Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Añadir filtros








Intervalo de año
1.
Braz. J. Pharm. Sci. (Online) ; 58: e19175, 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1374572

RESUMEN

Abstract he aim of this work was to develop an oral solution of captopril at 5 mg/mL preservative-free. Two formulations were prepared, one containing sweetener (formulation 1) and the other without this excipient (formulation 2). The results found of validation parameters from analytical method performed by HPLC for captopril were, linearity 0.9998, the limit of detection 15.71 µg/mL, the limit of quantification 47.60 µg/mL, repeatability 1.05%, intermediate precision 2.42%, accuracy intraday 101,53%, accuracy inter-day 99.85%. Moreover, the results found for captopril disulfide were, linearity 0.9999, limit of detection 0.65 µg/mL, limit of quantification 1.96 µg/mL, repeatability 2.28%, intermediate precision 1.51%, accuracy intraday 101.36%, accuracy inter-day 100.29%. The appearance of formulations was clear and colorless, pH measures were 3.12 and 3.04, dosage of captopril and captopril disulfide were 99.45% and 99.82%, 0.24% and 0.12% for formulation 1 and formulation 2, respectively. The stability study demonstrated that the concentration of captopril and captopril disulfide in the formulations was > 90% and below 3%, respectively. The in vivo palatability study in animals and humans showed that Formulation 1 containing the sweetener had better acceptance. Thus, the sweetener was able to improve the unpleasant taste of the formulation


Asunto(s)
Pediatría/clasificación , Captopril/análisis , Química Farmacéutica/clasificación , Estabilidad de Medicamentos , Conservadores Farmacéuticos/farmacología , Edulcorantes , Gusto , Cromatografía Líquida de Alta Presión/métodos , Evaluación de Medicamentos
2.
Braz. j. pharm. sci ; 47(2): 339-350, Apr.-June 2011. ilus, tab
Artículo en Inglés | LILACS | ID: lil-595822

RESUMEN

This paper describes the studies performed with the candidate Certified Reference Material (CRM) of captopril, the first CRM of an active pharmaceutical ingredient (API) in Brazil, including determination of impurities (organic, inorganic and volatiles), homogeneity testing, short- and long-term stability studies, calculation of captopril content using the mass balance approach, and estimation of the associated measurement uncertainty.


Este artigo descreve os estudos realizados com o candidato a Material de Referência Certificado (MRC) de captopril, primeiro MRC de fármacos no Brasil, incluindo a determinação de impurezas (orgânicas, inorgânicas e voláteis), testes de homogeneidade, testes de estabilidade de curta e longa duração, cálculo do teor de captopril por balanço de massa e estimativa da incerteza de medição associada ao valor certificado.


Asunto(s)
Captopril/análisis , Captopril/farmacología , Captopril/química , Preparaciones Farmacéuticas/normas , Cromatografía Líquida de Alta Presión , Contaminación de Medicamentos/estadística & datos numéricos , Estudios de Evaluación como Asunto , Control de Calidad , Estándares de Referencia
3.
Braz. j. pharm. sci ; 47(2): 351-362, Apr.-June 2011. ilus, tab
Artículo en Inglés | LILACS | ID: lil-595823

RESUMEN

This paper describes the validation of a reversed-phase high performance liquid chromatography method (RP-HPLC) with diode array detection (DAD) for determination of related substances (impurities from organic synthesis and degradation products) of captopril according to the Brazilian Pharmacopeia IV. The aim of this study was to guarantee the method accuracy for quantification of related substances, an essential requisite to determine, using the mass balance approach, the captopril content in the first Brazilian certified reference material (CRM) of an active pharmaceutical ingredient (API), developed by Inmetro. The captopril instability in solution is discussed and the captopril content determined by mass balance is compared to the results from titration and differential scanning calorimetry (DSC).


Este artigo descreve a validação de método de cromatografia líquida de alta eficiência em fase reversa (CLAE-RP) com detector de fotodiodos (DAD) para determinação de substâncias relacionadas (impurezas orgânicas de síntese e produtos de degradação) de captopril segundo Farmacopéia Brasileira IV ed. Este estudo teve como objetivo garantir que o método é capaz de quantificar com exatidão o teor de substâncias relacionadas, um requisito essencial para que o teor de captopril seja determinado por balanço de massa no primeiro material de referência certificado (MRC) de fármacos brasileiro, o qual foi desenvolvido pelo Inmetro. A instabilidade do captopril em solução é discutida em detalhes e o teor de captopril determinado por balanço de massa é comparado com aqueles obtidos por titulação e por calorimetria exploratória diferencial (DSC).


Asunto(s)
Captopril/análisis , Captopril/farmacología , Captopril/aislamiento & purificación , Compuestos Químicos/métodos , Cromatografía Líquida de Alta Presión/métodos , Diagnóstico/análisis , Contaminación de Medicamentos , Control de Calidad , Química Farmacéutica/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA