Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 559
Filtrar
1.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 40-45, 2024.
Artículo en Chino | WPRIM | ID: wpr-1009106

RESUMEN

OBJECTIVE@#To compare the accuracy and effectiveness of orthopaedic robot-assisted minimally invasive surgery versus open surgery for limb osteoid osteoma.@*METHODS@#A clinical data of 36 patients with limb osteoid osteomas admitted between June 2016 and June 2023 was retrospectively analyzed. Among them, 16 patients underwent orthopaedic robot-assisted minimally invasive surgery (robot-assisted surgery group), and 20 patients underwent tumor resection after lotcated by C-arm X-ray fluoroscopy (open surgery group). There was no significant difference between the two groups in the gender, age, lesion site, tumor nidus diameter, and preoperative pain visual analogue scale (VAS) scores ( P>0.05). The operation time, lesion resection time, intraoperative blood loss, intraoperative fluoroscopy frequency, lesion resection accuracy, and postoperative analgesic use frequency were recorded and compared between the two groups. The VAS scores for pain severity were compared preoperatively and at 3 days and 3 months postoperatively.@*RESULTS@#Compared with the open surgery group, the robot-assisted surgery group had a longer operation time, less intraoperative blood loss, less fluoroscopy frequency, less postoperative analgesic use frequency, and higher lesion resection accuracy ( P<0.05). There was no significant difference in lesion resection time ( P>0.05). All patients were followed up after surgery, with a follow-up period of 3-24 months (median, 12 months) in the two groups. No postoperative complication such as wound infection or fracture occurred in either group during follow-up. No tumor recurrence was observed during follow-up. The VAS scores significantly improved in both groups at 3 days and 3 months after surgery when compared with preoperative value ( P<0.05). The VAS score at 3 days after surgery was significantly lower in robot-assisted surgery group than that in open surgery group ( P<0.05). However, there was no significant difference in VAS scores at 3 months between the two groups ( P>0.05).@*CONCLUSION@#Compared with open surgery, robot-assisted resection of limb osteoid osteomas has longer operation time, but the accuracy of lesion resection improve, intraoperative blood loss reduce, and early postoperative pain is lighter. It has the advantages of precision and minimally invasive surgery.


Asunto(s)
Humanos , Robótica , Osteoma Osteoide/cirugía , Ortopedia , Pérdida de Sangre Quirúrgica , Estudios Retrospectivos , Recurrencia Local de Neoplasia , Procedimientos Quirúrgicos Mínimamente Invasivos , Neoplasias Óseas/cirugía , Analgésicos , Resultado del Tratamiento
3.
Chinese Journal of Medical Instrumentation ; (6): 645-650, 2023.
Artículo en Chino | WPRIM | ID: wpr-1010255

RESUMEN

With the progress of science and technology and the increase of clinical demand, medical robots have developed rapidly and played a important role in promoting the medical cause. Service robot is a branch of medical robot, which is mainly oriented to medical service and assistance needs, and has been applied in many medical scenarios and achieved demonstration effects. This research first describes the development of medical service robots, and then summarizes the key technologies and clinical applications of robots. Finally, it points out the challenges and directions that medical service robots face at present, and puts forward prospects for their further development in the medical field.


Asunto(s)
Robótica , Tecnología
4.
Chinese Journal of Medical Instrumentation ; (6): 638-644, 2023.
Artículo en Chino | WPRIM | ID: wpr-1010254

RESUMEN

Vascular interventional surgery is an important means to treat cardiovascular and cerebrovascular diseases, but the particularity of its working environment will bring greater radiation threat to doctors. Vascular interventional surgery robots can effectively improve the working environment of doctors and can provide more stable operations, improve the success rate of surgery. This study mainly introduces the current research status, key technologies, and future application of vascular interventional surgical robots.


Asunto(s)
Robótica , Procedimientos Quirúrgicos Vasculares/métodos , Corazón , Tecnología
5.
Chinese Journal of Medical Instrumentation ; (6): 591-597, 2023.
Artículo en Chino | WPRIM | ID: wpr-1010245

RESUMEN

Robotic puncture system has been widely used in modern minimally invasive surgery, which usually uses hand-eye calibration to calculate the spatial relationship between the robot and the optical tracking system. However, the hand-eye calibration process is time-consuming and sensitive to environmental changes, which makes it difficult to guarantee the puncture accuracy of the robot. This study proposes an uncalibrated positioning method for puncture robot based on optical navigation. The method divides the target path positioning into two stages, angle positioning and position positioning, and designs angle image features and position image features respectively. The corresponding image Jacobian matrix is constructed based on the image features and updated by online estimation with a cubature Kalman filter to drive the robot to perform target path localization. The target path positioning results show that the method is more accurate than the traditional hand-eye calibration method and saves significant preoperative preparation time by eliminating the need for calibration.


Asunto(s)
Robótica , Procedimientos Quirúrgicos Robotizados , Calibración , Procedimientos Quirúrgicos Mínimamente Invasivos , Dispositivos Ópticos
6.
Chinese Journal of Medical Instrumentation ; (6): 582-586, 2023.
Artículo en Chino | WPRIM | ID: wpr-1010243

RESUMEN

In recent years, with the rapid development of Chinese domestic surgical robot technology and the expansion of the application market, the "industry-university-research-medicine" collaborative innovation transformation mode has gradually developed and formed. Medical institutions play an important role in multi-party cooperation with enterprises, universities, and research institutes, as well as in product planning, technology research and development, achievement transformation, and personnel training. On the basis of reviewing the current situation of the development of the "industry-university-research-medicine" collaborative innovation transformation mode of domestic surgical robots, this study explores the multiple roles played by medical institutions in this mode and challenges, further putting forward corresponding recommendations.


Asunto(s)
Humanos , Robótica , Universidades , Medicina , Industrias , Tecnología
7.
Chinese Journal of Surgery ; (12): 61-65, 2023.
Artículo en Chino | WPRIM | ID: wpr-970174

RESUMEN

Objective: To examine the application value of 3D Slicer software assisted domestic frameless stereotactic robot in biopsy of intracranial lesions. Methods: A retrospective analysis was performed on 80 patients who admitted consecutively and underwent intracerebral lesions biopsy with the domestic frameless stereotactic robot at Department of Neurosurgery, Aerospace Central Hospital from January 2019 to December 2021. There were 36 males and 44 females, with a mean age of (38.5±18.0) years (range: 6 to 71 years). Before surgery only enhanced T1-weighted three-dimensional magnetization prepared gradient echo sequences and diffusion tensor imaging scans were performed. Self-reconstruction of intracranial lesions, cerebral cortex and blood vessels was carried out using 3D Slicer software system after the DICOM format imaging data of 80 patients were collected. These imaging data were merged to the workstation of the domestic frameless stereotactic robot for preoperative surgical planning and the surgical puncture path was designed to avoid blood vessels in the brain functional area, cerebral cortex and sulcus. Results: All frameless stereotactic biopsy were successfully performed. Postoperative pathological diagnosis included 50 cases of diffuse astrocytic and oligodendroglioma, 15 cases of lymphoma, 5 cases of metastatic tumors, 5 cases of inflammatory demyelinating disease, 2 cases of inflammatory granuloma, 1 case of hemangioma, 1 case of acute lymphoblastic leukemia intracranial invasion and 1 case of seminoma. The positive diagnosis rate was 100% (80/80). Postoperative imaging confirmed that the puncture path and target were accurately implemented according to the preoperative planning, and the target error was (1.32±0.44) mm (range: 0.55 to 1.99 mm). One case of puncture-related bleeding occurred at the target after surgery and improved after treatment. Conclusion: The three-dimensional multimodal images reconstructed by the 3D Slicer software before operation could help the surgeons make the preoperative planning and reduce the risk of stereotactic brain biopsy.


Asunto(s)
Masculino , Femenino , Humanos , Niño , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Neoplasias Encefálicas/patología , Imagen de Difusión Tensora , Estudios Retrospectivos , Robótica , Biopsia , Programas Informáticos , Técnicas Estereotáxicas
8.
Acta Academiae Medicinae Sinicae ; (6): 853-858, 2023.
Artículo en Chino | WPRIM | ID: wpr-1008140

RESUMEN

With the continuous advances in modern medical technology and equipment,minimally invasive surgery (MIS) is widely applied in clinical practice.Ultrasound (US) as a real-time,portable,and radiation-free medical imaging method can be used for the intraoperative guidance in MIS to ensure safe and effective surgery.However,the physical characteristics of conventional US fail to display some tissue structures of the human body due to the existence of gas and bone.US-based navigation can make up for the deficiencies by advanced imaging technologies including spatial orientation,image reconstruction,and multi-modality image fusion,being real-time,accurate,and radiation-free.Therefore,US-guided robots can achieve safe,effective,and minimally invasive operation in MIS.This paper reviews the studies of US-guided robots in MIS and prospects the development of this field.


Asunto(s)
Humanos , Robótica/métodos , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Ultrasonografía , Fusión Vertebral/métodos , Ultrasonografía Intervencional/métodos
9.
Chinese Medical Journal ; (24): 2960-2966, 2023.
Artículo en Inglés | WPRIM | ID: wpr-1007720

RESUMEN

BACKGROUND@#The KangDuo-Surgical Robot-01 (KD-SR-01) system is a new surgical robot recently developed in China. The aim of this study was to present our single-center experience and mid-term outcomes of urological procedures using the KD-SR-01 system.@*METHODS@#From August 2020 to April 2023, consecutive urologic procedures were performed at Peking University First Hospital using the KD-SR-01 system. The clinical features, perioperative data, and follow-up outcomes were prospectively collected and analyzed.@*RESULTS@#A total of 110 consecutive patients were recruited. Among these patients, 28 underwent partial nephrectomy (PN), 41 underwent urinary tract reconstruction (26 underwent pyeloplasty, 3 underwent ureteral reconstruction and 12 underwent ureterovesical reimplantation [UR]), and 41 underwent radical prostatectomy (RP). The median operative time for PN was 112.5 min, 157.0 min for pyeloplasty, 151.0 min for ureteral reconstruction, 142.5 min for UR, and 138.0 min for RP. The median intraoperative blood loss was 10 mL for PN, 10 mL for pyeloplasty, 30 mL for ureteral reconstruction, 20 mL for UR, and 50 mL for RP. All procedures were successfully completed without conversion, and there were no major complications in any patient. The median warm ischemia time of PN was 17.3 min, and positive surgical margin was not noted in any patient. The overall positive surgical margin rate of RP was 39% (16/41), and no biochemical recurrence was observed in any RP patient during the median follow-up of 11.0 months. The surgical success rates of pyeloplasty and UR were 96% (25/26) and 92% (11/12) during the median follow-up of 29.5 months and 11.5 months, respectively.@*CONCLUSION@#The KD-SR-01 system appears feasible, safe, and effective for most urological procedures, based on our single-center experience.


Asunto(s)
Masculino , Humanos , Procedimientos Quirúrgicos Robotizados/métodos , Robótica , Resultado del Tratamiento , Estudios Retrospectivos , Uréter/cirugía , Procedimientos Quirúrgicos Urológicos/métodos , Laparoscopía/métodos
10.
China Journal of Orthopaedics and Traumatology ; (12): 465-472, 2023.
Artículo en Chino | WPRIM | ID: wpr-981716

RESUMEN

OBJECTIVE@#To evaluate the early clinical efficacy of robot-assisted percutaneous short-segment bone cement-augmented pedicle screw fixation in the treatment of stageⅡ-Ⅲ Kümmell disease.@*METHODS@#The clinical data of 20 patients with stageⅡ-Ⅲ Kümmell's disease who underwent robot-assisted percutaneous bone cement-augmented pedicle screw fixation between June 2017 and January 2021 were retrospectively analyzed. There were 4 males and 16 females, aged from 60 to 81 years old with an average age of (69.1±8.3) years. There were 9 cases of stageⅡand 11 cases of stage Ⅲ, all of which were single vertebral lesions, including 3 cases of T11, 5 cases of T12, 8 cases of L1, 3 cases of L2, and 1 case of L3. These patients did not exhibit symptoms of spinal cord injury. The operation time, intraoperative blood loss, and complications were recorded. The position of pedicle screws and the filling and leakage of bone cement in gaps were observed using postoperative CT 2D reconstruction. The data of the visual analogue scale (VAS), Oswestry disability index (ODI), kyphosis Cobb angle, wedge angle of the diseased vertebra, and anterior and posterior vertebral height on lateral radiographs were statistically analyzed preoperatively, 1 week postoperatively, and at the final follow-up.@*RESULTS@#Twenty patients were followed up for 10 to 26 months, with an average follow-up of (16.0±5.1) months. All operations were successfully completed. The surgical duration ranged from 98 to 160 minutes, with an average of (122±24) minutes. The intraoperative blood loss ranged from 25 to 95 ml, with an average of (45±20) ml. There were no intraoperative vascular nerve injuries. A total of 120 screws were inserted in this group, including 111 screws at grade A and 9 screws at grade B according to the Gertzbein and Robbins scales. Postoperative CT indicated that the bone cement was well-filled in the diseased vertebra, and cement leakage occurred in 4 cases. Preoperative VAS and ODI were (6.05±0.18) points and (71.10±5.37)%, respectively, (2.05±0.14) points and (18.57±2.77)% at 1 week after operation, and (1.35±0.11) points and (15.71±2.12) % at final follow-up. There were significant differences between postoperative 1 week and preoperative, and between final follow-up and postoperative 1 week(P<0.01). Anterior and posterior vertebral height, kyphosis Cobb angle, and wedge angle of the diseased vertebra were(45.07±1.06)%, (82.02±2.11)%, (19.49±0.77) °, and (17.56±0.94) ° preoperatively, respectively, (77.00±0.99)%, (83.04±2.02)%, (7.34±0.56) °, and (6.15±0.52) ° at 1 week postoperatively, and (75.13±0.86)%, (82.39±0.45)%, (8.38±0.63) °, and (7.09±0.59) ° at the final follow-up.@*CONCLUSION@#Robot-assisted percutaneous short-segment bone cement-augmented pedicle screw fixation demonstrates satisfactory short-term efficacy in treating stageⅡ-Ⅲ Kümmell's disease as an effective minimally invasive alternative. However, longer operation times and strict patient selection criteria are necessary, and long-term follow-up is required to determine its lasting effectiveness.


Asunto(s)
Masculino , Femenino , Humanos , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Tornillos Pediculares , Cementos para Huesos , Robótica , Pérdida de Sangre Quirúrgica , Estudios Retrospectivos , Fracturas de la Columna Vertebral/cirugía , Vértebras Lumbares/lesiones , Resultado del Tratamiento , Cifosis , Vértebras Torácicas/lesiones , Fijación Interna de Fracturas
11.
Chinese Journal of Reparative and Reconstructive Surgery ; (12): 404-409, 2023.
Artículo en Chino | WPRIM | ID: wpr-981606

RESUMEN

OBJECTIVE@#To compare the short-term effectiveness of "SkyWalker" robot-assisted total knee arthroplasty (TKA) and traditional TKA.@*METHODS@#A clinical data of 54 patients (54 knees) with TKA who met the selection criteria between January 2022 and March 2022 was retrospectively analyzed. Among them, 27 cases underwent traditional TKA (traditional operation group) and 27 cases underwent "SkyWalker" robot-assisted TKA (robot-assisted operation group). There was no significant difference between the two groups ( P>0.05) in terms of gender, age, body mass index, osteoarthritis side, disease duration, and preoperative Knee Society Score (KSS), Western Ontario and McMaster University Osteoarthritis Index (WOMAC), visual analogue scale (VAS) score, hip-knee-ankle angle (HKA), lateral distal femoral angle (LDFA), medial proximal tibial angle (MPTA), and posterior proximal tibial angle (PPTA). The operative time, intraoperative bleeding volume, surgery-related complications, the KSS, WOMAC, and VAS scores before operation and at 6 months after operation, and Forgotten Joint Score (FJS) at 6 months after operation were recorded. X-ray films were taken to review the prosthesis position and measure HKA, LDFA, MPTA, and PPTA. The differences of the clinical and imaging indicators between before and after operation were calculated and statistically analyzed.@*RESULTS@#The operations were completed successfully in both groups. There was no significant difference in the operative time and intraoperative bleeding volume between the two groups ( P>0.05). After operation, 1 case of incision nonunion and 1 case of heart failure occurred in the traditional operation group, while no surgery-related complications occurred in the robotic-assisted operation group. The incidences of surgical complications were 7.4% (2/27) in the traditional operation group and 0 (0/27) in the robotic-assisted operation group, with no significant difference ( P=0.491). Patients in both groups were followed up 6 months. KSS score, WOMAC score, VAS score, and ROM significantly improved in both groups at 6 months after operation when compared with preoperative ones ( P<0.05). There was no significant difference between the two groups ( P>0.05) in the differences between the pre- and post-operative values of the clinical indicators and FJS scores at 6 months after operation. X-ray films showed that the lower extremity force lines of the patients improved and the knee prostheses were in good position. Except for LDFA in the robot-assisted operation group, HKA, LDFA, MPTA, and PPTA significantly improved in both groups at 6 months after operation when compared with the preoperative ones ( P<0.05). There was no significant difference between the two groups in the differences between the pre- and post-operative values of the radiological indicators ( P>0.05).@*CONCLUSION@#The "SkyWalker" robot-assisted TKA is one of the effective methods for the treatment of knee osteoarthritis and had good short-term effectiveness. But the long-term effectiveness needs to be further studied.


Asunto(s)
Humanos , Artroplastia de Reemplazo de Rodilla/métodos , Articulación de la Rodilla/cirugía , Prótesis de la Rodilla , Osteoartritis de la Rodilla/cirugía , Estudios Retrospectivos , Robótica , Resultado del Tratamiento
12.
Journal of Biomedical Engineering ; (6): 327-334, 2023.
Artículo en Chino | WPRIM | ID: wpr-981546

RESUMEN

The neural stimulator is a core component of animal robots. While the control effect of animal robots is influenced by various factors, the performance of the neural stimulator plays a decisive role in regulating animal robots. In order to optimize animal robots, embedded neural stimulators had been developed using flexible printed circuit board technology. This innovation not only enabled the stimulator to generate parameter-adjustable biphasic current pulses through control signals, but also optimized its carrying mode, material, and size, overcoming the disadvantages of traditional backpack or head-inserted stimulators, which have poor concealment and are prone to infection. Static, in vitro, and in vivo performance tests of the stimulator demonstrated that it not only had precise pulse waveform output capability, but also was lightweight and small in size. It had excellent in vivo performance in both laboratory and outdoor environments. Our study has high practical significance for the application of animal robots.


Asunto(s)
Animales , Robótica
13.
Chinese Journal of Surgery ; (12): 498-502, 2023.
Artículo en Chino | WPRIM | ID: wpr-981031

RESUMEN

Objective: To analyze the short-term clinical effects of robot-assisted and laparoscopic repair of the hiatal hernia. Methods: The clinical data of 56 patients underwent minimally invasive hiatal hernia repair from January 2021 to January 2022 in the Department of Minimally Invasive Surgery, Hernias and Abdominal Wall Surgery, People's Hospital of Xinjiang Uygur Autonomous Region were retrospectively analyzed. There were 32 males and 24 females, aging (59.7±10.7) years (range: 28 to 75 years). All patients were divided into laparoscopy group (n=27) and robot group (n=29) according to surgical procedures. Perioperative conditions, hospital stay, and improvement in symptoms before and after surgery were compared between the two groups by the t test, Wilcoxon rank-sum test and χ2 test. Results: All surgical procedures were successfully completed, without conversion to laparotomy or change in operation mode. There were no serious complications related to the operation. The intraoperative blood loss of the robot group was less than that of the laparoscopic group (M (IQR)): (20 (110) ml vs. 40 (80) ml, Z=-4.098, P<0.01). The operation time ((111.7±33.6) minutes vs. (120.4±35.0) minutes, t=-0.943, P=0.350) and hospitalization time ((3.9±1.4) days vs. (4.7±1.9) days, t=-1.980, P=0.053) of the robot group and the laparoscopic group were similar. Follow-up for 12 months after the operation showed no postoperative complications and recurrence. The score of the health-related quality of life questionnaire for gastroesophageal reflux disease in the robot group decreased from 10.8±2.8 before the operation to 6.5±0.6 after the operation, and that in the laparoscopic group decreased from 10.6±2.1 before the operation to 6.3±0.6 after the operation. There was no difference in the influence of different surgical methods on the change in score (t=0.030,P=0.976). Conclusion: Compared with laparoscopic repair of the hiatal hernia, robot-assisted hiatal hernia repair has the advantages of less bleeding, rapid postoperative recovery and good short-term effect.


Asunto(s)
Masculino , Femenino , Humanos , Hernia Hiatal/complicaciones , Estudios Retrospectivos , Robótica , Herniorrafia/métodos , Calidad de Vida , Laparoscopía/métodos , Recurrencia , Fundoplicación/métodos
14.
Chinese Acupuncture & Moxibustion ; (12): 463-468, 2023.
Artículo en Chino | WPRIM | ID: wpr-980745

RESUMEN

The difficulties such as how to accurately locate acupoints and safely insert needles are presented in acupuncture robot. The puncture robot with high technological similarity to acupuncture robot is getting mature, and a large number of human trials and animal experiments have been conducted for the development of puncture robot. Through comparing the similarities and differences between puncture robot and acupuncture robot in the aspects of through-skin puncture, needle insertion and needle removal, the valuable technology of puncture robot is analyzed for the development of acupuncture robot, and the crucial direction of technology migration is determined. ①Integrating the mechanical feedback and medical imaging technology and utilizing the multi-modal perception to achieve the safety of acupuncture operation. ②Emphasizing the integration of the existing designs of chest puncture robot to realize the acupuncture operation with inhalation and exhalation involved. ③Focusing on the development of relevant technology of automatic needle removal through conducting the actual scenario of treatment with acupuncture robot in patients under non-anaesthetic condition.


Asunto(s)
Animales , Humanos , Robótica , Estudios de Factibilidad , Terapia por Acupuntura , Punciones , Acupuntura , Agujas
15.
Journal of Central South University(Medical Sciences) ; (12): 221-230, 2023.
Artículo en Inglés | WPRIM | ID: wpr-971389

RESUMEN

OBJECTIVES@#Surgical robot system has broken the limitation of traditional surgery and shown excellent performance in surgery, and has been widely used in minimally invasive treatment in most areas of surgery. This study aims to verify the basic performance of the domestic surgical robot system and the safety and effectiveness of the integrated bipolar electrocoagulation and ultrasonic knife.@*METHODS@#The basic performance of the domestic surgical robot system was evaluated by completing the square knot and surgical knot, vertical and horizontal perforation and right ring perforation and suture, as well as picking up beans. Compared with laparoscopy, the safety and effectiveness of the domestic surgical robot after integrated interconnection bipolar electrocoagulation and ultrasonic scalpel were evaluated by detecting the vascular closure performance and the degree of histopathological damage in animals.@*RESULTS@#Compared with freehand knotting, domestic robot knotting speed and circumference were slightly worse, but better than laparoscopic knotting. There was no statistical significance in the tension difference of the surgical knots among the 3 methods (P>0.05), but the tension of the square knots made by the freehand and the domestic surgical robot was greater than that of the laparoscopy (P<0.05). The space required for both the left and right forceps heads of knots was smaller than that of laparoscopy (P<0.001), which successfully completed the 4 quadrant suture tasks, and the time of picking up beans was significantly less than that of laparoscopy (P<0.05). There was no significant difference in the temperature of the liver tissue after the bipolar electrocoagulation between the interconnected domestic surgical robot and the laparoscopy (P>0.05), and the acute thermal injury was observed under the light microscope. The temperature of the liver tissue treated by the domestic robotic ultrasound knife was higher than that of the laparoscopic ultrasound knife (P<0.05).@*CONCLUSIONS@#Domestic surgical robots are obviously superior to laparoscopy in suturing, knotting, and moving objects, and domestic surgical robots' interconnect bipolar electrocoagulation and ultrasonic knife have achieved success in animal experiments, and hemostasis is considered to be safe and effective.


Asunto(s)
Animales , Robótica , Laparoscopía/métodos , Ultrasonografía
16.
Chinese Journal of Medical Instrumentation ; (6): 32-37, 2023.
Artículo en Chino | WPRIM | ID: wpr-971299

RESUMEN

Characteristics of two major categories of RA equipment which defined in the standard are interpreted firstly. Few representative RA equipment in current market and their key product features are introduced. Then, classifications of different indexes of spatial positioning accuracy are declared, the difficulties of performing testing process on each indexes are further explained. Meanwhile, different kinds of three dimensional coordinate measuring equipment that are cutting edge at present stage are introduced with their main methods of use explained. According to characteristics of three dimensional coordinate measuring equipment on the market, proper measuring equipment for testing certain index of spatial positioning accuracy and corresponding experiment method are introduced.


Asunto(s)
Robótica/normas , Procedimientos Quirúrgicos Robotizados/instrumentación
17.
Chinese Journal of Medical Instrumentation ; (6): 26-31, 2023.
Artículo en Chino | WPRIM | ID: wpr-971298

RESUMEN

Due to the need to achieve precise operations during surgery, in order to prevent hand tremors and poor surgical field of view, more and more surgical robots are used in surgical operations combined with navigation technology to meet the requirements for surgical accuracy. Open surgery such as orthopaedics, joint replacement and neurosurgery on the market generally use optical navigation systems to guide robots to achieve precise positioning, but optical navigation systems cannot be used for operations in areas with small surgical space. Therefore, a robotic surgical system based on electromagnetic navigation technology that can be applied to the craniofacial area was proposed. By using this robot, the problems of difficult operation and low precision caused by the narrow craniofacial space can be solved. Key techniques and considerations are studied. The function of the developed prototype is verified through model tests. The test results show that the surgical robot under the electromagnetic navigation technology can achieve precise surgical operations improve the success rate of the doctor's surgery and reduce postoperative complications.


Asunto(s)
Humanos , Robótica , Procedimientos Quirúrgicos Robotizados , Fenómenos Electromagnéticos , Complicaciones Posoperatorias
18.
Chinese Journal of Medical Instrumentation ; (6): 1-12, 2023.
Artículo en Chino | WPRIM | ID: wpr-971295

RESUMEN

OBJECTIVE@#To study the development of surgical robots at home and abroad in recent years.@*METHODS@#Through a large number of literature review and analysis, the qualification approval and technical function characteristics of domestic and foreign surgical robots from January 2019 to July 2022 were analyzed.@*RESULTS@#The related situations of 39 surgical robots were analyzed and reported, and the shortcomings and future development direction of the current surgical robots were summarized.@*CONCLUSIONS@#The development of surgical robots in China is now in a rapid development stage. At present, surgical robots generally have the disadvantages of high cost, lack of tactile feedback (force feedback), large size, large space occupation and difficult to move. In the future, it will develop towards intelligent, miniaturized, remote, open and low-cost.


Asunto(s)
China , Robótica , Procedimientos Quirúrgicos Robotizados
19.
Chinese Journal of Traumatology ; (6): 83-93, 2023.
Artículo en Inglés | WPRIM | ID: wpr-970967

RESUMEN

PURPOSE@#Robot-assisted technology is a forefront of surgical innovation that improves the accuracy of total knee arthroplasty (TKA). But whether the accuracy of surgery can improve the clinical efficacy still needs further research. The purpose of this study is to perform three-dimensional (3D) analysis in the early postoperative period of patients who received robot-assisted total knee arthroplasty (RATKA), and to study the trend of changes in gait parameters after RATKA and the correlation with the early clinical efficacy.@*METHODS@#Patients who received RATKA in the Center of Joint Surgery, the First Hospital Affiliated to Army Military Medical University from October 2020 to January 2021 were included. The imaging parameters, i.e., hip-knee-ankle angle, lateral distal femoral angle, medial proximal tibial angle, posterior condylar angle were measured 3 months post-TKA. The 3D gait analysis and clinical efficacy by Western Ontario Mac Master University Index (WOMAC) score were performed pre-TKA, 3 and 6 months post-TKA. The differences in spatiotemporal parameters of gait, kinetic parameters, and kinematic parameters of the operated limb and the contralateral limb were compared. The correlation between gait parameters and WOMAC scores was analyzed. Paired sample t-test and Wilcoxon rank-sum test were used to analyze the difference between groups, and Spearman correlation coefficient was used to analyze the correlation.@*RESULTS@#There were 31 patients included in this study, and the imaging indexes showed that all of them returned to normal post-TKA. The WOMAC score at 3 months post-TKA was significantly lower than that pre-TKA, and there was no significant difference between at 3 and 6 months. The 3D gait analysis results showed that the double support time of the operated limb reduced at 3 and 6 months (all p < 0.05), the maximum extension and maximum external rotation of the knee joint increased at stance phase, and the maximum flexion angle, the range of motion and the maximum external rotation increased at swing phase. Compared with the preoperative data, there were significant improvements (all p < 0.05). Compared with the contralateral knee joint, the maximum external rotation of the knee joint at swing phase was smaller than that of the contralateral side, and the maximum flexion and extension moment was greater than that of the contralateral knee. The maximum external rotation moment of the joint was greater than that of the contralateral knee joint (p < 0.05). There was a negative correlation between the single support time pre-TKA and the WOMAC score at 3 months (p = 0.017), and the single support time at 3 months was negatively correlated with the WOMAC score at 6 months (p = 0.043). The cadence at 6 months was negatively correlated with the WOMAC score at 6 months (p = 0.031). The maximum knee extension at stance phase at 6 months was negatively correlated with the WOMAC score at 6 month (p = 0.048). The maximum external rotation at stance phase at 6 months was negatively correlated with the WOMAC score at 6 months (p = 0.024).@*CONCLUSION@#The 3D gait analysis of RATKA patients is more sensitive than WOMAC score in evaluating the clinical efficacy. Trend of changes in gait parameters shows that the knee joint support, flexion and extension function, range of motion, external rotation and varus deformity moment of the patient were significantly improved at 3 months after surgery, and continued to 6 months after surgery. Compared with the contralateral knee, the gait parameters of the operated limb still has significant gaps in functionality, such as the external rotation and flexion and extension. The single support time, cadence, knee extension, and knee external rotation of the operated limb have a greater correlation with the postoperative WOMAC score. Postoperative rehabilitation exercises should be emphasized, which is of great value for improving the early efficacy of RATKA.


Asunto(s)
Humanos , Artroplastia de Reemplazo de Rodilla , Análisis de la Marcha , Robótica , Osteoartritis de la Rodilla/cirugía , Articulación de la Rodilla/cirugía , Resultado del Tratamiento , Rango del Movimiento Articular , Fenómenos Biomecánicos
20.
China Journal of Orthopaedics and Traumatology ; (12): 221-225, 2023.
Artículo en Chino | WPRIM | ID: wpr-970851

RESUMEN

OBJECTIVE@#To investigate the clinical efficacy and advantages of Tianji orthopedic robot assisted cannulated screw internal fixation for femoral neck fracture.@*METHODS@#The clinical data of 41 patients with femoral neck fracture who underwent internal fixation with cannulated screws from January 2019 to January 2022 were retrospectively analyzed. According to different surgical methods, they were divided into Tianji robot group and traditional cannulated screw fixation group (traditional operation group). Among them, there were 18 patients in Tianji robot group including 8 males and 10 females with age of (56.00±4.22) years old, Garden typeⅠ (4 cases), type Ⅱ (11 cases), type Ⅲ (2 cases), and type Ⅳ (1 case). There were 23 patients in the traditional operation group, including 10 males and 13 females, aged (54.87±4.81) years old;there were 5 cases of Garden typeⅠ, 14 cases of type Ⅱ, 3 cases of type Ⅲ and 1 case of type Ⅳ. The operation time, intraoperative blood loss, fluoroscopy times, guide needle placement times, operation costs and other indicators were observed and compared between two groups. Harris score was used to evaluate hip joint function 12 months after operation.@*RESULTS@#The wounds of all patients healed in Grade A without complications. There were significant differences between two groups in terms of operation time, times of intraoperative fluoroscopy, times of guide needle placement, amount of intraoperative bleeding, and operation cost (P<0.05). All 41 patients were followed up for at least 12 months. The fractures of both groups were healed. There was no infection, screw loosening, fracture displacement and femoral head necrosis in Tianji robot group during follow-up;Screw loosening occurred in 2 patients in the traditional operation group during follow-up. At 12 months after operation, Harris hip joint function score of Tianji robot group was higher than that of traditional operation group in daily activity, lameness, joint activity score and total score (P<0.05).@*CONCLUSION@#Tianji robot assisted nail placement is a better method for the treatment of femoral neck fracture, which improves the surgical efficiency, is more accurate, has higher success rate of one-time nail placement, shorter operation time, less radiation, and has better hip joint function recovery after surgery.


Asunto(s)
Masculino , Femenino , Humanos , Persona de Mediana Edad , Robótica , Estudios Retrospectivos , Fracturas del Cuello Femoral/cirugía , Tornillos Óseos , Fijación Interna de Fracturas/métodos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA