Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Braz. j. biol ; 82: 1-7, 2022. tab, ilus
Artículo en Inglés | LILACS, VETINDEX | ID: biblio-1468564

RESUMEN

The emergence of multi-drug resistant (MDR) bacterial strains, which are posing a global health threat has developed the interest of scientists to use bacteriophages instead of conventional antibiotics therapy. In light of an increased interest in the use of phage as a bacterial control agent, the study aimed to isolate and characterize lytic phages from sewage effluent. During the current study, bacteriophage AS1 was isolated from sewage effluent against E.coli S2. The lytic activity of phageAS1 was limited to E.coli S2 strain showing monovalent behavior. The calculated phage titer was 3.5×109 pfu/ml. PhageAS1 was stable at a wide range of pH and temperature. The maximum stability was recorded at 37ºC and pH 7.0, while showing its normal lytic activity at temperature 60ºC and from pH 5.0 to 11.0 respectively. At temperature 70ºC, phage activity was somewhat reduced whereas, further increase in temperature and decrease or increase in pH completely inactivated the phage. From the current study, it was concluded that waste water is a best source for finding bacteriophages against multi-drug resistant bacterial strains and can be used as bacterial control agent.


O surgimento de cepas bacterianas multirresistentes (MDR), que representam uma ameaça global à saúde, desenvolveu o interesse dos cientistas em usar bacteriófagos em vez da terapia convencional com antibióticos. Diante do crescente interesse no uso de fago como agente de controle bacteriano, o estudo visou isolar e caracterizar fagos líticos de efluente de esgoto. Durante o estudo atual, o bacteriófago AS1 foi isolado de efluente de esgoto contra E. coli S2. A atividade lítica de phageAS1 foi limitada à cepa E. coli S2, apresentando comportamento monovalente. O título de fago calculado foi de 3,5 x 109 ufp/ml. PhageAS1 foi estável em uma ampla faixa de pH e temperatura. A estabilidade máxima foi registrada a 37ºC e pH 7,0, enquanto mostrou atividade lítica normal em temperatura de 60ºC e pH 5,0 a 11,0, respectivamente. Na temperatura de 70ºC, a atividade do fago foi um pouco reduzida, enquanto o aumento adicional da temperatura e a diminuição ou aumento do pH inativaram completamente o fago. Com base no estudo atual, concluiu-se que a água residual é a melhor fonte para encontrar bacteriófagos contra cepas bacterianas multirresistentes e pode ser usada como agente de controle bacteriano.


Asunto(s)
Bacteriófagos/aislamiento & purificación , Colifagos/aislamiento & purificación , Escherichia coli , Tipificación de Bacteriófagos/métodos , Aguas Residuales/análisis , Terapia de Fagos
2.
Rev. argent. microbiol ; 40(1): 72-74, ene.-mar. 2008. graf, mapas
Artículo en Inglés | LILACS | ID: lil-634578

RESUMEN

The appearance of enteric disease outbreaks associated with the use of waters considered bacteriologically suitable, calls for the search of new and more precise indicators. Samples of estuarine water were collected in order to quantify E. coli and E. coli ATCC 13706 somatic coliphages and to compare the usefulness of the latter to detect faecal contamination when the concentration of traditional indicators is not quantifiable. Statistical analyses suggested the division of sampling sites into two groups: group I and group II, according to the minor or major level of faecal pollution respectively registered. In group II a high correlation between the coliphages and E. coli (r: 0.73 p<0.01) was detected. E. coli always exceeded coliphage abundance. In group I, this relationship was statistically significant (r: 0.55 p< 0.05), coliphage counts were higher than those of E. coli and were detected in the absence of the latter. In summary, the use of E. coli ATCC 13706 somatic coliphages is proposed as a complementary tool for the diagnosis of the level of faecal contamination of estuarine waters, especially in areas of low pollution.


La aparición de brotes de enfermedades víricas entéricas asociadas al uso de aguas bacteriológicamente aptas impone la búsqueda de nuevos y más precisos indicadores de contaminación. Se recolectaron muestras de agua estuarina, donde se cuantificaron simultáneamente la bacteria E. coli y los colifagos somáticos de E. coli ATCC 13706, a fin de evaluar la utilidad de estos últimos para detectar contaminación fecal cuando la concentración de los indicadores tradicionales no es cuantificable. Los resultados estadísticos sugirieron la división de las estaciones de muestreo en dos grupos, I y II, de acuerdo con el menor o mayor nivel de contaminación fecal registrado, respectivamente. En el grupo II se detectó una alta correlación entre los recuentos de colifagos y de E. coli (r: 0,73 p<0,01). Asimismo, en este grupo la abundancia de E. coli siempre superó a la de colifagos. En el grupo I la correlación fue estadísticamente significativa (r: 0,55 p < 0,05), pero de mediana magnitud, los recuentos de colifagos superaron a los de E. coli, y éstos fueron detectados aun en ausencia de la bacteria. En conclusión, los colifagos somáticos de E. coli ATCC 13706 serían una herramienta accesoria en el diagnóstico del nivel de contaminación fecal de aguas estuarinas, sobre todo en áreas donde ésta es baja.


Asunto(s)
Colifagos/aislamiento & purificación , Heces/microbiología , Agua Dulce/microbiología , Microbiología del Agua , Argentina
3.
Biofarbo ; 13(13): 69-72, dic. 2005. tab
Artículo en Español | LILACS | ID: lil-507183

RESUMEN

Escherichia coli es el agente etiológico enterobacteriano más común causante de enfermedades diarreicas en lapoblación infantil. Por este motivo se estudió la transferencia por conjugación de genes plasmídicos de resistencia a antibióticos de bacterias E. coli provenientes de heces de niños menores de 3 años con procesos diarreicos que asistieron al laboratorio clínico delHospital materno infantil durante abril y diciembre del 2003. Se analizó el antibiograma de 44 cepas de E. colique presentó altos porcentajes de resistencia (Amoxicilina 95.55%, cotrimoxazol 68.88%, cloranfenicol51.11%). Por otra parte, las asociaciones más comunes de antibióticos fueron amoxicilina-cotrimoxazol (65%), y amoxicilina-cotrimoxazol-cloranfenicol (47,73%). Los experimentos de conjugación presentaron frecuencias entre 10-5 a 1 0-7, siendo de mayor valor para latransferencia de amoxicilina y menor para la amikacina. Los porcentajes de resistencia y las frecuencias deconjugación demuestran que la mayoría de los genes de resistencia son capaces de ser transferidos por conjugación. Lo que implica probablemente que muchosde estos genes están localizados en elementos genéticos como plásmidos y transposones.


Asunto(s)
Niño , Adhesinas de Escherichia coli/análisis , Colifagos/aislamiento & purificación , /enzimología
4.
Eng. sanit. ambient ; 9(4): 335-342, out.-dez. 2004. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-406809

RESUMEN

Neste trabalho são apresentados resultados da aplicação da fotocatálise heterogênea utilizando dióxido de titânio imobilizado sobre placa de vidro, irradiado por luz solar, para desinfecção de esgoto sanitário secundário. Utilizou-se o efluente de um reator anaeróbio/aeróbio com leito expandido de carvão ativado que trata o esgoto do Campus da USP/São Carlos, e também de contribuições domésticas. Os experimentos foram do tipo batelada, com tempo de recirculação de 4 horas. As vazões estudadas foram 15, 22,5 e 30 L/h. Foram avaliadas as remoções de matéria orgânica (DQO e COT) e a inativação de microrganismos indicadores de contaminação fecal (coliformes totais, E. coli, Clostridium perfringens e colifagos).


Asunto(s)
Aguas Residuales , Clostridium perfringens/aislamiento & purificación , Colifagos/aislamiento & purificación , Plantas de Tratamiento de Aguas Residuales/métodos , Características de Aguas Residuales , Purificación del Agua , Desinfección del Agua
5.
Indian J Exp Biol ; 2004 Nov; 42(11): 1112-6
Artículo en Inglés | IMSEAR | ID: sea-60078

RESUMEN

Twenty six thermotolerant strains resistant to high levels of chromium (50-250 microg/ml) were isolated from treated tannery effluent. They were also found resistant to multiple heavy metals and antibiotics. Majority of them were resistant to copper and bacitracin. Nine strains representing different resistance patterns were selected for plasmid profile and conjugation studies. Agarose gel electrophoresis results revealed that 6 strains harboured a single plasmid, whereas 3 strains exhibited 2 plasmid bands. Among antimicrobials, co-trimazole and bacitracin and among metals, Cu2+, Cd2+, Zn2+ and Ni2+ resistance were transferred most frequently at variable rates. However, chromium resistance was transferred in 6 strains with a frequency ranging 19-49x10(-2). Resistance to Co2+ and Hg2+ did not transfer under environmental conditions. Among the nine strains, three were found predominantly uropathogenic Escherichia coli (UPEC) serotype 04, whereas two strains were untypable. In addition, 4 transconjugants also showed a positive result after serotyping.


Asunto(s)
Antibacterianos/farmacología , Cromo/toxicidad , Colifagos/aislamiento & purificación , Conjugación Genética , Farmacorresistencia Microbiana , Escherichia coli/efectos de los fármacos , Pruebas de Sensibilidad Microbiana , Factores R , Serotipificación , Curtiembre , Temperatura , Contaminantes Químicos del Agua/toxicidad
6.
Rev. cienc. salud ; 5(1): 27-35, dic. 2001. ilus, tab, graf
Artículo en Español | LILACS | ID: lil-498123

RESUMEN

Evidence from the scientific literature suggests that coliform bacteria are not adequate indicators for fecal contamination, and the need has been expressed for development of rapid, accurate, and cost-effective techniques for determining the bacteriological quality of water. One alternative has been the use of coliphage methods. The objetive of the present study was to evaluate bacteriological water quality of sewage treated with fecal coliforms and coliphage. Water samples were collected from three stations: 1) influent, 2) middle, and 3) effluent at the Antofagasta activated sludge treatment plant. Coliform bacteria were determined using the MPN technique, and coliphage enumeration as described by Isbister et al., (1983). Escherichia coli ATCC 13706 was used as the host strain. The counts of both organisms decreased in a similar way through the different treatment steps with little variation over a one-year period. Coliphage numbers were lower than the bacteria by about one log. After the sewage treatment chlorination step the coliphage number was higher than the fecal coliforms. These differences showed that the coliphage was more resistent to chlorine than the fecal coliforms. The results suggested than the coliphage could be used as an alternate indicator in evaluation of bacteriological quality of treated sewage effluent.


Fuertes evidencias sugieren que las bacterias coliformes no son indicadores adecuados de contaminación fecal. Hay una gran necesidad por el desarrollo de una técnica más rápida, acuciosa y de bajo costo para determinar la calidad bacteriológica del agua. Los colifagos parecen ser una excelente alternativa. El objetivo de este estudio fue evaluar la calidad bacteriológica de aguas servidas tratadas por medio de los coliformes fecales y colifagos. Muestras de aguas fueron recolectadas de tres estaciones: afluente, en el medio y efluente en la planta de tratamientos de Antofagasta por lodos activados. Las bacterias coliformes fueron determinadas por la técnica del NMP y la enumeración de colifagos, como describe Isbister y col (1983). Escherichia coli ATCC 13706 fue usada como cepa huésped. Los recuentos de ambos microorganismos disminuyeron en forma similar a lo largo de las diferentes etapas del tratamiento con variaciones pequeñas durante un año, siendo el número de colifagos más bajos que los coliformes fecales en un log. Al final del tratamiento de las aguas servidas, etapa de cloración, los números de los colifagos fueron más altos que los coliformes fecales. Estos resultados sugieren que los colifagos pueden ser usados como un indicador alternativo para la evaluación de la calidad bacteriológica de las aguas tratadas.


Asunto(s)
Colifagos/aislamiento & purificación , Coliformes/análisis , Microbiología del Agua , Lodos Activados , Técnicas Bacteriológicas , Chile , Valores de Referencia , Purificación del Agua
7.
Rev. saúde pública ; 28(5): 345-8, out. 1994. tab
Artículo en Portugués | LILACS | ID: lil-141518

RESUMEN

Foram submetidas às contagens de colifagos, coliformes totais, coliformes fecais, e de estreptococos fecais, 104 amostras de água colhidas de 8 poços rasos localizados na área urbana do Município de Jaboticabal, SP, Brasil, com a finalidade de avaliar as condiçöes higiênico-sanitárias e de verificar as correlaçöes existentes entre o número de colifagos e o de bactérias indicadoras de poluiçäo fecal. Os resultados obtidos evidenciaram a ocorrência de 96 (92,3 por cento) amostras fora dos padröes bacteriológicos de potabilidade estabelecidos pelo Ministério da Saúde, mostrando ser precárias as condiçöes higiênico-sanitárias das aguás analisadas. Os achados evidenciaram a inexistência de correlaçäo entre o número de colifagos e os números de bactérias indicadoras de poluiçäo fecal


Asunto(s)
Contaminación del Agua , Colifagos/aislamiento & purificación , Criterios de Calidad del Agua , Brasil , Enterobacteriaceae/aislamiento & purificación , Agua Potable , Microbiología del Agua , Pozos de Agua
8.
Rev. saúde pública ; 25(1): 47-52, fev. 1991. tab
Artículo en Portugués | LILACS | ID: lil-94603

RESUMEN

Foram analisadas amostras de águas subterrâneas de três cemitérios localizados em áreas geologicamente distintas de Säo Paulo e de Santos, Brasil, com relaçäo às condiçöes higiênicas e sanitárias. Para as primeiras foram considerados os coliformes totais, bactérias heterotróficas, microrganismos proteolíticos e lipolíticos. Para as sanitárias foram pesquisados coliformes fecais, estreptococos fecais, clostrídios sulfito redutores, colifagos e salmonelas. Verificou-se que as águas näo apresentaram condiçöes higiênicas satisfatórias e, em alguns casos, foram encontrados níveis altos de nitrato (75,7 mg/l). A detecçäo de níveis mais elevados de estreptococos fecais e de clostrídios sulfito redutores em relaçäo aos coliformes fecais, na maior parte das amostras, parece mostrar que os dois primeiros indicadores seriam mais adequados para avaliaçäo das condiçöes sanitárias deste tipo de água. Foi detectada Salmonella apenas em uma amostra e näo foram detectados colifagos. Na análise estatística, foram encontradas correlaçöes significantes entre três indicadores de poluiçäo fecal assim como entre as contagens em placas de bactérias heterotróficas aeróbias, anaeróbias e lipolíticas. Foi observada uma relaçäo direta entre a deterioraçäo da qualidade da água e as condiçöes geológicas e hidrogeológicas do ambiente estudado, devendo este fator ser considerado para o planejamento e implantaçäo de cemitérios


Asunto(s)
Contaminación del Agua , Agua Subterránea , Prácticas Mortuorias , Salmonella/aislamiento & purificación , Microbiología del Suelo , Brasil , Clostridium/aislamiento & purificación , Enterococcus faecalis/aislamiento & purificación , Colifagos/aislamiento & purificación , Enterobacteriaceae/aislamiento & purificación
11.
Bangladesh Med Res Counc Bull ; 1976 Jun; 2(1): 12-20
Artículo en Inglés | IMSEAR | ID: sea-406

RESUMEN

Decimal dilutions of cholera phage heated in test tubes at the temperature range of 65 degrees to 70 degrees showed an erratic behaviour in that the residual counts had no relationship to the quantity of phage originally present in the tubes. If the contents of the heated tubes were decanted off and the empty tubes washed repeatedly with broth, the recovery of phage from successive washings of the tubes was much higher than what would be expected on the basis of the simple dilution effect of washings. The data presented indicate that the heating causes loose adhesion of phage to the wall of the glass tubes from where they can be detached by washing or shaking. The facts that E. coli phage T1 and also cholera phages tested with two different broths have given similar results, suggest that some general property of the phage itself is responsible for the phenomenon observed. The phenomenon appears to be different from the adsorption of phage to glass filters at lower temperature range described by earlier workers.


Asunto(s)
Técnicas Bacteriológicas , Bacteriófagos/aislamiento & purificación , Cólera/microbiología , Colifagos/aislamiento & purificación , Calor , Humanos , Vibrio cholerae/aislamiento & purificación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA