Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Braz. J. Pharm. Sci. (Online) ; 58: e20985, 2022. tab
Artículo en Inglés | LILACS | ID: biblio-1420466

RESUMEN

Abstract Diabetes is a self-managed condition with knowledge, attitudes and practices that can influence the overall treatment and outcomes delay the complications of diabetes. However, the few reported studies published point out that: low education level, poor adherence to pharmacotherapy and diet recommendations, infrequent monitoring of blood glucose, and insulin dosage regimen are associated with higher hemoglobin levels. This study aimed to assess the knowledge, adherence medication, and complexity of pharmacotherapy in T1DM patients in Brazil. A cross-sectional study was conducted involving 156 T1DM patients who were attending in primary care. Logistic regression analyses were conducted to assess the variables associated with glycemic control. The overall assessments of T1DM patients for the glycemic control were bad (121, 77.6%). However, T1DM patients with high MedTake Test (OR=2.4, CI=1.1-5.7) and Morisky-Green Test (OR= 2.5, CI=1.1-6.1), and in the use of dosage insulin (>40 units, OR=0.3, CI=0.1-0.7) and postprandial glucose (100-125mg/dl, OR=3.8, CI=1.1-14.6) had better glycemic control compared to uncontrolled patients. Glycemic control in Brazilians adults with T1DM is low. We suggested the screening patients with low MedTake and Morisky-Green Tests, increasing patient knowledge as part of a complex intervention that may lead to substantially improved treatment outcomes in primary care


Asunto(s)
Humanos , Masculino , Femenino , Persona de Mediana Edad , Pacientes/clasificación , Atención Primaria de Salud/clasificación , Brasil/etnología , Diabetes Mellitus Tipo 1/patología , Control Glucémico/efectos adversos , Centros de Salud , Estudios Transversales/métodos
2.
Rev. chil. endocrinol. diabetes ; 15(1): 29-34, 2022. ilus
Artículo en Español | LILACS | ID: biblio-1359364

RESUMEN

Los cuidados actuales de la diabetes incluyen altos niveles de tecnología y los pacientes utilizan diferentes dispositivos que pueden ayudar en su control metabólico, pero pueden impactar negativamente en su piel. Sensores de glucosa como el Freestyle, Dexcom, el Enlite de Medtronic y los sistemas de infusión continua de insulina contienen diferentes productos químicos que están en contacto directo con la piel del paciente y pueden causar una dermatitis irritativa o de contacto alérgica. Las lesiones incluyen eczema, prurito, heridas, cicatrices y cambios en la pigmentación de la piel. Los productos químicos involucrados que pueden ocasionarlas son el isobornil acrilato, N, N- dimetilacrilamida, etil cianoacrilato y colophonium, forzando a los pacientes a cambiar los sitios de infusión, el set de infusión o el sensor mismo más pronto de lo esperado, para reducir el nivel de daño en la piel. Existe gran número de productos que permiten proteger la piel y reducir el contacto de la piel con la cánula de la bomba o el sensor. Para reducir o prevenir el daño existen productos como cremas o spray y parches de hidrocoloide que actúan como barrera y existen técnicas para aplicar y retirar cuidadosamente los parches y adhesivos de los dispositivos. Una vez que las lesiones se han producido, el tratamiento incluye pomadas y a veces corticoides tópicos y/o antibióticos. Para prevenir o reducir el daño de la piel asociado al sensor y uso de la bomba de insulina, la industria que los produce debería incluir la información en relación a los productos químicos incluidos en cada dispositivo.


Diabetes care nowadays includes a high level of technology and patients use different devices which can help them in their glycemic control, but can have a negative impact on their skin. Glucose sensors such as Freestyle, Dexcom, Medtronic Enlite and also continuous subcutaneous insulin infusion systems contain different chemical products which are in direct contact with the patient's skin and can cause irritative or allergic contact dermatitis. Lesions include eczema, pruritus, wounds, scars and changes in skin pigmentation. The chemical products which can induce them are isobornyl acrylate, N, N- dimethylacrylamide, ethyl cyanoacrylate and colophonium, forcing patients to change the infusion site, set or the sensor itself, earlier than expected, in order to reduce the level of skin damage. There are a number of products which can protect the skin and reduce it's contact with the pump cannula or the sensor. To reduce or prevent damage, we have products such as barrier cream or spray films and hydrocolloid blister plasters and actions such as careful application and removal of device's patches and adhesives. Once lesions are established, treatment includes ointments and sometimes topical steroids and/ or antibiotics. In order to prevent or reduce skin damage related to sensor and insulin pump use, the manufacturers should include the information related to the chemicals included in each device.


Asunto(s)
Humanos , Enfermedades de la Piel/etiología , Sistemas de Infusión de Insulina/efectos adversos , Piel/lesiones , Automonitorización de la Glucosa Sanguínea/efectos adversos , Adhesivos/efectos adversos , Dermatitis Alérgica por Contacto/etiología , Control Glucémico/efectos adversos
3.
Rev. cuba. endocrinol ; 21(3): 269-278, sep.-dic. 2010.
Artículo en Español | LILACS, CUMED | ID: lil-584453

RESUMEN

La glucemia es factor de riesgo de infección, sin embargo, no existen evidencias suficientes que permitan utilizarla como marcador pronóstico de mortalidad en el paciente séptico crítico. Se realizó un estudio longitudinal y prospectivo, para evaluar la utilidad de la glucemia como factor pronóstico de mortalidad en pacientes sépticos críticos. Se incluyeron 206 pacientes que ingresaron de forma consecutiva en la Terapia Intensiva (piso 8) del Hospital "Hermanos Ameijeiras". La gravedad se evaluó a través de la escala Simplified Acute Physiology Score (SAPS-3). Se midió el valor diario de glucemia en ayunas durante los primeros 6 días de estadía, el valor más alto de los 3 primeros días y la diferencia de valores entre el tercer y el primer día. Se aplicó el coeficiente de correlación de Spearman para variables cuantitativas. Se estudió el valor independiente de la variable mediante varios modelos de regresión logística. Se consideró una significación estadística de p<0,05. Se encontró asociación entre el SAPS-3 y la glucemia del primer día (p=0,01). Los valores de glucemia entre vivos y fallecidos no mostraron diferencias significativas. El valor más alto de glucemia de los 3 primeros días para sobrevivientes fue de 8,41 (±3,25) mmol/L, y 8,72 (±3,04) mmol/L para los fallecidos. No hubo diferencias entre la resta de los valores de glucemia entre el tercer y el primer día entre vivos (-0,17±3,9 mmol/L) y fallecidos (0,07±2,8 mmol/L) (p=0,66). No se demostró utilidad de la glucemia como marcador pronóstico en relación con la mortalidad en pacientes con sepsis, aunque la glucemia del primer día se asoció con la gravedad(AU)


Glycemia is a infection risk factor, however, there are not enough evidences allowing its use as a prognostic marker of mortality in critical septic patients. Study includes 206 patients admitted in a consecutive way in Intensive Therapy Care (eight floor) of the "Hermanos Ameijeiras" Clinical Surgical Hospital. Severity was assessed according to the Simplified Acute Physiology Score scale (SAPS-3). The fasting daily value of glycemia was measured for the first 6 days of stay, the higher value during the 3 first days and the values difference between the third and the first day. The Spearmen's correlation coefficient was applied for quantitative variables. The independent value of the variable was studied using several logistic regression forms. A statistic significance of p<0,05 was considered. There was association between SAPS-3 and the first day glycemia (p=0,01). Glycemia among the living and death persons haven't significant differences. The higher value of glycemia of the first three days for survivors was of 8,41 (±3,25) mmol/L and 8,72 (±3,04) mmol/L for deceased. There weren't differences between the glycemia subtraction between the third and the first day among the leaving persons(-0,17 ±3,9 mmol/L) and those deceased (0,07±2,8 mmol/L) (p=0,66). It was impossible to demonstrate the usefulness of glycemia as a prognostic marker in relation to mortality in patients presenting with sepsis although glycemia of first day was associated with severity(AU)


Asunto(s)
Humanos , Factores de Riesgo , Sepsis/mortalidad , Cuidados Críticos/métodos , Control Glucémico/efectos adversos , Modelos Logísticos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA