Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Arq. bras. oftalmol ; 82(3): 189-194, May-June 2019. tab, graf
Artículo en Inglés | LILACS | ID: biblio-1001312

RESUMEN

ABSTRACT Purpose: The purpose of this study was to objectively assess the optical vision quality of patients before and after Nd:YAG capsulotomy for posterior capsular opacification using a double-pass retinal imaging system. Methods: We retrospectively analyzed the data from 26 pseudophakic eyes with posterior capsular opacification that underwent Nd:YAG capsulotomy. The objective scatter indices, modulation transfer function cutoff frequencies, Strehl ratios, and logMAR corrected distance visual acuities were assessed before and after YAG capsulotomy with a double-pass retinal imaging system (OQAS II, Visiometrics, Spain). We also analyzed data from a subgroup of 10 patients with pre-YAG corrected distance visual acuity of 0.10 logMAR (20/25) or better. Results: Vision quality indices improved in all 26 eyes, resulting in a statistically significant improvement in the corrected distance visual acuity (p=0.007), objective scatter index (p=0.001), modulation transfer function cutoff frequency (p=0.001), and Strehl ratio (p=0.020). The overall mean improvements included 0.12 ± 0.04 logMAR for corrected distance visual acuity, 2.84 ± 0.76 for objective scatter index, 12.29 ± 2.77 for modulation transfer function cutoff frequency, and 0.06 ± 0.03 for Strehl ratio. Our sub-analysis of 10 eyes with 0.10 logMAR (20/25) corrected distance visual acuity or better also showed a statistically significant improvement in the mean objective scatter index (0.76 ± 16; p=0.001), resulting in approximately 35% decrease in intraocular light scatter. Conclusions: The objective vision quality measurements as assessed by the double-pass retinal imaging system showed a significant improvement after YAG capsulotomy. This suggests that the objective scatter index improves after YAG capsulotomy, even in eyes with pre-YAG 0.10 logMAR (Snellen 20/25) corrected distance visual acuity or better.


RESUMO Objetivo: Avaliar objetivamente a qualidade da visão óptica antes e depois da capsulotomia com Nd: YAG, obtida por imagem pelo metodo de dupla passagem de luz em pacientes com opacificação capsular posterior. Método: Análise retrospectiva de 26 olhos pseudofácicos com opacificação capsular posterior visualmente significativa, que foram submetidos à capsulotomia de Nd: YAG. O índice de dispersão objetiva, a função de transferência de modulação, a relação de Strehl e a acuidade visual à distância corrigida foram avaliados antes e após a capsulotomia com YAG usando o dupla passagem de luz (OQAS II, Visiometrics, Espanha). Também foi analisado um subgrupo de pacientes com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (20/25) ou melhor. Resultados: Os índices de qualidade da visão melhoraram em todos os 26 olhos, resultando em uma melhora estatisticamente significativa na acuidade visual à distância corrigida (p=0,007), índice de dispersão objetiva (p=0,001), função de transferência de modulação (p=0,001) e relação de Strehl (p=0,020). A melhora média na acuidade visual à distância corrigida foi de 0,12 ± 0,04 logMAR, no índice de dispersão objetiva foi de 2,84 ± 0,76, no função de transferência de modulação foi de 12,29 ± 2,77 e na razão de Strehl foi de 0,06 ± 0,03 em todos os olhos. Sub-análise de 10 olhos com 0.10 logMAR (20/25) acuidade visual à distância corrigida ou melhor também mostrou uma melhora estatisticamente significativa no índice de dispersão objetiva (p=0,001). A melhora média no OSI foi de 0,76 ± 16, uma diminuição de 35% na dispersão da luz intraocular. Conclusões: A qualidade da visão avaliada pelo dupla passagem de luz mostra uma melhora significativa nas medidas objetivas da qualidade da visão após a capsulotomia do YAG. O índice de dispersão objetiva melhora após a capsulotomia YAG, mesmo em olhos com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (Snellen 20/25) ou melhor.


Asunto(s)
Humanos , Masculino , Femenino , Anciano , Agudeza Visual/fisiología , Seudofaquia/fisiopatología , Opacificación Capsular/fisiopatología , Capsulotomía Posterior/rehabilitación , Valores de Referencia , Retina/fisiopatología , Retina/diagnóstico por imagen , Estudios Retrospectivos , Resultado del Tratamiento , Seudofaquia/diagnóstico por imagen , Láseres de Estado Sólido/uso terapéutico , Opacificación Capsular/diagnóstico por imagen , Capsulotomía Posterior/métodos
2.
Korean Journal of Ophthalmology ; : 180-191, 2016.
Artículo en Inglés | WPRIM | ID: wpr-50644

RESUMEN

PURPOSE: To evaluate visual outcomes following implantation of a trifocal diffractive intraocular lens (IOL) and to analyze their correlation with patient satisfaction and ease of performing daily tasks. METHODS: This was a prospective study enrolling 100 eyes of 50 patients undergoing cataract surgery with implantation of trifocal IOL AT LISA tri 839MP. Visual and refractive outcomes were evaluated during a 3-month follow-up. Postoperatively, a questionnaire was used to evaluate patient satisfaction with regard to surgical outcome, spectacle independence, perception of photic phenomena, and ease of performing some vision-related activities. RESULTS: A total of 91%, 87%, and 79% of eyes achieved a monocular uncorrected distance, near, and intermediate visual acuity of 0.1 logarithm of the minimum angle of resolution or better, respectively. After the surgery, 96% of the patients could perform their daily activities without problems. The mean spectacle independence scores for reading, doing computer work, and for distance were 10.33 ± 12.47, 5.71 ± 11.90, and 3.92 ± 9.77, respectively (scale: 0 = no spectacles needed; 40 = spectacles always needed). No correlation was found between spectacle independence and visual outcome (-0.101 ≤ r ≤ 0.244, p ≥ 0.087). Mean scores (0 = no symptoms; 40 = strong symptoms) for glare at night, ghost images, and halos were 15.15 ± 12.02, 4.49 ± 7.92, and 13.34 ± 10.82, respectively. No correlation was found between photic phenomena and visual outcome (-0.199 ≤ r ≤ 0.209, p ≥ 0.150). A total of 80% of patients reported satisfaction with the surgery outcome, and 86% would recommend the surgery to friends and family. CONCLUSIONS: Implantation of the AT LISA tri 839MP IOL after cataract surgery provides effective visual restoration associated with a minimal level of photic phenomena, a positive impact on the performance of vision-related daily activities, and a high level of postoperative patient satisfaction.


Asunto(s)
Femenino , Humanos , Masculino , Persona de Mediana Edad , Extracción de Catarata/métodos , Anteojos , Estudios de Seguimiento , Implantación de Lentes Intraoculares/métodos , Satisfacción del Paciente , Lentes Intraoculares Fáquicas , Estudios Prospectivos , Diseño de Prótesis , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Encuestas y Cuestionarios , Agudeza Visual
3.
Indian J Ophthalmol ; 2011 Nov; 59(6): 481-485
Artículo en Inglés | IMSEAR | ID: sea-136232

RESUMEN

There are few studies on pseudophakic monovision even though it is widely applied. We reviewed the published literature on pseudophakic monovision. Surgeons select patients who not only have a strong desire to be free of glasses after surgery, but also fully understand monovision design and its drawbacks. However, other criteria adopted for pseudophakic monovision are very different. Both traditional monovision and cross monovision are used in pseudophakic monovision, and the target binocular anisometropia ranges from –1.0 D to –2.75 D. Postoperative results were acceptable in every study and most patients were satisfied, with vision being improved and presbyopia corrected. Complications were decreased stereopsis, contrast sensitivity, and visual fields, similar to other types of monovision. The term “pseudophakic monovision” should include more than just monocular intraocular lens implantation in two eyes, and further studies are required.


Asunto(s)
Catarata , Anteojos , Humanos , Implantación de Lentes Intraoculares , Presbiopía/cirugía , Seudofaquia/fisiopatología , Visión Monocular
4.
Clinics ; 65(5): 459-468, 2010. tab
Artículo en Inglés | LILACS | ID: lil-548625

RESUMEN

OBJECTIVES: To assess the influence of Nd:YAG (neodymium: yttrium-aluminum- garnet) laser unilateral posterior capsulotomy on visual acuity and patients' perception of difficulties with vision-related activities of daily life. METHODS: We conducted an interventional survey that included 48 patients between 40 and 80 years of age with uni- or bilateral pseudophakia, posterior capsule opacification, and visual acuity <0.30 (logMAR) in one eye who were seen at a Brazilian university hospital. All patients underwent posterior capsulotomy using an Nd:YAG laser. Before and after the intervention, patients were asked to complete a questionnaire that was developed in an exploratory study. RESULTS: Before posterior capsulotomy, the median visual acuity (logMAR) of the included patients was 0.52 (range 0.30-1.60). After posterior capsulotomy, the median visual acuity of the included patients improved to 0.10 (range 0.0-0.52). According to the subjects' perceptions, their ability to perform most of their daily life activities improved after the intervention (p<0.05). CONCLUSIONS: After patients underwent posterior capsulotomy with an Nd:YAG laser, a significant improvement in the visual acuity of the treated eye was observed. Additionally, subjects felt that they experienced less difficulty performing most of their vision-dependent activities of daily living.


Asunto(s)
Adulto , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Actividades Cotidianas , Opacificación Capsular/cirugía , Extracción de Catarata/métodos , Terapia por Láser/métodos , Cápsula del Cristalino/cirugía , Agudeza Visual/fisiología , Brasil , Estudios Transversales , Opacificación Capsular/fisiopatología , Extracción de Catarata/efectos adversos , Láseres de Estado Sólido/uso terapéutico , Seudofaquia/fisiopatología , Seudofaquia/cirugía , Calidad de Vida , Encuestas y Cuestionarios , Resultado del Tratamiento
5.
Arq. bras. oftalmol ; 68(4): 439-443, jul.-ago. 2005. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-417781

RESUMEN

OBJETIVO: Avaliar a sensibilidade ao contraste e a acuidade estereoscópica em pacientes pseudofácicos, que receberam implante bilateral de lente intra-ocular multifocal. MÉTODOS: Prospectivamente foram realizados testes de sensibilidade ao contraste com o uso da tabela Pelli-Robson e teste de acuidade estereoscópica com emprego do Titmus Stereo Test, em 20 pacientes com implante bilateral de lente intra-ocular multifocal Acrysof Restor®, no pós-operatório de 1 a 2 meses e sem uso de qualquer correção óptica. RESULTADOS:O teste de sensibilidade ao contraste binocular demonstrou que 6 pacientes (30 por cento) apresentaram 1,80 unid. log, 13 (65 por cento) 1,65 e 1 (5 por cento) 1,50. No teste monocular, ocorreram as seguintes respostas: 17 pacientes (85 por cento) 1,65 unid. log e 3 (15 por cento) 1,50 para o teste do olho direito. O teste do olho esquerdo mostrou que 16 pacientes (80 por cento) apresentaram 1,65 unid. log e 4 (20 por cento) 1,50. A média e o desvio-padrão da sensibilidade ao contraste testada binocularmente foi 1,69 (±0,08), ao passo que monocularmente foi 1,63 (±0,05) para OD e 1,62 (±0,06) para OE. O teste de acuidade estereoscópica revelou que 12 pacientes (60 por cento) obtiveram 40", 6 (30 por cento) 50" e 2 (10 por cento) 60", com média de 45" e desvio-padrão de ±6,88". CONCLUSAO: A lente intra-ocular empregada no estudo, proporcionou resultados de sensibilidade ao contraste e acuidade estereoscópica compatíveis e de acordo com critérios de normalidade estabelecidos anteriormente por outros estudos em grupos de pacientes fácicos e pseudofácicos, e portanto, impacto positivo na funcionalidade visual.


Asunto(s)
Humanos , Persona de Mediana Edad , Percepción de Profundidad/fisiología , Seudofaquia/fisiopatología , Sensibilidad de Contraste/fisiología , Extracción de Catarata , Estudios de Seguimiento , Implantación de Lentes Intraoculares , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA