1.
Journal of Biomedical Engineering ; (6): 87-94, 2023.
Artículo en Chino | WPRIM | ID: wpr-970677

RESUMEN

Extracellular matrix (ECM) has been implicated in tumor progress and chemosensitivity. Ovarian cancer brings a great threat to the health of women with a significant feature of high mortality and poor prognosis. However, the potential significance of matrix stiffness in the pattern of long non-coding RNAs (lncRNAs) expression and ovarian cancer drug sensitivity is still largely unkown. Here, based on RNA-seq data of ovarian cancer cell cultured on substrates with different stiffness, we found that a great amount of lncRNAs were upregulated in stiff group, whereas SNHG8 was significantly downregulated, which was further verified in ovarian cancer cells cultured on polydimethylsiloxane (PDMS) hydrogel. Knockdown of SNHG8 led to an impaired efficiency of homologous repair, and decreased cellular sensitivity to both etoposide and cisplatin. Meanwhile, the results of the GEPIA analysis indicated that the expression of SNHG8 was significantly decreased in ovarian cancer tissues, which was negatively correlated with the overall survival of patients with ovarian cancer. In conclusion, matrix stiffening related lncRNA SNHG8 is closely related to chemosensitivity and prognosis of ovarian cancer, which might be a novel molecular marker for chemotherapy drug instruction and prognosis prediction.


Asunto(s)
Femenino , Humanos , Cisplatino/farmacología , Elasticidad/fisiología , Etopósido , Matriz Extracelular/fisiología , Neoplasias Ováricas/metabolismo , ARN Largo no Codificante/metabolismo
2.
Chinese Journal of Traumatology ; (6): 323-328, 2023.
Artículo en Inglés | WPRIM | ID: wpr-1009504

RESUMEN

PURPOSE@#Previous studies have confirmed that Achilles tendon occurs Achilles thickening after repair surgery of the rupture. Although this mechanism has been elucidated in the laboratory, there are few reports on its impact on clinical function. We designed a retrospective study to investigate the Achilles thickening after Achilles tendon rupture repair and its correlation between the elasticity and postoperative function.@*METHODS@#In this retrospective analysis, patients who underwent surgical treatment for acute Achilles tendon rupture from April 2016 to April 2020 were included. All the patients were regularly followed up at 3 months, 1 year, and 2 years after surgery. American Orthopaedic Foot Ankle Surgeon (AOFAS) scale and Leppilahti score were used to evaluate functional outcomes. Achilles elasticity was measured by ultrasound shear wave of elasticity. Achilles thickening was calculated as maximal transverse and longitudinal diameter in cross-sectional plane of magnetic resonance scan. Sample t-tests was used for different follow-up periods. Correlation between Achilles thickening and other factors were analyzed using Pearson's method. p < 0.05 indicates a statistically significant difference.@*RESULTS@#AOFAS scale and Leppilahti score at 1 year were significantly higher than at 3 months postoperatively (both p < 0.001). These functional scales were also improved at 2-year follow-up significantly (both p < 0.001). The dorsiflexion difference showed gradually recovery in each follow-up period (t = -17.907, p < 0.001). The elasticity of the Achilles appeared to continuously decreases during the postoperative follow-up period in all position sets (p < 0.001). In thickening evaluation, the cross-sectional area of the thickest plane of Achilles was significantly higher at 1 year postoperatively (310.5 ± 25.2) mm2 than that at 3 months postoperatively ((278.0 ± 26.2) mm2, t = -8.219, p < 0.001) and became thinner in 2-year magnetic resonance scan ((256.1 ± 15.1) mm2, t = 16.769, p < 0.001). The correlations between Achilles thickening, elasticity, and functional outcome did not show statistical significance (p > 0.05) in every follow-up period.@*CONCLUSION@#Achilles tendon thickens after surgery in the 1st year, but begins to gradually return to thinning about 2 years after surgery. There was no significant correlation between the increase and decrease of thickening and the patients' clinical function scores, Achilles elasticity, and bilateral ankle dorsiflexion difference.


Asunto(s)
Humanos , Tendón Calcáneo/cirugía , Estudios Retrospectivos , Resultado del Tratamiento , Elasticidad , Traumatismos de los Tendones/cirugía , Rotura/cirugía
3.
Int. j. morphol ; 40(3): 839-850, jun. 2022. ilus, tab
Artículo en Inglés | LILACS | ID: biblio-1385657

RESUMEN

SUMMARY: Several studies have shown beneficial effects of platelet-rich plasma. However, there are very few studies investigating the effectiveness of PRP in the neck region. We aimed to assess the efficacy of PRP injection for neck rejuvenation in females aged 40-55. Fifty-two female consecutive participants had PRP injected and roller applied in three sessions at 3-week intervals. Evaluations were blindly performed by comparing the improvements from the pre- to post-application assessments of anatomical measurements of the neck area based on before and after photography of the participants by two anatomists and three medical aesthetic doctors. The Fitzpatrick Skin Scale, Fitzpatrick Goldman Scale, Wrinkle Assessment Scale (Dedo classification system) and patient satisfaction scale were used for assessment. Additionally, skin stiffness and elasticity, cervicomental angle and jawline angle measurements were performed to analyze anatomical changes in the neck area. The study enrolled 52 volunteers with a mean age of 48.60±5.35 years, mean body weight of 63.21±8.43 kg and mean height of 163.25±4.56 cm. Significant differences were found in the elasticity, jawline angle, cervicomental angle, wrinkling, elasticity G and patient satisfaction scores before and after the treatment. When the results of anatomical parameters and scales are compared, it was revealed that PRP is effective in neck rejuvenation.


RESUMEN: Varios investigaciones han demostrado los efectos beneficiosos del plasma rico en plaquetas. Sin embargo, existen muy pocos estudios que investiguen la efectividad del PRP en la región del cuello. Nuestro objetivo fue evaluar la eficacia de la inyección de PRP para el rejuvenecimiento del cuello en mujeres de 40 a 55 años. A cincuenta y dos mujeres participantes consecutivas se les inyectó PRP y se les aplicó rodillo en tres sesiones a intervalos de 3 semanas. Las evaluaciones se realizaron a ciegas comparando las mejoras de las evaluaciones previas y posteriores a la aplicación de las medidas anatómicas del área del cuello basadas en fotografías de antes y después de los participantes realizadas por dos anatomistas y tres médicos especialistas en cirugía estética. Para la evaluación se utilizaron la escala de piel de Fitzpatrick, la escala de Fitzpatrick Goldman, la escala de evaluación de arrugas (sistema de clasificación Dedo) y la escala de satisfacción del paciente. Además, se realizaron mediciones de rigidez y elasticidad de la piel, ángulo cervicomentoniano y ángulo de la línea de la mandíbula, para analizar los cambios anatómicos en el área del cuello. El estudio inscribió a 52 voluntarios con una edad media de 48,60±5,35 años, un peso corporal medio de 63,21±8,43 kg y una altura media de 163,25±4,56 cm. Se encontraron diferencias significativas en las puntuaciones de elasticidad, ángulo mandibular, ángulo cervicomentoniano, arrugas, elasticidad G y satisfacción del paciente antes y después del tratamiento. Cuando se compararon los resultados de los parámetros anatómicos y las escalas, se reveló que el PRP es eficaz en el rejuvenecimiento del cuello.


Asunto(s)
Humanos , Femenino , Adulto , Persona de Mediana Edad , Rejuvenecimiento , Elasticidad , Plasma Rico en Plaquetas , Cuello , Envejecimiento de la Piel
4.
Journal of Biomedical Engineering ; (6): 1127-1132, 2022.
Artículo en Chino | WPRIM | ID: wpr-970650

RESUMEN

The radial artery pulse wave contains a wealth of physiological and pathological information about the human body, and non-invasive studies of the radial artery pulse wave can assess arterial vascular elasticity in different age groups.The piezoelectric pulse wave transducers were used to non-invasively acquire radial artery pulse waves at different contact pressures in young and middle-aged and elderly populations. The radial artery waveforms were decomposed using a triangular blood flow model fitting method to obtain forward and reflected waves and calculate reflection parameters. Finally a correlation analysis and regression analysis of the contact pressure Psensor with the reflection parameters was carried out. The results showed that the reflection parameters RM, RI and Rd had a strong negative correlation with Psensor in both types of subjects, and the correlation coefficients and slopes of the regression curves were significantly different between the two types of subjects (P<0.05). Based on the results of this study, excessive contact pressure on the transducer should be avoided when detecting radial artery reflection waves in clinical practice. The results also show that the magnitude of the slope of the regression curve between the reflection parameters and the transducer contact pressure may be a potentially useful indicator for quantifying the elastic properties of the vessel.


Asunto(s)
Persona de Mediana Edad , Anciano , Humanos , Presión Sanguínea/fisiología , Arterias , Velocidad del Flujo Sanguíneo/fisiología , Elasticidad , Análisis de la Onda del Pulso , Arteria Radial/fisiología
5.
Rev. bras. oftalmol ; 81: e0036, 2022. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1376779

RESUMEN

ABSTRACT The purpose of this study was to highlight the impact of biomechanical corneal response in available in vivo tonometry methods for glaucoma management. Systematic review of non-contact air-puff tonometers that analyzes the corneal deformation response, with special focus on the investigation of the correlation of derived parameters with intraocular pressure measurements. The two actual and commercially available in vivo corneal tonometers provide promising information about biomechanical characteristics of the cornea and its relation to glaucoma, allowing the development of new protocols to evaluate, diagnose, and manage this disease.


RESUMO O objetivo deste estudo é destacar o impacto da resposta biomecânica corneana em métodos de tonometria in vivo disponíveis para o manejo do glaucoma. Trata-se de revisão sistemática de tonômetros de ar que analisa a resposta à deformação corneana, com foco especial na investigação da correlação dos parâmetros derivados com as medições da pressão intraocular. Os dois tonômetros mais recentes e comercialmente disponíveis fornecem informações promissoras sobre as características biomecânicas da córnea e sua relação com o glaucoma, permitindo o desenvolvimento de novos protocolos para avaliar, diagnosticar e controlar a doença.


Asunto(s)
Humanos , Tonometría Ocular/instrumentación , Tonometría Ocular/métodos , Fenómenos Biomecánicos , Córnea/anatomía & histología , Córnea/fisiología , Presión Intraocular/fisiología , Glaucoma/fisiopatología , Hipertensión Ocular/fisiopatología , Técnicas de Diagnóstico Oftalmológico/instrumentación , Elasticidad/fisiología , Modelos Teóricos
6.
China Journal of Chinese Materia Medica ; (24): 2244-2250, 2022.
Artículo en Chino | WPRIM | ID: wpr-928165

RESUMEN

The present study explored the correlation of coronary heart disease(CHD) with blood stasis syndrome in postmenopausal women with artery elasticity and endothelial function indexes and evaluated the diagnostic efficacy of the prediction model via logistic regression and receiver operating characteristic(ROC) curve model. A retrospective comparison was made between 366 postmenopausal CHD patients from August 1, 2020, to September 30, 2021, in the Department of Cardiology of Integrated Traditional Chinese and Western Medicine of China-Japan Friendship Hospital, who were divided into the blood stasis syndrome group(n=196) and the non-blood stasis syndrome group(n=170). General clinical characteristics of the two groups were compared. Multivariate logistic regression analysis was used to probe the correlation of CHD with blood stasis syndrome in postmenopausal women with brachial-ankle pulse wave velocity(baPWV), ankle-brachial index(ABI), and flow-mediated dilatation(FMD), and the ROC curve was drawn to evaluate the diagnostic efficiency of the prediction model. Multivariate logistic regression analysis showed that the correlation coefficients of CHD with blood stasis syndrome in postmenopausal women with baPWV, ABI, and FMD were 1.123, 0.109, and 0.719, respectively(P=0.004, P=0.005, P<0.001),and the regression equation for predicting probability P was P=1/[1+e~(-(3.131+0.116×baPWV-2.217×ABI-0.330×FMD))]. ROC curve analysis suggested that in the context of baPWV≥19.19 m·s~(-1) or ABI≤1.22 or FMD≤9.7%, it was of great significance to predict the diagnosis of CHD with blood stasis syndrome in postmenopausal women. The AUC of baPWV, ABI, FMD, and prediction probability P was 0.763, 0.607, 0.705, and 0.836, respectively. The AUC of prediction probability P was higher than that of each index alone(P<0.001), and the sensitivity and specificity were 0.888 and 0.647, respectively. The results demonstrate that baPWV, ABI, and FMD are independently correlated with CHD with blood stasis syndrome in postmenopausal women, and show certain independent predictive abilities(P<0.05). The combined evaluation of the three possesses the best diagnostic efficiency.


Asunto(s)
Femenino , Humanos , Índice Tobillo Braquial , Arteria Braquial , Enfermedad Coronaria/diagnóstico , Elasticidad , Modelos Logísticos , Posmenopausia , Análisis de la Onda del Pulso , Curva ROC , Estudios Retrospectivos
7.
Chinese Journal of Contemporary Pediatrics ; (12): 566-571, 2022.
Artículo en Chino | WPRIM | ID: wpr-928644

RESUMEN

OBJECTIVES@#To study the application of three-dimensional speckle-tracking imaging in evaluating left ventricular systolic function and its correlation with peripheral arterial elasticity in children with simple obesity.@*METHODS@#Random sampling combined with convenience sampling was used to obtain research samples, and then the samples were divided into an obesity group (23 cases), an overweight group (21 cases), and a normal group (24 cases). Three-dimensional speckle-tracking imaging was used to measure the global longitudinal strain (GLS), global radial strain (GRS), and global circumferential strain (GCS) of the left ventricle. An automatic arteriosclerosis tester was used to measure ankle-brachial index (ABI) and brachial-ankle pulse wave velocity (baPWV). These parameters were compared among the three groups. The correlation of three-dimensional speckle-tracking parameters with ABI and baPWV was evaluated.@*RESULTS@#There were no significant differences in GLS, GRS, and GCS between the obesity and normal groups (P>0.05). The overweight group had a significantly higher GLS than the normal group [(-24±7) vs (-19±12), P<0.05]. The obesity and overweight groups had a significantly lower ABI than the normal group [(1.00±0.09)/(1.09±0.13) vs (2.25±0.13), P<0.05). The obesity group had a significantly higher baPWV than the normal group [(978±109) vs (905±22), P<0.05]. In the children with obesity, GLS was positively correlated with baPWV (r=0.516, P<0.05) , but not correlated with ABI (P>0.05), and GCS and GRS had no significant correlation with ABI or baPWV (P>0.05).@*CONCLUSIONS@#There are varying degrees of changes in left ventricular systolic function and peripheral arterial elasticity in children with simple obesity, and there is a certain correlation between them.


Asunto(s)
Niño , Humanos , Índice Tobillo Braquial , Ecocardiografía Tridimensional/métodos , Elasticidad , Obesidad , Sobrepeso , Estudios Prospectivos , Análisis de la Onda del Pulso
8.
Braz. dent. j ; 32(4): 55-61, July-Aug. 2021. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1345512

RESUMEN

Abstract The purpose of this in vitro study was to evaluate the force decrease of different elastomeric chains after different times: initial, 10 minutes, 1 day, 28 days and after mechanical brushing. Twenty orthodontic elastomeric chains segments were utilized for each commercial brand. Initially, the elastomeric chain of 15mm long were immediate stretched up to 20 mm in an Instron and the force was measured in gf. After all specimens were placed stretched on rectangular acrylic jigs with distance of 20 mm, immersed in deionized water at 37oC for 10 minutes and the force (gf) was measured again. Five test measurements of remaining force were made at the following time intervals: initial, 10 minutes, 1 day, 28 days and mechanical brushing. After 28 days, the acrylic plates with the specimens were adapted in the mechanical brushing machines (MSCT 3) and the elastomeric chains were submitted to mechanical brushing and the force (gf) measure again. The force (gf) was submitted to mixed-model ANOVA and Sidak post-hoc test (α=0.05). A statistically significant reduction in the force was found for all orthodontic elastomeric chain types after 1 day, 28 days and mechanical brushing (p<0.05). Morelli and 3M Unitek elastomeric chains showed significantly higher force than Abzil and GAC (p<0.05) after 1 day, 28 days and mechanical brushing. In conclusion, the force delivered by all elastomeric chains decayed rapidly over time. Morelli and 3M Unitek elastomeric chains consistently had a significantly greater force after mechanic brushing, while GAC the lowest.


Resumo O objetivo deste estudo in vitro foi avaliar a redução da força de diferentes cadeias elastoméricas após diferentes tempos: inicial, 10 minutos, 1 dia, 28 dias e após escovação mecânica. Vinte segmentos de cadeias elastoméricas ortodônticas foram utilizadas para cada marca comercial. Inicialmente, a cadeia elastomérica de 15 mm de comprimento foi esticada imediatamente até 20 mm na Instron e a força foi medida em (gf). Após, todas as amostras foram adaptadas esticadas em placas retangulares de acrílico na distância de 20 mm, imersas em água deionizada a 37o C por 10 minutos e a força (gf) foi medida novamente. Cinco medidas de força foram feitas nos seguintes intervalos de tempo: inicial, 10 minutos, 1 dia, 28 dias e após a escovação mecânica. Após 28 dias, as placas de acrílico com as amostras foram adaptadas na máquina de escovação (MSCT 3) e as cadeias elastoméricas foram submetidas a escovação mecânica e a medida de força (gf) novamente. Os dados da força (gf) foram submetidos a ANOVA modelo misto e teste post-hoc de Sidak (α = 0,05). Uma redução estatisticamente significativa na força foi encontrada para todos os tipos de cadeia elastomérica ortodôntica após 1 dia, 28 dias e escovação mecânica (p<0,05). As cadeias elastoméricas Morelli e 3M Unitek apresentaram força significativamente superior em relação a Abzil e GAC (p<0,05) após 1 dia, 28 dias e escovação mecânica. Em conclusão, a força distribuída por todas as cadeias elastoméricas decaiu rapidamente com o tempo. As cadeias elastoméricas Morelli e 3M Unitek consistentemente tiveram uma força significativamente maior após a escovação mecânica, enquanto GAC a mais baixa.


Asunto(s)
Aparatos Ortodóncicos , Elastómeros , Estrés Mecánico , Cepillado Dental , Ensayo de Materiales , Elasticidad
9.
Rev. colomb. gastroenterol ; 36(1): 58-64, ene.-mar. 2021. tab, graf
Artículo en Español | LILACS | ID: biblio-1251522

RESUMEN

Resumen Introducción: la elastografía en tiempo real, 2D-SWE (Supersonic), es una prueba no invasiva que se utiliza para determinar la elasticidad del hígado y, de esa forma, calcular el grado de fibrosis hepática. En Colombia, la prueba se introdujo en 2016 y no existen hasta el momento estudios del comportamiento de la prueba en todos los pacientes hepáticos, solo se han publicado en pacientes sanos y cirróticos. Objetivo: analizar la experiencia de la aplicación de la elastografía en tiempo real, en sujetos atendidos en el centro de enfermedades hepáticas y digestivas de Bogotá, Colombia. Materiales y métodos: estudio descriptivo retrospectivo de una cohorte de sujetos atendidos entre marzo de 2016 y julio de 2017. Se realizó una historia clínica completa y una prueba de elastografía en tiempo real (Supersonic). Resultados: se incluyeron 654 sujetos, con una mediana de edad de 55 años (rango intercuartílico [RIC]: 45-64). La mediana de valores de fibrosis expresada en kilopascales (kPs) fue de 8,3, con un promedio de 5 mediciones. Se observó una diferencia significativa en el grado de fibrosis entre los grupos de edad y en relación con el diagnóstico final, donde se evidenció una mayor fibrosis en el grupo de enfermedades colestásicas (autoinmune, colangitis biliar primaria [CBP] y superposición autoinmune-CBP). La tasa global de fracaso fue menor al 1%. Conclusiones: es la primera descripción del comportamiento de la prueba a nivel nacional. Los valores de rigidez hepática observados en los diferentes estadios demuestran la utilidad de la prueba para la determinación de la fibrosis hepática en pacientes con diferentes patologías.


Abstract Introduction: Real-time two-dimensional shear wave elastography (2D-SWE) (Supersonic Imagine SA), is a non-invasive test used to determine liver elasticity and calculate the degree of liver fibrosis. In Colombia, this test was introduced in 2016 and, to date, no study has tested its behavior in all liver patients, only in healthy and cirrhotic patients. Objective: To analyze the experience of real-time elastography implementation in subjects treated at the Centro de Enfermedades Hepáticas y Digestivas in Bogotá, Colombia. Materials and methods: This is a retrospective descriptive study of a cohort of subjects treated between March 2016 and July 2017. A complete medical report and a real-time elastography (Supersonic) test were performed. Results: 654 subjects were included, with a median age of 55 years (interquartile range [IQR]: 45-64). The median fibrosis values expressed in kilopascals (kPs) were 8.3, with an average of 5 measurements. There was a significant difference in the degree of fibrosis between the age groups and in relation to the final diagnosis, where there was a greater fibrosis in the cholestatic disease group (autoimmune, primary biliary cholangitis [PBC], and overlap). The overall failure rate was less than 1%. Conclusions: This is the first description of this test behavior in the country. Hepatic stiffness values observed in the different stages demonstrate the usefulness of the test to establish the degree of liver fibrosis in patients with multiple diseases.


Asunto(s)
Humanos , Masculino , Femenino , Adolescente , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Fibrosis , Diagnóstico por Imagen de Elasticidad , Hígado , Registros Médicos , Elasticidad , Informe de Investigación , Métodos
10.
Rev. bras. ciênc. mov ; 29(1): [1-15], jan.-mar. 2021. tab, ilus
Artículo en Portugués | LILACS | ID: biblio-1348199

RESUMEN

: A cervicobraquialgia (CB) é caracterizada por uma dor com origem em diferentes níveis estruturais da coluna cervical baixa (C3- C7), com irradiação bilateral ou unilateral para o membro superior. Considerando as causas e consequências advindas da CB, novas modalidades de tratamento têm sido propostas na tentativa de promover intervenções efetivas. Entre os procedimentos fisioterapêuticos encontram-se as técnicas de terapia manual como liberação miofascial, quiropraxia, mobilização articular, estabilização segmentar e a mobilização neural (MN) que procura restabelecer a função do tecido neural, sua condução elétrica, elasticidade, movimento e fluxo axoplasmático. Sendo assim, o objetivo do estudo foi avaliar sistematicamente as evidências sobre o efeito da MN no tratamento da dor em indivíduos com CB. A busca bibliográfica foi realizada no período entre Novembro de 2018 a Junho de 2019, sem limite de ano de publicação, nas bases de dados: PEDro, PubMed, Biblioteca Virtual em Saúde (Lilacs, Scielo e Medline) e Cochrane Library. A análise foi restrita aos ensaios clínicos randomizados. Para a análise etodológica dos artigos aptos a inclusão, foi utilizada a escala PEDro. Foi encontrado um total de 38 artigos. Após remoção de duplicatas, 14 artigos foram elegidos por resumo, 8 artigos foram recuperados para leitura completa e analisados quanto a sua adequação, dos quais 3 foram excluídos por não cumprirem os critérios de elegibilidade, ao fim 5 artigos foram incluídos na revisão. Houve redução significativa da dor, em pacientes tratados com MN. Considerando os resultados obtidos nesta revisão, foi possível concluir que a MN demonstra ser eficaz na redução da dor presente na CB. Embora os estudos mostrem que os resultados da MN como tratamento da CB são significativamente inferiores ao efeito do Ibuprofeno, deve-se ter em consideração as consequências a longo prazo para a saúde sobre a utilização de anti- inflamatórios orais.(AU)


Cervicobrachialgia (CB) is characterized by pain originating from different structural levels of the lower cervical spine (C3-C7), w ith bilateral or unilateral irradiation to the upper limb. Considering the causes and consequences of CB, new treatment modalities have been proposed in an attempt to promote effective interventions. Among the physical therapy procedures are manual therapy techniques such as myofascial release, chiropractic, joint mobilization, segmental stabilization and neural mobilization (NM) that seeks to restore the function of neural tissue, its electrical conduction, elasticity, movement and ax oplasmic flow . Thus, the objective of the study w as to evaluate systematically evaluate the evidence on the effect of NM on pain management in individuals w ith CB. The bibliographic search w as performed from November 2018 to June 2019, w ithout limit of year of publication, in the databases: PEDro, PubMed, Virtual Health Library (Lilacs, Scielo and Medline) and Cochrane Library. The analysis w as restricted to randomized controlled trials. For the methodological analysis of the articles eligible for inc lusion, the PEDro scale w as used. A total of 38 articles w ere found. After removal of duplicates, 14 articles w ere elected by abstract, 8 articles w ere retrieved for full reading and analyzed for suitability, of w hich 3 w ere excluded for not meeting eligibility c riteria, at the end 5 articles w ere included in the review . There was a significant pain reduction in patients treated w ith NM. Considering the results obtained in this review , it w as concluded that NM demonstrates to be effective in reducing pain present in CB. Although studies show that the results of NM as a treatment for CB are significantly low er than the effect of ibuprofen, consideration should be given to the long-term health consequences about the utilization of oral anti-inflammatory drugs.(AU)


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Dolor , Manejo del Dolor , Conducción Nerviosa , Neuralgia , Educación y Entrenamiento Físico , Quiropráctica , Modalidades de Fisioterapia , Manipulación Espinal , Conducción de Calor , Manipulaciones Musculoesqueléticas , Extremidad Superior , Elasticidad , Articulaciones
11.
Dental press j. orthod. (Impr.) ; 26(2): e211945, 2021. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1249705

RESUMEN

ABSTRACT Objective: This paper aims to verify the thermodynamic, mechanical and chemical properties of CuNiTi 35ºC commercial wires. Methods: Forty pre-contoured copper-nickel-titanium thermodynamic 0.017 x 0.025-in archwires with an Af temperature of 35°C were used. Eight wires from five different manufacturers (American Orthodontics® [G1], Eurodonto® [G2], Morelli® [G3], Ormco® [G4] and Orthometric® [G5]) underwent cross-sectional dimension measurements, tensile tests, SEM-EDS and differential scanning calorimetry (DSC) tests. Parametric tests (One-way ANOVA and Tukey post-test) were used, with a significance level of 5%, and Pearson's correlation coefficient test was performed between the Af and chemical elements of the wires. All sample tests and statistical analyses were double-blinded. Results: All wires presented standard dimensions (0.017 x 0.025-in) and superelastic behavior, with mean plateau forces of: G1 = 36.49N; G2 = 27.34N; G3 = 19.24 N; G4 = 37.54 N; and G5 = 17.87N. The Af means were: G1 = 29.40°C, G2 = 29.13°C and G3 = 31.43°C, with p>0.05 relative to each other. G4 (32.77°C) and G5 (35.17°C) presented statistically significant differences between each other and among the other groups. All samples presented Ni, Ti, Cu and Al in different concentrations. Conclusions: The chemical concentration of the elements that compose the alloy significantly influenced the thermodynamic and mechanical properties.


RESUMO Objetivo: O presente artigo teve como objetivo verificar as propriedades termodinâmicas, mecânicas e químicas de fios CuNiTi 35°C comerciais. Métodos: Foram utilizados 40 arcos termodinâmicos pré-contornados de cobre-níquel-titânio de 0,017" x 0,025" e temperatura Af de 35°C. Oito fios de cinco fabricantes diferentes (American Orthodontics® [G1], Eurodonto® [G2], Morelli® [G3], Ormco® [G4] e Orthometric® [G5]) foram submetidos a medições de suas secções transversais, testes de tração, MEV-EDS e calorimetria diferencial (DSC). Foram utilizados testes paramétricos (One-way ANOVA e pós-teste de Tukey), com nível de significância de 5%, e foi realizado o teste do coeficiente de correlação de Pearson entre a temperatura Af e os elementos químicos dos fios. Todos os testes das amostras e análises estatísticas foram duplo-cegos. Resultados: Todos os fios apresentavam dimensões padronizadas (0,017" x 0,025") e comportamento superelástico, com forças médias de platô de G1 = 36,49 N; G2 = 27,34 N; G3 = 19,24 N; G4 = 37,54 N; e G5 = 17,87 N. As médias de Af foram: G1 = 29,40°C, G2 = 29,13°C e G3 = 31,43°C, com p> 0,05 entre si. G4 (32,77°C) e G5 (35,17°C) apresentaram diferenças estatisticamente significativas entre si e entre os demais grupos. Todas as amostras apresentaram Ni, Ti, Cu e Al em diferentes concentrações. Conclusões: A concentração química dos elementos que compõem a liga influenciou significativamente as propriedades termodinâmicas e mecânicas.


Asunto(s)
Alambres para Ortodoncia , Aleaciones Dentales , Estrés Mecánico , Titanio , Ensayo de Materiales , Estudios Transversales , Elasticidad
12.
Rev. cuba. med. mil ; 49(3): e511, jul.-set. 2020. fig
Artículo en Español | LILACS, CUMED | ID: biblio-1144485

RESUMEN

Introducción: Para definir una adecuada estrategia terapéutica en el cáncer de recto es preciso una correcta estadificación. El ultrasonido endoscópico es un método de estadiaje preciso que define la profundidad del tumor y el estado nodal. En los tumores tratados con radioterapia disminuye su rentabilidad por la fibrosis que se origina en la pared rectal; indistinguible de los elementos de malignidad. La elastografía brinda la posibilidad de resolver esta limitación. Objetivo: Ofrecer una actualización sobre la elastografía por ultrasonido endoscópico en el diagnóstico del paciente con tumor rectal. Desarrollo: La elastografía se basa en las alteraciones que en la elasticidad del tejido inducen la fibrosis y el cáncer. Determina si un tejido es maligno o benigno mediante el análisis de su dureza. Se obtienen imágenes que se expresan en un mapa de colores superpuestas a la imagen convencional del ultrasonido endoscópico. Muchas investigaciones demuestran su elevada sensibilidad y especificidad en tumores de páncreas y ganglios linfáticos, algunas en tumores de esófago, sin embargo muy pocas en el cáncer rectal. Conclusiones: La elastografía ha mejorado el diagnóstico y seguimiento oncológico del paciente con tumor rectal(AU)


Introduction: To define an adequate therapeutic strategy in rectal cancer, a correct staging is necessary. For this, advanced diagnostic means have been developed to evaluate the rectal wall. Endoscopic Ultrasound a fundamental technique; combines endoscopic image with ultrasound; in tumors treated with radiotherapy, its profitability decreases due to fibrosis that originates in the rectal wall; indistinguishable from the elements of malignancy. Elastography offers the possibility of resolving this limitation. Objective: To offer an update on elastography by endoscopic ultrasound in the diagnosis of the patient with rectal tumor. Development: Elastography is based on the alterations that fibrosis and cancer induce in the elasticity of the tissue. Determine if a tissue is malignant or benign by analyzing its hardness. Images are obtained that are expressed on a color map superimposed on the conventional endoscopic ultrasound image. Many investigations demonstrate its high sensitivity and specificity in tumors of the pancreas and lymph nodes, some in esophageal tumors, however very few in rectal cancer. Conclusions: Elastography has improved the diagnosis and oncological follow-up of the patient with rectal tumor(AU)


Asunto(s)
Humanos , Masculino , Femenino , Neoplasias del Recto/diagnóstico por imagen , Elasticidad/efectos de la radiación , Diagnóstico por Imagen de Elasticidad , Ganglios Linfáticos
13.
Chinese Journal of Medical Instrumentation ; (6): 384-389, 2020.
Artículo en Chino | WPRIM | ID: wpr-942746

RESUMEN

To satisfy the daily demand of skin condition maintenance, make non-invasive real-time detection, and get proper quantitative evaluation of skin viscoelasticity parameters at the same time, a portable non-invasive detection system to acquire real-time skin tissue viscoelasticity is developed. The system relies mainly on a single-degree-of-freedom forced vibration model, with spring-damp-mass, and on dynamic micro indentation method. The experiment is conducted on two kinds of springs, and on pigskin tissues as well, the system's suitability, accuracy and stability are confirmed. The skin viscoelasticity detection in vivo is also carried out on 20 subjects with different ages, the differences of skin viscoelasticity in various parts of the body are investigated, and the correlations between age and skin viscoelasticity are clarified.


Asunto(s)
Humanos , Elasticidad , Piel , Fenómenos Fisiológicos de la Piel , Tiempo , Viscosidad
15.
Korean Journal of Radiology ; : 384-385, 2020.
Artículo en Inglés | WPRIM | ID: wpr-810974

RESUMEN

No abstract available.


Asunto(s)
Diagnóstico por Imagen de Elasticidad , Elasticidad , Tendones , Ultrasonografía
16.
Rev. bras. cir. cardiovasc ; 34(4): 451-457, July-Aug. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1020508

RESUMEN

Abstract Objective: To evaluate the aortic wall elasticity using the maximal rate of systolic distension (MRSD) and maximal rate of diastolic recoil (MRDR) and their correlation with the aortic size index (ASI). Methods: Forty-eight patients with thoracic aortic aneurysm were enrolled in this study. A standard magnetic resonance imaging (MRI) protocol was used to calculate MRSD and MRDR. Both MRSD and MRDR were expressed as percentile of maximal area/10-3 sec. ASI (maximal aortic diameter/body surface area) was calculated. A correlation between MRSD, MRDR, ASI, and the patient's age was performed using regression plot. Results: A significant correlation between MRSD (t=-4,36; r2=0.29; P≤0.0001), MRDR (t=3.92; r2=0.25; P=0.0003), and ASI (25±4.33 mm/m2; range 15,48-35,14 mm/m2) is observed. As ASI increases, aortic MRSD and MRDR decrease. Such inverse correlation between MRSD, MRDR, and ASI indicates increased stiffness of the ascending aorta. A significant correlation between the patient's age and the decrease in MRSD and MRDR is observed. Conclusion: MRSD and MRDR are significantly correlated with ASI and the patient's age. They seem to describe properly the increasing stiffness of aortas. These two new indexes provide a promising, accessible, and reproducible approach to evaluate the biomechanical property of the aorta.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Aorta/fisiopatología , Imagen por Resonancia Magnética , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Disección Aórtica/diagnóstico por imagen , Sístole/fisiología , Diástole/fisiología , Dilatación Patológica , Elasticidad
17.
Santiago de Chile; Chile. Ministerio de Salud; 2019. 6 p.
No convencional en Español | LILACS, BRISA, PIE, MINSALCHILE | ID: biblio-1516392

RESUMEN

ANTECEDENTES Y OBJETIVO Considerando que el consumo excesivo de alcohol provoca daños a la salud y potenciales daños al entorno de los bebedores, los gobiernos han aplicado impuestos y políticas de precios de manera de persuadir su consumo. Se ha demostrado que el precio es un factor principal que influencia la ingesta y los daños asociados. En consecuencia, la Subsecretaría de Salud Pública solicita este reporte con el objetivo de entregar información sobre los efectos de los impuestos al alcohol en el consumo. METODOLOGÍA Se realizó una búsqueda de evidencia científica en dos bases de datos. Se incluyeron revisiones sistemáticas de estudios primarios que evaluaran el efecto de los impuestos al alcohol, publicadas en los últimos 10 años sin restringir por idioma. Se excluyeron revisiones sistemáticas cuyos estudios no fueran realizados en humanos. RESULTADOS Se utilizan 2 revisiones sistemáticas -El consumo de alcohol se reduce con un aumento en su precio: Los metaanálisis incluidos muestran que el aumento de 1% en el precio del alcohol, reducen la demanda en 0,5% en promedio. La magnitud de la elasticidad difiere entre grupos, pero el signo es siempre negativo. -La respuesta al aumento del precio depende del tipo de bebida: Los estudios muestran que la cerveza tiene la demanda más inelástica, en comparación con el vino y los destilados. -Los estudios indican que el aumento de precios es levemente menos efectivo en reducir el consumo en la población joven; y los hombres responden un poco menos al aumento de precios que las mujeres. -La respuesta al aumento del precio depende del lugar en que se compre: La elasticidad precio por el alcohol también varía dependiendo del lugar en que se compre, existiendo una mayor sensibilidad al precio la compra en botillerías o licorerías, en comparación con la compra en establecimientos como bares o restaurantes -No hay consenso en la política de precios o de impuestos más adecuada: implementar políticas impositivas y de precios está bastante aceptado en el mundo y el 90% de los países lo aplican. Pero hay alto desacuerdo en cuál es la política más adecuada, dependiendo de los contextos.


Asunto(s)
Bebidas Alcohólicas , Chile , Elasticidad , Política de Salud
18.
urol. colomb. (Bogotá. En línea) ; 28(3): 204-208, 2019. ilus
Artículo en Español | LILACS, COLNAL | ID: biblio-1402385

RESUMEN

La estrechez de la uretra es una patología con una prevalencia del 0,6% de la población El estándar de oro establecido para su manejo es la uretroplastia con tasas de éxito variables de hasta el 90% al 95%. El stent uretral surgió en 1988 fabricado con malla de acero inoxidable. Los resultados obtenidos demostraron las complicaciones severas de su implantación. En el 2008 se introdujo el stent Allium producido en Israel con propiedades diferentes como elasticidad y flexibilidad. Puede utilizarse en diferentes entidades como estrechez de uretra bulbar, hiperplasia de próstata y la estenosis de la unión uretrovesical. Recientemente este Stent se está comercializando en Colombia, por lo cual consideramos importante revisar la literatura mundial, las complicaciones e indicaciones reales y así intentar evitar el uso inapropiado de esos dispositivos. Realizamos una Revisión de la literatura en PubMed y ClinicalKey incluyendo los términos, "Stent", "Allium" y "Urethral", incluyendo articulos en inglés y en español. Se encontraron 4 artículos retrospectivos en poblaciones heterogéneas con tasas de éxito inferiores a la cirugía reconstructiva. No se encontraron estudios comparativos. Las indicaciones actuales para colocar un stent uretral podrían ser pacientes en quienes no se puede realizar uretroplastia, o en quienes el manejo endoscópico de la uretra posterior no haya sido efectivo. También pu


Urethral stricture disease is a pathology with a prevalence of 0.6% of the population The gold standard established for its management is urethroplasty with variable success rates of up to 90% to 95%. The urethral stent arose in 1988 manufactured with stainless steel mesh. The results obtained showed the severe complications of its implantation. In 2008, the Allium stent was produced in Israel with different properties such as elasticity and flexibility. It can be used in different entities such as bulbar urethra strictures, prostatic hyperplasia and stenosis of the urethrovesical junction. Recently this Stent is being marketed in Colombia, which is why we consider important to review the literature, complications and real indications and thus try to avoid the inappropriate use of these devices. We conducted a literature review in PubMed and ClinicalKey including the terms "Stent", "Allium" and "Urethral", including articles in English and Spanish. We found 4 retrospective articles in heterogeneous populations with success rates lower than reconstructive surgery. No comparative studies were found. Current indications to place a stent urethral could be patients in whom urethroplasty cannot be performed, or in patients in which endoscopic management of the posterior urethra has not been effective. It can also be an alternative for patients with permanent bladder catheter due to prostatic hyperplasia not suitable for surgery


Asunto(s)
Humanos , Masculino , Estrechez Uretral , Catéteres , Próstata , Hiperplasia Prostática , Vejiga Urinaria , Constricción Patológica , Procedimientos de Cirugía Plástica , Elasticidad
19.
Acta Academiae Medicinae Sinicae ; (6): 383-387, 2019.
Artículo en Chino | WPRIM | ID: wpr-776022

RESUMEN

Objective To compare the values of elasticity imaging(EI)and Virtual Touch tissue imaging and quantification(VTIQ)in diagnosing thyroid nodules and explore the factors influencing the accuracy of these two techniques.Methods Totally 62 patients who were planned to receive surgery for thyroid nodules underwent conventional ultrasound,EI,and VTIQ examinations.EI patterns were scored according to the degree and distribution of strain,the strain of nodule and surrounding normal reference tissue were measured,and then strain index was calculated.Shear wave velocity in nodules were obtained under VTIQ mode.Results The nodules were malignant in 40 patients and benign in 22 patients.When the strain score of 3 was regarded as malignant,the diagnostic sensitivity,specificity,and accuracy of EI in detecting thyroid nodules were 90.00%,31.82%,and 69.32%,respectively.Receiver operating characteristic curve results showed that the area under curves of EI-SI and VTIQ methods for diagnosing thyroid nodules was 77.8%(95%:0.64-0.91)(=0.000)and 74.3%(95%:0.62-0.87)(=0.002),respectively.Thyroid nodules' characteristics location(=0.04)and size(=0.02)were correlated with the diagnostic accuracy of EI.The accuracy of SI and VTIQ were not affected by thyroid nodules' characteristics(>0.05).Conclusions The diagnostic accuracy of EI for thyroid nodules is related to nodules' characteristics.EI combined with semi-quantitative SI and quantitative VTIQ can effectively improve the diagnostic capability for thyroid nodules.


Asunto(s)
Humanos , Diagnóstico Diferencial , Elasticidad , Diagnóstico por Imagen de Elasticidad , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Nódulo Tiroideo , Diagnóstico por Imagen , Ultrasonografía , Realidad Virtual
20.
Journal of Biomedical Engineering ; (6): 613-618, 2019.
Artículo en Chino | WPRIM | ID: wpr-774164

RESUMEN

Study of the mechanical properties of in vivo corneal materials is an important basis for further study of corneal physiological and pathological phenomena by means of finite element method. In this paper, the elastic coefficient ( ) and viscous coefficient ( ) of normal cornea and keratoconus under pulse pressure are calculated by using standard linear solid model with the data provided by corneal visualization scheimpflug technology. The results showed that there was a significant difference of and between normal cornea and keratoconus cornea ( < 0.05). Receiver operating characteristic curve analysis showed that the area under curve (AUC) for , and their combined indicators were 0.776, 0.895 and 0.948, respectively, which indicated that keratoconus could be predicted by and . The results of this study may provide a reference for the early diagnosis of keratoconus and avoid the occurrence of keratoconus after operation, so it has a certain clinical value.


Asunto(s)
Humanos , Área Bajo la Curva , Córnea , Fisiología , Elasticidad , Queratocono , Patología , Curva ROC , Viscosidad