Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Acta cir. bras ; 35(5): e202000505, 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1130643

RESUMEN

Abstract Purpose The objective of this study was to investigate the accuracy of 18F-FDG-PET in the diagnosis of multibacterial abdominal sepsis by cecum ligation and puncture (CLP) in rats. Methods Adult Wistar rats ( Rattus norvegicus ), weighing 227±35g, were allocated into a sepsis group by CLP (n=10) and sham group (n=10). 18F-FDG-PET using microPET was performed on all rats after 24 hours. Results All animals survived for postoperative 24h. The abdomen/liver ratio of the standardized uptake value (SUV) percentage was significantly higher in the sepsis group than in the sham (p=0.004). The ROC curve showed an accuracy of 18F-FDG-PET to detect abdominal sepsis of 88.9% (p=0.001), sensitivity of 90% and specificity of 88.9%. When a cut-off point of 79% of the ratio between the SUV on the abdominal region and liver was established, the sensitivity was 90%, specificity of 88.9%; positive and negative predictive values of 90.0% and 88.9%, respectively. Conclusions The diagnostic accuracy of 18F-FDG-PET in rats with abdominal sepsis was significantly high. It was also demonstrated the predictive ability of the abdomen/liver SUV ratio to diagnose abdominal sepsis. These findings may have implications for the clinical setting, locating septic foci with PETscan.


Asunto(s)
Sepsis/diagnóstico por imagen , Radiofármacos , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Infecciones Intraabdominales/diagnóstico por imagen , Valores de Referencia , Factores de Tiempo , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Ratas Wistar , Sepsis/patología , Infecciones Intraabdominales/patología
2.
Acta cir. bras ; 32(3): 175-181, Mar. 2017. graf
Artículo en Inglés | LILACS | ID: biblio-837692

RESUMEN

Abstract Purpose: To examine a correlation of micro-PET images with photographic images of the digestive organs in abdominal sepsis model. Methods: Male Wistar rats weighing 265±18g were used. Abdominal sepsis was induced by ligature and cecal puncture. Micro-PET Images from abdominal cavity septic foci were obtained using 18-Fluoro-deoxyglucose, looking for a correlation with photographic images of abdominal cavity organs. Pearson's correlation test was used. Results: The mean standard uptake values (SUV) and lesion areas were 2.58±0.63SUVbwg/ml and 546.87±300.95mm2, respectively. There was a strong positive correlation between the two variables (r=0.863, p=0.137), which resulted in a coefficient of determination r2?0.75, meaning that 75% of SUV variation is explained by the lesion areas of digestive organs. Conclusion: Micro-PET allows high throughput assessment of lesion count and volume in pre-clinical rat model of CPL abdominal sepsis.


Asunto(s)
Animales , Masculino , Sepsis/diagnóstico por imagen , Radiofármacos , Fluorodesoxiglucosa F18 , Tomografía de Emisión de Positrones/métodos , Infecciones Intraabdominales/diagnóstico por imagen , Factores de Tiempo , Reproducibilidad de los Resultados , Ratas Wistar , Sepsis/patología , Sistema Digestivo/patología , Sistema Digestivo/diagnóstico por imagen , Modelos Animales de Enfermedad , Fotografía , Infecciones Intraabdominales/patología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA