Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
1.
Braz. j. biol ; 84: e254016, 2024. tab
Artículo en Inglés | LILACS, VETINDEX | ID: biblio-1364529

RESUMEN

The present study was conducted to isolate and characterize bacteria from water and soil sample taken from the Lahore Canal at different sites i.e. Mall Road, Mohlanwal and Khera site. Isolated bacterial strains were identified on the basis of morphological and biochemical tests. Identification was confirmed by culturing bacteria on selective media. Antibiotic resistance test was also performed to observe the resistance of bacteria against different antibiotics. Blood agar test was performed for identification of different pathogenic bacteria. The result revealed that water and soil samples of Lahore Canal Lahore from different sites were contaminated with Escherichia coli, Salmonella sp., Vibrio sp., Bacillus spp., Enterococcus sp. and Staphylococcus spp. Due to presence of these pathogens, this water is not suitable for any domestic and irrigation use. Study also revealed that water of the Lahore Canal is harmful for human health as it is contaminated with bacteria that can cause severe disease e.g., Escherichia coli can cause gastroenteritis, Bacillus spp. can cause nausea and vomiting, Enterococcus may infect urinary tract, Salmonella sp. is responsible for Bacteremia, Staphylococcus spp. can cause mild fever and Vibrio sp. can be the reason of cholera. Thus it is rendered unfit for any kind of human use even other than drinking like swimming, bathing, washing etc., until and unless some remedial measures are employed to eradicate pathogenic microorganisms by WASA and LWMS according to standards of WHO. Similarly, it is quite harmful, when and where ever it is used for irrigation without proper treatment.


O presente estudo foi realizado para isolar e caracterizar bactérias de amostras de água e solo retiradas do Canal Lahore, em Lahore, em diferentes locais, ou seja, Mall Road, Mohlanwal e Khera. As cepas bacterianas isoladas foram identificadas com base em testes morfológicos e bioquímicos. A identificação foi confirmada por cultura de bactérias em testes de meios seletivos. O teste de resistência aos antibióticos também foi realizado para observar a resistência das bactérias a diferentes antibióticos. Foi realizado o teste de ágar sangue para identificar diferentes bactérias patogênicas. O resultado revelou que amostras de água e solo do Canal Lahore, Lahore, de diferentes localidades estavam contaminadas com Escherichia coli, Salmonella sp., Vibrio sp., Bacillus spp., Enterococcus sp. e Staphylococcus spp. Por causa da presença desses patógenos, essa água não é adequada para qualquer uso doméstico e de irrigação. O estudo revelou que a água do Canal Lahore é prejudicial à saúde humana, pois está contaminada com bactérias que podem causar doenças graves, por exemplo: Escherichia coli pode ocasionar gastroenterite; Bacillus spp. pode causar náuseas e vômitos; Enterococcus sp. pode infectar o trato urinário; Salmonella sp. é responsável pela bacteremia; Staphylococcus spp. pode causar febre leve; e Vibrio sp. pode ser a razão da cólera. Assim, torna-se imprópria para uso humano, como natação, banho, lavagem etc., até que algumas medidas corretivas sejam empregadas para erradicar microrganismos patogênicos por WASA e LWMS de acordo com os padrões da OMS. Da mesma forma, é bastante prejudicial, quando usada para irrigação sem tratamento adequado.


Asunto(s)
Animales , Suelo , Staphylococcus , Vibrio , Farmacorresistencia Microbiana , Muestras de Agua , Enterococcus , Escherichia coli
2.
J. Health Biol. Sci. (Online) ; 10(1): 1-6, 01/jan./2022. ilus
Artículo en Portugués | LILACS | ID: biblio-1411593

RESUMEN

Objetivo: realizar análises parasitológicas em amostras de solo provenientes da represa da Bica situada no município de Catalão-GO. Métodos: a área do entorno da represa foi dividida em cinco parcelas, sendo realizadas coletas em dois pontos de cada parcela, superior e inferior. Foram realizadas quatro coletas em dias alternados, totalizando 40 amostras de, aproximadamente, 50g da camada superficial do solo, com profundidade máxima de cinco centímetros. As amostras foram processadas no Setor de Diagnóstico Parasitológico do Laboratório de Biologia Molecular da Universidade Federal de Catalão (UFCAT). Para as análises parasitológicas, foram utilizados cinco métodos encontrados na literatura, Rugai, Willis, Sedimentação espontânea, Ritchie e Ritchie modificado. Resultados: pelo método de Rugai, foi possível detectar larvas rabditoides do gênero Ancylostoma e Strongyloides. Utilizando o método de Ritchie modificado, foram encontrados ovos de Ascaris lumbricoidese Ancylostoma sp. Conclusão: a presença de formas evolutivas no solo da represa indica contaminação por dejetos animais e humanos, favorecendo o estabelecimento de ciclos biológicos das espécies encontradas e de outras diferentes zoonoses. Os dados obtidos demonstram a importância de sensibilizar a população de medidas de promoção da saúde, além de ações preventivas e programas de educação em saúde.


Objective: to conduct parasitological analyses in soil samples from the Bica reservoir located in the municipality of Catalão-GO. Methods: the area around the dam was divided into five plots, and samples were collected from two points in each plot, upper and lower. Four samples were collected on alternate days, totaling 40 samples of approximately 50g of topsoil, with a maximum depth of five centimeters. The samples were processed in the Parasitological Diagnostic Sector of the Molecular Biology Laboratory of the Federal University of Catalão (UFCAT). For the parasitological analyses, we used five methods found in the literature, Rugai, Willis, spontaneous sedimentation, Ritchie, and modified Ritchie. Results: by the Rugai method, it was possible to detect rhabditoid larvae of the genus Ancylostoma and Strongyloides. Using the modified Ritchie method, eggs of Ascaris lumbricoidesand Ancylostoma sp were found. Conclusion: the presence of evolutive forms in the soil of the reservoir indicates contamination by animal and human waste, favoring the establishment of biological cycles of the species found and of other different zoonoses. The data obtained demonstrated the importance of raising the population's awareness of health promotion measures besides preventive actions and health education programs.


Asunto(s)
Suelo/parasitología , Presas , Muestras de Agua , Nematodos/parasitología , Ascaris/parasitología , Brasil , Análisis del Suelo , Contaminación Ambiental/prevención & control , Ancylostoma/parasitología , Larva/parasitología
3.
Rev. Inst. Adolfo Lutz (Online) ; 80: e37246, dez. 2021. mapas, ilus, tab, graf
Artículo en Portugués | LILACS, CONASS, ColecionaSUS, SES-SP, VETINDEX, SESSP-ACVSES, SESSP-IALPROD, SES-SP, SESSP-IALACERVO | ID: biblio-1359203

RESUMEN

A água utilizada em serviços de hemodiálise passa por um sistema de tratamento a fim de garantir que os parâmetros microbiológicos e físico-químicos estejam adequados e proporcionem segurança ao paciente. Este trabalho avaliou a qualidade da água antes e após esta passar por sistema de tratamento em dois serviços (A e B) de hemodiálise em Santarém. Foram coletadas amostras de água em três pontos: Ponto 1 (P1) após saída do poço, Ponto 2 (P2) na saída do tratamento e Ponto 3 (P3) na máquina de hemodiálise. Testes microbiológicos e físico-químicos foram realizados e os resultados mostraram que não houve crescimento de coliformes totais e Escherichia coli nas amostras. No serviço A, houve contaminação por bactérias heterotróficas em 87% das amostras, destas, 27% ocorreram no P3. O pH mostrou-se menor que 6,0 no P1 nos dois serviços, normalizando os seus valores no P3. No serviço A, concentrações superiores ao recomendado de alumínio e nitrato foram verificadas em 100% das amostras coletadas no P1, os valores foram normalizados na saída do tratamento (P2). A pesquisa demonstrou que, para os parâmetros estudados, a qualidade da água, após passar por sistema de tratamento, é satisfatória, com exceção das bactérias heterotróficas no serviço A. (AU)


The water used in hemodialysis services goes through a treatment system in order to ensure that the microbiological and physicochemical parameters are adequate and provide safety to the patient. This work evaluated the quality of water before and after it went through a treatment system in two hemodialysis services (A and B) in Santarém. Water samples were collected at three points: Point 1 (P1) after leaving the well, Point 2 (P2) leaving the treatment and Point 3 (P3) on the hemodialysis machine. Microbiological and physical-chemical tests were performed and the results showed no growth of total coliforms and Escherichia coli in the samples. In service A, there was contamination by heterotrophic bacteria in 87% of the samples, 27% of which occurred in P3. The pH was less than 6.0 in P1 in both services, normalizing its values in P3. Service A, concentrations higher than the recommended amount of aluminum and nitrate were verified in 100% of the samples collected in P1, the values were normalized at the end of the treatment (P2). The research demonstrated that, for the studied parameters, the water quality, after going through a treatment system, is satisfactory, with the exception of heterotrophic bacteria in service A. (AU)


Asunto(s)
Colimetría/métodos , Muestras de Agua , Diálisis Renal , Plantas de Tratamiento de Agua
4.
Rio de Janeiro; s.n; 00.00.2021. 363 p. tab, ilus, graf, mapas.
Tesis en Portugués | LILACS, SES-RJ | ID: biblio-1571200

RESUMEN

O presente trabalho tem como objetivo avaliar a qualidade da água distribuída pelas concessionárias nos municípios de Resende, Porto Real, Barra Mansa, Volta Redonda e Pinheiral na região Sul Fluminense do estado do Rio de Janeiro, local de atuação do Comitê Médio Paraíba do Sul. As avaliações foram feitas confrontando as informações presentes nas contas de água emitidas pelas concessionárias aos seus clientes, com os resultados medidos referentes à qualidade da água do presente estudo (água tratada distribuída e água tratada distribuída final de rede de distribuição) e com os resultados emitidos pelas concessionárias para o Sistema de Informação em Saúde da Água (SISAGUA). Foi avaliado o tratamento da água e sua distribuição para o consumo humano. De um modo geral, todas as concessionárias fazem o tratamento tipo convencional e não possui em seu sistema qualquer outro tipo de tratamento que possa melhorar a qualidade da água. As comparações realizadas pelo estudo demonstram que todas as concessionárias tiveram problemas com os parâmetros Fluoreto e Cor. Ao final do estudo foi gerada uma classificação regional onde foram elencadas às concessionárias em relação à qualidade de água distribuída tendo como base o cálculo do IQA-CCME. Para o presente estudo o padrão "ideal" foi baseado nos limites determinados pela Portaria de Consolidação nº 5/2017 (do Ministério da Saúde) e pelo Instituto Trata Brasil. Esta pesquisa foi iniciada em dezembro de 2018 e terminou em dezembro de 2019. Em cada município foram coletadas, mensalmente, amostras de água em 3 pontos: água bruta, água tratada no início e ao final da sua distribuição. Ao todo foram realizadas 12 coletas de água bruta e 12 de água tratada distribuída e 6 de água tratada final de rede. Para a água bruta, foram analisados 13 parâmetros e para a água tratada, foram realizados 23 parâmetros (13 para a água tratada distribuída e 10 para a água tratada distribuída final de rede). No estudo todo foram feitas 1.860 determinações. Durante o período pesquisado, foi criado um banco com as informações obtidas das análises. Os cálculos dos IQAs foram estabelecidos pelos critérios dos Índices de Qualidade de Água Canadian Council of Ministers of the Environment (IQA­CCME) e pôde-se criar a classificação regional dos municípios estudados. Os resultados apontaram que a melhor qualidade de água distribuída nos municípios estudados foi em Volta Redonda (classificada como boa e IQA­CCME de 89,99), seguida por Resende (boa com 86,64), Barra Mansa obteve o IQA­CCME de 86,60 bem próximo ao segundo lugar. A água do município de Pinheiral já apresentou qualidade mediana com IQA­CCME de 48,04. A pior qualidade de água distribuída é em Porto Real onde obteve o IQA­CCME mais baixo 37,71 segundo os critérios de qualificação adotados. (AU)


The present work aims to evaluate the quality of the water distributed by the concessionaires in the cities of Resende, Porto Real, Barra Mansa, Volta Redonda and Pinheiral in the South Fluminense region of the state of Rio de Janeiro, where the Paraíba do Sul Middle Committee operates. The assessments were made by comparing the information present in the water bills issued by the concessionaires to their customers, with the measured results referring to the water quality of the present study (distributed treated water and final distributed treated water from the distribution network) and with the results issued by the concessionaires for the Water Health Information System (SISAGUA). The treatment of water and its distribution for human consumption was evaluated. In general, all concessionaires do conventional treatment and do not have any other type of treatment in their system that can improve water quality. The comparisons made by the study show that all concessionaires had problems with the parameters Fluoride and Color. At the end of the study, a regional classification was generated where the concessionaires were listed in relation to the quality of water distributed based on the calculation of the indexes quality of the water Canadian Council of Ministers of the Environment (IQA-CCME). For the present study, the "ideal" standard was based on the limits determined by Consolidation Ordinance No. 5/2017 (from the Ministry of Health) and by the Trat Brazil Institute. This research started in December 2018 and ended in December 2019. In each city, water samples were collected monthly at 3 points: raw water, treated water at the beginning and at the end of its distribution. In total, 12 collections of raw water and 12 of treated treated water and 6 of final treated water were carried out. For raw water, 13 parameters were analyzed and for treated water, 23 parameters were performed (13 for distributed treated water and 10 for final distributed treated water). In the whole study, 1,860 determinations were made. During the research period, a bank was created with the information obtained from the analyzes. The calculations of the IQAs were established by the criteria of the IQA-CCME and it was possible to create the regional classification of the municipalities studied. The results showed that the best quality of water distributed in the municipalities studied was in Volta Redonda (classified as good and IQA ­ CCME of 89.99), followed by Resende (good with 86.64), Barra Mansa obtained the IQA ­ CCME of 86.60 right next to the second place. The water in the municipality of Pinheiral has already presented a median quality with AAI-CCME of 48.04. The worst quality of water distributed is in Porto Real where it obtained the lowest IQA ­ CCME 37.71 according to the adopted qualification criteria. (AU)


Asunto(s)
Calidad del Agua , Muestras de Agua , Salud , Purificación del Agua , Ambiente
5.
Semina cienc. biol. saude ; 41(2): 263-272, jun./dez. 2020. Tab
Artículo en Portugués | LILACS | ID: biblio-1224458

RESUMEN

Escherichia coli diarreiogênica (DEC) é um importante agente de infecções gastrointestinais transmitidas pela água. O trabalho teve como objetivo avaliar a qualidade microbiológica e físicoquímica de 58 amostras de água subterrânea in natura para consumo de um assentamento rural e caracterizar os isolados de E. coli, genotipicamente dentro dos patotipos de DEC, pela técnica da PCR, e fenotipicamente. Todas as amostras apresentaram contaminação por coliformes totais e 36 (62,1%) por E. coli. Em células HEp-2, dos 170 isolados de E. coli, 106 (62,36%) apresentaram AA, 15 (8,82%) AD, 17 (10%) adesão não caracterizado e 32 (18,82%) foram não aderentes. Quanto à formação de biofilme, 126 (74,12%) cepas são formadoras, e 44 (25,88%) não formaram biofilme. Foram identificadas DEC em 6,89% das amostras de água: três (5,17%) ETEC e uma (1,72%) EAEC. EAEC apresentou AA e as três cepas de ETEC apresentaram AD, AA e não definida. Todas as DEC foram formadoras de biofilme. Dois isolados de ETEC apresentaram resistência à ampicilina e tetraciclina, uma ETEC à aminoglicosídeos, e EAEC foi sensível a todos os antibióticos testados. As ETEC foram classificadas no filogrupo B1 e a EAEC no E. Os sorotipos encontrados foram: O24:H21, OR:H21, O17:H46 e O6:H12. Todas as amostras estavam dentro dos parâmetros normais de flúor e 13 (22,4%) apresentaram resultados acima do padrão permitido de turbidez. A presença de E. coli e DEC nas amostras de água indica a necessidade de adoção de medidas que evitem a contaminação da água fornecida à população, evitando, assim, a transmissão de doenças.(AU)


Diarrheogenic Escherichia coli (DEC) is an important agent of waterborne gastrointestinal infections. The objective of this work was to evaluate the microbiological and physico-chemical quality of 58 freshwater groundwater samples for the consumption of a rural settlement and to characterize the E. coli isolates, genotyped within the DEC pathophyses, by the PCR technique, and phenotypically. All water samples presented contamination with total coliforms, and 36 (62.1%) with E. coli. In HEp-2 cells, of 170 E. coli isolates, 106 (62.36%) showed AA, 15 (8.82%) AD, 17 (10%) noncharacterized adhesion and 32 (18.82%) were non-adherent. As for biofilm formation, 126 (74.12%) strains are forming, and 44 (25.88%) did not form biofilm. DEC was identified in 6.89% of the water samples with E. coli: three (5.17%) with enterotoxigenic E. coli (ETEC), and one (1.72%) with enteroaggregative E. coli (EAEC). EAEC showed aggregative adherence, whereas various ETEC strains presented diffuse, aggregative, and non-defined adherence. All DEC strains were biofilm forming. Two isolates of ETEC showed resistance to ampicillin and tetracycline, and one isolate showed resistance to aminoglycosides. The EAEC isolate was sensitive to all antibiotics tested. All ETECs were classified into phylogenetic B1 and EAEC in E. The serotypes identified in our study were: O24:H21, ONT:H21, O17:H46, and O6:H12. All water samples were within normal fluorine parameters; however, measured turbidity was above the permitted standard in 13 (22.4%) samples. The presence of E. coli and DEC in water samples indicates the need to take action to prevent contamination of water resources accessed by people to prevent the transmission of diseases.(AU)


Asunto(s)
Humanos , Muestras de Agua , Escherichia coli , Escherichia coli Enterotoxigénica , Enfermedad
6.
NOVA publ. cient ; 18(33): 101-112, ene.-jun. 2020. tab, graf
Artículo en Español | LILACS | ID: biblio-1149451

RESUMEN

Resumen Objetivo. Determinar características bacteriológicas, físicas y pH del agua para consumo humano que abastece al municipio de Une, Cundinamarca-Colombia. Métodos. Se tomaron 13 muestras de agua: 10 de la zona rural y 3 de la zona urbana. Del total de muestras tomadas en la zona rural, 7 no tenían ningún tratamiento, mientras que 3 tenían algún tipo de tratamiento. Las 3 muestras tomadas en la cabecera municipal, todas tenían tratamiento. Se utilizó la técnica de filtración por membrana para los análisis bacteriológicos, y los métodos nefelométrico, turbidimétrico y potenciométrico, para los análisis físicos y el pH. Resultados. Se obtuvo como resultado pH inferior a 6; 12 puntos superan el valor máximo de turbiedad y 5 puntos para la determinación de color. Se observó la presencia de Coliformes totales, E. coli y Enterococcus en las muestras analizadas, en cantidad que sobrepasa lo establecido en la normativa colombiana.


Abstract Objective. To determine bacteriological and physical characteristics and pH of water for human consumption that supplies the municipality of Une, Cundinamarca-Colombia. Methods. Thirteen water samples were taken: 10 from the rural area and 3 from the urban area. Of the total number of samples taken in the rural area, 7 had no treatment at all, while 3 had some type of treatment. The 3 samples taken in the municipal capital, all had treatment. The membrane filtration technique was used for bacteriological analysis and the nephelometric, turbidimetric and potentiometric methods for physical analysis and pH. Results. The result was pH lower than 6; 12 points exceed the maximum value turbidity and 5 points for the determination of color. The presence of total Coliforms, E. coli and Enterococcus was observed in the analyzed samples, in an amount that surpasses the established in the Colombian regulations.


Asunto(s)
Agua , Agua Potable , Muestras de Agua , Técnicas Bacteriológicas , Enterococcus
7.
Braz. J. Pharm. Sci. (Online) ; 56: e17835, 2020. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1089232

RESUMEN

Failure on the water treatment poses hemodialysis patients at risk of injury and death. Identifying if the patients are exposed to water quality related microbiological risks is an important objective to reduce the mortality for chronic renal patients and is the main issue of this study. We evaluated the microbiological water quality used by 205 dialysis services in São Paulo State, Brazil between 2010 to 2016. The study included heterotrophic bacteria count, total coliforms research, and bacterial endotoxin determination in 1366 dialysis water samples. The number of unsatisfactory clinics for at least one microbiological parameter decreased 16.0% between 2010 to 2015 but increased 57.2% in 2016. In 2010, the most frequent unsatisfactory parameter was related to heterotrophic bacteria count (54.8%) followed by endotoxin determination (45.2%). However, in 2013 an opposite situation was observed: endotoxin determination as the parameter of the higher incidence of nonconformities. Total coliform was verified at a lower frequency. We highlighted the importance of regular monitoring of dialysis water quality to prevent infections caused by dialytic procedures and to ensure that the water is a safe component of the treatment.


Asunto(s)
Calidad del Agua , Muestras de Agua , Diálisis Renal/clasificación , Purificación del Agua/instrumentación , Monitoreo del Ambiente , Diálisis/instrumentación , Coliformes , Infecciones/transmisión , Métodos
8.
Braz. J. Pharm. Sci. (Online) ; 56(e17835): 1-9, 2020.
Artículo en Inglés | CONASS, ColecionaSUS, SES-SP, LILACS, SESSP-IALPROD, SES-SP | ID: biblio-1425768

RESUMEN

Failure on the water treatment poses hemodialysis patients at risk of injury and death. Identifying if the patients are exposed to water quality related microbiological risks is an important objective to reduce the mortality for chronic renal patients and is the main issue of this study. We evaluated the microbiological water quality used by 205 dialysis services in São Paulo State, Brazil between 2010 to 2016. The study included heterotrophic bacteria count, total coliforms research, and bacterial endotoxin determination in 1366 dialysis water samples. The number of unsatisfactory clinics for at least one microbiological parameter decreased 16.0% between 2010 to 2015 but increased 57.2% in 2016. In 2010, the most frequent unsatisfactory parameter was related to heterotrophic bacteria count (54.8%) followed by endotoxin determination (45.2%). However, in 2013 an opposite situation was observed: endotoxin determination as the parameter of the higher incidence of nonconformities. Total coliform was verified at a lower frequency. We highlighted the importance of regular monitoring of dialysis water quality to prevent infections caused by dialytic procedures and to ensure that the water is a safe component of the treatment.


Asunto(s)
Muestras de Agua , Monitoreo del Ambiente , Diálisis Renal , Purificación del Agua , Muerte , Bacterias Heterotróficas
9.
Rev. odontol. UNESP (Online) ; 49: e20200017, 2020. tab
Artículo en Inglés | BBO, LILACS | ID: biblio-1144886

RESUMEN

Abstract Introduction Fluoridation of public water supply is an important measure in the prevention of dental caries. Objective This study aimed to monitor the fluoride (F) concentrations of a public water supply with water fluoridation program in a small municipality in the Northeast region of Brazil. Material and method It is a quantitative study with a descriptive approach. Three points of the urban area were selected for collecting water samples twice a month for 12 months. The average of F concentrations was calculated considering these three samples of each collection point at the same occasion. F concentrations in the water samples were determined by potentiometry and the results were classified according to the criterion proposed by criterion set down by Collaborating Center of the Brazilian Ministry of Health for Oral Health Surveillance. The samples were classified according to the best risk-benefit adjustment (0.55 - 0.84 mg F /L). Result Less than 10% of the samples were within the ideal range. Conclusion It was observed that water fluoridation in this municipality was interrupted since many water samples showed f-levels below the minimal acceptable values.


Resumo Introdução A fluoretação das águas de abastecimento público é uma medida importante na prevenção à cárie dentária. Objetivo O objetivo do presente estudo foi avaliar e monitorar os teores de flúor nas águas de abastecimento público em um município de pequeno porte no Nordeste do Brasil. Material e método O estudo apresenta uma abordagem quantitativa de caráter descritivo. Foram selecionados 3 pontos para realizar coleta das águas duas vezes no mês na zona urbana do município durante 12 meses. A concentração de flúor foi obtida pela média das três leituras das amostras analisadas para cada ponto de coleta e classificadas conforme critério proposto pelo Centro Colaborador do Ministério da Saúde em Vigilância da Saúde Bucal. Resultado Segundo o critério utilizado (0,55 - 0,84 mg/L F), apenas 9,7% das amostras estavam dentro do considerado ideal. Conclusão Observou-se que a fluoretação das águas nesse município foi interrompida, pois muitas amostras de água apresentaram níveis de flúor abaixo dos valores mínimos aceitáveis.


Asunto(s)
Abastecimiento de Agua , Caries Dental , Fluoruros , Muestras de Agua , Salud Bucal , Prevención de Enfermedades , Flúor
10.
São Paulo; s.n; 2020. 65 p.
Tesis en Portugués | LILACS | ID: biblio-1145975

RESUMEN

Resumo - O reuso de água contribui nos âmbitos ambientais, sociais e econômicos. Entretanto a presença de parasitos em amostras hídricas tem sido evidenciada por diferentes estudos, entre eles Toxoplasma gondii. A ausência de uma metodologia padronizada para detecção de oocistos em amostras hídricas, dificulta a caracterização das mesmas, comprometendo a elaboração de uma legislação. Tendo em vista a importância do reuso da água na mitigação da escassez, do stress hídrico e diante dos desafios expostos é que o presente trabalho se insere. Objetivos - Propor técnica de concentração e recuperação de oocistos em água de reuso; propor método de extração de DNA; detectar e quantificar oocistos por qPCR. Método - Utilizando o método 1693/2014 USEPA, foram concentrados 30 L de água de reuso de 20 amostras provenientes de duas ETE's da cidade de São Paulo, Brasil. Os 15 mL resultantes desse processo foram concentrados em membrana 0,45µm. O material filtrado na membrana foi recuperado por raspagem com alça bacteriológica de 10 µL. Para extração de DNA foram empregadas duas técnicas: o kit comercial DNeasy PowerSoil Kit® otimizado com a enzima Zymolyase® e choque térmico. A quantificação de DNA foi realizada com a sequência alvo B1. Resultados - Na extração por choque-térmico não foi detectado DNA nas vintes amostras realizadas. Das 16 amostras submetidas à extração enzimática, quatro foram consideradas positivas. Discussão - A extração de DNA consistiu na etapa essencial para detecção e quantificação de oocisto, dado a natureza resistente das paredes. Conclusão - O reuso de água pode ser comprometido na ausência de um protocolo padronizado de detecção e quantificação de oocisto de T. gondii, que possibilite a determinação de parâmetros parasitológicos para elaboração de uma legislação.


Abstract - The wastewater reuse contributes in the environmental, social and economic spheres. However, the presence of parasites in water samples has been evidenced by different studies, including Toxoplasma gondii. The absence of a standardized methodology for detecting oocysts in water samples makes it difficult to characterize them, compromising the drafting of legislation. In view of the importance of wastewater reuse in mitigating water scarcity and stress and in view of the challenges presented, this work is inserted. Objectives - To propose oocyst concentration and recovery techniques in wastewater reuse; propose DNA extraction method; detect and quantify oocysts by qPCR. Method - Using method 1693/2014 USEPA, 30 L of wastewater reuse from 20 samples from two WWTPs in the city of São Paulo, Brazil, were concentrated. The 15 mL resulting from this process were concentrated in a 0.45 µm membrane. The material filtered on the membrane was recovered by scraping with a 10 µL bacteriological loop. For DNA extraction, two techniques were used: the commercial kit DNeasy PowerSoil Kit® optimized with the enzyme Zymolyase® and freeze - thaw. DNA quantification was performed with the target sequence B1. Results - In freeze - thaw extraction, no DNA was detected in the 20 samples performed. Of the 16 samples submitted to enzymatic extraction, four were considered positive. Discussion - DNA extraction was the essential step for oocyst detection and quantification, given the resistant nature of the walls. Conclusion - Wastewater reuse can be compromised in the absence of a standardized protocol for the detection and quantification of T. gondii oocysts, that allows the determination of parasitological parameters for the elaboration of legislation.


Asunto(s)
Toxoplasma , Aguas Grises , Muestras de Agua , Oocistos
11.
Rev. cuba. med. trop ; 71(2): e399, mayo.-ago. 2019. graf
Artículo en Español | LILACS, CUMED | ID: biblio-1093565

RESUMEN

Introducción: Legionella pneumophila se sitúa entre los principales agentes causales de neumonía adquirida en la comunidad y de origen nosocomial. La inhalación de aerosoles potencialmente contaminados con la bacteria, producto de la colonización de redes y otros sistemas que utilizan agua, representa un peligro para la salud de los individuos expuestos. Objetivo: evaluar la viabilidad de L. pneumophila en muestras de agua almacenadas en diferentes intervalos de tiempo para el diagnóstico por cultivo microbiológico de Legionella spp. Métodos: Se contaminaron artificialmente muestras de agua con dos cepas de L. pneumophila de serogrupos diferentes y la conformación de una mezcla de ellas, para un total de 15 muestras. Los frascos contaminados fueron procesados a las 24 h, 72 h, 7 días, 14 días y 21 días. Se realizó cultivo microbiológico según ISO 11731: 2004 y PNO 03-013: 2015. Resultados: Se demostró viabilidad de la bacteria en muestras almacenadas hasta 21 días. El método de concentración por filtración resultó tener los mayores recobrados del microorganismo. Conclusiones: El tiempo de almacenamiento de las muestras afecta la viabilidad de L. pneumophila. Sienta las bases para estudios posteriores de robustez del diagnóstico de L. pneumophila como parte del servicio que presta el Centro de Investigaciones Científicas de la Defensa Civil en los programas de prevención y control Legionella spp. en instalaciones de interés turístico e industrial(AU)


Introduction: Legionella pneumophila is one of the main causative agents of community- and hospital-acquired pneumonia. Inhalation of sprays potentially contaminated with the bacterium, due to the colonization of networks and other systems using water, is a hazard to the health of exposed individuals. Objective: Evaluate the viability of L. pneumophila in samples of water stored at various time intervals for the microbiological culture diagnosis of Legionella spp. Methods: Water samples were artificially contaminated with two strains of L. pneumophila from different serogroups and a mixture of them, for a total of 15 samples. The contaminated vessels were processed at 24 h, 72 h, 7 d, 14 d and 21 d. Microbiological culture was performed in compliance with ISO 11731: 2004 and PNO 03-013: 2015. Results: The bacterium was found to be viable in samples stored up to 21 days. The filtration concentration method obtained the greatest amount of the microorganism. Conclusions: Storage time of the samples affects the viability of L. pneumophila. The study lays the foundations for further research about the validity of L. pneumophila diagnosis as part of the service offered by the Civil Defense Scientific Research Center in Legionella spp. prevention and control programs for tourist and industrial facilities(AU)


Asunto(s)
Humanos , Enfermedad de los Legionarios/inmunología , Muestras de Agua , Viabilidad Microbiana/inmunología , Neumonía/microbiología , Comunicación
12.
Rev. cuba. med. trop ; 71(1): e299, ene.-abr. 2019. tab, graf
Artículo en Inglés | LILACS, CUMED | ID: biblio-1093543

RESUMEN

Introduction: Intestinal parasitosis by helminths and protozoa is still today a global public health problem mainly affecting people living in conditions of social vulnerability, including rural communities. Objective: Describe human intestinal parasitosis and environmental contamination with helminths and protozoa in the Quilombola community of Quartel do Indaiá (of African descent) in the State of Minas Gerais, Brazil. Methods: A cross-sectional study was conducted of stool and soil samples by spontaneous sedimentation, and of plant samples by centrifugation sedimentation, to detect intestinal helminths and protozoa. Water samples were analyzed for total and fecal coliforms. Results: Helminths and protozoa were found in 45.5 percent of the people (n = 66). The species detected were Ascaris lumbricoides (18.2 percent), Entamoeba coli (18.2 percent), Endolimax nana (18.2 percent), ancylostoma (6.1 percent, Iodamoeba butschlii (4.6 percent), Giardia duodenalis (3 percent) and Trichuris trichiura (1.5 percent). More than one species were present in 19.7 percent of the samples. In 18 of the 39 sites sampled, the soil was contaminated with E. coli, E. nana, A. lumbricoides, I. butschlii and/or Enterobius vermicularis. Vegetables (n = 135) were contaminated in 75 samples with 7 of the 8 species analyzed. The contaminants were E. coli cysts, A. lumbricoides eggs and ancylostoma. All water samples were contaminated with total and fecal coliforms. Conclusions: The Quilombola community of Quartel do Indaiá had high levels of human infection and high environmental contamination with intestinal parasites or protozoa, probably due to lack of appropriate sanitary conditions. It is necessary to improve the access to treated water and sanitation(AU)


Introducción: El parasitismo intestinal por helmintos y protozoarios todavía es un problema de salud pública mundial, que afecta sobre todo personas en condiciones de vulnerabilidad social, incluso las comunidades rurales. Objectivo: Describir la infección humana y la contaminación ambiental por parásitos/comensales intestinales en una comunidade 'quilombola' Quartel do Indaiá (descendentes de esclavos) del Estado de Minas Gerais, Brasil. Métodos: Estudio de corte transversal con análisis de muestras fecales y de tierra por sedimentación espontánea, y de vegetales por sedimentación con centrifugación para detección de parásitos o comensales intestinales. Se analizaron muestras de agua para detección de coliformes totales y fecales. Resultados: Se observó la ocurrencia de parásitos o comensales en 45.5 por ciento de las personas (n = 66). Las especies detectadas fueron Ascaris lumbricoides (18,2 por ciento), Entamoeba coli (18,2 por ciento), Endolimax nana (18,2 por ciento), anquilostomas (6.1 por ciento), Iodamoeba butschlii (4,6 por ciento), Giardia duodenalis (3 por ciento), and Trichuris trichiura (1,5 por ciento). Para 19,7 por ciento de las muestras se detectaron más de una especie. El suelo estuvo contaminado en 18 de los 39 sitios muestreados, con presencia de E. coli, E. nana, A. lumbricoides, I. butschlii y/o Enterobius vermicularis. Los vegetales (n = 135) presentaron contaminación en 75 muestras de 7, entre 8 especies analizadas. Sus contaminantes fueron quistos de E. coli y huevos de A. lumbricoides y anquilostoma. Todas las muestras de agua estaban contaminadas por coliformes totales y fecales. Conclusiones: La comunidad 'quilombola' Quartel do Indaiá presentó alta infección humana y alta contaminación ambiental por parásitos o comensales intestinales, lo que se debe probablemente a la falta de condiciones sanitarias. Se necesita mejorar el acceso para agua tratada y estructuras de saneamiento(AU)


Asunto(s)
Humanos , Muestras de Agua , Características de la Residencia , Ascaris lumbricoides , Perfiles Sanitarios , Quistes , Contaminación Ambiental , Estudios Transversales
13.
Rev. argent. microbiol ; Rev. argent. microbiol;51(1): 72-76, mar. 2019. graf
Artículo en Español | LILACS | ID: biblio-1041817

RESUMEN

Este trabajo tuvo como objetivo evaluar el efecto de rotaciones arroceras sobre la población de cianobacterias durante el ciclo de cultivo. El estudio se condujo en Entre Ríos (Argentina). Se evaluaron cuatro rotaciones: arroz-soja (AS); arroz-soja-maíz-soja (ASMS): arroz-arroz (AA) y arroz-pradera (AP). Muestras de suelo y agua se tomaron en cuatro estados del cultivo: implantación, macollaje, panoja embuchada y madurez fisiológica. El número potencial de cianobacterias fue menor en relación a otras áreas arroceras. Los menores recuentos se registraron en el período de implantación y los mayores en el de panoja embuchada. El análisis estadístico no mostró efecto de las rotaciones sobre el número de cianobacterias, aunque AA presentó la mayor abundancia. Se reconocieron un total de 13 géneros de cianobacterias Lyngbya, Oscillatoria,Plectonema, Spirulina, Anabaena, Nostoc, Aulosira, Calothrix, Gloeotri-chia, Aphanocapsa,Croococcus, Mycrocystis y Gloeocapsa. La rotación AP registró la riqueza de géneros.Las rotaciones AS y AA presentaron mayor proporción de cianobacterias filamentosas. Los valores de biodiversidad de Simpson fueron bajos. Se concluyó que las rotaciones arroceras evaluadas tuvieron efecto sobre la proporción de cianobacterias unicelulares a filamentosas, los géneros presentes y la riqueza.


The aim of this study was to evaluate the effect of different rice rotations on cyanobacteria populations during the growing season. The study was conducted in Entre Ríos (Argentina). Four crop rotations were evaluated: rice-soybean (AS); rice-soybean-corn-soybean (ASMS); rice-rice (AA) and rice-pasture (AP). Soil and water samples were collected in 4 stages: implantation, tillering, booting and physiological maturity. The potential number of cyanobacteria population was lowerin relation to other rice sites previously reported. The lowest counts were recorded during implantation whereas the highest counts were obtained during booting. The statistical analysis showed no effect of rotation on the variable number of cyanobacteria, although AA was the most abundant. A total of 13 taxa were identified: Lyngbya, Oscillatoria, Plectonema, Spirulina, Anabaena, Nostoc, Aulosira, Calothrix, Gloeotrichia, Aphanocapsa, Croococcus, Mycrocystis and Gloeocapsa. AP rotation recorded the lowest number of genera. AS and AA had a higher proportion of filamentous cyanobacteria. Simpson's index was low. It was concluded that crop rotations had a differential effect on some aspects of cyanobacteria population such as the proportion of unicellular to filamentous cyanobacteria, genera presence and richness.


Asunto(s)
Cianobacterias/clasificación , Cianobacterias/crecimiento & desarrollo , Agricultura Sostenible , Oryza/microbiología , Muestras de Agua , Interpretación Estadística de Datos
14.
Semina cienc. biol. saude ; 40(2): 129-140, jun./dez. 2019. Tab, Ilus
Artículo en Portugués | LILACS | ID: biblio-1223869

RESUMEN

A água é indispensável à vida e a sua contaminação com microrganismos patogênicos oferece grande risco à saúde humana, podendo causar doenças que variam de gastroenterites brandas a doenças fatais. Dessa forma, a água para o consumo humano deve estar livre de microrganismos patogênicos e não deve conter bactérias indicadoras de contaminação fecal, sendo a Escherichia coli o principal representante desse grupo de bactérias. Tendo em vista a importância da potabilidade da água para a saúde, o presente trabalho teve por objetivo verificar a qualidade bacteriológica da água utilizada para o consumo humano proveniente de 200 poços artesianos localizados na cidade de Cambé/Paraná, no período de 2013 a 2017, utilizando-se para tanto a análise da presença de coliformes totais e de E. coli como indicador de contaminação fecal. A metodologia empregada para a pesquisa de coliformes totais e E. coli foi o método do substrato cromogênico Colilert®. Dentre as 200 amostras analisadas, 113 (56,5%) estavam contaminadas com coliformes totais e 35 (17,5%) com E. coli. As análises realizadas durante o período de cinco anos possibilitaram encontrar 14 (7%) amostras de água tratadas que apresentavam contaminação por bactérias do grupo coliforme. A partir dos resultados obtidos nesse trabalho, espera-se conscientizar tanto a população quanto os órgãos públicos sobre a importância do controle da qualidade da água para a prevenção de doenças transmitidas por esse meio (AU)


Water is essential for life and its contamination by pathogenic microorganisms offers great risk to human health and may cause illnesses ranging from mild gastroenteritis to life threatening diseases. Thus, water for human consumption should be free of pathogenic microorganisms and must not contain indicators of faecal contamination such as Escherichia coli presence. Given the importance of drinking water quality for health, this study aimed to verify the bacteriological quality of water used for human consumption from 200 artesian wells located in the city of Cambé - Paraná, from 2013 to 2017. The methodology used for the research of total coliforms and E. coli was the Colilert® chromogenic substrate method. Among the 200 analysed water samples, 113 (56.5%) were contaminated with total coliforms and 35 (17,5%) with E. coli. The analyses carried out during the five-year period allowed finding 14 (7%) treated water samples that showed contamination by bacteria of the coliform group. Based on the results obtained in this study, it is expected that both the population and the public agencies will be aware of the importance of water quality control for the prevention of diseases transmitted by this means (AU)


Asunto(s)
Humanos , Muestras de Agua , Escherichia coli , Coliformes , Pozos de Agua , Bacterias , Agua Potable , Salud , Contaminación Ambiental , Estudios Poblacionales en Salud Pública
15.
Rev. cuba. med. trop ; 70(3): 50-60, set.-dic. 2018. ilus, tab
Artículo en Español | LILACS, CUMED | ID: biblio-991105

RESUMEN

Introducción: Acanthamoeba y Naegleria son géneros de amebas de vida libre resistentes a cambios extremos de temperatura y pH, aislados de diversos ambientes (suelo, aire y agua). Debido a la cantidad de habitantes que se benefician de las aguas del Río Pamplonita, al desconocimiento de su presencia en la región y al aumento de enfermedades relacionadas con el consumo de agua, se considera necesario realizar estudios sobre la distribución de estos microorganismos. Objetivo: Identificar Acanthamoeba spp. y Naegleria spp. en aguas del curso principal del río Pamplonita de la zona metropolitana de Cúcuta, Colombia. Métodos: La búsqueda de las amebas de interés se realizó mediante examen directo y cultivo a 28, 37 y 42 °C en agar no nutritivo a partir de 21 muestras de agua de siete sectores del río Pamplonita. Adicionalmente, se midió pH y temperatura in situ y se determinó la carga de coliformes. Resultados: Se encontró que 76,2 por ciento de las muestras fueron positivas para alguna de las amebas. La Acanthamoeba fue la que se aisló con mayor frecuencia. El 28,6 por ciento de los cultivos incubados a 42 °C fueron positivos principalmente para Naegleria spp., lo que indica que estos aislados termotolerantes podrían tener potencial patógeno. Conclusiones: Acanthamoeba spp. y Naegleria spp. son frecuentes en aguas del Río Pamplonita en áreas de importante intervención humana. El hallazgo de amebas termotolerantes alerta sobre el riesgo de salud para la población que se encuentra expuesta a esta fuente hídrica(AU)


Introduction: Acanthamoeba and Naegleria are genus of free-living amoeba (AVL) resistant to extreme changes in temperature and pH, isolated from different environments (soil, air and water). Due to the number of inhabitants that benefit from the waters of Pamplonita River, the lack of knowledge about its presence in the region and the increase of diseases related to water consumption, it is necessary to carry out studies on its distribution. Objective: To identify Acanthamoeba spp and Naegleria spp in the water of the main course of Pamplonita River, in the metropolitan area of Cúcuta, Colombia. Methods: The search for the amoebas of interest was performed by direct examination and culture at 28, 37 and 42 °C on non-nutritive agar from 21 water samples from seven sectors of Pamplonita River. Additionally, pH and temperature were measured in situ and the coliforms´ load was also determined. Results: It was found that 76.2 percent of the samples were positive for some of the amoebas, with Acanthamoeba being the most frequently isolated. 28.6 percent of the cultures incubated at 42 °C were positive mainly for Naegleria spp, indicating that these thermotolerant isolates could have pathogen potential. Conclusions: Acanthamoeba spp and Naegleria spp are frequent in waters of Pamplonita River which are areas of important human intervention. The finding of thermotolerant amoebas warns about the health risk for the population that is exposed to this water source(AU)


Asunto(s)
Naegleria/microbiología , Muestras de Agua , Amebiasis/microbiología , Contaminación de Ríos/efectos adversos , Epidemiología Descriptiva , Estudios Transversales , Colombia
16.
Rev. cuba. med. trop ; 70(1): 0-0, ene.-abr. 2018. ilus, tab
Artículo en Inglés | LILACS, CUMED | ID: biblio-1042915

RESUMEN

Feces-contaminated water is a vehicle of transmission of potentially pathogenic microorganisms responsible for illnesses that represent main causes of death worldwide. A protocol for detection of intestinal parasites in great volumes of water was optimized. It includes: membrane filtration, mechanical agitation with detergent, centrifugation, chemical concentration with Mini Parasep® and microscopic examination. From samples of feces-contaminated water containing parasitic forms, a total recovery percentage of 85.7 percent of parasites was achieved after tests. This procedure provides a useful alternative method that could be subjected to validation as a routine methodology in the diagnosis of microbiological water quality(AU)


El agua contaminada con heces es un vehículo de transmisión de microorganismos potencialmente patógenos causantes de enfermedades que constituyen causas principales de muerte a nivel mundial. Se optimizó un protocolo para la detección de parásitos intestinales en grandes volúmenes de agua. Este incluye: filtración por membrana, agitación mecánica con detergente, centrifugación, concentración química con Mini Parasep® y examen microscópico.En muestras de agua contaminada con heces que contenían formas parasitarias, se obtuvo un porcentaje de recuperación total del 85.7 por ciento de estas formas después de aplicar el protocolo. El procedimiento constituye un método alternativo que podría someterse a validación como metodología habitual para el diagnóstico de la calidad microbiológica del agua(AU)


Asunto(s)
Humanos , Contaminación del Agua/análisis , Calidad del Agua , Muestras de Agua , Causas de Muerte , Heces/parasitología
17.
Hig. aliment ; 32(278/279): 92-96, 30/04/2018.
Artículo en Portugués | LILACS | ID: biblio-909983

RESUMEN

A falta de estruturas adequadas para o fornecimento de água potável é uma das principais causas de contaminação por micro-organismos patogênicos. Uma vez que nas instituições de ensino, esta água é utilizada para o preparo de alimentos e consumo das crianças, sua contaminação torna-se um perigo para a saúde humana constituindo assim uma ameaça à saúde pública. Este trabalho teve como objetivo pesquisar a presença de coliformes totais e termotolerantes na água das cozinhas e bebedouros em creches da rede municipal de ensino de Teixeira de Freitas, BA. Foram realizadas 32 amostras de água, coletadas diretamente da torneira da cozinha e do bebedouro das creches. A pesquisa foi realizada, através da técnica do Número Mais Provável (NMP), de coliformes totais e termotolerantes, além de testes bioquímicos para isolamento e identificação de Escherichia coli. Das amostras de água analisadas 11 (34,4%) estavam contaminadas por coliformes totais e uma (3,1%) com presença de coliformes termotolerantes, sendo esta uma amostra de água do bebedouro.(AU)


The lack of proper structures to supply drinking water is one of the main causes of contamination with pathogenic microorganisms. Since this water is used to prepare food for students in schools, such contamination represents a health hazards, becoming a threat to public health. This study investigated the presence of total and thermotolerant coliforms in the water used in kitchens and dispensed in water coolers in day care units in the municipal education network of Teixeira de Freitas, Bahia, Brazil. In total, 32 water samples were collected directly from the kitchen tap and water coolers. Thermotolerant and total coliforms counts were obtained using the Most Probable Number method, in addition to biochemical assays to isolate and identify Escherichia coli. Eleven (33.4%) samples were contaminated with total coliforms, while one (3.1%) sample collected from a water cooler had thermotolerant coliforms.


Asunto(s)
Humanos , Preescolar , Microbiología del Agua , Agua Potable/microbiología , /análisis , Coliformes , Brasil , Muestras de Agua , Guarderías Infantiles , Escherichia coli/aislamiento & purificación , Método de Tubos Múltiples
18.
Hig. aliment ; 32(276/277): 108-112, fev. 27, 2018.
Artículo en Portugués | LILACS | ID: biblio-884014

RESUMEN

[{"text": "Este trabalho objetivou avaliar a\r\ninfluência da cloração da água utilizada\r\nna higienização de tanques de\r\nexpansão na contagem de Escherichia\r\ncoli e Pseudomonas sp. do leite\r\ncru refrigerado. Amostras de leite cru\r\ne de água de18 tanques de expansão\r\nforam avaliadas por um ano, sendo\r\nque em 9 tanques não havia sistema\r\nde cloração da água implantado no\r\ndecorrer de 12 meses e nos outros\r\n9, por 6 meses não houve cloração\r\nda água e nos 6 meses seguintes o\r\nsistema foi implantado. Para determinação\r\nde E. coli no leite cru e na\r\nágua utilizou-se a técnica do Número\r\nMais Provável (NMP) e para\r\na contagem de Pseudomonas sp.\r\nutilizou-se Ágar Para Isolamento de\r\nPseudomonas (PIA). Constataram-\r\n-se valores médios de 1,5NMP/mL e\r\n1,6NMP/mLde E. coli no leite e na\r\nágua, respectivamente, nas amostras\r\nprovenientes dos 9 tanques em que a\r\nágua utilizada não foiclorada por 12\r\nmeses. As amostras de leite e água\r\nprocedentes dos 9 tanques que receberam\r\nágua clorada durante a limpeza\r\npor 6 meses apresentaram em média\r\n1,8NMP/mL e < 1,1 NMP/mL de\r\nE.coli, respectivamente. A contagem\r\nmédia de Pseudomonas sp. nas amostras\r\nde água procedentes dos 9 tanques\r\nem que a água utilizada no processo\r\nde limpeza não recebeu cloração por\r\n6 meses e que posteriormente passou\r\na ser clorada foi 1,1x103UFC/mL e\r\n1,2x102UFC/mL, respectivamente.\r\nPor outro lado,amédia das contagens\r\nde Pseudomonas sp. foi de 9,8x104\r\nUFC/mL e 5,1x105 UFC/mL nas\r\namostras de leite procedentes dos tanques\r\nem que a água utilizada no processo\r\nde limpeza não recebeu cloração\r\npor 6 meses e que posteriormente\r\npassou a ser clorada, respectivamente,\r\no que indica que esta bactéria acessa o\r\nleite cru a partir de diferentes fontes\r\nde contaminação, além da água. Assim,\r\na cloração foi eficiente apenas\r\nna redução da contagem de E. coli e\r\nPseudomonas sp. na água.(AU)", "_i": "pt"}]


Asunto(s)
Humanos , Muestras de Agua , Cloro/análisis , Desinfección del Agua/métodos , Leche/microbiología , Almacenamiento de Alimentos , Pseudomonas/aislamiento & purificación , Industria Lechera , Escherichia coli/aislamiento & purificación , Control de la Contaminación del Agua
19.
Braz. arch. biol. technol ; Braz. arch. biol. technol;61: e18160777, 2018. tab, graf
Artículo en Inglés | LILACS | ID: biblio-974113

RESUMEN

ABSTRACT This study aims to specify the amount of ten heavy metals (Al, Cr, Mn, Ni, Cu, Zn, As, Cd, Hg, Pb) in water, sediment and Enteromorpha intestinalis samples gathered from Kadin Creek in seasonal periods in 2011 and 2012 and to reveal bioaccumulation capability of this macrophytic algae. In this regard, heavy metal concentrations in the gathered samples were determined first with mineralization and then via inductively coupled plasma mass spectroscopy (ICP-MS) method. Findings suggested that algae could be used as an indicator in freshwater ecosystems in terms of studied heavy metals. With regard to bioconcentration factor values, in terms of water, algae accumulated aluminum the most and cadmium the least (Al > Cu > As > Zn > Cr > Mn > Ni > Pb > Hg > Cd), in terms of sediment, it accumulated mercury the most and aluminum the least (Hg > Cd > As > Zn > Pb > Mn > Ni > Cr > Cu > Al). The highest rate of heavy metal concentration in algae was observed in summer when contaminants in water and dynamics of plant development increased. It was also observed that the mean mercury and cadmium concentrations exceeded the maximum residue limit values.


Asunto(s)
Algas Marinas , Muestras de Agua , Metales Pesados/análisis , Bioacumulación
20.
Rev. Inst. Adolfo Lutz (Online) ; 77: e1744, 2018. ilus, map, graf
Artículo en Portugués | LILACS, VETINDEX | ID: biblio-1489568

RESUMEN

As condições de coleta e o transporte das amostras de água tratada para uso em diálise são etapas críticas para garantir a qualidade dos resultados analíticos. A temperatura no transporte de amostras deve assegurar a manutenção das características físicas e biológicas desde a coleta até o recebimento pelo laboratório analítico. O objetivo deste estudo foi de qualificar o transporte de amostras de água tratada para diálise desde os Serviços de Diálise do estado de São Paulo até o Instituto Adolfo Lutz, realizado durante a execução do Programa Estadual de Monitoramento. Os resultados obtidos indicaram que o sistema adotado, utilizando-se caixas isotérmicas e gelo reutilizável, é capaz de garantir as condições adequadas de temperatura durante o transporte do ponto de coleta das amostras até o laboratório analítico.


The conditions for collecting and transporting the dialysis water samples are the critical steps to assure the quality of the analytical results. The temperature during the water samples transport should ensure the maintenance of the physical and biological characteristics of samples from their collections to the analytical laboratory. The objective of this study was to qualify the transport of the dialysis water samples from the Dialysis Services of the state of São Paulo to the Adolfo Lutz Institute, during the performance of the State Monitoring Program. By using the isothermal boxes and the reusable ices, the obtained results indicated that the adopted system were able to guarantee the adequate temperature conditions during the transport from the sample collection point to the analytical laboratory.


Asunto(s)
Muestras de Agua , Control de la Calidad del Agua , Monitoreo del Agua , Preservación de Muestras de Agua/métodos , Diálisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA