Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Cienc. tecnol. salud ; 9(1): 82-97, 2022. il 27
Artículo en Inglés | LILACS, DIGIUSAC, LIGCSA | ID: biblio-1390741

RESUMEN

White cement-based mortars in urban areas are usually discolored and altered their esthetic properties due to air pollutants. The addition of nanoparticles in these mortars can provide photocatalytic properties that can decompose pollution agents. Likewise, other hydrophobic agents have been individually studied to improve outdoor building constructions. Therefore, this study presented the photocatalytic and hydrophobic effect of adding nano-TiO2and silicone hydrophobic powder (DOWSILTM) in a white cement matrix. The nano-TiO2 were characterized by X-Ray Diffraction (XRD); afterwards, the mortar was mixed with additions of nano-TiO2 (0.0, 0.5, 1.0, 3.0%) and DOWSILTM (0.0, 0.5%). The mortar's photocatalytic performance was evaluated using a modification of the standard Italian test Ente Nazionale Italiano di Unificazione 11259:2016 based on Rhodamine B (RhB) degradation on the sample exposed to UV irradiation. Therefore, mortar samples were subjected to UV irradiation to degrade the organic dye rhodamine B, monitoring their color variation using a C I E L* a* b* spectrophotometer. Moreover, the water permeability and the contact angle were evaluated. This research demonstrates that the white cement-based mortar samples added with nano-TiO2/DOWSILTM possess photocatalytic activity. The samples with the addition of 1.0%/0.5% and 3.0%/0.5% nano-TiO2/DOWSILTM showed a higher RhB degradation for R4 and R26. Therefore, these two materials can be employed in these proportions to improve the quality of the white cement-based mortars in urban constructions.


Los morteros a base de cemento blanco generalmente se decoloran y alteran sus propiedades estéticas debido a los contaminantes del aire en las áreas urbanas. Nanopartículas añadidas a estos morteros pueden proporcionar propiedades fotocatalíticas que descomponen estos contaminantes. Asimismo, otros agentes hidrofóbicos se han estu-diado individualmente para mejorar las construcciones a la intemperie. Por lo tanto, se presenta el efecto fotocatalítico e hidrofóbico al incorporar nano-TiO2 y silicona hidrofóbica de polisiloxano (DOWSILTM) en una matriz de cemento blanco. El nano-TiO2 se caracterizó por medio de Difracción de Rayos X (DRX); luego, el mortero se mezcló con adiciones de nano-TiO2 (0.0, 0.5, 1.0, 3.0%) y DOWSILTM (0.0, 0.5%). Los morteros se sometieron a irradiación UV, para degradar el colorante orgánico rodamina B, monitoreando su variación de color usando un espectrofotómetro C I E L* a* b*. La eficiencia fotocatalítica del mortero se evaluó utilizando una modificación de la norma italiana Ente Nazionale Italiano di Unificazione 11259:2016 basada en la degradación de la rodamina B (RhB) en el mortero expuesto a la radiación UV. Además, se evaluó la permeabilidad al agua y el ángulo de contacto. Esta investigación demostró que el mortero de cemento con nano-TiO2/ DOWSILTM posee actividad fotocatalítica. Las muestras con 1.0%/0.5% y 3.0%/0.5% nano-TiO2/DOWSILTM mostraron una mayor eficiencia de degradación de RhB para R4 y R26. Por lo tanto, estos materiales tienen potencial para mejorar la calidad de los morteros en construcciones urbanas.


Asunto(s)
Contaminantes Atmosféricos , Absorción , Nanopartículas , Permeabilidad , Siliconas/análisis , Titanio/análisis , Materiales de Construcción/análisis
2.
Rev. bras. cir. plást ; 32(2): 291-294, 2017. ilus
Artículo en Inglés, Portugués | LILACS | ID: biblio-847449

RESUMEN

Durante muitos anos, os implantes de silicone foram utilizados em cirurgias reconstrutivas e estéticas, principalmente em casos em que o perfil facial do paciente apresenta deficiência no terço inferior da face. Este material tem provado ser bem sucedido na maioria dos aspectos, contudo, algumas complicações já foram bem relatadas na literatura, como é o caso das reabsorções ósseas na região de mento mandibular. No presente artigo os autores apresentam dois casos clínicos de reabsorção óssea da cortical anterior do mento, associada ao implante de silicone e discutem a etiologia, as complicações e o plano de tratamento.


For many years, silicone implants were used in reconstructive and esthetic surgeries, especially in cases in which the facial profile of patients presented deficiencies in the inferior third of the face. This material proved to be successful in most aspects. However, several complications were well reported in the literature, as the case of bone reabsorption in the region of the mandibular chin. In this article, the authors present two clinical cases of bone reabsorption from the anterior cortex of the chin associated with silicone implants and discuss the etiology, complications, and treatment plan.


Asunto(s)
Humanos , Femenino , Niño , Persona de Mediana Edad , Historia del Siglo XXI , Siliconas , Resorción Ósea , Mentoplastia , Siliconas/análisis , Siliconas/toxicidad , Resorción Ósea/cirugía , Mentoplastia/métodos
3.
Prosthes. Lab. Sci ; 6(21): 38-44, 2016. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: biblio-837401

RESUMEN

Na prática odontológica, o vazamento de gesso nos moldes é muitas vezes tardio, e a maioria é enviada ao laboratório para verter o gesso em até 72 horas. Portanto, os profissionais devem ficar cientes do tempo de atraso tolerável para o qual o material de moldagem permanecerá dimensionalmente preciso. O objetivo deste estudo foi avaliar a alteração dimensional de quatro marcas comerciais de silicone por reação de condensação: Speedex (Vigodent)®, Coltex/Coltoflax (Vigodent)®, Clonage (Nova DFL)® e Zetaplus/Oranwash (Zhermack)®, em função de seis diferentes tempos de vazamento de gesso, e sugerir o tempo máximo de armazenagem dos moldes. Para isso, foi confeccionado um modelo mestre com três cilindros metálicos, fixados em região de rebordo alveolar de uma maxila em acrílico, e 12 moldeiras individuais. A técnica de moldagem utilizada foi a do material em consistência densa e fluida em dois estágios. foram obtidos 72 modelos em gesso GC fujirock® EP melhorado tipo IV, os quais foram mensurados com paquímetro digital Mytutoyo®. Os resultados foram comparados ao modelo controle e aplicados ao teste de hipóteses "t de student". Concluiu-se que as marcas comerciais de silicone por reação de condensação Zetaplus® e Clonage® apresentaram modelos experimentais que não diferiram estatisticamente do modelo mestre para todos os tempos estudados. Já as marcas comerciais Coltex Coltoflax® e Speedex® apresentaram-se estatisticamente diferentes ao modelo mestre nos maiores tempos de armazenamento.


In dental practice, plaster casting is often late, and most are sent to the laboratory to pour the plaster in up to 72 hours. Therefore professionals should be aware of the tolerable delay time for which the molding material will remain dimensionally accurate. The objective of this study was to evaluate the dimensional alteration of four commercial brands of silicone by condensation reaction, Speedex (Vigodent)®, Coltex / Coltoflax (Vigodent)®,Clonage (Nova DFL)®, Zetaplus / Oranwash (Zhermack)®, in function of six different casting times, and suggest the maximum storage time of the molds. Therefore, a master model with three metal cylinders was made, fixed in the alveolar ridge region of an acrylic jaw, and 12 individual trays. The technique of molding used was that of the material in dense consistency and fluid in two stages. A total of 72 GC fujirock® EP improved plaster models were obtained, which were measured using a Mytutoyo® digital caliper. The results were compared to the control model and the "t student" hypothesis test was applied. It was concluded that the trademarks of silicone by condensation reaction Zetaplus® and Clonage® presented experimental models that did not differ statistically from the master model for all the studied times. Coltex Coltoflax® and Speedex® trademarks were statistically different from the master model in the longest storage times.


Asunto(s)
Humanos , Materiales de Impresión Dental , Materiales Dentales , Precisión de la Medición Dimensional , Elastómeros de Silicona , Siliconas/análisis
4.
Säo Paulo; s.n; 1999. 95 p. ilus, tab.
Tesis en Portugués | LILACS, BBO | ID: lil-246737

RESUMEN

A finalidade da pesquisa foi determinar a recuperaçäo elástica, por meio de um elasticímetro, de 4 siliconas de massa (Aquasil, Express, President e Provil), misturadas sob 12 combinaçöes com luvas usadas sem ou com lavagem e uso ou näo de espátula para mistura inicial. Também foram determinados os tempos até alcançar recuperaçäo elástica 100 por cento, quando isto é possível. As conclusöes foram: cada silicona apresenta um comportamento diferente; a Aquasil comportou-se bem sob todas as combinaçöes; a Express falhou sem uso de espátula, com a luva Safederm; a President falhou com a luva Satari sem lavar e sem uso de espátula; a Provil falhou com as luvas Safederm e Satari sem uso de espátula; em dúvida do comportamento dos materiais, o profissional deve usar a espátula para a mistura inicial


Asunto(s)
Elasticidad , Siliconas/análisis , Materiales Dentales
5.
Rev. odontol. Univ. Säo Paulo ; 11(2): 93-7, abr.-jun. 1997. tab
Artículo en Portugués | LILACS, BBO | ID: lil-192836

RESUMEN

Os autores pesquisaram três marcas comerciais de silicones acéticos de fabricaçäo nacional e os submeteram a testes de dureza "Shore A" e de resistência ao rasgamento, com o objetivo de verificar qual proporçäo desses materiais misturados ao silicone Silastic 4-4210 mais se aproximaria dos valores considerados ideiais para as propriedades físicas dos silicones. Concluíram que, à medida em que a quantidade de Silastic 4-4210 era aumentada, as características físicas dos silicones acéticos estudados pioravam. Estes, porém, possuem certas vantagens sobre os materiais "in natura", em funçäo da maior sensaçäo de textura de pele natural e da maior liberdade de escolha do profissional quanto às qualidades desejadas para a confecçäo de próteses faciais


Asunto(s)
Siliconas/análisis , Siliconas/uso terapéutico , Prótesis Maxilofacial/rehabilitación , Prótesis Maxilofacial/tendencias , Pruebas de Dureza , Fenómenos Físicos
6.
RPG rev. pos-grad ; 3(2): 142-7, abr.-jun. 1996. tab
Artículo en Portugués | LILACS, BBO | ID: lil-197589

RESUMEN

Os autores selecionaram três marcas comerciais de silicones acéticos mais encontrados no mercado nacional e os submeteram a teste de alteraçäo dimensional, alongamento de ruptura e resistência à traçäo, com o fito de verificar qual proporçäo desses materiais misturados ao silicone Silastic 4-4210, de procedência norte-americana, mais se aproximaria dos valores considerados ideais para as propriedades físicas dos mesmos. Concluíram que os silicones estudados se comportam de modo semelhante e, à medida que a quantidade de Silastic 4-4210 é aumentada, observa-se uma piora nas características físicas dos materiais


Asunto(s)
Ensayo de Materiales , Prótesis Maxilofacial , Siliconas/administración & dosificación , Siliconas/análisis
7.
In. Feller, Christa; Bottino, Marco Antonio. Atualizaçäo na clínica odontológica: a prática da clínica geral. s.l, Artes Médicas, 1994. p.281-93, ilus. (BR).
Monografía en Portugués | LILACS, BBO | ID: lil-187706
8.
Rev. paul. odontol ; 13(4): 8-16, jul.-ago. 1991. ilus, tab
Artículo en Portugués | LILACS, BBO | ID: biblio-858755

RESUMEN

Os autores procuraram verificar a estabilidade dimensional de um material de moldagem de alta precisão, no caso a silicona de condensação, frente a três fatores: alivio ou não da silicona densa, meio de estocagem (imerso em água e água confinada), e tempo de armazenamento


Asunto(s)
Materiales de Impresión Dental/análisis , Siliconas/análisis
9.
Bauru; s.n; 1991. 160 p. ilus.
Tesis en Portugués | LILACS, BBO | ID: lil-222752

RESUMEN

Este estudo foi desenvolvido para verificar as alteraçöes dimensionais em sete diferentes marcas comerciais de gesso, sendo seis do tipo IV e uma do tipo III, quando provenientes de moldes de uma silicona de adiçao comumente encontrada em nosso mercado (Provil H). Foram realizados inicialmente 70 troquéis de gesso, 10 para cada marca comercial, utilizando-se um dispositivo especial para moldagem e análise dos desajustes desenvolvido por ARAÚJO; JORGENSEN 4, em 1985. Os desajustes foram medidos através de um anel de mediçäo em microscópio de profundidade, onde foram encontradas diferenças entre os materiais empregados. Numa segunda fase, 42 novos troquéis receberam ceroplastia e peças fundidas em ligas de níquel cromo foram obtidas, os desajustes foram medidos agora sobre o troquel padräo de aço, sem que estas sofressem qualquer tipo de usinagem, identificando peças provenientes de gesso mais preciso (Vel-Mix) um menor desajuste, e peças provenientes do Herostone um maior desajuste


Asunto(s)
Sulfato de Calcio/análisis , Materiales de Impresión Dental/análisis , Rehabilitación Bucal/métodos , Siliconas/análisis
10.
Rev. odontol. Univ. Säo Paulo ; 4(3): 212-5, jul.-set. 1990. ilus, tab
Artículo en Inglés | LILACS, BBO | ID: biblio-858613

RESUMEN

Moldagens de um modelo confeccionado em aço inoxidável com o formato de um dente preparado para coroa total foram feitas, a 37ºC, utilizando-se uma silicona de adição (Presidente R.). Dois tamanhos de moldeira foram utilizados, uma para obter uma camada de material de moldagem de 1 mm de espessura, na região gengival do preparo e outra para obter uma camada de 4 mm. O modelo padrão de aço, podia apresentar retenções para apical da margem gengival, conforme descrito anteriormente, permitindo variar a profundidade de retenção em 0,5 ou 1,5 mm. Troquéis de gesso eram obtidos: 1) após resfriar os moldes a 22ºC por 10 minutos e 2) após resfriar os moldes a 22ºC por 10 minutos e posteriormente reaquecê-los a 37ºC, por 30 minutos. Os resultados mostraram que reaquecer os moldes à temperatura da boca melhora a precisão dos moldes e que as retenções têm uma influência definida mas pequena sobre a precisão dos moldes de silicona de adição


Asunto(s)
Materiales de Impresión Dental , Siliconas/análisis , Técnicas In Vitro
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA