1.
Rev. latinoam. enferm. (Online) ; 24: e2805, 2016. tab, graf
Artículo en Inglés | LILACS, BDENF, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: biblio-960950

RESUMEN

ABSTRACT Objectives: to determine if there are differences on the safety of the preparation of clean surgical instruments using different types of gloves and bare hands and evaluate the microbiological load of these preparations without gloves. Method: laboratory procedure with a pragmatic approach, in which the samples were handled with different types of gloves and bare hands. In addition, cytotoxicity assays were carried out by means of the agar diffusion method. Further samples were subjected to microbiological analysis after being handled without gloves. Results: none of the samples showed cytotoxic effect. All microbiological cultures showed growth of microorganisms, but no microorganism has been recovered after autoclaving. Conclusion: there were no differences in the cytotoxic responses regarding the use of different types of gloves and bare hands in the handling of clean surgical instruments, which could entail iatrogenic risk. It is noteworthy that the use of gloves involves increase in the costs of process and waste generation, and the potential allergenic risk to latex.


RESUMO Objetivos: determinar se existe diferenças na segurança do preparo de instrumentais cirúrgicos relacionada ao uso de distintos tipos de luvas e das mãos nuas no preparo, e avaliar a carga microbiológica destes preparados sem luvas. Método: experimento laboratorial com abordagem pragmática, onde amostras foram manipuladas com diferentes tipos de luvas e com as mãos nuas, elaborado teste de citotoxicidade por meio da difusão em ágar. Outras Amostras sofreram análise microbiológica após serem manipuladas sem luvas. Resultados: nenhuma das amostras apresentou efeito citotóxico. Todas as culturas microbiológicas apresentaram crescimento de microrganismos, embora nenhum microrganismo tenha sido recuperado após a autoclavação. Conclusão: não houve diferenças nas respostas citotóxicas relacionadas ao uso de diferentes tipos de luvas e das mãos nuas na manipulação do instrumental cirúrgico limpo que sinalizasse risco de iatrogenia. Ressalta-se que o uso de luvas implica em aumento dos custos do processo e da geração de resíduos, além do potencial risco alergênico ao látex.


RESUMEN Objetivos: determinar si existen diferencias en la seguridad de la preparación del instrumental quirúrgico relacionadas con el uso de diferentes tipos de guantes y de las manos desnudas y evaluar la carga microbiológica de estos preparados sin guantes. Método: experimento de laboratorio con enfoque pragmático, en el que las muestras fueron manejadas con diferentes tipos de guantes y las manos desnudas. Además, un ensayo de citotoxicidad se llevó a cabo mediante el método de difusión en agar. Otras muestras fueron sometidas a análisis microbiológico después de haber sido manipuladas sin guantes. Resultados: ninguna de las muestras presentó efecto citotóxico. Todos los cultivos microbiológicos mostraron crecimiento de microorganismos, pero ningún microorganismo ha sido recuperado después de la esterilización en autoclave. Conclusión: no hubo diferencias en las respuestas citotóxicas con respecto al uso de diferentes tipos de guantes y de las manos desnudas en el manejo del instrumental quirúrgico limpio, lo que podría conllevar riesgo de yatrogenia. Es de destacar que el uso de guantes implica un aumento de los costos del proceso y la generación de residuos, además del potencial riesgo alergénico al látex.


Asunto(s)
Humanos , Instrumentos Quirúrgicos , Contaminación de Equipos/prevención & control , Guantes Quirúrgicos/clasificación , Esterilización , Mano
2.
Artículo en Inglés | IMSEAR | ID: sea-141220

RESUMEN

Addition silicone impression materials have been used as impression material for more than 20 years. Although they are among the most expensive impression materials, they became popular during the past decade as they have excellent physical properties. Prevention of infection is an important aspect in dental treatment since dental professionals are routinely exposed to the wide variety of microorganisms present in saliva. Gloves are the most common protective measure used during dental treatment. The gloves are mostly made of latex. In this study, we examine how the setting time of three types polyvinyl putty materials were affected by the use of five different brands of latex gloves and one brand of vinyl gloves. Each material was first mixed without wearing gloves according to the manufacturer's instructions. After the stipulated mixing time, the setting time was measured using the Vicat needle. The setting time is measured from the time of mixing till the time that the needle does not produce any indentation on the surface of the material. The putty material was then mixed with gloved hands (using the five different brands of latex gloves in turn) and the setting time was measured. Then the material was mixed with washed gloved hands, and the setting time was measured again. Finally, the material was mixed with vinyl gloved hands and the setting time was measured. The following conclusions were drawn from the study: Reprosil™ and Express™ showed significant variation in the setting time with the latex gloved hands. There was no significant variation in the setting time when material was mixed with unwashed vs washed gloved hands. Vinyl gloves did not significantly affect the setting time of any of the putty impression materials.


Asunto(s)
Materiales de Impresión Dental/química , Guantes Quirúrgicos/clasificación , Dureza , Humanos , Látex/química , Ensayo de Materiales , Polimerizacion , Polivinilos/química , Siloxanos/química , Jabones/química , Propiedades de Superficie , Factores de Tiempo , Compuestos de Vinilo/química
3.
ACM arq. catarin. med ; 37(3): 34-38, 2008. tab
Artículo en Portugués | LILACS | ID: lil-503676

RESUMEN

A integridade das luvas cirúrgicas durante procedimentos de Cirurgia Bucal pode sofrer avarias. Dentro desse contexto, a reutilização das mesmas, seja para procedimentos invasivos ou não invasivos, prática ainda usada em alguns setores de saúde, que alegam ganho financeiro devido a poucos recursos disponíveis, é um risco desnecessário para o profissional e para o paciente. Assim, esse estudo teve como objetivo avaliar a eficiênciados testes de inspeção visual, auditiva e tátil, bem como variações dessas técnicas, empregados na detecçãode perfurações em luvas cirúrgicas. Quarenta pares de luvas cirúrgicas receberam perfurações com diferentesmateriais pérfuro-cortantes e foram submetidos a diferentes testes para avaliar a eficiência dos mesmos na detecção das perfurações. Os resultados mostram que os testes comumente utilizados para verificação de perfurações em luvas cirúrgicas, não são capazes de detectar todas as perfurações. Os achados demonstramque está totalmente contra-indicada a reutilização de luvas, sendo um risco desnecessário para o profissional e o paciente.


The integrity of the surgical gloves during procedures of Oral Surgery can suffer damages. Inside of this context, reuse of same for invasive or not invasive procedures, practice used in some health sectors who makeuse of it justify such practice through financial benefits an unnecessary risk both to the professional and the patient.Thus, this study aimed to evaluate the effectiveness of the visual, auditory and tactile, as well as variations of these techniques, inspection tests used in thedetection of perforations in surgical gloves. Forty pairs of surgical gloves have holes with different perforationsmaterials and were subjected to various tests to assess the efficiency of them in detection of holes. The results show that the tests commonly used about to verification of perforations in surgical gloves, are not capable of detectingall the perforations. The finds demonstrate that is fully not indicated the reuse of gloves, being an unnecessary risk about to the professional and the patient.


Asunto(s)
Contención de Riesgos Biológicos , Contaminación Ambiental , Equipo Reutilizado , Guantes Quirúrgicos , Procedimientos Quirúrgicos Orales , Contaminación Ambiental/prevención & control , Indicadores de Contaminación/análisis , Indicadores de Contaminación/prevención & control , Guantes Quirúrgicos/clasificación , Guantes Quirúrgicos , Guantes Quirúrgicos/estadística & datos numéricos , Guantes Quirúrgicos , Procedimientos Quirúrgicos Orales/clasificación , Procedimientos Quirúrgicos Orales/educación , Equipo Reutilizado/estadística & datos numéricos
4.
Col. med. estado Táchira ; 4(2): 60-2, nov. 1995. tab
Artículo en Español | LILACS | ID: lil-259262

RESUMEN

En la presente comunicación los autores, expresan los resultados obtenidos después de evaluar 2180 guantes quirúrgicos de látex, usados en áreas quirúrgicas y emergencia general, encontrándose con un 18,23 por ciento de guantes rotos o perforados. Al mismo tiempo se expresa la importancia de la calidad de los guantes utilizados en función del grosor de los mismos


Asunto(s)
Humanos , Masculino , Femenino , Guantes Quirúrgicos/clasificación , Guantes Quirúrgicos , Medición de Riesgo/estadística & datos numéricos , Control de Calidad , Rotura/complicaciones
5.
Rev. Fac. Odontol. Bauru ; 1(1/4): 60-6, jan.-dez. 1993. tab
Artículo en Portugués | LILACS, BBO | ID: lil-179792

RESUMEN

O presente trabalho visa alertar os cirurgiöes-dentistas para os perigos de transmissäo das doenças infecto-contagiosas no consultório odontológico e corrigir suas técnicas operatórias, visando o controle da infecçäo cruzada. Foram avaliados dispositivos de biossegurança, como máscaras faciais, máscaras retangulares e ovais, óculos e luvas existentes no comércio nacional. As luvas foram avaliadas com relaçäo à incidência de micro-perfuraçöes e localizaçäo dessas por horas de trabalho, e os outros dispositivos foram avaliados em relaçäo à eficiência, visibilidade e comodidade. Todos os dispositivos testados foram aprovados e indicados por serem eficientes


Asunto(s)
Control de Enfermedades Transmisibles/métodos , Consultorios Odontológicos , Equipos de Seguridad , Contaminación de Equipos/prevención & control , Dispositivos de Protección de los Ojos/clasificación , Dispositivos de Protección de los Ojos/estadística & datos numéricos , Dispositivos de Protección de los Ojos , Equipos de Seguridad/clasificación , Equipos de Seguridad/estadística & datos numéricos , Guantes Quirúrgicos/clasificación , Guantes Quirúrgicos/estadística & datos numéricos , Guantes Quirúrgicos , Máscaras/clasificación , Máscaras/estadística & datos numéricos , Máscaras
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA