Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Rev. bras. oftalmol ; 82: e0042, 2023. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1507882

RESUMEN

ABSTRACT Objective Compare the thickness of conjunctival autografts in pterygium surgery using the Moscovici dissection technique with manual dissection and assess the difficulty of the techniques. Methods In this randomized clinical trial, 30 eyes of 30 patients undergoing pterygium surgery were divided into the Moscovici Dissection Technique Group and the Manual Dissection Group. The patients were treated at the Hospital Oftalmológico Visão Laser (Santos, São Paulo, Brazil). Optical coherence tomography was performed to measure graft thickness three months postoperatively. Three images were obtained from each eye, and three measurements were taken at a distance of 1.5mm perpendicular to the limbus in each capture. The surgeon graded the difficulty of obtaining the graft with the technique performed from one (lowest difficulty) to four (highest difficulty). Results We found statistically significant difference between the difficulty of the two techniques and the mean conjunctival autograft thickness in the two groups (p=0.01 e p=0.05, respectively). The average difficulty rating for the Moscovici Dissection Technique Group (Air Group) was 1.47, while that for the Manual Dissection Group (MD group) was 2.20. The mean thickness of the three measurements was 252µ in the Air Group and 298µ in the MD Group, with medians of 250µ and 278µ, respectively. Conclusion Our study showed that the Moscovici technique results in thinner grafts and can be performed with greater surgical ease.


RESUMO Objetivo Comparar a espessura de autoenxertos conjuntivais em cirurgia de pterígio utilizando a técnica de dissecção de Moscovici com a de dissecção manual e avaliar a dificuldade das técnicas. Métodos Neste ensaio clínico randomizado, 30 olhos de 30 pacientes submetidos à cirurgia de pterígio foram divididos em um Grupo de Técnica de Dissecção de Moscovici e um Grupo de Dissecção Manual. Os pacientes foram tratados e avaliados no Hospital Oftalmológico Visão Laser (Santos, São Paulo, Brasil). A tomografia de coerência óptica foi realizada para medir a espessura do enxerto 3 meses após a cirurgia. Três imagens foram obtidas de cada olho, e três medidas foram realizadas a uma distância de 1,5mm perpendicular ao limbo em cada captura. O cirurgião classificou a dificuldade de obtenção do enxerto com a técnica realizada de um (menor dificuldade) para quatro (maior dificuldade). Resultados Encontramos diferenças estatisticamente significantes entre a dificuldade das duas técnicas e a espessura média do autoenxerto conjuntival nos dois grupos (p=0,01 e p=0,05, respectivamente). A classificação média de dificuldade para o Grupo de Técnica de Dissecção de Moscovici foi de 1,47, enquanto a do Grupo de Dissecção Manual foi de 2,20. A espessura média das três medidas foi de 252μ no Grupo de Técnica de Dissecção de Moscovici e de 298μ no Grupo de Dissecção Manual, com medianas de 250μ e 278μ, respectivamente. Conclusão Nosso estudo mostrou que a técnica de Moscovici resulta em enxertos mais finos e pode ser realizada com maior facilidade cirúrgica.


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Procedimientos Quirúrgicos Oftalmológicos/métodos , Trasplante Autólogo/métodos , Pterigion/cirugía , Conjuntiva/trasplante , Agudeza Visual , Conjuntiva/patología , Tomografía de Coherencia Óptica , Autoinjertos/patología , Microscopía con Lámpara de Hendidura , Presión Intraocular
2.
Braz. dent. j ; 24(3): 218-223, May-Jun/2013. tab, graf
Artículo en Inglés | LILACS | ID: lil-681859

RESUMEN

Use of biomaterials and light on bone grafts has been widely reported. This work assessed the influence of low-level laser therapy (LLLT) on bone volume (BV) and bone implant contact (BIC) interface around implants inserted in blocks of bovine or autologous bone grafts (autografts), irradiated or not, in rabbit femurs. Twenty-four adult rabbits were divided in 8 groups: AG: autograft; XG: xenograft; AG/L: autograft + laser; XG/L: xenograft + laser; AG/I: autograft + titanium (Ti) implant; XG/I: xenograft + Ti implant; AG/I/L: autograft + Ti implant + laser; and XG/I/L: xenograft + Ti implant + laser. The animals received the Ti implant after incorporation of the grafts. The laser parameters in the groups AG/L and XG/L were λ=780 nm, 70 mW, CW, 21.5 J/cm 2 , while in the groups AG/I/L and XG/I/L the following parameters were used: λ=780 nm, 70 mW, 0.5 cm 2 (spot), 4 J/cm 2 per point (4), 16 J/cm 2 per session, 48 h interval × 12 sessions, CW, contact mode. LLLT was repeated every other day during 2 weeks. To avoid systemic effect, only one limb of each rabbit was double grafted. All animals were sacrificed 9 weeks after implantation. Specimens were routinely stained and histomorphometry carried out. Comparison of non-irradiated and irradiated grafts (AG/L versus AG and XG/L versus XG) showed that irradiation increased significantly BV on both grafts (p=0.05, p=0.001). Comparison between irradiated and non-irradiated grafts (AG/I/L versus AG/I and XG/I/L versus XG/I) showed a significant (p=0.02) increase of the BIC in autografts. The same was seen when xenografts were used, without significant difference. The results of this investigation suggest that the use of LLLT is effective for enhancing new bone formation with consequent increase of bone-implant interface in both autologous grafts and xenografts.


O uso de biomateriais e luz em enxertos ósseos têm sido relatados. Esse trabalho avaliou a influência do laser baixa potência - LBP no volume ósseo (VO) e superfície de contato osso-implante (COI) ao redor de implantes dentários inseridos em blocos de enxerto bovino ou autólogos incorporados, irradiados ou não, em fêmures de coelho. Vinte e quatro coelhos adultos foram divididos em 8 grupos: EA: enxerto autólogo; EX: enxerto xenógeno; EA/L: enxerto autólogo + laser; EX/L: enxerto xenógeno + laser; EA/I: enxerto autólogo + implante; EX/I: enxerto xenógeno + implante; EA/I/L: enxerto autólogo + implante de titânio + laser; EX/I/L: enxerto xenógeno + implante de titânio + laser. Os animais receberam um implante de titânio após a incorporação dos enxertos. Os parâmetros de laser nos grupos EA/L e EX/L foram λ =780 nm, 70 mW, CW, 21,5 J/cm 2 ), enquanto que nos grupos EA/I/L e EX/I/L os seguintes parâmetros de laser foram utilizados: λ =780 nm, 70 mW, 0,5 cm 2 (spot), 4 J/cm 2 por ponto (4), 16 J/cm 2 por sessão, intervalo de 48 h × 12 sessões, CW, modo contato. O LBP foi repetido a cada 48 h (2 semanas). Para evitar efeito sistêmico apenas um membro de cada coelho foi duplamente enxertado. Todos os animais foram sacrificados 9 semanas após o implante. Os espécimes foram corados rotineiramente e histomorfometria foi realizada. A comparação dos enxertos não-irradiados e irradiados (EA/L versus EA e EX/L versus EX) mostrou que a irradiação aumentou significantemente (p=0,02) o VO para ambos os tipos de enxertos (p=0,05, p=0,001). A comparação dos enxertos não-irradiados e irradiados (EA/I/L versus EA/I e EX/I/L versus EX/I) mostrou um aumento significante (p=0,02) do COI nos enxertos autólogos e xenógenos sem diferença estatística. Os resultados desta investigação sugerem que o uso de LBP é efetivo para aumentar a neoformação óssea com consequente aumento do COI em enxertos autólogos e xenógenos.


Asunto(s)
Animales , Bovinos , Femenino , Conejos , Autoinjertos/trasplante , Trasplante Óseo/métodos , Implantes Dentales , Xenoinjertos/trasplante , Terapia por Luz de Baja Intensidad/métodos , Osteogénesis/fisiología , Autoinjertos/patología , Autoinjertos/efectos de la radiación , Diseño de Prótesis Dental , Materiales Dentales/química , Fémur/patología , Fémur/cirugía , Xenoinjertos/patología , Xenoinjertos/efectos de la radiación , Tamaño de los Órganos , Oseointegración/fisiología , Oseointegración/efectos de la radiación , Osteogénesis/efectos de la radiación , Dosificación Radioterapéutica , Titanio/química
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA