1.
Rev. bras. ginecol. obstet ; 42(4): 228-232, Apr. 2020. graf
Artículo en Inglés | LILACS | ID: biblio-1137818

RESUMEN

Abstract The present report describes a case of complete atrioventricular block (CAVB) diagnosed at 25 weeks of gestation in a pregnant woman with Sjögren's syndrome and positive anti-Ro/SSA antibodies. Fluorinated steroids (dexamethasone and betamethasone) and terbuline were used to increase the fetal heart rate, but the fetal heart block was not reversible, and the administration of drugs was discontinued due to maternal collateral effects. Follow-up fetal echocardiograms were performed, and the fetus evolved with pericardial effusion, presence of fibroelastosis in the right ventricle, and ventricular dysfunction. Interruption of pregnancy by cesarean section was indicated at 34 weeks of gestation, and a cardiac pacemaker was implanted in the male newborn immediately after birth. Therapy for fetuses with CAVB is controversial mainly regarding the use or not of corticosteroids; however, monitoring of the atrioventricular interval by fetal echocardiography should be performed in fetuses from pregnant women with positive autoantibodies anti-Ro/SSA and/or anti-La/SSB to prevent the progression to CAVB.


Resumo Este relato descreve um caso de bloqueio atrioventricular completo (BAVC) diagnosticado com 25 semanas de gestação em uma mulher com síndrome de Sjögren e anticorpos anti-Ro/SSA positivos. Esteroides fluoretados (dexametasona e betametasona) e terbulina foram utilizados para aumentar a frequência cardíaca fetal, mas o bloqueio cardíaco fetal não foi reversível, e a administração dos medicamentos foi interrompida devido a efeitos colaterais maternos. Ecocardiogramas fetais de acompanhamento foram realizados, e o feto evoluiu com derrame pericárdico, presença de fibroelastose no ventrículo direito, e disfunção ventricular. A interrupção da gravidez por cesariana foi indicada com 34 semanas, e um marca-passo cardíaco foi implantado no recém-nascido do sexo masculino imediatamente após o nascimento. A terapia para fetos com BAVC é controversa, principalmente no que diz respeito ao uso ou não de corticosteroides; no entanto, o monitoramento do intervalo atrioventricular pela ecocardiografia fetal deve ser feito em fetos de mulheres grávidas com autoanticorpos positivos anti-Ro/SSA e/ou anti-La/SSB para impedir a progressão para o BAVC.


Asunto(s)
Humanos , Femenino , Embarazo , Adulto , Complicaciones Cardiovasculares del Embarazo , Síndrome de Sjögren/complicaciones , Bloqueo Cardíaco/congénito , Atención Prenatal , Autoanticuerpos/sangre , Frecuencia Cardíaca Fetal/fisiología , Ultrasonografía Prenatal
2.
Rev. bras. ginecol. obstet ; 41(9): 531-538, Sept. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1042338

RESUMEN

Abstract Objective To determine the effect of treadmill walking on maternal heart rate (MHR) and cardiotocographic parameters (basal fetal heart rate [FHR], active fetal movements [AFM], number of accelerations and decelerations, and short-term variation [STV] and long-term variation [LTV] of fetal heart rate) in pregnant women at 36 weeks. Methods A nonrandomized, open clinical trial involving 88 healthy pregnant women submitted to moderate intensity walking and computed cardiotocography in 3 20- minute periods (resting, treadmill walking, and postexercise recovery). Results The mean FHR decreased during walking (resting: 137 bpm; treadmill: 98 bpm; recovery: 140 bpm; p<0.001), with bradycardia occurring in 56% of the fetuses in the first 10minutes of exercise, and in 47% after 20minutes. Bradycardia was not detected in the other phases. The mean STV and HV were 7.9, 17.0, and 8.0 milliseconds (p<0.001) and 7.6, 10.8 and 7.6 bpm (p=0.002) in the resting, walking and recovery phases, respectively. Themean number of fetalmovements in 1 hour was 29.9, 22.2 and 45.5, respectively, in the 3 periods (p<0.001). In overweight/obese women, the mean FHR was lower (p=0.02). Following the logistic regression analysis, two variables remained significantly associated with bradycardia: maternal fitness in the 28th week of pregnancy (protective effect) and maternal weight (increased risk). Conclusion In healthy fetuses, physical exercise proved to be safe, since, although FHR and AFM decreased during treadmill walking, an increase in SVT and LTV was observed.


Resumo Objetivo Determinar o efeito da caminhada em esteira sobre a frequência cardíaca materna (FCM) e parâmetros cardiotocográficos (batimentos cardiofetais basais [BCFs], movimentos ativos fetais [MAFs], número de acelerações e desacelerações e variabilidade de curta [STV] e longa [LTV] duração da frequência cardíaca fetal) em gestantes na 36a semana. Métodos Foi realizado umensaio clínico não randomizado e aberto com 88 gestantes saudáveis submetidas a caminhada de moderada intensidade na esteira e a cardiotocografia computadoriza em 3 momentos de 20 minutos (antes, durante e após a caminhada). Resultados A média dos BCFs diminuiu durante a caminhada, retornando a níveis prévios (antes: 137 bpm; durante: 98 bpm; após: 140 bpm; p<0,001), com bradicardia ocorrendo em 56% dos fetos nos primeiros 10 minutos do exercício, e em 47% após 20 minutos. A bradicardia fetal não foi observada em outrosmomentos (antes ou depois). As médias da STV e da LTV foram 7,9, 17,0 e 8,0milissegundos (p<0,001) e 7,6, 10,7 e 7,6 bpm (p=0,002) antes, durante e após a caminhada, respectivamente. Amédia dos números dos MAFs em 1 hora foi 29,9, 22,2 e 45,5, respectivamente, nos três momentos (p<0,001). Nas mulheres com sobrepeso/obesidade, a média da FCM foi menor (p=0,02). Após a análise de regressão logística, duas variáveis permaneceram significativamente associadas a bradicardia: aptidão maternal na 28a semana de gravidez (efeito protetor) e peso materno (aumento do risco). Conclusão Em fetos saudáveis, o exercício físico mostrou-se seguro, uma vez que, embora os BCFs e osMAFs diminuam durante a caminhada na esteira, foi observado um aumento da SVT e da LTV.


Asunto(s)
Humanos , Femenino , Adolescente , Adulto , Adulto Joven , Seguridad , Frecuencia Cardíaca Fetal/fisiología , Embarazo/fisiología , Ejercicio Físico/fisiología , Feto/fisiología , Tercer Trimestre del Embarazo/fisiología , Presión Sanguínea/fisiología , Cardiotocografía , Caminata/fisiología
4.
Rev. bras. ginecol. obstet ; 38(12): 589-592, Dec. 2016. tab
Artículo en Inglés | LILACS | ID: biblio-843886

RESUMEN

ABSTRACT Objective: We speculate that genetic racial disparity exists in fetal life and can be detected by modern computerized cardiotocography (cCTG) . Methods: This is a retrospective study comparing the results of the cCTG of pregnant patients at 37-42 weeks according to the parental ethnicity (black versus white). A cCTG was performed to analyze the variables of fetal heart rate (FHR). The cCTG variables analyzed were: percentage of signal loss; number of contractions; basal FHR; number of accelerations; number of decelerations; length of high variation episodes; short-term variability (STV); total trace duration time; and number of fetal active movements. Non-stress test (NST) parameters in the two groups were compared using the Mann-Whitney test for continuous data, and the Chi-square test for categorical variables. Results: We found a significantly lower number of active fetal movements (p 1/4 0.007) and longer periods of low variation (p 1/4 0.047) in the cCTG of black patients when compared with white patients. Conclusions: In conclusion, identifying the factors responsible for the variance in the objective analysis of CTG results is important to improve the outcomes of patients. Our study lends further evidence as to the importance of ethnicity in clinical cCTG interpretation.


RESUMO Objetivo: Especulamos que disparidade genética racial exist ana vida do feto, e que possa ser detectada por moderna cardiotocografia computadorizada (cCTG). Métodos: Estudo retrospective comparando resultados do cCTG de gestantes entre 37-42 semanas de gestação de acordo com etnicidade dos pais (negro vs. brancos). cCTG foi usado para analisar as variáveis a frequência cardíaca do feto (FHR). As variáveis abalizadas do cCTG foram o % de perda de sinal, número de contrações, basal FHR, número de acelerações, número de desacelerações, comprimento dos episódios de alta variação, viabilidade de curto prazo, tempo total de duração do rastreamento, e número de movimentos de atividade fetal. Os parâmetros do teste de não estresse (NST) em dois grupos foram comparados usando o teste de Mann-Whitney para dados contínuos e teste qui-square para variáveis categóricas. Resultados: Encontramos números significativamente mais baixos de movimentos de atividade fetal (p 1/4 0,007) e períodos mais longos de baixa variação (p 1/4 0,047) no cCTG de pacientes negros se comparados a pacientes brancos. Conclusões: Identificar fatores responsáveis pela variação na análise objetiva dos resultados de CTG é importante em resultados de pacientes que apresentam melhora. Nosso estudo fornece evidências adicionais à importância de estudos clínicos da etnicidade interpretada pelo cCTG.


Asunto(s)
Humanos , Femenino , Embarazo , Población Negra , Cardiotocografía/métodos , Diagnóstico por Computador , Población Blanca , Frecuencia Cardíaca Fetal/fisiología , Distribución de Chi-Cuadrado , Movimiento Fetal , Estudios Retrospectivos , Estadísticas no Paramétricas
5.
Rev. bras. ginecol. obstet ; 37(3): 133-139, 03/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-741855

RESUMEN

PURPOSE: To determine fetal heart rate (FHR) responses to maternal resistance exercise for the upper and lower body at two different volumes, and after 25 minutes post-exercise. METHODS: Ten pregnant women (22-24 weeks gestation, 25.2±4.4 years of age, 69.8±9.5 kg, 161.6±5.2 cm tall) performed, at 22-24, 28-32 and 34-36 weeks, the following experimental sessions: Session 1 was a familiarization with the equipment and the determination of one estimated maximum repetition. For sessions 2, 3, 4 and 5,FHR was determined during the execution of resistance exercise on bilateral leg extension and pec-deck fly machines, with 1 and 3 sets of 15 repetitions; 50% of the weight load and an estimated repetition maximum. FHR was assessed with a portable digital cardiotocograph. Results were analyzed using Student's t test, ANOVA with repeated measures and Bonferroni (α=0.05; SPSS 17.0). RESULTS: FHR showed no significant differences between the exercises at 22-24 weeks (bilateral leg extension=143.8±9.4 bpm, pec-deck fly=140.2±10.2 bpm, p=0.34), 28-30 weeks (bilateral leg extension=138.4±12.2 bpm, pec-deck fly=137.6±14.0 bpm, p=0.75) and 34-36 weeks (bilateral leg extension=135.7±5.8 bpm, pec-deck fly=139.7±13.3 bpm, p=0.38), between the volumes(bilateral leg extension at 22-24 weeks: p=0.36, at 28-30 weeks: p=0.19 and at 34-36 weeks: p=0.87; pec-deck fly at 22-24 weeks: p=0.43, at 28-30 weeks: p=0.61 and at 34-36 weeks: p=0.49) and after 25 minutes post-exercise. CONCLUSION: Results of this pilot study would suggest that maternal resistance exercise is safe for the fetus. .


OBJETIVO: O objetivo do presente estudo foi determinar a frequência cardíaca fetal (FCF) enquanto gestantes realizavam exercícios de força para os membros superiores e inferiores, com dois volumes diferentes, e 25 minutos pós-exercício. MÉTODOS: Dez gestantes (22-24 semanas, 25,2±4,4 anos, 69,8±9,5 kg, 161,6±5,2 cm) realizaram as seguintes sessões experimentais com 22-24, 28-32 e 34-36 semanas de gestação: A Sessão 1 foi a familiarização com os equipamentos e determinação de uma repetição máxima estimada. Para as Sessões 2, 3, 4 e 5, foi determinada a FCF durante a execução do exercício de força nos equipamentos extensão de joelhos bilateral e voador, com 1 e 3 séries de 15 repetições e carga de 50% de uma repetição máxima estimada. A FCF foi avaliada com um cardiotocógrafo digital portátil. Os resultados foram analisados com teste t de Student, ANOVA com medidas repetidas e Bonferroni (α=0,05; SPSS 17.0). RESULTADOS: A FCF não demonstrou diferença significativa entre os exercícios com 22-24 semanas (extensão de joelhos bilateral=143,8±9,4 bpm, voador=140,2±10,2 bpm, p=0,34), 28-30 semanas (extensão de joelhos bilateral=138,4±12,2 bpm, voador=137,6±14,0 bpm, p=0,75) e 34-36 semanas (extensão de joelhos bilateral=135,7±5,8 bpm, voador=139,7±13,3 bpm, p=0,38), entre os volumes (extensão de joelhos bilateral com 22-24 semanas: p=0,36, 28-30 semanas: p=0,19 e 34-36 semanas: p=0,87; voador com 22-24 semanas: p=0,43, 28-30 semanas: p=0,61 e 34-36 semanas: p=0,49) e 25 minutos pós-exercícios. CONCLUSÃO: Os resultados deste estudo piloto podem sugerir que o exercício de força materno é seguro para o feto. .


Asunto(s)
Humanos , Femenino , Embarazo , Adulto , Frecuencia Cardíaca Fetal/fisiología , Entrenamiento de Fuerza , Edad Gestacional , Proyectos Piloto
6.
Rev. Assoc. Med. Bras. (1992) ; 60(3): 270-275, May-Jun/2014. tab, graf
Artículo en Inglés | LILACS | ID: lil-713063

RESUMEN

Objective: the aim of this study was to investigate the patterns of transient FHR accelerations (10 bpm and 15 bpm) in the third trimester of pregnancy, comparing the occurrence of this event before and after the 32nd gestational week. Methods: This is a prospective study comparing the results of the computerized cardiotocography of 46 low-risk women with singleton pregnancies, maternal age between 18 and 40 years, gestational age between 28 and 40 weeks, absence of maternal morbidity and adequate fetal growth according to ultrasound. Computed Cardiotocography (8002 Sonicaid System and Fetal Care System) was performed for 30 minutes to analyze the variables of FHR. Results: twenty-three pregnant women underwent cardiotocography before 32 weeks (mean = 29.9 weeks, SD = 1.4 weeks) and were compared with 23 pregnant women who were examined after 32 weeks (mean = 36.3 weeks, SD = 2.5 weeks). Regarding the characteristics of FHR, fetuses evaluated between 32 1/7 weeks and 40 weeks showed a significantly greater number of accelerations above 15 bpm (median = 5, variation 0-18) than the group of pregnant women from 28 to 32 weeks (median = 4, variation 0 to 10; P = 0.048). There was a significant positive correlation between the number of accelerations above 15 bpm and the gestational age at examination (rho = 0.33; P = 0.026). Conclusion: computerized cardiotocography showed an association regarding the number of transient accelerations greater than 15 bpm in the assessment of both periods before and after 32 weeks of gestational age, suggesting the influence of the maturation of the fetal autonomic nervous system with pregnancy progression. .


Objetivo: o objetivo deste estudo foi investigar os padrões das acelerações transitórias da FCF (de 10 e 15 bpm) no terceiro trimestre da gestação, comparando a ocorrência desse evento antes e após a 32ª semana gestacional. Métodos: trata-se de estudo prospectivo comparando os resultados do exame de cardiotocografia computadorizada de 46 gestantes de baixo risco, com feto único, idade materna entre 18 e 40 anos, idade gestacional entre 28 e 40 semanas, ausência de morbidades maternas e crescimento fetal adequado pela ultrassonografia. Foi realizada a cardiotocografia computadorizada (Sonicaid System 8002 e Fetal Care System) por 30 minutos para análise das variáveis da FCF. Resultados: vinte e três gestantes que realizaram a cardiotocografia antes da 32ª semana (média = 29,9 semanas, DP = 1,4 semanas) foram comparadas com 23 que realizaram o exame após a 32ª semana (média = 36,3 semanas, DP = 2,5 semanas). Quanto às características da FCF, os fetos avaliados entre 32 1/7 semanas e 40 semanas apresentaram número significativamente maior de acelerações acima de 15 bpm (mediana = 5, variação 0 a 18) que o grupo de gestantes de 28 a 32 semanas (mediana = 4, variação 0 a 10; P = 0,048). Houve correlação significativa e positiva entre o número de acelerações transitórias acima de 15 bpm e a idade gestacional no momento do exame (rho = 0,33; P = 0,026). Conclusão: a cardiotocografia computadorizada revelou associação entre o número de acelerações transitórias acima de 15 bpm quando avaliados os períodos antes e após 32 semanas de idade gestacional, sugerindo influência da maturação do sistema nervoso autônomo fetal com a progressão da gestação. .


Asunto(s)
Adolescente , Adulto , Femenino , Humanos , Embarazo , Adulto Joven , Cardiotocografía/instrumentación , Movimiento Fetal/fisiología , Frecuencia Cardíaca Fetal/fisiología , Edad Gestacional , Tercer Trimestre del Embarazo , Estudios Prospectivos
7.
Ann Card Anaesth ; 2014 Jan; 17(1): 33-39
Artículo en Inglés | IMSEAR | ID: sea-149689

RESUMEN

Cardiac surgery carried out on cardiopulmonary bypass (CPB) in a pregnant woman is associated with poor neonatal outcomes although maternal outcomes are similar to cardiac surgery in non‑pregnant women. Most adverse maternal and fetal outcomes from cardiac surgery during pregnancy are attributed to effects of CPB. The CPB is associated with utero‑placental hypoperfusion due to a number of factors, which may translate into low fetal cardiac output, hypoxia and even death. Better maternal and fetal outcomes may be achieved by early pre‑operative optimization of maternal cardiovascular status, use of perioperative fetal monitoring, optimization of CPB, delivery of a viable fetus before the operation and scheduling cardiac surgery on an elective basis during the second trimester.


Asunto(s)
Adulto , Anestésicos , Procedimientos Quirúrgicos Cardíacos , Puente Cardiopulmonar/métodos , Circulación Extracorporea , Femenino , Frecuencia Cardíaca Fetal/fisiología , Edad Gestacional , Paro Cardíaco Inducido , Implantación de Prótesis de Válvulas Cardíacas , Humanos , Monitoreo Intraoperatorio/métodos , Placenta/sangre , Embarazo/fisiología , Resultado del Embarazo , Útero/sangre , Útero/fisiología
9.
Artículo en Inglés | IMSEAR | ID: sea-157483

RESUMEN

Background : Heart rate variations in fetus subjected to adverse environment provides assessment of health status. Aim : The present study is conducted to assess the efficacy of this tool in selecting high risk mother with compromised fetus at an early stage. Methods and Material : Hospital based case control study. High risk pregnancies attending hospital over a period of one year were considered for purpose of test. Normal patient were served as control. 80 high risk and 20 normal patient were considered for the study. The subjects were explained the test, need of the test, done after 28 wks. of gestation. Statistical Analysis : Sensitivity, specificity, negative predictive and positive predictive value, false positive and false negative rate were assessed. Result : Test has high sensitivity and specificity with high negative predictive value.


Asunto(s)
Aceleración , Femenino , Monitoreo Fetal/métodos , Movimiento Fetal , Edad Gestacional , Frecuencia Cardíaca Fetal/fisiología , Humanos , Valor Predictivo de las Pruebas , Embarazo , Embarazo de Alto Riesgo/análisis , Embarazo de Alto Riesgo/epidemiología
10.
Journal of Korean Medical Science ; : 794-798, 2012.
Artículo en Inglés | WPRIM | ID: wpr-210926

RESUMEN

The purpose of this study was to investigate the feasibility of different fetal heart rate (FHR) ranges in the nonstress test (NST) and to better understand the meaning of mild bradycardia and/or tachycardia without non-reassuring patterns. We employed the heredity to show that mild bradycardia (100-119 beats per minute, bpm) and mild tachycardia (161-180 bpm) regressed to the normal FHR range (120-160 bpm). We used linear regression to analyze FHR data from FHR tracings recorded 10 min before (NST, as the predictor) and 10 min after vibroacoustic stimulation testing (as the dependent variable). Acceleration for 15 bpm-15 seconds (Acc1515) and deceleration for 15 bpm-15 seconds (Dec1515) in the NST were also analyzed for each group. The slope of the best-fit line was the largest in the mild bradycardia group and the smallest in the normal range group. Dec1515 was most prominent in mild tachycardia and both the mild bradycardia and tachycardia groups regressed towards the mean FHR range. Therefore, we propose that both mild bradycardia and tachycardia of FHR in non-acute situations (range between 100 and 180 bpm) are not regarded a pathologic signal for clinical use.


Asunto(s)
Femenino , Humanos , Embarazo , Estimulación Acústica , Bradicardia/fisiopatología , Monitoreo Fetal , Frecuencia Cardíaca Fetal/fisiología , Tercer Trimestre del Embarazo , Análisis de Regresión , Taquicardia/fisiopatología
11.
Femina ; 39(12)dezembro.
Artículo en Portugués | LILACS | ID: lil-641398

RESUMEN

A avaliação do bem-estar fetal durante assistência ao trabalho de parto é um dos principais objetivos da Obstetrícia. O método mais utilizado para essa avaliação é a monitorização eletrônica fetal contínua. Em razão de sua limitada capacidade diagnóstica, outros métodos complementares têm sido investigados para esse fim, como a ausculta intermitente, a estimulação digital no escalpe fetal, a oximetria de pulso, o eletrocardiograma fetal e a coleta de amostras de sangue do couro cabeludo fetal. Após revisão da literatura, foi concluído que são necessários mais estudos para determinar a verdadeira utilidade, na prática clínica, dos métodos complementares à monitorização eletrônica fetal contínua para avaliação fetal intraparto.


The evaluation of intrapartum fetal well-being is one of the main objectives of Obstetrics. The most used method for this assessment is the continuous electronic fetal monitoring. Because of their limited diagnostic capabilities, other complementary methods have been investigated for evaluation of intrapartum surveillance, as intermittent auscultation, digital fetal scalp stimulation, pulse oximetry, fetal electrocardiogram and fetal scalp blood sample. After a review of articles, we concluded that more studies are needed to determine the true usefulness in clinical practice of complementary methods to continuous electronic fetal monitoring for intrapartum fetal monitoring.


Asunto(s)
Humanos , Femenino , Embarazo , Cardiotocografía , Cuero Cabelludo/irrigación sanguínea , Electrocardiografía , Frecuencia Cardíaca Fetal/fisiología , Trabajo de Parto , Monitoreo Fetal/métodos , Monitoreo Fetal , Sufrimiento Fetal/diagnóstico
12.
Femina ; 39(6): 303-312, jun. 2011. ilus, tab
Artículo en Portugués | LILACS | ID: lil-613324

RESUMEN

O nascimento de um feto saudável sempre constituiu um dos principais objetivos da Obstetrícia. Nos dias atuais, vários procedimentos têm sido utilizados com esta finalidade, porém, apesar da evolução dos métodos diagnósticos e da melhor compreensão da fisiopatologia do sofrimento fetal, ainda existem lacunas no conhecimento sobre o comportamento do feto frente à hipóxia. Outro fator complicador na avaliação do sofrimento fetal é o grande número de doenças maternas com diferentes fisiopatologias que podem interferir no bem-estar fetal. Esta revisão tem como objetivo descrever os principais métodos de avaliação biofísica da vitalidade fetal, com base nas melhores evidências científicas correntemente disponíveis na literatura, e incluindo níveis de evidências e graus de recomendação. Será abordada a avaliação da vitalidade fetal nos casos de insuficiência placentária, não sendo estudadas as situações especiais, como diabetes e gestação múltipla. Evidencia-se uma falta de consenso sobre qual procedimento deve ser utilizado na avaliação da vitalidade fetal, na prática clínica diária. As sociedades internacionais recomendam a realização da doplervelocimetria, da cardiotocografia e do perfil biofísico fetal apenas em gestantes de alto risco, com suspeita de insuficiência placentária ou com restrição de crescimento intrauterino


The birth of a healthy baby has always been an important goal of Obstetrics. Nowadays, many procedures have been used for this purpose, but despite great development in diagnostic methods and better understanding of pathophysiology of fetal distress, there are still gaps in knowledge about fetal behavior in situations of hypoxia. Another complicating factor in the assessment of fetal distress is the large number of maternal diseases with different pathophysiology, which can compromise fetal well-being. This review aims at describing the main methods for fetal assessment, based on the best scientific evidence currently available, including levels of evidence and grades of recommendation. Only fetal evaluation in cases of placental insufficiency will be addressed, and special situations such as diabetes and multiple pregnancies will not be studied. Current evidences show a lack of consensus on what is the best procedure to assess fetal well-being in clinical practice. International societies recommend the performance of Doppler velocimetry, cardiotocography, and fetal biophysical profile only in high-risk pregnancies with suspected placental insufficiency or restricted intrauterine growth


Asunto(s)
Humanos , Femenino , Embarazo , Cardiotocografía , Desarrollo Fetal , Monitoreo Fetal/métodos , Sufrimiento Fetal/diagnóstico , Sufrimiento Fetal/fisiopatología , Ultrasonografía Doppler/métodos , Frecuencia Cardíaca Fetal/fisiología , Hipoxia Fetal/prevención & control , Insuficiencia Placentaria/diagnóstico , Embarazo de Alto Riesgo , Fenómenos Biofísicos/fisiología
13.
Rev. bras. eng. biomed ; 24(2): 91-98, ago. 2008. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-576305

RESUMEN

A análise acurada da frequência cardíaca fetal (FCF) correlacionada com as contrações uterinas permite diagnosticar, e consequentemente antecipar, diversos problemas relativos ao bem estar fetal e à preservação de sua vida. O presente trabalho apresenta os resultados de um sistema híbrido, baseado em regras determinísticas e em um módulo de inferência nebuloso do tipo Mamdani, para análise de sinais coletados através de exames denominados cardiotocografias (CTG). As variáveis analisadas são: o valor basal da FCF, suas variabilidades de curto e de longo prazo, acelerações transitórias e desacelerações, sendo estas classificadas por seu tipo e número de ocorrências. São utilizados dois modelos de classificação. A saída do sistema, em qualquer dos modelos, é um diagnóstico de primeiro nível baseado nestas variáveis de entrada. O sistema inteligente para auxílio ao diagnóstico no monitoramento fetal eletrônico por análise de cardiotocografias (SISCTG) foi desenvolvido na linguagem de scripts do programa MATLAB® v.7. O projeto conta também com uma parceria multi-institucional entre o Brasil e a Alemanha, envolvendo o Departamento de Engenharia de Teleinformática (DETI) da Universidade Federal do Ceará (UFC), a Maternidade-Escola Assis Chateaubriand (MEAC), a Technische Universitãt München e a empresa alemã Trium GmbH, que fornece a base de dados utilizada neste trabalho. Os resultados apresentados pelo SISCTG mostram-se promissores, com um índice de acertos (comparando-se os dois modelos utilizados) variando de 83% a 100%, de acordo com o tipo de diagnóstico. Isto permite projetar o aprimoramento deste sistema com novas variáveis de entrada (como a entropia aproximada da FCF e da sua variabilidade). A validação do sistema contou com especialistas brasileiros e alemães na área obstétrica.


The accurate analysis of the fetal heart rate (FHR) and its correlation with uterine contractions (UC) allow the diagnostic and the anticipation of many problems related to fetal distress and the preservation of its life. This paper presents the results of a hybrid system based on a set of deterministic rules and fuzzy inference system developed to analyze FHR and UC signals collected by cardiotocography (CTG) exams. The studied variables are basal FHR, short and long-term FHR variability, transitory accelerations and decelerations, these lasts classified by their type and number of occurrences. Two classification models are used. For both models, the system output is a first level diagnostic based on those input variables. The system is developed using the MATLAB® v.7 script language. The project is also supported by a multi-institutional agreement between Brazil and Germany, among the DETI (Departamento de Engenharia de Teleinformática of the Universidade Federal do Ceará), the MEAC (Maternidade-Escola Assis Chateaubriand), the TUM (Technische Universitãt München), and the Trium GmbH, a German company who supplied the database used in this project. The results are very promising with a diagnostic accuracy (considering the two models used) varying from 83% to 100%, according to the type of diagnostic. These results allow the projection of refinements of the proposed system, inserting new input variables (such as the approximate entropy of the FHR and its variability). The system validation methodology was based on the knowledge of Brazilian and German obstetricians.


Asunto(s)
Cardiotocografía/instrumentación , Cardiotocografía , Diagnóstico Prenatal/instrumentación , Frecuencia Cardíaca Fetal/fisiología , Sistemas Especialistas/instrumentación , Contracción Uterina/fisiología , Lógica Difusa , Monitoreo Fetal/instrumentación , Procesamiento de Señales Asistido por Computador/instrumentación
14.
Femina ; 35(8): 521-527, ago. 2007. tab
Artículo en Portugués | LILACS | ID: lil-481965

RESUMEN

Apesar das recomendações para a prática de exercícios físicos durante a gestação já estarem bem estabelecidas entre os profissionais de saúde, vários estudos vêm sendo realizados com objetivo de demonstrar que o exercício durante a gravidez é benéfico tanto para mãe como para o feto. Entretanto, existem controvérsias em relação a potenciais efeitos deletérios. Os principais questionamentos a respeito do tema dizem respeito ao parto prematuro e a redução do fluxo sanguíneo feto-placentário. O objetivo desta revisão é apresentar uma atualização sobre as recomendações da prática do exercício físico durante a gravidez e suas repercussões sobre os resultados maternos e fetais. Medline, Lilacs?Scielo e a Biblioteca Cochrane, foram consultadas usando os termos exercício, atividade física, gestação e resultados perinatais.


Asunto(s)
Embarazo , Peso al Nacer , Desarrollo Fetal/fisiología , Diabetes Gestacional/prevención & control , Ejercicio Físico/fisiología , Frecuencia Cardíaca Fetal/fisiología , Bienestar Materno , Buceo/efectos adversos , Resultado del Embarazo , Preeclampsia/prevención & control , Salud Materno-Infantil
16.
Rev. bras. ginecol. obstet ; 26(1): 15-20, jan.-fev. 2004. tab
Artículo en Portugués | LILACS | ID: lil-358151

RESUMEN

OBJETIVO: analisar os valores dos parâmetros dopplerfluxométricos do ducto venoso, entre a 10ª e a 14ª semana de gestação, durante as diferentes fases do ciclo cardíaco: sístole ventricular (onda S), diástole ventricular (onda D), contração atrial (onda a) e dos índices ângulo-independentes. MÉTODOS: foi desenvolvido estudo prospectivo e transversal que examinou 276 gestações únicas. Foram excluídas as gestações múltiplas, malformações fetais, fetos com translucência nucal aumentada e gestantes com doenças associadas. O equipamento utilizado foi Toshiba, modelo SSH-140 A. A análise espectral foi obtida de acordo com os procedimentos padronizados: ângulo de insonação menor que 30º e uso de filtro de 50-70 Hz. O ducto venoso foi identificado em corte sagital e ventral do abdome superior fetal com o Doppler colorido. A amostra de volume (1-2 mm ) foi adquirida imediatamente na origem do ducto venoso. Pelo menos três ondas nítidas e consecutivas foram necessárias para aferição dos parâmetros. Para o estudo estatístico foi realizado o teste de Levene e o método de Bonferroni. RESULTADOS: foi observado aumento na velocidade S de 29 cm/s para 37 cm/s (p=0,013) entre a 10ª e a 14ª semana de gestação. Similarmente, houve aumento na velocidade D (de 25 cm/s para 32 cm/s, p=0,026). A onda a, o índice de pulsatilidade e a relação S/a apresentaram valores constantes no período estudado. CONCLUSAO: os valores estabelecidos por este estudo podem servir para acompanhamento dopplerfluxométrico de gestações normais. Futuros estudos são necessários para determinar a validade destes parâmetros na população normal e, em particular, para fetos de risco.


Asunto(s)
Humanos , Femenino , Embarazo , Adulto , Persona de Mediana Edad , Frecuencia Cardíaca Fetal/fisiología , Ultrasonografía Doppler , Venas Umbilicales , Edad Gestacional , Primer Trimestre del Embarazo , Venas
17.
Artículo en Inglés | IMSEAR | ID: sea-45560

RESUMEN

Fetal echocardiogram has developed into a reliable tool for prenatal diagnosis of congenital heart disease. It is also used to evaluate ventricular function. Recently, Tissue Doppler Imaging (TDI) has been introduced to evaluate ventricular functions especially in ischaemic heart disease. The objective of this study was to evaluate myocardial velocities and heart motions of the normal fetal heart by using TDI. The TDI was preformed in 28 fetal hearts with a gestational age of 20-35 wks (Mean 29 +/- 3.7 wks) to evaluate myocardial velocities and heart motion. The Toshiba, Power Vision, machine with 3.75 and 5 MHz transducers was used with an appropriate setting of colour-coded tissue velocities. The apical four chamber and apical or parasternal long axis views were the standard planes for measuring myocardial velocities and evaluating the heart motions. The results showed the myocardial velocities of the posterior wall of the left ventricle during the early, mid, and late systolic phases were 1.5 +/- 0.2, 2.1 +/- 0.9, and 1.0+0.5 cm/sec and early, mid, and late diastolic phases were 1.3 +/- 0.7, 1.9 +/- 0.8, and 1.1 +/- 0.7 cm/sec respectively. The myocardial velocity of the anterior wall of the right ventricle during the early, mid, and late systolic phases were 1.7 +/- 0.9, 1.7 +/- 0.6, and 1.0 +/- 0.6 cm/sec and early, mid, and late diastolic phases were 1.1 +/- 0.6, 1.8 +/- 0.7, and 1.5 +/- 1.0 cm/sec respectively. The myocardial velocity of the interventricular septum could not be measured due to the abnormal septal motion and the total fetal heart movement during the cardiac cycle. The fetal heart had anterior displacement during systole and posterior translation during diastole and also had counter-clockwise rotation during the systolic phase. CONCLUSION: Using the TDI to evaluate myocardial velocities of the fetal heart is limited by the angle of ultrasound beam and the total fetal heart motion. The fetal heart movement is similar to the newborn or young adult heart.


Asunto(s)
Adulto , Sesgo , Velocidad del Flujo Sanguíneo/fisiología , Diástole/fisiología , Ecocardiografía Doppler en Color/instrumentación , Femenino , Corazón Fetal/fisiología , Edad Gestacional , Frecuencia Cardíaca Fetal/fisiología , Humanos , Recién Nacido , Embarazo , Segundo Trimestre del Embarazo , Tercer Trimestre del Embarazo , Valores de Referencia , Sístole/fisiología , Factores de Tiempo , Ultrasonografía Prenatal/instrumentación , Función Ventricular/fisiología
18.
Artículo en Inglés | IMSEAR | ID: sea-42644

RESUMEN

The purpose of this study was to examine the correlation between the fetal heart rate at 10-14 weeks and birthweight at term. At the fetal medicine unit, Ramathibodi Hospital, the screening for Down's syndrome at 10-14 weeks' gestation by ultrasound has been ongoing since January 1997. Transabdominal ultrasound examination is routinely performed for the crown-rump length, nuchal translucency thickness and fetal heart rate. The fetal heart rate is measured over four to six cardiac cycles by using the pulsed Doppler technique. One thousand and fourteen term singleton pregnancies that resulted in phenotypically normal live births were studied. The study was done was carried out at 10-14 weeks of gestation (mean 12.27 weeks) from January 1997 to November 1997. The mean patient age was 26.78 years old. The mean gestational age and birthweight were 38.83 weeks and 3,097.83 grams respectively. The incidence of low birthweight (less than 2,500 grams) was 14.2 per cent. Regression analysis demonstrated no significant relation between fetal heart rate at 10-14 weeks and birthweight at term. In conclusion, the result of this study revealed that there was no correlation of the fetal heart rate at 10-14 weeks' gestation and birthweight at term.


Asunto(s)
Adulto , Peso al Nacer , Desarrollo Embrionario y Fetal , Femenino , Monitoreo Fetal/métodos , Edad Gestacional , Frecuencia Cardíaca Fetal/fisiología , Humanos , Recién Nacido de Bajo Peso , Recién Nacido , Masculino , Embarazo , Primer Trimestre del Embarazo , Análisis de Regresión , Sensibilidad y Especificidad , Ultrasonografía Prenatal
19.
Journal of the Royal Medical Services. 2000; 7 (1): 18-21
en Inglés | IMEMR | ID: emr-54227

RESUMEN

To evaluate the prognostic value of detecting fetal heart activity in cases of threatened abortion occurring early in the first trimester, and consequently to demonstrate the importance of ultrasonography in the routine management of vaginal bleeding in early pregnancy. Two hundred and sixteen patients were enrolled in this study. They were all seen in the first attack of vaginal bleeding, occurring in the first trimester. Fetal cardiac activity was demonstrated by the use of abdominal ultrasound on the first visit. They all had singleton pregnancy. There was neither history of recurrent abortion, nor intake of anticoagulant drugs. The patients were then seen weekly or whenever bleeding recurred. No drugs were given. Out of the 216 cases, 193 [89.4%] continued to full-term delivery. Twenty three cases [10.6%] aborted during the first or second trimester. Premature delivery, congenital abnormalities and cesarean section rates were not significantly different from the expected averages of the general population. Eighteen of these 23 cases of fetal loss started bleeding in the late weeks of the first trimester [10th - 12th week]. At the first attack of vaginal bleeding occurring in the first trimester, if the cervix is closed and a living fetus could be demonstrated, the pregnancy should be considered viable and the outlook for fetal survival is favorable. Sonographic demonstration of fetal cardiac activity is assuring, indicating a low risk of subsequent abortion and a favorable prognosis


Asunto(s)
Humanos , Femenino , Amenaza de Aborto/diagnóstico por imagen , Ultrasonografía/instrumentación , Corazón Fetal/fisiología , Frecuencia Cardíaca Fetal/fisiología
20.
Scientific Journal of Al-Azhar Medical Faculty [Girls] [The]. 1999; 20 (Supp. 1): 1079-1088
en Inglés | IMEMR | ID: emr-52628

RESUMEN

This study aimed to evaluate the usefulness of tumor necrosis factor alpha [TNF-alpha] and interleukin 6 [IL-6] in identifying women with preterm labor and at risk for tocolytic failure. It was conducted on 100 pregnant women with threatened preterm labor and intact membrane. The cases were divided into two groups: Group one included 35 women with failed response to tocolysis and group two consisted of 65 women with successful tocolytic response. Human cervicovaginal TNF-alpha and IL-6 were assessed in both groups. A significant higher value of TNF-alpha was found in group one with 100% sensitivity and 89% specificity in identifying women who failed tocolysis and IL-6 was significantly high in group one. Cervicovaginal IL-6 > 200 pg/ml identified women who failed tocolysis with 88.9% sensitivity and 50.5% specificity, so it is sensitive but not specific in predicting tocolytic response


Asunto(s)
Humanos , Femenino , Biomarcadores , Factor de Necrosis Tumoral alfa , Tocolíticos , Interleucina-6 , Frecuencia Cardíaca Fetal/fisiología , Trabajo de Parto Prematuro/etiología
SELECCIÓN DE REFERENCIAS