Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
1.
Einstein (Säo Paulo) ; 14(3): 366-373, July-Sept. 2016. tab, graf
Artículo en Inglés | LILACS | ID: lil-796970

RESUMEN

ABSTRACT Objective: To discuss the implementation of technical advances in laboratory diagnosis and monitoring of paroxysmal nocturnal hemoglobinuria for validation of high-sensitivity flow cytometry protocols. Methods: A retrospective study based on analysis of laboratory data from 745 patient samples submitted to flow cytometry for diagnosis and/or monitoring of paroxysmal nocturnal hemoglobinuria. Results: Implementation of technical advances reduced test costs and improved flow cytometry resolution for paroxysmal nocturnal hemoglobinuria clone detection. Conclusion: High-sensitivity flow cytometry allowed more sensitive determination of paroxysmal nocturnal hemoglobinuria clone type and size, particularly in samples with small clones.


RESUMO Objetivo: Discutir as melhorias técnicas no diagnóstico e no acompanhamento laboratorial de hemoglobinúria paroxística noturna para a validação da técnica de citometria de fluxo de alta sensibilidade. Métodos: Estudo retrospectivo, que envolveu a análise de dados laboratoriais de 745 pacientes com hipótese diagnóstica e/ou acompanhamento de hemoglobinúria paroxística noturna por citometria de fluxo. Resultados: Os avanços técnicos não só reduziram o custo do ensaio, mas também melhoraram a identificação e a resolução da citometria de fluxo para a detecção de clone hemoglobinúria paroxística noturna. Conclusão: A citometria de fluxo de alta sensibilidade possibilitou a identificação do tipo e do tamanho de clone de hemoglobinúria paroxística noturna, especialmente em amostras com pequeno clone.


Asunto(s)
Humanos , Femenino , Lactante , Preescolar , Niño , Adolescente , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Adulto Joven , Citometría de Flujo/métodos , Hemoglobinuria Paroxística/diagnóstico , Antígenos CD/sangre , Estudios Retrospectivos , Sensibilidad y Especificidad , Mejoramiento de la Calidad/economía , Citometría de Flujo/economía , Citometría de Flujo/instrumentación , Citometría de Flujo/normas , Hemoglobinuria Paroxística/sangre , Anticuerpos Monoclonales/sangre
2.
Asian Pac J Allergy Immunol ; 2007 Mar; 25(1): 83-9
Artículo en Inglés | IMSEAR | ID: sea-36427

RESUMEN

In Thailand, the cost of antiretrovirals has recently been reduced more than 10 fold. Likewise strategies for a cost reduction in laboratory monitoring are warranted. This study was designed to explore if the most expensive reagent in flow cytometry based CD4+ cell monitoring, the CD4+/CD8+ monoclonal antibodies, can be reduced without a loss of accuracy. Blood samples from 55 HIV seronegative (HIV-) and 76 HIV+ subjects were analyzed for %CD4+ and %CD8+ T cells using a two color monoclonal antibody panel (BD Biosciences, CA, USA) with 3 different amounts of the recommended reagents for staining: 1) standard, 2) half, and 3) one-fourth. A significant Spearman correlation of 0.987 was shown for the % CD4+ T cell test results for one half as well as one-fourth of the recommended amount compared to the standard staining according to the manufacturer's instruction (p < 0.0001). For the % CD8+ T cell test results, the correlation between the standard and the half or one-fourth reduced staining was 0.972 (p < 0.0001). Bland-Altman analysis showed no significant bias between the results from one half or one-fourth of the recommended amount versus the standard. The sensitivity and specificity of the two methods at the CD4+ T cell count cut-off of 200 cells/microl were 93% and 100%; and 96% and 99%, respectively. Our study indicates that a reduction of the reagents to half or one-fourth of the amount recommended by the manufacturer was still able to generate reliable results for CD4+ and CD8+ T cell counts. Such an approach will significantly reduce the cost of CD4+ monitoring for resource limited settings where a flow cytometer is available.


Asunto(s)
Recuento de Linfocito CD4/economía , Ahorro de Costo , Citometría de Flujo/economía , Infecciones por VIH/inmunología , Humanos , Sensibilidad y Especificidad , Tailandia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA