Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Braz. oral res. (Online) ; 30(1): e40, 2016. tab, graf
Artículo en Inglés | LILACS | ID: biblio-952021

RESUMEN

Abstract The fit of the implant-abutment interface was assessed by the metallographic technique and by scanning electron microscopy (SEM), using solid abutment types at different torque levels. Forty Morse taper connections and forty solid abutments were used at different torque levels (repeated after 10 minutes) in the following groups (n = 10): 25 Ncm (group g1), 30 Ncm (group g2), 35 Ncm (group g3), and 40 Ncm (group g4). The samples were embedded in a metallographic resin, sectioned lengthwise, and polished. SEM images were used to measure the linear contacts and the fits between abutments and the internal walls of the implant. The overall mean gap and standard deviation were as follows: 9.0 ± 1.36 µm for group g1, 7.9 ± 2.81 µm for group g2, 2.0 ± 0.76 µm for group g3, and 0.3 ± 0.40 µm for group g4. A significant difference was observed in the average fit values between the groups (p < 0.05). The linear area of contact between the abutment and the implant increased as torque augmented. This study demonstrated that higher insertion torque values in a conical internal connection increase the fit (contact) of the implant-abutment interface.


Asunto(s)
Implantes Dentales/normas , Pilares Dentales/normas , Torque , Implantación Dental Endoósea/métodos , Diseño de Implante Dental-Pilar/métodos , Estándares de Referencia , Tornillos Óseos , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Análisis de Varianza , Soporte de Peso
2.
Artículo en Inglés | IMSEAR | ID: sea-139765

RESUMEN

Objectives: The dual-arch impression technique is convenient in that it makes the required maxillary and mandibular impressions, as well as the inter-occlusal record in one procedure. The accuracy of inter-abutment distance in dies fabricated from dual-arch impression technique remains in question because there is little information available in the literature. Materials and Methods: This study was conducted to evaluate the accuracy of inter-abutment distance in dies obtained from full arch dual-arch trays with those obtained from full arch stock metal trays. Results and Conclusion: The metal dual-arch trays showed better accuracy followed by the plastic dual-arch and stock dentulous trays, respectively, though statistically insignificant. The pouring sequence did not have any effect on the inter-abutment distance statistically, though pouring the non-working side of the dual-arch impression first showed better accuracy.


Asunto(s)
Aleaciones , Diente Premolar , Pilares Dentales/normas , Articuladores Dentales , Materiales de Impresión Dental/química , Técnica de Impresión Dental/instrumentación , Técnica de Impresión Dental/normas , Modelos Dentales/normas , Oclusión Dental Céntrica , Diseño de Dentadura/normas , Dentadura Parcial Fija , Diseño de Equipo , Humanos , Registro de la Relación Maxilomandibular/instrumentación , Registro de la Relación Maxilomandibular/métodos , Diente Molar , Plásticos , Polivinilos/química , Siloxanos/química , Propiedades de Superficie
3.
Rev. ADM ; 58(1): 10-5, ene.-feb. 2001. ilus
Artículo en Español | LILACS | ID: lil-288835

RESUMEN

Los tratamientos de sobredentaduras están tomando cada vez más auge debido a que la población tiene una mayor educación respecto a su salud oral, además de que los odontólogos están mejor capacitados para realizar este tipo de tratamiento. En este artículo se pretende ilustrar las diferentes opciones de aditamentos que se tienen para aumentar la retención y estabilidad de la dentadura y se presentan las características de los aditamentos Preci-ball son fáciles de conseguir, sus procedimientos clínicos y de laboratorio son sencillos y rápidos, son maquinados en aleación oro o paladio y limpiados fácilmente


Asunto(s)
Humanos , Femenino , Persona de Mediana Edad , Retención de Prótesis Dentales , Prótesis de Recubrimiento/normas , Ajuste de Precisión de Prótesis/normas , Pilares Dentales/normas , Pins Dentales
4.
Rev. bras. odontol ; 56(5): 234-8, set.-out.1999. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-255889

RESUMEN

Um dos problemas que ocorrem no emprego dos implantes está associado ao afrouxamento das conexöes, devido à falta de ajuste entre o sextavado do implante e do abutment. Uma das causas do desajuste tem sido a variaçäo dimensional e a näo ocorrência de intercambialidade das peças. Neste trabalho, fez-se a análise estatística das dimensöes de implantes Master Screw e comparou-se os resultados com dimensöes dos implantes Ster-Oss, Lifecore e Calcitek existentes na literatura. Os resultados mostraram que os implantes Master Screw possuem tolerância dimensionais equivalentes a dos implantes importados, o que permite boa ajustagem com os abutments e possibilidade de reduzir o afrouxamento dos sistemas


Asunto(s)
Pilares Dentales/normas , Implantes Dentales/normas , Retención de Prótesis Dentales/instrumentación , Retención de Prótesis Dentales/métodos , Tecnología Odontológica , Resistencia a la Tracción
7.
Rev. Fac. Odontol. (Córdoba) ; 23/25(1/2): 35-42, ene. 1995-dic. 1997. ilus
Artículo en Español | LILACS | ID: lil-217127

RESUMEN

Se realiza un estudio comparativo entre los pilares cónicos paralelizables de base externa, pilares angulados prefabricados y pilares angulados colados, obtenidos a partir del material calcinable. Los pilares cónicos paralelizables, de base externa se caracterizan por su diseño logrado por método directo, directo-indirecto o indirecto, consiguiendo una personalización en su emergencia y angulación óptima del sector a reponer con indicaciones precisas para el sector superior. Consigue una perfecta adaptación de 2 superficies maquinadas enfrentadas o en contacto, evitando corrosión galvánica y efectos similares en los tejidos blandos. Su construcción y conformación de una sola pieza evita problemas de fatiga e imperfección del metal por colado


Asunto(s)
Humanos , Pilares Dentales/normas , Implantación Dental Endoósea/métodos , Prótesis Dental de Soporte Implantado/métodos , Técnica de Colado Dental , Dentadura Parcial Fija/normas , Diseño de Dentadura/métodos
8.
Rev. Asoc. Odontol. Argent ; 85(5): 458-66, oct.-dic. 1997. ilus, tab
Artículo en Español | LILACS | ID: lil-211688

RESUMEN

Se efectúa una valorización matemática de la utilización de implantes como pilares para la solución de los diferentes casos clínicos que se pueden presentar en implantología oseointegrada. Para solucionarlos se enuncian 1 regla y 2 norma que contemplan todas las alternativas en bocas parcialmente desdentadas. En edéntulos totales se dicta 1 regla. El uso de cantilevers en implantología está regido por 4 reglas


Asunto(s)
Humanos , Pilares Dentales/normas , Implantación Dental Endoósea/métodos , Oseointegración/fisiología , Proceso Alveolar , Proceso Alveolar/anatomía & histología , Densidad Ósea , Densitometría , Arcada Edéntula , Arcada Edéntula/rehabilitación , Prótesis Dental de Soporte Implantado/normas , Radiografía Panorámica/métodos , Titanio/química , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA