1.
Artículo en Inglés | IMSEAR | ID: sea-40083

RESUMEN

OBJECTIVE: The purposes of the present study were to determine the dose to medical staff in interventional radiology at different locations on the body measured by thermoluminescent dosimeter (TLD) and to relate the medical staff dose to patient dose measured by the dose-area product (DAP) meter. MATERIAL AND METHOD: The present study covered 42 patients in three interventional radiology procedures with three x-ray machines. Thermoluminescent dosimeters were stuck at eight positions on the radiologist's skin during the procedure. In addition, direct reading from the DAP meter placed in front of the collimator of the x-ray tube, was recorded to estimate the patient radiation dose. RESULTS: The surface dose to the primary radiologist showed maximum value at the left forearm of 407 microGy. The ratios between the maximum interventional radiologist surface dose and patient dose are 12.88 microGy per 10 Gycm2 for transarterial oily chemoembolization TOCE (Siemens Polystar), 22.58 microGy per 10 Gycm2 for transarterial oily chemoembolization TOCE (Siemens Neurostar), 148.29 microGy per 10 Gycm2 for percutaneous transhepatic biliary drainage PTBD (Siemens Polystar) and 100.46 microGy per 10 Gycm2for endoscopic retrograde cholangiopancreatography ERCP (GE Advantx). CONCLUSION: The interventional radiologist surface dose can be estimated from the mentioned ratio if the patient dose is measured. This will help the radiologists to avoid receiving an excess dose during their work.


Asunto(s)
Humanos , Cuerpo Médico , Exposición Profesional , Dosis de Radiación , Protección Radiológica/instrumentación , Radiología Intervencionista , Dosimetría Termoluminiscente/instrumentación
2.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.459-460, graf.
Monografía en Portugués | LILACS | ID: lil-233818

RESUMEN

É apresentada uma análise de dados de doses de trabalhadores que utlizaram simultaneamente 2 ou 3 monitores de radiação individuais em locais diferentes do corpo, durante alguns anos. Os resultados mostram que é importante o uso do avental e pescoceira de chumbo no setor de hemodinâmica, assim como a manipulação correta de fontes não seladas no setor de Medicina Nuclear (MN). No setor de hemodinâmica, as doses equivalentes máximas no pulso chegam a cerca de 10mSv/mês, enquanto que as doses equivalentes máximas sob avental e sob pescoceira de chumbo atingem 0,8mSv/mês.


Asunto(s)
Equipos de Seguridad , Hemodinámica/fisiología , Monitoreo de Radiación/instrumentación , Dosimetría Termoluminiscente/instrumentación , Plomo/efectos de la radiación
3.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.497-498, tab.
Monografía en Portugués | LILACS | ID: lil-233837

RESUMEN

Em alguns endoscópicos específicos são realizadas radioescopias e radiografias com a equipe de médicos e enfermeiros próxima ao paciente. Através da simulação de exames e dosímetros termoluminescentes colocados em um fantoma antropomórfico foram determinadas as doses equivalentes em diferentes locais do corpo da pessoa que permanece na sala. Usando as normas nacionais e internacionais sobre os limites de dose recomendados foram calculados os números máximos de exames mensais e anuais recomendados às pessoas da equipe. Conclui-se que, com o uso de avental plumbífero, as altas doses equivalentes no cristalino (em média 1,67 mSv/exame) limitam o número de exames de que cada um pode participar.


Asunto(s)
Dosimetría Termoluminiscente/instrumentación , Endoscopía/estadística & datos numéricos , Dosis de Radiación , Radiografía/estadística & datos numéricos , Dispositivos de Protección de los Ojos , Exposición a la Radiación , Ropa de Protección
4.
In. Schiabel, Homero; Slaets, Annie France Frère; Costa, Luciano da Fontoura; Baffa Filho, Oswaldo; Marques, Paulo Mazzoncini de Azevedo. Anais do III Fórum Nacional de Ciência e Tecnologia em Saúde. Säo Carlos, s.n, 1996. p.499-500, graf.
Monografía en Portugués | LILACS | ID: lil-233838

RESUMEN

Apresentamos os resultados iniciais do estudo das propriedades termoluminescentes do topázio brasileiro visando o uso para fins dosimétricos. Os dados obtidos até o presente momento indicam a viabilidade do uso do topázio como dosímetro na faixa de 20mGy a 20Gy.


Asunto(s)
Dosimetría Termoluminiscente/instrumentación , Silicatos de Aluminio , Brasil , Dosis de Radiación
5.
Rev. argent. radiol ; 58(4): 291-5, oct.-dic. 1994. ilus
Artículo en Español | LILACS | ID: lil-141685

RESUMEN

El Servicio de Radiodiagnóstico del Hospital Universitario de la Universidad Federal de Río de Janeiro, juntamente con el Instituto de Radioprotección y Densitometría de la Comisión Nacional de Energía Nuclear, se encuentra desarrolllando programas en el área de garantía de calidad en radiodiagnóstico. Estas actividades contemplan como objetivo importante la optimización de las dosis. Uno de los programas en marcha comprende exámenes de fluoroscopia gastrointestinal. A fin de investigar los niveles de exposición a la radiación fueron realizadas medidas de dosis de entrada en la piel recibidas por pacientes y médicos en exámenes de esofagografía, seriografía y colon, utilizando dosímetros colocados en varias posiciones del cuerpo. En este trabajo se describe la metodología seguida y se muestran los resultados obtenidos hasta el presente. Se hace un análisis del espectro de dosis observadas en pacientes y profesionales, de acuerdo con diversos parámetros tales como ubicación de dosímetros, tiempo de exposición, técnicas empleadas, número de radiografías, etc. También se describen los pasos a seguir con el objeto de concretar la implantación de un programa de control de calidad en los exámenes mencionados


Asunto(s)
Humanos , Sistema Digestivo , Dosimetría Termoluminiscente/estadística & datos numéricos , Exposición Profesional/análisis , Fluoroscopía/efectos adversos , Investigación/métodos , Monitoreo de Radiación/métodos , Control de Calidad , Radiografía/efectos adversos , Medición de Riesgo , Rayos X/efectos adversos , Dosimetría Termoluminiscente/instrumentación , Dosimetría Termoluminiscente/métodos , Exposición Profesional/estadística & datos numéricos , Exposición Profesional/prevención & control , Investigación/estadística & datos numéricos , Monitoreo de Radiación/estadística & datos numéricos , Límite Permisible de Riesgos Laborales , Control de Calidad , Tecnología Radiológica/estadística & datos numéricos , Tecnología Radiológica/instrumentación , Rayos X
6.
Acta cancerol ; 24(1): 30-1, mar. 1994. ilus
Artículo en Español | LILACS, LIPECS | ID: lil-132517

RESUMEN

Se describe el proceso de diseño y construcción de una interface para comunicar un equipo de Termoluminiscencia (TLD) con una computadora personal (PC) de modo que la unidad TLD, la interface y la computadora funcionen como un espectrómetro termoluminiscente.


Asunto(s)
Microcomputadores , Dosimetría Termoluminiscente/instrumentación , Dosimetría Termoluminiscente , Planificación de la Radioterapia Asistida por Computador , Planificación de la Radioterapia Asistida por Computador/instrumentación , Planificación de la Radioterapia Asistida por Computador/tendencias , Planificación de la Radioterapia Asistida por Computador
7.
Fisioter. mov ; 6(1): 33-8, 1993. ilus
Artículo en Portugués | LILACS | ID: lil-152304

RESUMEN

Constataçöes clínicas däo ensejo à revisäo de dosimetria em laser. O artigo mostra que o equacionamento físico está conforme com resultados práticos, indicando cuidados até agora näo levados em consideraçäo na escolha de equipamentos, bem como as densidades de potência e energia influem grandemente nos resultados que se pretende desses aparelhos, bem como na profundidade de penetraçäo do feixe laser


Asunto(s)
Rayos Láser/normas , Planificación de la Radioterapia Asistida por Computador , Dosimetría Termoluminiscente/instrumentación , Rayos Láser/estadística & datos numéricos , Planificación de la Radioterapia Asistida por Computador/instrumentación , Dosimetría Termoluminiscente/estadística & datos numéricos