foi verificada inicialmente e nos intervalos de tempo de 6 meses, um, dois, três, quarto e cinco anos. O teste ANOVA foi usado para verificar possíveis interações entre o tipo de encaixe e a capacidade retentiva/alteração de peso com o tempo de uso. Associação estatisticamente significativa foi encontrada entre o tipo de encaixe e a capacidade retentiva com o tempo de uso (P=0.006). O grupo metálico mostrou diferença significante entre o tempo inicial e o primeiro ano (P=0.005), tempo inicial e o segundo ano (P=0.001), e entre o tempo inicial e cinco anos (P=0.035) de inserção e remoção. No grupo com fêmea de plástico, não foram encontradas diferenças significativas. Associações estatisticamente significativas não foram encontradas entre os tipos de encaixes e a alteração de peso em tempo algum. (P=0.643). A capacidade retentiva inicial não pode ser padronizada nos dois encaixes; o grupo com fêmea em metal mostrou melhor performance retentiva que o grupo com fêmea em plástico após cinco anos. Ambos encaixes não mostraram alteração no peso após uso simulado de cinco anos.


Asunto(s)
Ajuste de Precisión de Prótesis , Materiales Dentales , Prótesis Dental , Retención de Dentadura , Ensayo de Materiales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA