Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
1.
Acta Academiae Medicinae Sinicae ; (6): 809-813, 2023.
Artículo en Chino | WPRIM | ID: wpr-1008134

RESUMEN

Objective To assess the effects of different application sequences of neodymium-doped yttrium aluminum garnet(Nd∶YAG)laser and the desensitizing toothpaste containing stannous fluoride on dentinal tubule occlusion.Methods Twelve intact third molars freshly extracted from human were selected and prepared into dentin slices with a thickness of 0.8 mm.Each dentin slice was subdivided into four small slices,three of which were etched with 6% citric acid and randomly assigned to the following three groups(n=12):(1)control group:no treatment;(2)Nd∶YAG+toothbrushing(TB)group:first irradiated with Nd∶YAG laser and then brushed with desensitizing toothpaste;(3)TB+Nd∶YAG group:first brushed with desensitizing toothpaste and then irradiated with Nd∶YAG laser.The Nd∶YAG laser irradiation were carried out at 1 W,15 pulses/s,and the pulse width of 150 μs for 10 s(for a total of 6 cycles).After the above treatment,the 12 dentin slices from the Nd∶YAG+TB and TB+Nd∶YAG groups were randomly assigned to four subgroups(n=3)and subjected to acid etching in the Coca-Cola solution for 0,5,10,and 15 min.A scanning electron microscope was used to observe and photograph the dentin slices in each group,and eight single-blinded examiners scored the slices according to uniform criteria.The analysis of variance was carried out to compared the scores between groups.Results Before acid etching,the dentin tubule occlusion scores of the Nd∶YAG+TB and TB+Nd∶YAG groups were(4.83±0.09) scores and(3.85±0.66) scores,respectively,which had no significant difference between each other(P=0.0590)and were higher than that[(0.10±0.07)scores]of the control group(both P<0.0001).The dentin tubule occlusion scores of the Nd∶YAG+TB group after acid etching for 5,10,and 15 min were(4.33±0.60)scores,(4.27±0.24)scores,and(3.63±0.07)scores,respectively,which were not significantly different from those[(4.04±0.10)scores,(3.76±0.59)scores,and(3.17±0.29)scores,respectively]of the TB+Nd∶YAG group(all P>0.05).In the Nd∶YAG+TB subgroup,the dentin tubule occlusion score after acid etching for 15 min was significantly lower than that before acid etching(P=0.0011).In the TB+Nd∶YAG group,there was no statistically significant difference in the score between before and after acid etching(P>0.05).Conclusions Nd∶YAG laser irradiation with appropriate parameters combined with the use of desensitizing toothpaste could produce an excellent occluding effect on dentinal tubules regardless of the sequence.However,brushing with desensitizing toothpaste followed by Nd∶YAG laser irradiation produced more consistent dentin sealing after acid etching.


Asunto(s)
Humanos , Dentina , Sensibilidad de la Dentina/terapia , Láseres de Estado Sólido/uso terapéutico , Microscopía Electrónica de Rastreo , Pastas de Dientes/farmacología
2.
Asian Journal of Andrology ; (6): 281-285, 2023.
Artículo en Inglés | WPRIM | ID: wpr-970995

RESUMEN

The aim of this study was to explore the optimal timing of holmium laser enucleation of the prostate (HoLEP) in patients presenting benign prostatic hyperplasia (BPH) with lower urinary tract symptoms (LUTS). A retrospective analysis was conducted based on the perioperative and postoperative outcome data of 1212 patients who underwent HoLEP in Shanghai Ninth People's Hospital (Shanghai, China) between January 2009 and December 2018. According to the preoperative International Prostate Symptom Score (IPSS), all patients whom we analyzed were divided into Group A (IPSS of 8-18) and Group B (IPSS of 19-35). Peri- and postoperative outcome data were obtained during the 1-year follow-up. IPSS changes were the main postoperative outcomes. The postoperative IPSS, quality of life, peak urinary flow rate, postvoid residual, and overactive bladder symptom score (OABSS) improved significantly. The IPSS improved further in the group with severe LUTS symptoms, but the postoperative IPSS was still higher than that in the moderate LUTS group. OABSSs showing moderate and severe cases after follow-up were more frequent in Group B (9.1%) than in Group A (5.2%) (P < 0.05). There were no significant intergroup differences in the intraoperative American Society of Anesthesiologists or hospitalization expense scores, and the medication costs, as well as the total costs, were significantly higher in Group B. In this retrospective study, HoLEP was an effective treatment for symptomatic BPH. For patients with LUTS, earlier surgery in patients with moderate severity may result in a marginally better 12-month IPSS than that in men with severe symptoms.


Asunto(s)
Masculino , Humanos , Estudios Retrospectivos , Hiperplasia Prostática/cirugía , Estudios de Seguimiento , Holmio , Calidad de Vida , China , Resultado del Tratamiento , Síntomas del Sistema Urinario Inferior/cirugía , Terapia por Láser , Láseres de Estado Sólido/uso terapéutico
3.
Int. braz. j. urol ; 48(2): 328-335, March-Apr. 2022. tab
Artículo en Inglés | LILACS | ID: biblio-1364937

RESUMEN

ABSTRACT Objectives: To compare thulium laser enucleation of prostate (ThuLEP) versus laparoscopic trans-vesical simple prostatectomy (LSP) in the treatment of benign prostatic hyperplasia (BPH). Materials and Methods: Data of patients who underwent surgery for "large" BPH (>80mL) at three Institutions were collected and analyzed. Two institutions performed ThuLEP only; the third institution performed LSP only. Preoperative (indwelling catheter status, prostate volume (PVol), hemoglobin (Hb), Qmax, post-voiding residual volume (PVR), IPSS, QoL, IIEF-5) and perioperative data (operative time, enucleated adenoma, catheterization time, length of stay, Hb-drop, complications) were compared. Functional (Qmax, PVR, %ΔQmax) and patient-reported outcomes (IPSS, QoL, IIEF-5, %ΔIPSS, %ΔQoL) were compared at last follow-up. Results: 80 and 115 patients underwent LSP and ThuLEP, respectively. At baseline, median PVol was 130 versus 120mL, p <0.001; Qmax 9.6 vs. 7.1mL/s, p=0.005; IPSS 21 versus 25, p <0.001. Groups were comparable in terms of intraoperative complications (1 during LSP vs. 3 during ThuLEP) and transfusions (1 per group). Differences in terms of operative time (156 vs. 92 minutes, p <0.001), Hb-drop (-2.5 vs. −0.9g/dL, p <0.001), catheterization time (5 vs. 2 days, p <0.001) and postoperative complications (13.8% vs. 0, p <0.001) favored ThuLEP. At median follow-up of 40 months after LSP versus 30 after ThuLEP (p <0.001), Qmax improved by 226% vs. 205% (p=0.5), IPSS decreased by 88% versus 85% (p=0.9), QoL decreased by 80% with IIEF-5 remaining almost unmodified for both the approaches. Conclusions: Our analysis showed that LSP and ThuLEP are comparable in relieving from BPO and improving the patient-reported outcomes. Invasiveness of LSP is more significant.


Asunto(s)
Humanos , Masculino , Hiperplasia Prostática/cirugía , Hiperplasia Prostática/complicaciones , Laparoscopía , Terapia por Láser , Láseres de Estado Sólido/uso terapéutico , Próstata/cirugía , Prostatectomía , Calidad de Vida , Tulio/uso terapéutico , Resultado del Tratamiento
4.
Int. braz. j. urol ; 48(2): 371-372, March-Apr. 2022.
Artículo en Inglés | LILACS | ID: biblio-1364945

RESUMEN

ABSTRACT Introduction: Tissue transfer has been used in urethral reconstruction for decades, and several grafts have been described (1, 2). The ideal graft would have optimal tissue characteristics and lead to minimal morbidity at the donor site. Urethroplasty using bladder mucosa was first described by Memmelaar in 1947 (3). The main limitation in using bladder mucosal grafts has been the invasiveness of open harvesting (4). We describe an endoscopic technique using Holmium: YAG laser to harvest bladder mucosal graft for substitution urethroplasty. Methodology: A 33-year-old male with no history of urethral instrumentation, trauma, or infection presented with obstructive lower urinary tract symptoms. On retrograde urethrogram a 6cm bulbar urethral stricture was identified. Several options were discussed, and the patient opted for a one-sided onlay dorsal urethroplasty (5) using a bladder mucosal graft. Equipment used to harvest the graft included an 18.5Fr continuous flow laser endoscope with a Kuntz working element (RZ) and a 60W Holmium Laser (Quanta) with 550μm laser fiber. The procedure was started by making a perineal incision, urethral mobilization and incision of the stricture segment. The laser endoscope was then introduced via the perineum. Settings of 0.5J, 30 Hz, and long pulse were used and a 7 x 2.5cm graft was harvested from the posterior bladder wall. Hemostasis of the harvest site was performed. The bladder mucosal graft was thinned in similar fashion to a buccal mucosal graft and sutured as per previously described techniques. Conclusion: Endoscopic Holmium Laser harvesting of bladder mucosal graft is feasible and may allow this graft to become an alternative to buccal mucosa. Further studies are required to define its role in urethral reconstruction.


Asunto(s)
Humanos , Masculino , Adulto , Estrechez Uretral/cirugía , Láseres de Estado Sólido/uso terapéutico , Uretra/cirugía , Vejiga Urinaria/cirugía , Mucosa Bucal/trasplante
5.
Int. braz. j. urol ; 48(1): 200-201, Jan.-Feb. 2022.
Artículo en Inglés | LILACS | ID: biblio-1356299

RESUMEN

ABSTRACT Purpose: The expansion of technology is leading to a paradigm shift in several urological fields (1, 2). In particular, the adoption of lasers within the surgical treatment of patients with benign prostatic hyperplasia (BPH) is considered one of the most relevant innovations (3-5). In this video, we aimed to report our experience with holmium laser for the ablation of the prostate (HoLAP) in patients with obstructive lower urinary tract symptoms (LUTS) due to BPH. Materials and Methods: From 2018 to 2020, 10 patients with obstructive LUTS secondary to BPH were treated at our Institution with HoLAP (120W Holmium laser Lumenis® with Moses® technology). Main inclusion criteria were: 1) International Prostate Symptom Score ≥12; 2) prostate volume ≤65mL, 3) maximal flow rate (Qmax) ≤15ml/s at preoperative non-invasive uroflowmetry. Results: Mean patient age was 65 (range: 59-72) years. Preoperative mean prostate volume was 50 (range: 35-65) mL. Mean operative time was 66 (range: 45-85) minutes with a mean laser time/operative time ratio of 0.51 (range: 0.44-0.60). Voiding symptoms, Qmax and post voiding residual were significantly improved after 3 and 12 months (all p <0.05). No postoperative urinary incontinence was detected. Conclusions: The present findings suggest that HoLAP is a slightly time-spending procedure, thus its use should be limited to prostate volume <70-80mL. However, no postoperative complications were recorded at all. This technique showed to be a safe option in patients with low-intermediate prostate volume, also in patients whose antiaggregant/anticoagulant therapy is maintained.


Asunto(s)
Humanos , Masculino , Hiperplasia Prostática/cirugía , Resección Transuretral de la Próstata , Terapia por Láser , Láseres de Estado Sólido/uso terapéutico , Próstata/cirugía , Prostatectomía , Tecnología , Holmio
6.
Rev. bras. oftalmol ; 81: e0006, 2022. tab, graf
Artículo en Portugués | LILACS | ID: biblio-1360917

RESUMEN

RESUMO Objetivo: Identificar se há mudança refracional significativa após realização de capsulotomia posterior com laser Nd:YAG em olhos pseudofácicos. Métodos: Estudo retrospectivo com análise de prontuários de pacientes atendidos em um hospital com diagnóstico de opacificação de cápsula posterior do cristalino tratada com capsulotomia posterior com laser Nd:YAG no período de outubro de 2019 a março de 2021. A comparação entre a refração antes e após o procedimento foi realizada calculando-se o equivalente esférico. Também foi avaliada a mudança da acuidade visual, aferida por LogMAR. Resultados: Foram analisados 90 prontuários, totalizando 140 olhos, de pacientes submetidos à capsulotomia posterior com laser Nd:YAG. O equivalente esférico médio pré-procedimento foi de -0,07±0,89D, mínimo de -3,0D e máximo de +2,5D, mediana (intervalo interquartil) de 0,0D (-0,50D a +0,375D). A média pós-procedimento foi de -0,18±0,86D, mínimo de -3,5D e máximo de +2,25D, mediana (intervalo interquartil) de -0,125D (-0,50D a 0,0D). com p<0,0082. Dos 140 olhos, 66 sofreram miopização e 37 hipermetropização. A média de alteração do equivalente esférico geral foi de -0,12±0,51D, mínimo de -2,50D e máximo de +1,25D, mediana (intervalo interquartil) de 0,0D (-0,375D a +0,125D). Ao se comparar a diferença entre o equivalente esférico antes e após o procedimento do grupo de olhos que sofreu miopização (n=66) ou hipermetropização (n=37), separadamente, ambos obtiveram p<0,0001. Ao se compararem todos os olhos que sofreram alguma alteração refracional (n=103), foi encontrado p=0,008. A acuidade visual média pré-procedimento foi de 0,23±0,32, mínimo de 0,0 e máximo de 2,3. Pós-procedimento, a média foi de 0,06±0,13, mínimo de -0,12 e máximo de 0,7, com p<0,0001. Conclusão: A capsulotomia posterior com laser Nd:YAG gerou melhora significativa da acuidade visual nos pacientes do estudo, porém também gerou alteração refracional significativa após o procedimento, tanto para miopização (a mais frequente), quanto para hipermetropização.


ABSTRACT Objective: To identify if there is a significant change on refraction after Nd:YAG laser posterior capsulotomy in pseudophakic eyes. Methods: A retrospective study with analysis of medical records of patients treated at a hospital, with diagnosis of opacification of posterior lens capsule treated with Nd:YAG laser posterior capsulotomy, from October 2019 to March 2021. The comparison of refraction before and after the procedure was performed by calculating the spherical equivalent. Changes in visual acuity (VA), measured by LogMAR, were also evaluated. Results: A total of 90 medical records (140 eyes) of patients submitted to Nd:YAG laser posterior capsulotomy were analysed. The mean pre-procedure spherical equivalent was -0.07±0.89D, minimum of -3.0D and maximum of +2.5D, median (interquartile range) of 0.0D (-0.50D to +0.375D). The post-procedure mean was -0.18±0.86D, minimum of -3.5D and maximum of +2.25D, median (interquartile range) of -0.125D (-0.50D to 0.0D), with p <0.0082. Of the 140 eyes, 66 underwent myopia and 37 hyperopia, the mean change in the general spherical equivalent was -0.12±0.51D, minimum -2.50D and maximum +1.25D, median (interquartile range) of 0.0D (-0.375D to +0.125D). When comparing the difference between the spherical equivalent before and after the procedure of the group of eyes that underwent myopia (n=66) or hyperopia (n=37), separately, both obtained p<0.0001. When comparing all eyes that suffered any change on refraction (n=103), the p value was 0.008. The mean pre-procedure visual acuity was 0.23±0.32, minimum of 0.0 and maximum of 2.3. After the procedure, the mean was 0.06±0.13, minimum of -0.12 and maximum of 0.7, p<0.0001. Conclusion: Nd:YAG laser posterior capsulotomy significantly improved visual acuity of patients in this study; however, it also led to a significant change on refraction after the procedure, both for myopization, which was more frequent, and for hyperopization.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Refracción Ocular , Láseres de Estado Sólido/uso terapéutico , Capsulotomía Posterior/efectos adversos , Capsulotomía Posterior/métodos , Extracción de Catarata/efectos adversos , Registros Médicos , Estudios Retrospectivos , Facoemulsificación/efectos adversos , Seudofaquia/cirugía , Terapia por Láser/métodos , Opacificación Capsular/cirugía , Opacificación Capsular/etiología
7.
São Paulo; s.n; Versão corr; 2022. 66 p. ilus, graf.
Tesis en Portugués | LILACS, BBO | ID: biblio-1416801

RESUMEN

O objetivo deste estudo clínico, controlado, randomizado, cego e prospectivo foi de avaliar a efetividade clínica de restaurações em lesões não cariosas (cavidades Classe V) realizadas em superfícies dentais pré-tratadas ou não com laser de Er:YAG e utilizando dois sistemas adesivos autocondicionantes. Este estudo foi realizado com um total de 91 lesões e divididas em 4 grupos (n = 23) :G1(FL): Sem pré-tratamento e utilizando o adesiso FL-Bond II/Shofu; G2 (CF): sem pré-tratamento e utilizando o adesivo Clearfil SE Bond 2/Kuraray Noritake; G3 (Laser + FL): pré-tratamento associado ao uso do FL-Bond II/Shofu e G4 (Laser + CF): pré-tratamento associado ao uso do Clearfil SE Bond 2/Kuraray Noritake Os dentes avaliados foram os pré-molares de ambas as arcadas. A avaliação foi feita imediatamente após o tratamento e ao longo do tempo, em 3, 6 e 12 meses após a finalização da restauração. Para a avaliação da sensibilidade foi considerado a EVA (Escala Visual Analógica) e para a qualidade da restauração o método do USPHS modificado, considerando a avaliação de perda de retenção, integridade marginal, pigmentação marginal, presença de lesão de cárie em margem de restauração, vitalidade pulpar e sensibilidade pós-operatória. Os dados foram registrados em tabelas de frequência, e os escores transformados em postos para a aplicação do teste ANOVA. A significância estatística foi considerada para valores de p<0,05. Para os resultados da avaliação de sensibilidade houve uma diferença estatística significante da sensibilidade ao longo do tempo (p<0,001), sendo que essa diferença se deu a partir da avaliação T1 (48 horas) em todos os grupos. Em relação aos critérios avaliados no USPHS, foram encontrados variações estatísticas em alguns tópicos: Pigmentação marginal - G1 (FL) (p=0,041) e G2 ( Laser + FL) (p=0,009) e Integridade marginal G1(FL)( p=0,036). Os demais grupos e critérios não apresentaram variações estatísticas significantes.Pré-tratamentos com laser Er:YAG podem ser uma alternativa viável em restaurações adesivas do tipo classe V; no entanto, nenhum efeito sinérgico de ambos os tratamentos combinados foi observado.


The objective of this clinical, controlled, randomized, blinded and prospective study was to evaluate the clinical effectiveness of restorations in non-carious lesions (Class V cavities) performed on dental surfaces pre-treated or not with Er:YAG laser and using two adhesive systems self-conditioning. This study was carried out with a total of 91 lesions and divided into 4 groups (n = 23) :G1(FL): No pre-treatment and using the FL-Bond II/Shofu adhesive; G2 (CF): without pre-treatment and using Clearfil SE Bond 2/Kuraray Noritake adhesive; G3 (Laser + FL): pre-treatment associated with the use of FL-Bond II/Shofu and G4 (Laser + CF): pre-treatment associated with the use of Clearfil SE Bond 2/Kuraray Noritake The teeth evaluated were the premolars of both arcades. Assessment was performed immediately after treatment and over time, at 3, 6, and 12 months after completion of the restoration. The VAS (Visual Analogue Scale) was used for the sensitivity assessment and the modified USPHS method for the quality of the restoration, considering the assessment of loss of retention, marginal integrity, marginal pigmentation, presence of caries in the restoration margin. , pulp vitality and postoperative sensitivity. Data were recorded in frequency tables, and the scores were transformed into ranks for the application of the ANOVA test. Statistical significance was considered for values of p<0.05. For the results of the sensitivity evaluation, there was a statistically significant difference in sensitivity over time (p<0.001), and this difference occurred from the T1 evaluation (48 hours) in all groups. Regarding the criteria evaluated at the USPHS, statistical variations were found in some topics: Marginal pigmentation - G1 (FL) (p=0.041) and G2 (Laser + FL) (p=0.009) and Marginal integrity - G1(FL)( p =0.036). The other groups and criteria did not present significant statistical variations. Pretreatments with Er:YAG laser can be a viable alternative in class V adhesive restorations; however, no synergistic effect of both treatments combined was observed.


Asunto(s)
Humanos , Adolescente , Adulto , Persona de Mediana Edad , Adulto Joven , Enfermedades Dentales/terapia , Recubrimientos Dentinarios/uso terapéutico , Restauración Dental Permanente/métodos , Láseres de Estado Sólido/uso terapéutico , Método Simple Ciego , Estudios Prospectivos , Estudios de Seguimiento , Resultado del Tratamiento , Sensibilidad de la Dentina
8.
Rev. cuba. oftalmol ; 34(3): e1051, 2021. graf
Artículo en Español | LILACS, CUMED | ID: biblio-1352035

RESUMEN

El lupus eritematoso sistémico es una enfermedad autoinmune, de curso crónico con afectación multisistémica. Las manifestaciones oculares del lupus eritematoso sistémico pueden afectar cualquier estructura del ojo. La formación de catarata y la aparición de la diabetes secundaria asociada con el tratamiento esteroideo prolongado es frecuente en estos pacientes. Se presenta el caso de una paciente femenina de 69 años, con antecedentes de lupus eritematoso sistémico de más de 20 años de evolución, tratada con 5 mg diarios de prednisona oral en dosis de mantenimiento. Refiere, además, diabetes mellitus tipo 2 controlada de más de 10 años de evolución. Asiste a la consulta de Oftalmología por disminución de la visión y se diagnostica catarata en el ojo derecho. Se realiza facoemulsificación con implante de lente intraocular plegable, previa profilaxis para la endoftalmitis. La catarata asociada a la diabetes secundaria en los pacientes con lupus eritematoso sistémico justifica el uso de profilaxis antinflamatoria con esteroides tópicos y sistémicos para asegurar una mínima inflamación posoperatoria y mejorar el pronóstico visual(AU)


Systemic lupus erythematosus is a chronic autoimmune disease of multisystemic involvement. Ocular manifestations of systemic lupus erythematosus may present in any structure of the eye. Cataract formation and the appearance of secondary diabetes associated to prolonged steroid therapy are common in these patients. A case is presented of a female 69-year-old patient with a history of systemic lupus erythematosus of more than 20 years' evolution, treated with 5 mg daily of oral prednisone at maintenance doses. The patient also reports controlled diabetes mellitus type 2 of more than ten years' evolution. Her main concern in attending Ophthalmology consultation is vision reduction. Cataract is diagnosed in her right eye. The treatment indicated is phacoemulsification with foldable intraocular lens implantation following prophylaxis for endophthalmitis. Cataract associated to secondary diabetes in patients with systemic lupus erythematosus justifies the use of anti-inflammatory prophylaxis with topical and systemic steroids to ensure minimum postoperative inflammation and improve visual prognosis(AU)


Asunto(s)
Humanos , Femenino , Anciano , Catarata/diagnóstico , Endoftalmitis/complicaciones , Facoemulsificación/métodos , Implantación de Lentes Intraoculares/métodos , Diabetes Mellitus Tipo 2/etiología , Lupus Eritematoso Sistémico/diagnóstico , Láseres de Estado Sólido/uso terapéutico , Informe de Investigación
9.
Braz. oral res. (Online) ; 35: e29, 2021. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1153613

RESUMEN

Abstract This study evaluated how Er,Cr:YSGG laser, associated or not with 5% fluoride varnish, influences the surface roughness and volume loss of bovine root dentin submitted to erosive and/or abrasive wear. One hundred and twenty dentin specimens were divided into the groups: without preventive treatment (WPT), 5% fluoride varnish (FV); Er,Cr:YSGG laser irradiation (L), and varnish combined with laser (FV + L). The specimens (n = 10) were subdivided into: 1 = erosion (E); 2 = abrasion (A); and 3 = erosion followed by abrasion (E + A). The erosive solution used was a soft-drink (pH = 2.42 at 4ºC) applied in 5-min cycles twice a day for 10d. Abrasive wear involved brushing for 60s with an electric brush (1,600-oscillations/s) at a load of 2.0N. Surface roughness and volume loss were evaluated using a laser scanning confocal microscope. Roughness data were submitted to one-way ANOVA and Tukey post-hoc test. For volume loss, the Kruskal-Wallis and Dunn's post-hoc tests were used (α = 5%). The lowest values of roughness were found in the control areas of all subgroups (p > 0.05). In the experimental area, the [(WPT) + (E+A)] subgroup had a significantly higher roughness (5.712 ± 0.163 μm 2 ) than the other subgroups (p < 0.05). The L and (FV + L) groups had statistically similar roughness, regardless of the type of wear. The (FV + L) group had the lowest volume loss, regardless of the type of wear performed: [(FV + L) + (E)] = 7.5%, [(FV + L) + (A) = 7.3%, and [(FV + L) + (E + A)] = 8.1%. The subgroup [(WPT) + (E + A)] had the highest volume loss (52.3%). The proposed treatments were effective in controlling dentin roughness. Laser irradiation can be an effective method to increase root dentin resistance after challenges and limit problems related to non-carious lesions.


Asunto(s)
Animales , Bovinos , Erosión de los Dientes/etiología , Láseres de Estado Sólido/uso terapéutico , Raíz del Diente , Cepillado Dental , Dentina , Fluoruros
10.
J. appl. oral sci ; 29: e20200266, 2021. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1180799

RESUMEN

Abstract Objectives We analyzed the effects of the Er:YAG laser used with different parameters on dentinal tubule (DT) occlusion, intrapulpal temperature and pulp tissue morphology in order to determine the optimal parameters for treating dentin hypersensitivity. Methodology Dentin specimens prepared from 36 extracted human third molars were randomized into six groups according to the treatment method (n=6 each): control (A); Gluma desensitizer (B); and Er:YAG laser treatment at 0.5 W , 167 J/cm2 (50 mJ, 10 Hz) (C), 1 W , 334 J/cm2 (50 mJ, 20 Hz) (D), 2 W , 668 J/cm2 (100 mJ, 20 Hz) (E), and 4 W and 1336 J/cm2 (200 mJ, 20 Hz) (F). Treatment-induced morphological changes of the dentin surfaces were assessed using scanning electron microscopy (SEM) to find parameters showing optimal dentin tubule occluding efficacy. To further verify the safety of these parameters (0.5 W, 167 J/cm2), intrapulpal temperature changes were recorded during laser irradiation, and morphological alterations of the dental pulp tissue were observed with an upright microscope. Results Er:YAG laser irradiation at 0.5 W (167 J/cm2) were found to be superior in DT occlusion, with an exposure rate significantly lower than those in the other groups (P<0.05). Intrapulpal temperature changes induced by Er:YAG laser irradiation at 0.5 W (167 J/cm2) with (G) and without (H) water and air cooling were demonstrated to be below the threshold. Also, no significant morphological alterations of the pulp and odontoblasts were observed after irradiation. Conclusion Therefore, 0.5 W (167 J/cm2) is a suitable parameter for Er:YAG laser to occlude DTs, and it is safe to the pulp tissue.


Asunto(s)
Humanos , Láseres de Estado Sólido/uso terapéutico , Microscopía Electrónica de Rastreo , Oclusión Dental , Dentina
11.
J. appl. oral sci ; 29: e20200736, 2021. graf
Artículo en Inglés | LILACS | ID: biblio-1180797

RESUMEN

Abstract Objective To evaluate the efficacy of Nd:YAG laser associated with calcium-phosphate desensitizing pastes on dentin permeability and tubule occlusion after erosive/abrasive challenges. Methodology Dentin specimens were exposed to 17% ethylene diamine tetra-acetic acid (EDTA) solution for 5 min and randomly allocated into five groups: G1, control (no treatment); G2, Nd:YAG laser (1 W, 10 Hz, 100 mJ, 85 J/cm2); G3, Laser + TeethmateTM Desensitizer; G4, Laser + Desensibilize Nano P; and G5, Laser+Nupro®. Specimens underwent a 5-day erosion-abrasion cycling. Hydraulic conductance was measured post-EDTA, post-treatment, and post-cycling. Post-treatment and post-cycling permeability (%Lp) was calculated based on post-EDTA measurements, considered 100%. Open dentin tubules (ODT) were calculated at the abovementioned experimental moments using scanning electron microscopy and ImageJ software (n=10). Data were analyzed using two-way repeated measures ANOVA and Tukey's test (α=0.05). Results G1 presented the highest %Lp post-treatment of all groups (p<0.05), without significantly differences among them. At post-cycling, %Lp significantly decreased in G1, showed no significant differences from post-treatment in G3 and G4, and increased in G2 and G5, without significant differences from G1 (p>0.05). We found no significant differences in ODT among groups (p>0.05) post-EDTA. At post-treatment, treated groups did not differ from each other, but presented lower ODT than G1 (p<0.001). As for post-cycling, we verified no differences among groups (p>0.05), although ODT was significantly lower for all groups when compared to post-EDTA values (p<0.001). Conclusion All treatments effectively reduced dentin permeability and promoted tubule occlusion after application. Combining Nd YAG laser with calcium-phosphate pastes did not improve the laser effect. After erosive-abrasive challenges, treatments presented no differences when compared to the control.


Asunto(s)
Láseres de Estado Sólido/uso terapéutico , Desensibilizantes Dentinarios , Microscopía Electrónica de Rastreo , Calcio/farmacología , Dentina , Permeabilidad de la Dentina
12.
Int. j. med. surg. sci. (Print) ; 7(4): 1-20, dic. 2020. tab, ilus
Artículo en Español | LILACS | ID: biblio-1151709

RESUMEN

El propósito de este artículo es mejorar nuestro conocimiento sobre las estructuras y función de los diferentes elementos presentes en la boca del recién nacido, ya que en ocasiones los odontólogos no recuerdan la importancia de la boca en el desarrollo general del lactante y la necesidad de una intervención temprana con láseres para ayudarles a obtener un buen estado de su sistema oral. Realizamos una exploración clínica integral del paciente con el fin de realizar un diagnóstico más preciso. Cuando la cirugía sea necesaria, recomendamos utilizar láseres de Erbio siempre que sea posible (láser de 2780nm Er, Cr: YSGG o un Er: YAG de 2940nm), ya que es una opción rápida y eficaz para tratar estas lesiones orales, especialmente los frenillos labiales o linguales que pueden poner en riesgo el acto de amamantar; Asimismo podemos utilizar láseres de diodo (810nm, 940nm, 980 nm o un láser Nd: YAG de 1064nm o de CO2 10.600- 9600 nm) con sus gafas de seguridad específicas. Estos sistemas láser utilizados por un profesional certificado, en colaboración con un personal debidamente entrenado, son un factor muy importante durante la cirugía. Al tener un conocimiento adecuado de las estructuras orales y sus patologías, podemos diagnosticar si esos trastornos deben tratarse quirúrgicamente y, de ser así, cómo proceder con los sistemas láser, ya que son procedimientos mínimamente invasivos; o si debiésemos recomendar a los padres que visiten a un terapeuta miofuncional para ayudar a recuperar la función normal. La comprensión de las estructuras orales de los recién nacidos es muy importante para promover el desarrollo del crecimiento craneofacial y para brindar un servicio importante a las madres, dándoles a sus bebés un buen comienzo en la vida desde una etapa muy temprana. Necesitamos mejorar la colaboración entre profesionales de diferentes disciplinas con el fin de mejorar nuestro conocimiento.


The purpose of this article is to improve our knowledge about the structures and function of the different elements present in the mouth of newborns since dentists sometimes do not remember the importance of the mouth in the general development of infants and the need for an early intervention with lasers to help them obtain a good state of their Oral System. We performed a comprehensive clinical exploration of the patient in order to make a more accurate diagnosis. When surgery is necessary, we recommend to use erbium lasers when possible (2780nm Er, Cr: YSGG laser or a 2940nm Er: YAG), as they are a quick and effective option to treat these oral lesions, especially lip or tongue ties which can risk the act of breastfeeding; moreover, we can also use diode lasers (810nm, 940nm, 980nm or a 1064nm Nd:YAG laser or CO2 10.600-9600 nm.) al lof them with their specifical safety goggles. These laser systems used by a certified professional, in collaboration with a properly trained staff, are a very important factor during the surgery.By having proper knowledge of the oral structures and their pathologies, we are able to diagnose whether those disorders should be surgically treated and if so, how to proceed with laser systems as they are minimally invasive procedures; or if we should recommend parents to visit a myofunctional therapist in order to help recover the normal function.The understanding of oral structures of newborns is very important in order to improve the development of craniofacial growth and provide an important service to mothers by giving their babies a right start in life from a very early stage. We need to improve collaboration between professionals from different disciplines in order to enhance our knowledge.


Asunto(s)
Humanos , Recién Nacido , Láseres de Semiconductores/uso terapéutico , Láseres de Estado Sólido/uso terapéutico , Boca/cirugía , Procedimientos Quirúrgicos Orales , Anquiloglosia/cirugía , Frenillo Labial/cirugía
13.
Rev. cuba. estomatol ; 57(3): e3142, jul.-set. 2020. graf
Artículo en Español | LILACS, CUMED | ID: biblio-1126529

RESUMEN

RESUMEN Introducción: Al realizar una intervención quirúrgica, el instrumento de corte utilizado cobra especial importancia, pues el mismo está vinculado a los signos y síntomas intra- y posoperatorios y al tiempo de reparación de los tejidos. En respuesta a esto, con el tiempo se han propuesto nuevos instrumentos, particularmente la tecnología láser ha venido sufriendo un avance rápido y significativo y en la actualidad se utiliza para un sinnúmero de tratamientos odontológicos. Al láser se le han atribuido diferentes ventajas en la cirugía estética periodontal: desde facilitar el proceso de hemostasia, hasta la estimulación del proceso de reparación tisular. Sin embargo, es pertinente realizar estudios que demuestren a nivel histológico los cambios que generan en la mucosa oral y obtener información que permita conocer de qué manera influye en el proceso de reparación del tejido. Objetivo: Describir los hallazgos histológicos asociados al corte con láser de Er, Cr: YSGG de 2780 nm en muestras de encía obtenidas mediante gingivectomía. Presentación del caso: Paciente femenina, de 21 años, sistémicamente sana. Asistió a la consulta por presentar por inconformidad estética al sonreír. Se diagnosticó con exposición de banda de encía queratinizada mayor que 4 mm. Como parte del plan de tratamiento se indicó gingivectomía con láser de Er, Cr: YSGG (2780 nm) (Waterlase®, BIOLASE®), el procedimiento se realizó solo bajo anestesia tópica. Se tomaron muestras histológicas de tejido gingival para análisis histológico. Conclusiones: El láser Er, Cr: YSGG (2780 nm) preservó la morfología de los fibroblastos después del corte, no hubo evidencia de carbonización, ni profundización de la lesión térmica en el tejido. Este instrumento fue una herramienta de gran utilidad para la ejecución del tratamiento en este caso. Tuvo ventajas importantes como la ausencia de dolor posoperatorio, buena hemostasia y la reparación epitelial casi completa en tan solo 4 días(AU)


ABSTRACT Introduction: When performing a surgical intervention, the cutting instrument used is especially important, since it is associated with intraoperative and postoperative signs and symptoms and to the time of tissue repair. In response to this, new instruments have been proposed over time, particularly laser technology has been undergoing rapid and significant advancement and is currently used for countless dental treatments. Laser has been attributed different advantages in periodontal cosmetic surgery: from facilitating the hemostasis process, to stimulating the tissue repair process. However, it is pertinent to carry out studies that prove, at histological level, the changes in the oral mucosa and obtain information that allows us to know how it influences the tissue repair process. Objective: To describe the histological findings associated with the Er, Cr: YSGG (2780 nm) laser cut in gum samples obtained by gingivectomy. Case presentation: Female patient, 21 years old, systemically healthy. She attended the consultation for presenting aesthetic dissatisfaction when smiling. She was diagnosed with exposure of keratinized gum band greater than 4 mm. As part of the treatment plan, Er, Cr: YSGG (Waterlase®, BIOLASE®, 2780 nm) laser gingivectomy was indicated. The procedure was performed only under topical anesthesia. Histological samples of gingival tissue were taken for histological analysis. Conclusions: The Er, Cr: YSGG (2780 nm) laser preserved the morphology of the fibroblasts after the cut. There was no evidence of carbonization or deepening of the thermal injury in the tissue. In this case, this instrument was a very useful tool for the performance of the treatment. It had important advantages, such as the absence of postoperative pain, good hemostasis, and almost complete epithelial repair in just four days(AU)


Asunto(s)
Humanos , Femenino , Adulto Joven , Gingivectomía/efectos adversos , Estética Dental , Láseres de Estado Sólido/uso terapéutico
14.
National Journal of Andrology ; (12): 888-894, 2020.
Artículo en Chino | WPRIM | ID: wpr-880287

RESUMEN

Objective@#To investigate the advantages and disadvantages of point electro-cauterization (PEC) and holmium laser cauterization (HLC) in the treatment of post-ejaculation hematuria.@*METHODS@#From January 2015 to December 2018, 73 patients with post-ejaculation hematuria, aged 24-63 (36.8 ± 4.2) years, underwent PEC (n = 35) or HLC (n = 38) after failure to respond to 3 months of conservative treatment. We compared the hospital days, total hospitalization expenses, maximum urinary flow rate (Qmax), average urinary flow rate (Qavg), Hamilton Anxiety Rating Scale (HAMA) score, postoperative duration of hematuria, and recurrence rate at 3 and 6 months after surgery.@*RESULTS@#All the patients experienced first ejaculation but no post-ejaculation hematuria at 1 month after operation. The recurrence rates were lower in the PEC than in the HLC group at 3 months (5.71% vs 2.63%, P > 0.05) and 6 months postoperatively (8.57% vs 5.26%, P > 0.05). Compared with the baseline, the Qmax was decreased from (18.56 ± 2.53) ml/s to (13.68 ± 3.31) ml/s (P < 0.05) and the Qavg from (14.35 ± 2.26) ml/s to (9.69±1.84) ml/s in the PEC group at 1 month after surgery (P < 0.01), but neither showed any statistically significant difference in the HLC group. Mild to moderate anxiety was prevalent in the patients preoperatively, particularly in those without job or regular income and those with a long disease course or frequent onset, the severity of which was not correlated with age, education or marital status. The HAMA score was decreased from18.65 ± 4.33 before to 12.35 ± 3.63 after surgery in the PEC group (P < 0.01), and from 16.88 ± 2.11 to 6.87 ± 4.36 in the HLC group (P < 0.01). The mean hospital stay was significantly longer in the former than in the latter group ([5.2 + 1.3] vs [3.4 ± 0.5] d, P < 0.01), while the total cost markedly lower ([6.35 ± 1.20] vs [12.72 ± 2.15] thousand RMB ¥, P < 0.05).@*CONCLUSIONS@#Both PEC and HLC are safe and effective for the treatment of post-ejaculation hematuria, with no significant difference in the recurrence rate at 3 and 6 months after operation, but their long-term effect needs further follow-up studies. PEC may increase the risk of negative outcomes of the postoperative urinary flow rate, while HLC has the advantages of better relieving the patient's anxiety, sooner discharge from hospital and earlier recovery from postoperative hematuria, though with a higher total cost than the former.


Asunto(s)
Adulto , Humanos , Masculino , Persona de Mediana Edad , Adulto Joven , Cauterización , Eyaculación , Hematuria/cirugía , Holmio , Terapia por Láser , Láseres de Estado Sólido/uso terapéutico , Resultado del Tratamiento
15.
J. appl. oral sci ; 28: e20200528, 2020. tab, graf
Artículo en Inglés | LILACS, BBO | ID: biblio-1143147

RESUMEN

Abstract Implant surface decontamination is a challenging procedure for therapy of peri-implant disease. Objective: This study aimed to compare the effectiveness of decontamination on oral biofilm-contaminated titanium surfaces in Er:YAG laser, Er, Cr:YSGG laser, and plastic curette. Methodology: For oral biofilms formation, six participants wore an acrylic splint with eight titanium discs in the maxillary arch for 72 hours. A total of 48 contaminated discs were distributed among four groups: untreated control; decontamination with plastic curettes; Er, Cr:YSGG laser; and Er:YAG laser irradiation. Complete plaque removal was estimated using naked-eye and the time taken was recorded; the residual plaque area was measured and the morphological alteration of the specimen surface was observed by scanning electron microscopy. The total bacterial load and the viability of adherent bacteria were quantified by live or dead cell labeling with fluorescence microscopy. Results: The mean treatment time significantly decreased based on the treatment used in the following order: Er:YAG, Er, Cr:YSGG laser, and plastic curettes (234.9±25.4 sec, 156.1±12.7 sec, and 126.4±18.6 sec, P=0.000). The mean RPA in the Er, Cr:YSGG laser group (7.0±2.5%) was lower than Er:YAG and plastic curettes groups (10.3±2.4%, 12.3±3.6%, p=0.023). The viable bacteria on the titanium surface after Er, Cr:YSGG laser irradiation was significantly lower compared to the decontamination with plastic curette (P=0.05) but it was not significantly different from the Er:YAG laser irradiation. Conclusion: We found that Er:YAG laser and Er, Cr:YSGG laser irradiation were effective methods for decontaminations without surface alterations.


Asunto(s)
Humanos , Titanio , Microscopía Electrónica de Rastreo , Láseres de Estado Sólido/uso terapéutico
16.
Int. j. odontostomatol. (Print) ; 13(4): 481-485, dic. 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1056488

RESUMEN

ABSTRACT: The pigmented lesions of the oral cavity may be endogenous or exogenous. Endogenous lesions are benign and usually caused by melanin, and they are called gingival melanin pigmentations. Among the options for depigmenting these areas, laser therapy stands out for being a minimally invasive procedure. This study aims to report a clinical case of the gingival depigmentation technique using a high-power diode laser in the anterior maxillary region, for the ablation of the pigmented tissue to improve gingival aesthetics. The patient had an aesthetic complaint of the darkened aspect of the gingiva in the anterior maxillary and mandibular portions. After local anesthesia, we started depigmentation with high-power diode laser and performed ablation from the attached gingiva toward the free marginal gingiva. The patient returned after 30 and 180 days presenting healthy gingiva and absence of melanin repigmentation. Thus, we concluded that the diode laser was a good alternative for melanin depigmentation because it is a procedure with lower morbidity and satisfactory postoperative results.


RESUMEN: Las lesiones pigmentadas de la cavidad oral pueden ser endógenas o exógenas. Las endógenas son benignas y generalmente causadas por la melanina, denominándose pigmentaciones melánicas gingivales. Entre las opciones para la despigmentación de estas regiones, se destaca la laserterapia, por ser un procedimiento poco invasivo. Este trabajo tuvo como objetivo relatar un caso clínico de la técnica de despigmentación gingival utilizando láser de diodo de alta intensidad en la región anterior de los maxilares para ablación del tejido pigmentado con la finalidad de mejorar la estética gingival. El paciente presentaba como queja estética el aspecto oscurecido de la encía en la región anterior de la maxila y de la mandíbula. Tras aplicar anestesia local, se inició la despigmentación con láser de diodo de alta intensidad, siendo que la ablación se realizó a partir de la encía insertada hacia la encía marginal libre. El paciente regresó tras 30 y 180 días, presentando encía saludable y con ausencia de repigmentación melánica. Así fue posible concluir que el láser de diodo mostró ser una buena alternativa para la despigmentación melánica, ya que se presentó como un procedimiento con menor morbidad y buen resultado postoperatorio.


Asunto(s)
Humanos , Masculino , Adulto , Terapia por Láser/métodos , Láseres de Estado Sólido/uso terapéutico , Enfermedades de las Encías/cirugía , Melanosis/cirugía , Brasil , Técnicas Cosméticas/instrumentación , Consentimiento Informado
17.
Int. braz. j. urol ; 45(6): 1161-1166, Nov.-Dec. 2019. tab
Artículo en Inglés | LILACS | ID: biblio-1056350

RESUMEN

ABSTRACT Purpose: To compare two-shift operation mode and single player mode different impact on surgical results and operator comfort in flexible ureteroscopic holmium laser lithotripsy for renal calculi larger than 1.5cm. Materials and Methods: From december 2017 to december 2018, 92 patients with renal calculi admitted to Qilu Hospital and were treated through flexible ureteroscopy. They were randomized in two-shift group (n=50) and single player group (n=42). The operative time, blood loss, hospitalization stay after operation, residual fragments (≥4mm) rate, fragmentation speed, postoperative complications and operator's fatigue score were compared. Results: There was no significant difference between two groups regarding age, gender, illness side, stone size, blood loss, operative time, postoperative hospitalization stay, complications, etc (p >0.05). The fragmentation speed was 44.5±20.0mm3/min in two-shift group compared with 34.2±17.3mm3/min in single player group (p=0.037). Residual fragments (≥4mm) rate after first surgery was 18% in two-shift group, while the residual fragments (≥4mm) rate was 40.5% after first surgery in single player group (p=0.017). The total fatigue score of two-shift group was 8.4 compared to 29.9 in single player group (p <0.001). Conclusion: In flexible ureteroscopic holmium laser lithotripsy for the treatment of renal calculi larger than 1.5cm, two-shift operation mode can raise the fragmentation speed and stone clearance rate, as well as significantly lower operator's fatigue level and improve operator's comfort.


Asunto(s)
Humanos , Masculino , Femenino , Adulto , Cálculos Renales/cirugía , Litotripsia por Láser/métodos , Ureteroscopía/métodos , Láseres de Estado Sólido/uso terapéutico , Complicaciones Posoperatorias , Cálculos Renales/patología , Reproducibilidad de los Resultados , Resultado del Tratamiento , Litotripsia por Láser/instrumentación , Ureteroscopía/instrumentación , Diseño de Equipo , Tempo Operativo , Ergonomía , Tiempo de Internación , Persona de Mediana Edad
18.
Int. braz. j. urol ; 45(4): 853-853, July-Aug. 2019.
Artículo en Inglés | LILACS | ID: biblio-1040056

RESUMEN

ABSTRACT Introduction Urological surgery is estimated to be the third most common cause of iatrogenic-retained foreign bodies 1. Presentation A 76-year old man was undergoing a transurethral resection of bladder tumor with a 26-Ch continuous flow resectoscope (Karl Storz, Germany). Before starting resection, a detachment of resectoscope sheath tip was noted. The ceramic tip was free-floating in the bladder lumen, and it would not fit within the sheath, making direct extraction using the loop impossible. An attempt was made to break it with a stone punch, but it was unsuccessful due to impossibility of closing it in the branches. Therefore, we decided to fragment the tip with holmium laser (RevoLix®, LISA Laser products, Germany), using an 800-micron, front-firing fiber. Laser device was settled at with 2.5 J energy and 5 Hz frequency. Ceramic appeared very hard, but it was difficult to carry on breaking with this setting because of tip retropulsion. Then, laser setting was switched to lower energy and higher frequency (1 J and 13 Hz). This setting guaranteed the same power of 13 W, but with minimal retropulsion. Results Tip was fragmented against the posterior bladder wall in seven pieces, which were retrieved trough the outer sheath. A total 5.62 kJ were used to fragment it. At the end, superficial lesions of the posterior bladder wall were highlighted. Surgical time was 55 minutes. Patient was discharged home next day without problems. Conclusions Holmium laser fragmentation is a safe and effective approach to remove foreign bodies from the bladder.


Asunto(s)
Humanos , Masculino , Anciano , Vejiga Urinaria/cirugía , Cerámica/efectos de la radiación , Falla de Equipo , Láseres de Estado Sólido/uso terapéutico , Cuerpos Extraños/cirugía , Dosis de Radiación , Factores de Tiempo , Neoplasias de la Vejiga Urinaria/cirugía , Resultado del Tratamiento , Tempo Operativo
19.
Notas enferm. (Córdoba) ; 19(33): 40-48, jun.2019.
Artículo en Español | LILACS, BDENF, BINACIS, UNISALUD | ID: biblio-1008164

RESUMEN

Este trabajo muestra el uso del láser Holmium en procedimientos endourológicos, el mismo se utiliza en dos técnicas quirúrgicas: Ureteroscopía y Enucleación de próstata con láser Holmium (HoLEP), las cuales se realizan con mayor frecuencia en la institución. Son procedimientos en los que el trabajo interdisciplinario, en equipo, tiene como principal objetivo mejorar la calidad de vida de nuestros pacientes. En esta institución, desde el año 2017, se realizó un cálculo de procedimientos en los cuales se utilizó el láser Holmium. En la muestra se detallan: 28 HoLEP, 27 ureteroscopías y 3 litotricias endovesicales. Este es un trabajo con modalidad monográfca y con la experiencia en terreno de tan solo un año aproximadamente(AU)


Tis work shows the use of the Holmium laser in endourological procedures, which is used in two surgical techniques: Ureteroscopy and Enucleation of prostate with Holmium laser (HoLEP), which are performed more frequently in the institution. Tese are procedures in which interdisciplinary work, as a team, has as its main objective to improve the quality of life of our patients. In this institution, since 2017, a calculation of procedures in which the Holmium laser was used was performed. Te sample shows: 28 HoLEP, 27 ureteroscopies and 3 endovesical lithotripsies. Tis is a monographic work with feld experience of only about one year(AU)


Este trabalho mostra o uso do laser de hólmio em procedimentos endourológicos, que é utilizado em duas técnicas cirúrgicas: Ureteroscopia e Enucleação de próstata com laser de hólmio (HoLEP), que são realizadas com maior frequência na instituição. São procedimentos em que o trabalho interdisciplinar, como equipe, tem como principal objetivo melhorar a qualidade de vida de nossos pacientes. Nesta instituição, desde 2017, foi realizado um cálculo dos procedimentos em que foi utilizado o laser de hólmio. A amostra mostra: 28 HoLEP, 27 ureteroscopies e 3 litotripsies endovesical. Este é um trabalho monográfco com experiência de campo de apenas cerca de um ano(AU)


Asunto(s)
Humanos , Litotripsia por Láser , Ureteroscopía/métodos , Láseres de Estado Sólido/uso terapéutico , Nefrolitiasis
20.
Arq. bras. oftalmol ; 82(3): 189-194, May-June 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1001312

RESUMEN

ABSTRACT Purpose: The purpose of this study was to objectively assess the optical vision quality of patients before and after Nd:YAG capsulotomy for posterior capsular opacification using a double-pass retinal imaging system. Methods: We retrospectively analyzed the data from 26 pseudophakic eyes with posterior capsular opacification that underwent Nd:YAG capsulotomy. The objective scatter indices, modulation transfer function cutoff frequencies, Strehl ratios, and logMAR corrected distance visual acuities were assessed before and after YAG capsulotomy with a double-pass retinal imaging system (OQAS II, Visiometrics, Spain). We also analyzed data from a subgroup of 10 patients with pre-YAG corrected distance visual acuity of 0.10 logMAR (20/25) or better. Results: Vision quality indices improved in all 26 eyes, resulting in a statistically significant improvement in the corrected distance visual acuity (p=0.007), objective scatter index (p=0.001), modulation transfer function cutoff frequency (p=0.001), and Strehl ratio (p=0.020). The overall mean improvements included 0.12 ± 0.04 logMAR for corrected distance visual acuity, 2.84 ± 0.76 for objective scatter index, 12.29 ± 2.77 for modulation transfer function cutoff frequency, and 0.06 ± 0.03 for Strehl ratio. Our sub-analysis of 10 eyes with 0.10 logMAR (20/25) corrected distance visual acuity or better also showed a statistically significant improvement in the mean objective scatter index (0.76 ± 16; p=0.001), resulting in approximately 35% decrease in intraocular light scatter. Conclusions: The objective vision quality measurements as assessed by the double-pass retinal imaging system showed a significant improvement after YAG capsulotomy. This suggests that the objective scatter index improves after YAG capsulotomy, even in eyes with pre-YAG 0.10 logMAR (Snellen 20/25) corrected distance visual acuity or better.


RESUMO Objetivo: Avaliar objetivamente a qualidade da visão óptica antes e depois da capsulotomia com Nd: YAG, obtida por imagem pelo metodo de dupla passagem de luz em pacientes com opacificação capsular posterior. Método: Análise retrospectiva de 26 olhos pseudofácicos com opacificação capsular posterior visualmente significativa, que foram submetidos à capsulotomia de Nd: YAG. O índice de dispersão objetiva, a função de transferência de modulação, a relação de Strehl e a acuidade visual à distância corrigida foram avaliados antes e após a capsulotomia com YAG usando o dupla passagem de luz (OQAS II, Visiometrics, Espanha). Também foi analisado um subgrupo de pacientes com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (20/25) ou melhor. Resultados: Os índices de qualidade da visão melhoraram em todos os 26 olhos, resultando em uma melhora estatisticamente significativa na acuidade visual à distância corrigida (p=0,007), índice de dispersão objetiva (p=0,001), função de transferência de modulação (p=0,001) e relação de Strehl (p=0,020). A melhora média na acuidade visual à distância corrigida foi de 0,12 ± 0,04 logMAR, no índice de dispersão objetiva foi de 2,84 ± 0,76, no função de transferência de modulação foi de 12,29 ± 2,77 e na razão de Strehl foi de 0,06 ± 0,03 em todos os olhos. Sub-análise de 10 olhos com 0.10 logMAR (20/25) acuidade visual à distância corrigida ou melhor também mostrou uma melhora estatisticamente significativa no índice de dispersão objetiva (p=0,001). A melhora média no OSI foi de 0,76 ± 16, uma diminuição de 35% na dispersão da luz intraocular. Conclusões: A qualidade da visão avaliada pelo dupla passagem de luz mostra uma melhora significativa nas medidas objetivas da qualidade da visão após a capsulotomia do YAG. O índice de dispersão objetiva melhora após a capsulotomia YAG, mesmo em olhos com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (Snellen 20/25) ou melhor.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Agudeza Visual/fisiología , Seudofaquia/fisiopatología , Opacificación Capsular/fisiopatología , Capsulotomía Posterior/rehabilitación , Valores de Referencia , Retina/fisiopatología , Retina/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento , Seudofaquia/diagnóstico por imagen , Láseres de Estado Sólido/uso terapéutico , Opacificación Capsular/diagnóstico por imagen , Capsulotomía Posterior/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA