Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
1.
Braz. dent. j ; 26(2): 156-159, Mar-Apr/2015. tab, graf
Artículo en Inglés | LILACS | ID: lil-741211

RESUMEN

The aim of this study was to evaluate the compressive resistance under oblique loads of abutments with two different diameters and transmucosal heights used for cement-retained implant-supported prostheses in Morse-taper implants. Forty Morse-taper implants were divided into four groups with different abutment sizes for cement-retained prostheses in order to perform the compressive test. The groups were divided by abutment diameter and transmucosal height as follows: Group 1: 4.5 x 2.5 mm; Group 2: 4.5 x 3.5 mm; Group 3: 3.3 x 2.5 mm; and Group 4: 3.3 x 3.5 mm. An oblique compressive loading test was performed on each sample located in a platform at 30° using a universal testing machine with a load cell of 1,000 kgf and 0.5 mm/min speed until achieving the deformation of abutment's neck. The compressive resistance and its mechanical behavior were recorded for each group and the data were analyzed using ANOVA, the Shapiro-Wilk and Scheffé tests. In addition, the detailed damage of all samples was recorded with a conventional camera linked to the endoscopic equipment. Significant differences were observed among the groups, except between Groups 2 and 3 (p>0.005). All the abutments showed permanent deformations in the upper region and at the transmucosal portion, but the threads of the screws were intact. Fractures were only identified in Groups 3 and 4. Stronger mechanical behavior and compressive resistance was observed in the abutments with 4.5 mm diameter and 2.5 mm transmucosal height.


O objetivo deste estudo foi avaliar a resistência compressiva sob carga oblíqua em pilares com dois diferentes diâmetros e alturas de transmucoso usados para prótese implanto-suportada cimentada em implantes de cone Morse. Quarenta implantes de cone morse foram divididos em quatro grupos com diferentes tamanhos de pilares para próteses cimentadas a fim de realizar o teste compressivo. Os grupos foram divididos pelo diâmetro do pilar e altura de transmucoso como segue: 1) 4,5 x 2,5 mm; 2) 4,5 x 3,5 mm; 3) 3,3 x 2,5 mm; e 4) 3,3 x 3,5 mm. Um ensaio de compressão oblíqua foi realizado em cada amostra localizada numa plataforma a 30º utilizando uma máquina de ensaios universal, com célula de carga de 1.000 kgf e 0,5 mm/min de velocidade até atingir a deformação do pescoço do pilar. A resistência compressiva e seu comportamento mecânico foram registrados para cada grupo e os dados foram analisados utilizando os testes Shapiro-Wilk, ANOVA e Scheffé. Além disso, a deformação detalhada de todas as amostras foi registrada com uma câmera convencional conectada ao equipamento endoscópico. Foram observadas diferenças significativas entre os grupos, com exceção dos Grupos 2 e 3 (p>0,005). Todos os pilares mostraram deformação permanente na região superior e na porção transmucosa; porém, as roscas dos parafusos estavam intactas. Fraturas foram apenas identificadas nos Grupos 3 e 4. Foi observado melhor comportamento mecânico e resistência compressiva nos pilares com diâmetro de 4,5mm e altura de transmucoso de 2,5mm.


Asunto(s)
Pilares Dentales , Diseño de Implante Dental-Pilar , Prótesis Dental de Soporte Implantado , Cementos Dentales , Diseño de Prótesis Dental/instrumentación , Retención de Prótesis Dentales/instrumentación , Análisis del Estrés Dental , Ensayo de Materiales , Estrés Mecánico
2.
Braz. dent. j ; 24(6): 635-641, Nov-Dec/2013. tab, graf
Artículo en Inglés | LILACS | ID: lil-697668

RESUMEN

The purpose of this study was to assess the influence of the crown height of external hexagon implants on the displacement and distribution of stress to the implant/bone system, using the three-dimensional finite element method. The InVesalius and Rhinoceros 4.0 softwares were used to generate the bone model by computed tomography. Each model was composed of a bone block with one implant (3.75x10.0 mm) with external hexagon connections and crowns with 10 mm, 12.5 mm and 15 mm in height. A 200 N axial and a 100 N oblique (45°) load were applied. The models were solved by the NeiNastran 9.0 and Femap 10.0 softwares to obtain the results that were visualized by maps of displacement, von Mises stress (crown/implant) and maximum principal stress (bone). The crown height under axial load did not influence the stress displacement and concentration, while the oblique loading increased these factors. The highest stress was observed in the neck of the implant screw on the side opposite to the loading. This stress was also transferred to the crown/platform/bone interface. The results of this study suggest that the increase in crown height enhanced stress concentration at the implant/bone tissue and increased displacement in the bone tissue, mainly under oblique loading.


A proposta deste estudo foi avaliar a influência da altura da coroa de implantes de hexágono externo sobre o deslocamento e distribuição de tensões para o sistema implante/osso utilizando o método de elementos finitos. Os softwares InVesalius e Rhinoceros 4.0 foram usados para gerar o modelo de osso por meio de uma tomografia computadorizada. Cada modelo foi composto de um bloco ósseo com um implante (3.75 x 10.0 mm) com conexão de hexágono externo e coroas de 10 mm, 12.5mm e 15 mm em altura. Uma carga axial de 200 N e oblíqua (45°) de 100 N foram aplicadas. Os modelos foram resolvidos pelo software NeiNastram 9.0 e Femap 10.0 para obtenção dos resultados que foram visualizados por meio de mapas de deslocamento, de von Mises (coroa/implante) e tensão máxima principal (osso). A altura da coroa sob carga axial não influenciou o deslocamento e concentração de tensões, enquanto que a carga oblíqua aumentou a ação destes fatores. A maior concentração de tensões foi observada no pescoço do parafuso do implante no lado oposto à aplicação de carga. Esta tensão foi transferida para a interface coroa/plataforma/interface óssea. Os resultados deste estudo sugerem que o aumento da coroa amplia a concentração de tensões no tecido ósseo/implante, aumentando o deslocamento no tecido ósseo, principalmente sob carga oblíqua.


Asunto(s)
Coronas , Implantes Dentales , Modelos Dentales , Prótesis Dental de Soporte Implantado , Retención de Prótesis Dentales/instrumentación , Análisis del Estrés Dental/métodos , Fenómenos Biomecánicos , Aleaciones Dentales , Diseño de Prótesis Dental , Análisis de Elementos Finitos , Programas Informáticos , Tomografía Computarizada por Rayos X
3.
Artículo en Inglés | IMSEAR | ID: sea-145790

RESUMEN

Objectives: Biomechanics is one of the main factors for achieving long-term success of implant supported prostheses. Long-term failures mostly depend on biomechanical complications. It is important to distinguish the effects of macro design of the implants. Materials and Methods: In this study, the photoelastic response of four different types of implants that were inserted with different angulations were comparatively analyzed. The implant types investigated were screw cylinder (ITI, Straumann AG, Basel, Switzerland), stepped cylinder (Frialit2, Friadent GmbH, Manheim, Germany), root form (Camlog Rootline, Alatatec, Wilshelm, Germany), and cylindrical implant, with micro-threads on the implant neck (Astra, AstraTech, Mölndal, Sweden). In the test models, one of the implants was inserted straight, while the other one was aligned mesially with 15° angles. The superstructures were prepared as single crowns. A 150N loading was applied to the restorations throughout the test. Results: A comparison of the implant designs showed that there were no significant differences between the straight implants; however, between the inclined implants, the most favorable stress distribution was seen with the stepped cylinder implants. The least favorable stress concentration was observed around the root formed implants. Microthreads around the implant neck appeared to be effective in a homogenous stress distribution. Observations showed that misaligned implants caused less stress than straight implants, but the stress concentrations were not homogenous. Conclusion: As there were observable differences between the implant types, straight placed cylindrical implants showed better stress distribution characteristics, while inclined tapering implants had better stress distribution characteristics.


Asunto(s)
Fenómenos Biomecánicos/instrumentación , Fenómenos Biomecánicos/métodos , Implantes Dentales , Diseño de Implante Dental-Pilar/métodos , Porcelana Dental , Diseño de Prótesis Dental , Retención de Prótesis Dentales/instrumentación , Prótesis Dental de Soporte Implantado , Análisis del Estrés Dental/instrumentación , Análisis del Estrés Dental/métodos , Estrés Mecánico
4.
Braz. dent. j ; 22(1): 51-55, 2011. ilus, tab
Artículo en Inglés | LILACS | ID: lil-582402

RESUMEN

This study evaluated the loss of the torque applied after use of new screws and after successive tightening. Four infrastructures (IE), using UCLA castable abutment type, were cast in cobalt-chromium alloy and new abutment screws (G1) were used in a first moment. Subsequently, the same abutment screws were used a second time (G2) and more than two times (G3). The values of the torques applied and detorques were measured with a digital torque wrench to obtain the values of initial tightening loss ( percent). Data were analyzed by ANOVA and Tukey's test (?=0.05). Significant differences were observed between the G1 (50.71 percent ± 11.36) and G2 (24.01 percent ± 3.33) (p=0.000) and between G1 (50.71 percent ± 11.36) and G3 (25.60 percent ± 4.64) (p=0.000). There was no significant difference between G2 and G3 (p=0.774). Within the limitations of the study, it may be concluded that the percentage of the initial torque loss is lower when screws that already suffered the application of an initial torque were used, remaining stable after application of successive torques.


O objetivo deste estudo foi avaliar a perda do torque inicial, quando usados novos parafusos de pilares e após sucessivos apertos. Quatro infra-estruturas (IE), utilizando pilares calcináveis tipo UCLA, foram fundidas em liga de cobalto-cromo, onde novos parafusos de pilares foram utilizados (G1) em um primeiro momento. Posteriormente os mesmos parafusos de pilares foram utilizados em um segundo momento (G2), e depois por mais duas vezes (G3). Os valores de torque e detorque aplicados foram mensurados a partir de um torquímetro digital para obtenção dos valores de perda do torque inicial ( por cento). Os dados foram coletados e submetidos à análise de variância e teste de Tukey (p<0,05). Foram observadas diferenças estatisticamente significantes entre os grupos G1 (50,71 por cento ± 11,36) and G2 (24,01 por cento ± 3,33) (p=0,000) and the groups G1 (50,71 por cento ± 11,36) and G3 (25,60 por cento ± 4,64) (p=0,000). Os maiores valores foram encontrados para o grupo G1. Não houve diferença estaticamente significante entre os grupos G2 e G3 (p=0,774). Dentro das limitações deste estudo, pôde-se observar que a porcentagem de perda de torque inicial foi menor quando os parafusos já haviam sofrido a aplicação do primeiro torque, se mantendo estáveis após os demais torques.


Asunto(s)
Humanos , Pilares Dentales , Implantes Dentales , Fracaso de la Restauración Dental , Retención de Prótesis Dentales/instrumentación , Aleaciones de Cromo , Cobalto , Modelos Dentales , Análisis del Estrés Dental , Equipo Reutilizado , Mandíbula , Torque
5.
Artículo en Inglés | IMSEAR | ID: sea-139870

RESUMEN

This article describes the immediate placement and loading of implants in the aesthetic zone using an implant-retained, fixed prosthesis with a modified design. One section of the implant prosthesis has cemented crowns and the other section is the conventional screw-retained. This combined approach significantly offsets the unsuitable implant position, alignment or angulation, while ensuring the easy retrievability, repair and maintenance of the prosthesis at the same time.


Asunto(s)
Coronas , Implantación Dental Endoósea/métodos , Diseño de Prótesis Dental , Retención de Prótesis Dentales/instrumentación , Prótesis Dental de Soporte Implantado , Dentadura Parcial Fija , Dentadura Parcial Inmediata , Humanos , Arcada Parcialmente Edéntula/rehabilitación , Masculino , Maxilar/cirugía , Persona de Mediana Edad , Factores de Tiempo
6.
Artículo en Inglés | IMSEAR | ID: sea-139734

RESUMEN

Background: Posts and cores are often required for restoration of pulpless teeth and to provide retention and resistance for a complete crown, but conventional posts may increase the root fracture. Objective: This study was performed to compare the root fracture resistance of extracted teeth treated with different fibers reinforced with composite posts and treated teeth with conventional post and core systems. Materials and Methods: Root canal therapy was performed for 50 mandibular first premolars. The coronal portion of each tooth was amputated, and five post and core systems (cast, polyethylene woven, glass, carbon, and quartz fiber posts) were compared. Acrylic resin blocks were used for mounting, using a layer of elastomeric impression material covering the roots. The load was applied axially and measured with a universal testing machine. Results and Conclusion: Significantly, cast posts and cores had a higher failure threshold including teeth fracture; whereas, fiber posts failure was due to core fracture, with or without fractures in coronal portion of posts. Difference in FRC posts did not provide any significant difference in the load failure and the mode of fracture.


Asunto(s)
Análisis de Varianza , Diente Premolar , Resinas Compuestas/química , Coronas , Materiales Dentales/química , Diseño de Prótesis Dental , Retención de Prótesis Dentales/instrumentación , Fracaso de la Restauración Dental , Análisis del Estrés Dental , Humanos , Mandíbula , Ensayo de Materiales , Técnica de Perno Muñón/efectos adversos , Técnica de Perno Muñón/instrumentación , Tratamiento del Conducto Radicular/instrumentación , Estadísticas no Paramétricas , Fracturas de los Dientes/etiología , Raíz del Diente/lesiones , Diente no Vital/complicaciones
7.
Braz. dent. j ; 19(4): 358-363, 2008. ilus, tab
Artículo en Inglés | LILACS | ID: lil-504201

RESUMEN

This study investigated whether there is a direct correlation between the level of vertical misfit at the abutment/implant interface and torque losses (detorque) in abutment screws. A work model was obtained from a metal matrix with five 3.75 x 9 mm external hex implants with standard platform (4.1 mm). Four frameworks were waxed using UCLA type abutments and one-piece cast in commercially pure titanium. The misfit was analyzed with a comparator microscope after 20 Ncm torque. The highest value of misfit observed per abutment was used. The torque required to loose the screw was evaluated using a digital torque meter. The torque loss values, measured by the torque meter, were assumed as percentage of initial torque (100 percent) given to abutment screws. Pearson's correlation (α=0.05) between the misfit values (29.08 ± 8.78 µm) and the percentage of detorque (50.71 ± 11.37 percent) showed no statistically significant correlation (p=0.295). Within the limitations of this study, it may be concluded that great vertical misfits dot not necessarily implies in higher detorque values.


Este trabalho teve como objetivo correlacionar o nível de desajuste vertical pilar/implante a perda do torque aplicado (destorque). Um modelo de trabalho foi obtido a partir de uma matriz metálica com cinco implantes tipo hexágono externo (Titamax, Neodent, Curitiba, Brasil) com plataforma regular (4,1 mm). Sobre esta matriz, quatro infra-estruturas foram enceradas utilizando pilares tipo UCLA e fundidas em monobloco com titânio comercialmente puro (Tritan grau I, Dentaurum, Alemanha). Os desajustes foram analisados com um microscópio óptico comparador (Mytutoyo, Japão) após torque de 20 Ncm. O maior valor de desajuste observado por pilar foi utilizado. O valor do torque de desaperto, avaliado com um torquímetro digital (TQ-680, Instrutherm, Brasil), foi calculado em porcentagem do valor do torque inicial (100 por cento) dado aos parafusos protéticos. O teste de correlação de Pearson (p<0,05), entre os valores de desajuste (29,08 ± 8,78 µm) e as porcentagens da perda de torque (50,71 ± 11,37 por cento), não mostrou correlação estatisticamente significante (p=0,295) entre tais fatores. Dentro das limitações do estudo, pode ser concluído que não necessariamente grandes valores de desajustes verticais implicarão em grades perdas de torque.


Asunto(s)
Pilares Dentales , Prótesis Dental de Soporte Implantado , Fracaso de la Restauración Dental , Implantación Dental Endoósea/efectos adversos , Implantes Dentales/efectos adversos , Retención de Prótesis Dentales/instrumentación , Modelos Dentales , Análisis del Estrés Dental , Ajuste de Prótesis , Torque
8.
RPG rev. pos-grad ; 7(1): 31-7, jan.-mar. 2000. ilus, tab, graf
Artículo en Portugués | LILACS, BBO | ID: lil-298255

RESUMEN

Avaliou-se a força necessária para o deslocamento axial dos clipes plásticos sobre barras fundidas de cinco sistemas de três diferentes fabricantes (2 Conexäo, 2 Servo-Dental e 1 EDS) e comparou-se a perda da retençäo dos conjuntos durante o período de zero a 5 anos de uso simulado. Para promover a inserçäo e remoçäodos conjuntos, adaptou-se uma máquina de costura provida de movimentos verticais, a qual, por meio de um conta-giros, registrava os números de ciclos associando-os aos intervalos de tempo. Com o auxílio de uma máquina de ensaios universal (Kratos), realizou-se a remoçäo dos corpos-de-prova, a uma velocidade de 0,5 mm/min, sendo possível determinar e quantificar a retençäo em kgf dos 5 conjuntos de barra/clipes. Com base nos resultados da análise de variância (ANOVA), pôde-se concluir que: todos os conjuntos de barra/clipes apresentaram comportamento semelhante durante o período testado. Quanto à perda de retençäo, que ocorreu de forma gradual, houve uma diferença estatisticamente significante (p < 0,05) entre a força necessária para a remoçäo do conjunto do fabricante Conexäo, de forma circular e clipe de menor tamanho, e a força necessária para a remoçäo dos demais conjuntos de clipes sobre barras. Nenhum dano visível ocorreu a qualquer um dos conjuntos testados, o que näo levou à necessidade de substituiçäo de clipe nesse período de teste


Asunto(s)
Prótesis Dental/instrumentación , Prótesis Dental/métodos , Retención de Prótesis Dentales/instrumentación , Rehabilitación Bucal/instrumentación , Rehabilitación Bucal/métodos
9.
Rev. bras. odontol ; 56(5): 234-8, set.-out.1999. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: lil-255889

RESUMEN

Um dos problemas que ocorrem no emprego dos implantes está associado ao afrouxamento das conexöes, devido à falta de ajuste entre o sextavado do implante e do abutment. Uma das causas do desajuste tem sido a variaçäo dimensional e a näo ocorrência de intercambialidade das peças. Neste trabalho, fez-se a análise estatística das dimensöes de implantes Master Screw e comparou-se os resultados com dimensöes dos implantes Ster-Oss, Lifecore e Calcitek existentes na literatura. Os resultados mostraram que os implantes Master Screw possuem tolerância dimensionais equivalentes a dos implantes importados, o que permite boa ajustagem com os abutments e possibilidade de reduzir o afrouxamento dos sistemas


Asunto(s)
Pilares Dentales/normas , Implantes Dentales/normas , Retención de Prótesis Dentales/instrumentación , Retención de Prótesis Dentales/métodos , Tecnología Odontológica , Resistencia a la Tracción
10.
Artículo en Inglés | IMSEAR | ID: sea-51402

RESUMEN

This study was done to evaluate the retention of complete cast crowns in teeth with adequate and inadequate crown height and to evaluate the effects of auxiliary retentive features on retention from of complete cast crowns. Thirty-six extracted human maxillary first premolars were obtained. In one group teeth were prepared to a constant height of 3.5 mm and in the second group teeth were prepared to a constant height of 2.5 mm. Each group was further subgrouped into three. In the first subgroup teeth were prepared conventionally, second subgroup proximal grooves were incorporated and in the third subgroup proximal boxes were incorporated. Tensional forces required to dislodge each cemented casting from its preparation was used for comparison of retention quality. These results were then subjected to an analysis of variance (ANOVA). The retention of crown in tooth with adequate crown height were statistically highly significant (P < 0001), compared to inadequate crown height and in boxes compared to grooves and conventional preparation.


Asunto(s)
Análisis de Varianza , Diente Premolar , Coronas , Técnica de Colado Dental , Retención de Prótesis Dentales/instrumentación , Humanos , Maxilar , Preparación Protodóncica del Diente/métodos
12.
Bauru; s.n; 1997. 72 p. ilus, tab.
Tesis en Portugués | LILACS, BBO | ID: lil-222719

RESUMEN

No presente estudo avaliou-se a força necessária para o deslocamento axial dos clipes plásticos sobre barras fundidas de cinco conjuntos de três diferentes fabricantes (2 Conexäo, 2 Servo-Dental, 1 EDS) e comparou-se a perda de retençäo dos conjuntos durante o período de zero a 5 anos de uso simulado. Para promover a inserçäo e remoçäo dos conjuntos, adaptou-se uma máquina de costura provida de movimentos verticais, a qual, por meio de um conta-giros registrava os números de ciclos associando-se aos intervalos de tempo. Com o auxílio de uma máquina de ensaios universal (Kratos), realizou-se a remoçäo dos corpos de prova, à uma velociadde de 5mm/min., onde foi possível determinar e quantificar a retençäo expressos em kgf dos 5 conjuntos de barra/clipes. Baseado nos resultados da Análise de Variância (ANOVA), pôde-se concluir que: todos os Conjuntos de barra/clipes apresentaram comportamento semelhante durante o período de zero a 5 anos de uso simulado. Quanto a perda de retençäo, o que ocorreu de forma gradual, houve uma diferença significante (p < 0,05) do Conjunto do fabricante Conexäo de forma circular e clipe de menor tamanho, em relaçäo a quantidade de força necessária para a remoçäo dos demais conjuntos clipes sobre as barras. Nenhum dano visível ocorreu a qualquer um dos conjuntos testados, o que näo levou a necessidade de substituiçäo de clipe, neste período


Asunto(s)
Prótesis Dental/instrumentación , Prótesis Dental/métodos , Retención de Prótesis Dentales/instrumentación , Rehabilitación Bucal/instrumentación , Rehabilitación Bucal/métodos
14.
Bauru; s.n; 1986. 96 p. ilus, tab.
Tesis en Portugués | LILACS, BBO | ID: lil-246752

RESUMEN

O objetivo deste trabalho foi verificar a resistência de uniäo de restauraçöes atacadas eletroliticamente e fixadas com Conclude, usando 2 agentes de uniäo no esmalte (Scotchbond e Concise) e restauraçöes tratadas apenas com jatos de óxido de alumínio e fixadas com Panavia Ex. Foram utilizados 4 tipos de preparos para próteses adesiva: desgaste lingual e proximais com 1 nicho oclusal (preparo 1); desgaste lingual e proximais com 2 nichos oclusais (preparo 2); desgaste lingual e proximais com caixas ocluso-proximal (preparo 3) e preparo para coroa total (preparo 4). Todos os preparos foram realizados em esmalte. Para isso, foram selecionados 90 molares recém-extraídos e incluídos em cilindros de resina acrília e as restauraçöes fundidas com uma liga de Ni-Cr-Be (Litecast B). Após a fixaçäo, as restauraçöes foram removidas por traçäo em uma máquina de ensaios Universal (Instron) à uma velocidade de 0,5mm/minuto. Com base nos resultados obtidos, concluiu-se: A utilizaçäo do Scotchbond como agente de uniäo em esmalte influenciou positivamente na resistência de uniäo, embora näo tenha ocorrido diferença estatisticamente significante; Comparando os 4 tipos de preparos, as restauraçöes fixadas com Conclude, no preparo n§ 4, apresentaram os melhores resultados seguidos pelos preparos n§ 2, 1 e 3; Com Panavia Ex, o preparo n§ 4 apresentou os melhores resultados seguidos pelos preparos n§ 3, 1 e 2; As restauraçöes fixadas com Panavia Ex, apresentaram resultados superiores aos fixados com Conclude, especificamente com os preparos n§ 3 e 4; Esses resultados mostram que restauraçöes fixadas com Conclude ou Panavia Ex, podem ser indicadas com retentores para próteses fixas adesivas em dentes posteriores


Asunto(s)
Dentadura Parcial Fija con Resina Consolidada/normas , Retención de Prótesis Dentales/instrumentación , Retención de Prótesis Dentales/métodos , Recubrimientos Dentinarios/análisis , Berilio/química , Aleaciones de Cromo/química , Materiales Dentales , Restauración Dental Permanente , Electrólitos/análisis , Aleaciones Dentales/química , Óxido de Aluminio/análisis , Cementos de Resina/análisis
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA