Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Indian J Med Sci ; 2011 Jan; 65(1) 26-31
Artículo en Inglés | IMSEAR | ID: sea-145585

RESUMEN

Background: Diagnosis of malaria is usually made by microscopy [Giemsa, Acridine Orange (AO), and Quantitative Buffy Coat (QBC) assay], which requires expertise. Currently, automated haematology analyzers are being used for complete blood count (CBC), in all acute febrile and non-febrile illnesses which simultaneously detects malaria. The normal scattergram by the analyzer (Sysmex 2100) comprises of five parameters i.e. lymphocytes (pink), monocytes (green), neutrophils (blue), eosinophils (red) with a space between the neutrophil and eosinophil populations. Aims : We carried out a prospective study to compare the efficacy of Sysmex XE-2100 (Sysmex Corporation, Kobe) for detection of malaria in comparison to other conventional techniques. Materials and Methods : 430 cases were analyzed for malaria by microscopy (QBC, AO, Giemsa), ICT (Immunochromatography) and flowcytometric analyzer (Sysmex XE-2100). The abnormal scattergrams were observed as double neutrophil, double eosinophil, grey zone, extended neutrophil zone with a decrease space between eosinophil and neutrophil, and a combination of above patterns. Results : Out of 70 positive cases [49/70 (70%) P. vivax, 18/70 (25.7%) P. falciparum, and 3/70 (4.2%) both P. vivax and P. falciparum], 52 showed abnormal scattergrams by the analyzer. The sensitivity and specificity of hematology analyzer found to be 74.2% and 88%, respectively. Conclusion : Flowcytometric analyzer is a rapid, high throughput device which needs less expertization for the diagnosis of malaria. Hence, it can be used in the diagnostic laboratories as an early modality for diagnosis of malaria in suspected as well as clinically in apparent cases.


Asunto(s)
Autoanálisis/instrumentación , Recuento de Células Sanguíneas/instrumentación , Citometría de Flujo/instrumentación , Pruebas Hematológicas/instrumentación , Humanos , Malaria/diagnóstico , Malaria Falciparum/diagnóstico , Malaria Vivax/diagnóstico , Plasmodium falciparum/análisis , Plasmodium vivax/análisis , Sensibilidad y Especificidad
2.
Rev. Inst. Med. Trop. Säo Paulo ; 36(2): 157-62, mar.-abr. 1994. tab
Artículo en Inglés | LILACS | ID: lil-140156

RESUMEN

Mais de 500.000 casos novos de malaria foram notificados no Brasil, em 1992. P. falciparum and P. vivax sao as especies responsaveis por 99,3 por cento dos casos. O diagnostico precoce e indispensavel para inicio do tratamento adequado. Neste trabalho, apresentamos or resultados do metodo tradicional para a deteccao de plasmodios, gota espessa, e os resultados de metodos alternativos estudados: imunofluorescencia indireta com anticorpo policlonal anti-P. falciparum e QBC-metodo, em grupos populacionais bem definidos....


Asunto(s)
Técnica del Anticuerpo Fluorescente , Malaria/diagnóstico , Brasil , Malaria/epidemiología , Plasmodium falciparum/análisis , Plasmodium vivax/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA