Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Rev. bras. cir. plást ; 30(1): 129-133, 2015. ilus
Artículo en Inglés, Portugués | LILACS | ID: biblio-872

RESUMEN

A lipoenxertia de face, apesar de consagrada, não é isenta de riscos e complicações. Neste relato de caso, descrevemos de forma inédita uma complicação isquêmica local, causada por enxerto de gordura. Simultaneamente, propomos a terapêutica com Oxigenioterapia Hiperbárica para o tratamento desta situação, não se limitando exclusivamente à gordura, mas principalmente ao PMMA, em que esta complicação é muito mais frequente.


Facial fat grafting is not devoid of risks and complications, despite being a widely practiced procedure. In this case report, we describe a novel form of local ischemic complication that occurred secondary to fat grafting. Simultaneously, we propose Hyperbaric Oxygen therapy for the treatment of this situation. We propose that Hyperbaric Oxygen therapy should not be limited solely to fat graft-related ischemia, but should be effective in the management of the more frequently encountered complications associated with polymethylmethacrylate fillers.


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Historia del Siglo XXI , Terapia por Inhalación de Oxígeno , Complicaciones Posoperatorias , Rejuvenecimiento , Jeringas , Trasplante Autólogo , Informes de Casos , Grasa Abdominal , Cara , Rellenos Dérmicos , Oxigenoterapia Hiperbárica , Necrosis , Oxígeno , Oxígeno/uso terapéutico , Terapia por Inhalación de Oxígeno/métodos , Complicaciones Posoperatorias/cirugía , Cirugía Plástica , Cirugía Plástica/métodos , Jeringas/efectos adversos , Trasplante Autólogo/métodos , Grasa Abdominal/trasplante , Cara/cirugía , Rellenos Dérmicos/efectos adversos , Rellenos Dérmicos/normas , Rellenos Dérmicos/uso terapéutico , Oxigenoterapia Hiperbárica/métodos , Necrosis/cirugía , Necrosis/complicaciones
2.
Rev. bras. cir. plást ; 30(3): 429-438, 2015. ilus, tab
Artículo en Inglés, Portugués | LILACS | ID: biblio-1152

RESUMEN

INTRODUÇÃO: O enxerto de gordura, atualmente, é usado amplamente na cirurgia plástica estética e reparadora como um preenchimento natural. Na cirurgia crânio-maxilofacial há uma diversidade de pacientes com deformidades congênitas e adquiridas que podem ser muito beneficiados com a lipoenxertia. MÉTODOS: Os pacientes foram submetidos à lipoenxertia para reconstrução e correção de defeitos da face no INTO em 2012 e 2013 utilizando uma técnica padronizada. Nossa avaliação foi clínica e subjetiva, levando em conta a opinião do paciente. Especificamente nos pacientes com enoftalmo tardio secundário à sequela de trauma, realizamos exoftalmometria com o exoftalmômetro de Hertel e tomografia no pré e no pós-operatório para avaliar objetivamente nossos resultados. RESULTADOS: Vinte e dois pacientes receberam tratamento. A maioria foi do gênero feminino (77%). O volume do gordura aplicado variou de 1 ml até 37 ml, com média de 15 ml por sessão. A quantidade de sessões variou de 1 a 4. A lipoenxertia foi usada como tratamento único em apenas 30% dos casos. Fizemos lipoenxertia retrobulbar variando de 6 a 10 ml o volume enxertado, sendo que em um paciente realizamos duas sessões. Houve um ganho de 3 a 7 mm de projeção do globo ocular. Na avaliação tomográfica constatamos também aumento da projeção ocular de 4 mm e 2,2 mm. O resultado clínico foi pobre. CONCLUSÃO: A lipoenxertia é um procedimento simples, barato e reprodutível que deve fazer parte do armamentário do cirurgião plástico e do cirurgião craniofacial. Pode ser uma alternativa nos difíceis casos de enoftalmo tardio.


INTRODUCTION: The fat graft is currently widely used in aesthetic plastic and reconstructive surgery as a natural filler. In cranio-maxillofacial surgery, fat grafting can be very beneficial for patients with various congenital and acquired deformities. METHODS: We included patients who had undergone fat grafting for reconstruction and correction of defects in the face during 2012 and 2013 by using a standard technique. Our assessment was both clinical and subjective, taking into account the patient's opinion. In patients with late enophthalmos secondary to trauma sequelae, we conducted exophthalmometry with an exophthalmometer (Hertel) and preoperative and postoperative CT to objectively evaluate our results. RESULTS: Twenty-two patients were treated. Most were female (77%). The volume of fat grafted varied from 1 ml to 37 ml, with a mean of 15 ml per session. The number of sessions ranged from 1 to 4. Fat grafting was used as a single treatment in only 30% of cases. We performed retrobulbar fat grafting ranging from 6 to 10 ml in volume; in one patient, the grafting was carried out over two sessions. There was a gain of 3 to 7 mm in projection of the eyeball. In tomographic evaluation, an increased eye projection of between 2.2 mm and 4 mm was found. However, the clinical outcome was poor. CONCLUSION: Fat grafting is a simple, inexpensive and reproducible procedure that should be part of the plastic and craniofacial surgeons' inventory. It may be an alternative in difficult cases of late enophthalmos.


Asunto(s)
Humanos , Masculino , Femenino , Niño , Adolescente , Adulto , Historia del Siglo XXI , Cráneo , Cirugía Plástica , Cirugía Plástica/métodos , Jeringas , Enoftalmia , Anomalías Craneofaciales , Trasplantes , Estudio de Evaluación , Cara , Grasas , Herida Quirúrgica/cirugía , Cráneo/cirugía , Jeringas/efectos adversos , Enoftalmia/cirugía , Enoftalmia/patología , Anomalías Craneofaciales/cirugía , Anomalías Craneofaciales/patología , Trasplantes/cirugía , Cara/cirugía , Grasas/uso terapéutico , Herida Quirúrgica , Herida Quirúrgica/terapia
3.
Salud pública Méx ; 53(supl.1): S19-S25, 2011. tab
Artículo en Español | LILACS | ID: lil-597119

RESUMEN

OBJETIVO: Medir la asociación entre el antecedente de procedimientos anestésicos y el riesgo de infección por el virus de la hepatitis C (VHC) en pacientes con cirugía previa. MATERIAL Y MÉTODOS: Diseño de casos y controles; los casos fueron pacientes con anticuerpo (anti-VHC) positivo confirmado por RIBA y/o RNA VHC y los controles fueron sujetos con el anti-VHC negativo. El riesgo de infección se estimó por razón de momios (RM) y análisis multivariado con regresión logística. RESULTADOS: Se incluyeron 362 sujetos, 211 casos y 151 controles; en 70 casos (33.2 por ciento), con cirugía previa, los procedimientos anestésicos se identificaron como único factor de riesgo significativo para la infección por el VHC (RM ajustada 2.44, IC 95 por ciento 1.44 - 4.11). CONCLUSIONES: Este es el primer estudio en México que demuestra asociación de riesgo significativa con el antecedente de procedimientos anestésicos por cirugía previa, en uno de cada tres enfermos con hepatitis C.


OBJECTIVE: Nosocomial transmission of hepatitis C virus (HCV) infection had been related with anesthesia procedures. The study aim was to measure the association between anesthesia procedures in cases with previous surgery and HCV infection. MATERIAL AND METHODS: In a case-control study were included subjects that attended to the Central Blood Bank of the West Medical National Center, Mexican Institute of the Social Security in Guadalajara, Jalisco between july 2005 and september 2007. Cases were patients with positive hepatitis C antibody (anti-HCV) confirmed by recombinant immunoblot assay (RIBA) and/or nucleic acid test (HCV RNA); the control group was blood donors with negative antibody. An exhaustive questionnaire about risk factors for hepatitis C, was applied. The risk of HCV infection was determined with the Odds Ratio (OR) and multivariate analysis was made by logistic regression. RESULTS: We included 362 subjects, 211 cases and 151 controls; in 70 (33.2 percent) cases were found significant association between the anesthesia procedures and HCV infection in patients with previous surgery (OR adjusted 2.44, CI 95 percent 1.44 - 4.11) CONCLUSION: This is the first study in México that demonstrate association between history of anesthesia procedures and HCV infection in cases with previous surgery.


Asunto(s)
Humanos , Anestesia , Infección Hospitalaria/transmisión , Contaminación de Equipos , Equipo Reutilizado , Hepatitis C/transmisión , Jeringas/virología , Anestesia/estadística & datos numéricos , Anestésicos Intravenosos , Anestésicos Locales , Transfusión Sanguínea/efectos adversos , Transfusión Sanguínea/estadística & datos numéricos , Estudios de Casos y Controles , Infección Hospitalaria/epidemiología , Contaminación de Medicamentos , Embalaje de Medicamentos , Hepatitis C/epidemiología , México/epidemiología , Encuestas y Cuestionarios , Factores de Riesgo , Cloruro de Sodio , Abuso de Sustancias por Vía Intravenosa/epidemiología , Jeringas/efectos adversos , Viremia/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA