1.
An. bras. dermatol ; 91(3): 262-273, tab, graf
Artículo en Inglés | LILACS | ID: lil-787290

RESUMEN

Abstract: Ultrasonography is a method of imaging that classically is used in dermatology to study changes in the hypoderma, as nodules and infectious and inflammatory processes. The introduction of high frequency and resolution equipments enabled the observation of superficial structures, allowing differentiation between skin layers and providing details for the analysis of the skin and its appendages. This paper aims to review the basic principles of high frequency ultrasound and its applications in different areas of dermatology.


Asunto(s)
Humanos , Piel/diagnóstico por imagen , Ultrasonografía Doppler/métodos , Dermatología/métodos , Piel/fisiopatología , Enfermedades Cutáneas Infecciosas/diagnóstico por imagen , Neoplasias Cutáneas/diagnóstico por imagen , Transductores/normas , Ultrasonografía Doppler/instrumentación , Ultrasonografía Doppler/tendencias , Dermatología/instrumentación , Inflamación/diagnóstico por imagen
2.
Clinics ; 71(3): 140-144, Mar. 2016. graf
Artículo en Inglés | LILACS | ID: lil-778991

RESUMEN

OBJECTIVE: The assessment of fracture union includes physical examination and radiographic imaging, which depend on the examiner’s experience. The development of ancillary methods may avoid prolonged treatments and the improper removal of implants. Quantitative bone ultrasonometry has been studied for this purpose and will soon be included in clinical practice. The aims of the present study were to assess the feasibility of using this technique on the clavicle and to standardize its in vivo application. METHODS: Twenty adult volunteers, including 10 men and 10 women without medical conditions or a previous history of clavicle fracture, underwent axial quantitative ultrasonometric assessment using transducers in various positions (different distances between the transducers and different angulations relative to the clavicle). RESULTS: Similar values of wave propagation velocity were obtained in the different tested set-ups, which included distinct distances between the transducers and angular positions relative to the clavicle. There were significant differences only in the transducers positioned at 0° and at 5 or 7 cm apart. CONCLUSIONS: The use of bone ultrasonometry on the clavicle is feasible and the standardization of the technique proposed in this study (transducers placed at 45° and at 7 cm apart) will allow its future application in clinical trials to evaluate the healing process of diaphyseal fractures of the clavicle.


Asunto(s)
Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Clavícula , Huesos , Estudios de Factibilidad , Estándares de Referencia , Transductores/normas , Ondas Ultrasónicas
3.
Rev. bras. eng. biomed ; 26(1): 11-24, abr. 2010. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-570335

RESUMEN

Este trabalho teve por objetivo o desenvolvimento e avaliação da eficácia de um protocolo de controle de qualidade de imagens geradas por equipamentos de ultrassom operando no modo B, que fosse de fácil implementação e que utilizasse um único objeto de testes. O protocolo proposto foi avaliado em 25 equipamentos de ultrassom utilizados em medicina obstétrica, ginecologia e clínica médica, selecionados em várias clínicas e hospitais de Curitiba, Brasil. Somente modelos de equipamentos que suportavam os três tipos padrões de transdutores (convexo, linear e endocavitário) foram incluídos nos testes. No entanto, em alguns dos equipamentos, nem todos os transdutores estavam disponíveis, totalizando 72 transdutores avaliados durante os testes. Um objeto de testes de uso geral foi utilizado para avaliar os seguintes parâmetros: resoluções laterais e axiais, profundidade de visualização e exatidão das distâncias medidas, entre outras. O protocolo foi implementado em duas partes: uma envolvendo a inspeção física do equipamento/monitor e outra para avaliação dos transdutores. Entre os resultados obtidos, pode-se destacar a efetividade e simplicidade do protocolo proposto, o qual é completamente baseado em um único objeto de testes. Considerando as normas e relatórios técnicos utilizados, para aproximadamente 86% dos transdutores avaliados, falhas foram detectadas em um ou mais indicadores de qualidade de imagem. Os resultados obtidos estão de acordo com outros estudos realizados no Brasil, mostrando que um grande número de equipamentos utilizados diariamente em clínicas e hospitais apresenta um ou mais parâmetros fora dos limites estabelecidos em normas técnicas, tornando difícil o diagnóstico médico e, consequentemente, submetendo o paciente a riscos.


This study aims the development of a quality control protocol of images generated by B-mode ultrasound equipment, being of simple implementation and making use of a single phantom, as well as the evaluation of the proposed protocol effectiveness. The proposed protocol was evaluated on 25 ultrasound equipment used in obstetric medicine, gynaecology and medical clinic, selected from several clinics and hospitals of Curitiba, Brazil. Only systems with three standard transducers (convex, linear and endocavitary types) should be selected, however for some units not all of them were available, thus a total of 72 transducers were tested. A general purpose phantom was used to evaluate the following parameters: lateral and axial resolution, deepness of visualization and accuracy between distances, among others. The protocol was implemented in two parts: one involving the physical inspection of the equipment/monitor and another for the transducers evaluation. Among the results obtained, one is highlighted by the effectiveness and simplicity of the proposed protocol, which is completely based on a single phantom. Considering the utilized standards and technical reports, for approximately 86% of the evaluated transducers, some kind of failure or problem was detected in one or more image quality indicators. The results, inaccordance to those obtained by other authors in Brazil, showed that agreat number of equipment used daily in clinics and hospitals present one or more parameters out of the standards, making the medical diagnosis difficult and consequently submitting the patient to risks.


Asunto(s)
Análisis de Falla de Equipo/instrumentación , Análisis de Falla de Equipo/métodos , Análisis de Falla de Equipo/normas , Técnicas de Diagnóstico Obstétrico y Ginecológico/instrumentación , Técnicas de Diagnóstico Obstétrico y Ginecológico/normas , Ultrasonografía/instrumentación , Ultrasonografía/normas , Control de Calidad , Equipos y Suministros de Hospitales/normas , Errores Diagnósticos/prevención & control , Falla de Equipo , Estándares de Referencia , Seguridad de Equipos/instrumentación , Transductores/normas
4.
Rev. bras. eng. biomed ; 24(1): 39-49, abr. 2008. ilus, graf
Artículo en Portugués | LILACS | ID: lil-510113

RESUMEN

No método de calibração por auto-reciprocidade, a sensibilidade do transdutor é determinada a partir do conhecimento de parâmetros elétricos de excitação do transdutor (tensão e corrente), além de outras grandezas presentes no parâmetro geral de reciprocidade para ondas planas JP. O objetivo deste trabalho é validar um sistema de calibração por auto-reciprocidade, conforme a norma IEC 60866:1987. A validação foi realizada utilizando-se um padrão de referência calibrado no National Physical Laboratory (NPL) em conjunto com transdutores com freqüência central de 1,0 MHz e 2,25 MHz. Para a validação do sistema de calibração, a tensão de alimentação aplicada aos transdutores foi variada de 1 a 10 V, medidos pico a pico, na faixa de 0,80 a 1,32 MHz para o transdutor de 1,0 MHz e na faixa de 1,5 a 3,0 MHz para o transdutor de 2,25 MHz. Foram considerados válidos os pontos em freqüência cujos resultados da calibração tiveram incerteza devido à linearidade máxima menor do que 10% e incerteza combinada menor do que 9%. O sistema foi validado na faixa de 1,04 a 1,32 MHz (com base nos resultados do transdutor de 1,0 MHz) e na faixa 1,55 a 2,90 MHz (utilizando-se o transdutor de 2,25 MHz). Nas freqüências próximas à freqüência de ressonância, a incerteza combinada típica do transdutor de 1,0 MHz foi de cerca de 5%, e a do transdutor de 2,25 MHz em torno de 8%. A faixa reduzida do primeiro transdutor deu-se por restrições do sistema experimental utilizado, particularmente pelos dados de calibração do padrão de referência utilizado. O sistema se mostrou adequado e os resultados foram considerados dentro do padrão esperado.


According to the self-reciprocity calibration method, ultrasonic transducer sensitivity is depicted from the knowledge of electrical parameters of excitation (voltage and electric current), as well as other quantities expressed in the general reciprocity parameters for plane waves...


Asunto(s)
Transductores/normas , Ultrasonido , Ultrasonografía , Calibración/normas , Mantenimiento de Equipo/métodos , Control de Calidad , Estándares de Referencia
5.
Rev. bras. eng. biomed ; 23(3): 277-292, dez. 2007. ilus, tab, graf
Artículo en Portugués | LILACS | ID: lil-507733

RESUMEN

O presente trabalho consta de uma revisão minuciosa dos métodos de calibração de hodrofones, aplicáveis tanto aos do tipo agulha quanto aos de membrana. São revistos os métodos mais utilizados, absolutos e por comparação, associados às diversas técnicas de calibração e destinadas à determinação da sensibilidade do hidrofone. Os métodos descritos são: Reciprocidade, Varredura Plana, Interferometria a laser, TDS (Time Delay Spectrometry) e da Propagação Não Linear ou da Geração de Harmônicos. É apresentado um quadro comparativo descrevendo a incerteza típica e a máxima freqüência ultra-sônica inerentes a cada um dos métodos. A calibração de hidrofones com base no Método da Reciprocidade tem incerteza típica de cerca de mais ou menos 19 por cento (1,5dB) entre 0,5 e 15 MHz. Com o Método da Varredura Plana, a incerteza é de cerca de mais ou menos 6 por cento (0,5 dB) até 5 MHz, ou mais ou menos 15 por cento (1,2 dB) até 70 MHz. Para o Método TDS, as incertezas estão em torno de mais ou menos 7 por cento (0,7 dB) até 5 MHz e de mais ou menos 14 por cento (1,1 dB) até 30 MHz. Atualmente, o método interferométrico é considerado o melhor, mas não é de largo emprego devido ao seu alto custo de implementação.


Asunto(s)
Calibración , Transductores/normas , Transductores , Ultrasonido , Control de Calidad , Estándares de Referencia , Seguridad de Equipos/métodos , Seguridad de Equipos/normas
6.
JCPSP-Journal of the College of Physicians and Surgeons Pakistan. 1996; 6 (3): 181-2
en Inglés | IMEMR | ID: emr-95978

RESUMEN

An improved method of using stand-off gel pad for diagnostic ultrasound scan is described, as an alternate to the use of high frequency probes or the use of Linear probe while using it with Convex probe


Asunto(s)
Geles/normas , Transductores/normas