Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Añadir filtros








Intervalo de año
1.
Gut and Liver ; : 932-938, 2016.
Artículo en Inglés | WPRIM | ID: wpr-132227

RESUMEN

BACKGROUND/AIMS: Because Methanobrevibacter smithii produces methane, delaying gut transit, we evaluated M. smithii loads in irritable bowel syndrome (IBS) patients and healthy controls (HC). METHODS: Quantitative real-time polymerase chain reaction for M. smithii was performed on the feces of 47 IBS patients (Rome III) and 30 HC. On the lactulose hydrogen breath test (LHBT, done for 25 IBS patients), a fasting methane result ≥10 ppm using 10 g of lactulose defined methane-producers. RESULTS: Of 47, 20 had constipation (IBS-C), 20 had diarrhea (IBS-D) and seven were not sub-typed. The M. smithii copy number was higher among IBS patients than HC (Log₁₀5.4, interquartile range [IQR; 3.2 to 6.3] vs 1.9 [0.0 to 3.4], p<0.001), particularly among IBS-C compared to IBS-D patients (Log₁₀6.1 [5.5 to 6.6] vs 3.4 [0.6 to 5.7], p=0.001); the copy number negatively correlated with the stool frequency (R=−0.420, p=0.003). The M. smithii copy number was higher among methane-producers than nonproducers (Log₁₀6.4, IQR [5.7 to 7.4] vs 4.1 [1.8 to 5.8], p=0.001). Using a receiver operating characteristic curve, the best cutoff for M. smithii among methane producers was Log₁₀6.0 (sensitivity, 64%; specificity, 86%; area under curve [AUC], 0.896). The AUC for breath methane correlated with the M. smithii copy number among methane producers (r=0.74, p=0.008). Abdominal bloating was more common among methane producers (n=9/11 [82%] vs 5/14 [36%], p=0.021). CONCLUSIONS: Patients with IBS, particularly IBS-C, had higher copy numbers of M. smithii than HC. On LHBT, breath methane levels correlated with M. smithii loads.


Asunto(s)
Humanos , Área Bajo la Curva , Pruebas Respiratorias , Estreñimiento , Diarrea , Ayuno , Heces , Hidrógeno , Síndrome del Colon Irritable , Lactulosa , Metano , Methanobrevibacter , Reacción en Cadena en Tiempo Real de la Polimerasa , Curva ROC , Sensibilidad y Especificidad
2.
Gut and Liver ; : 932-938, 2016.
Artículo en Inglés | WPRIM | ID: wpr-132230

RESUMEN

BACKGROUND/AIMS: Because Methanobrevibacter smithii produces methane, delaying gut transit, we evaluated M. smithii loads in irritable bowel syndrome (IBS) patients and healthy controls (HC). METHODS: Quantitative real-time polymerase chain reaction for M. smithii was performed on the feces of 47 IBS patients (Rome III) and 30 HC. On the lactulose hydrogen breath test (LHBT, done for 25 IBS patients), a fasting methane result ≥10 ppm using 10 g of lactulose defined methane-producers. RESULTS: Of 47, 20 had constipation (IBS-C), 20 had diarrhea (IBS-D) and seven were not sub-typed. The M. smithii copy number was higher among IBS patients than HC (Log₁₀5.4, interquartile range [IQR; 3.2 to 6.3] vs 1.9 [0.0 to 3.4], p<0.001), particularly among IBS-C compared to IBS-D patients (Log₁₀6.1 [5.5 to 6.6] vs 3.4 [0.6 to 5.7], p=0.001); the copy number negatively correlated with the stool frequency (R=−0.420, p=0.003). The M. smithii copy number was higher among methane-producers than nonproducers (Log₁₀6.4, IQR [5.7 to 7.4] vs 4.1 [1.8 to 5.8], p=0.001). Using a receiver operating characteristic curve, the best cutoff for M. smithii among methane producers was Log₁₀6.0 (sensitivity, 64%; specificity, 86%; area under curve [AUC], 0.896). The AUC for breath methane correlated with the M. smithii copy number among methane producers (r=0.74, p=0.008). Abdominal bloating was more common among methane producers (n=9/11 [82%] vs 5/14 [36%], p=0.021). CONCLUSIONS: Patients with IBS, particularly IBS-C, had higher copy numbers of M. smithii than HC. On LHBT, breath methane levels correlated with M. smithii loads.


Asunto(s)
Humanos , Área Bajo la Curva , Pruebas Respiratorias , Estreñimiento , Diarrea , Ayuno , Heces , Hidrógeno , Síndrome del Colon Irritable , Lactulosa , Metano , Methanobrevibacter , Reacción en Cadena en Tiempo Real de la Polimerasa , Curva ROC , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA