Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Ginecol. obstet. Méx ; 88(5): 296-305, ene. 2020. tab, graf
Article Dans Espagnol | LILACS-Express | LILACS | ID: biblio-1346191

Résumé

Resumen: OBJETIVO: Evaluar y comparar la adaptación cardiovascular materna mediante variables antropométricas y parámetros hemodinámicos con ecocardiografía Doppler en mujeres mexicanas sanas, con embarazo único. MATERIALES Y MÉTODOS: Estudio prospectivo, observacional, longitudinal, efectuado de enero de 2014 a enero de 2017 en mujeres que cursaban el segundo y tercer trimestres del embarazo. A los 6 meses posparto se practicaron ecosonogramas obstétricos y registros ecocardiográficos Doppler a todas las pacientes del estudio. Cada paciente fue su propio control. Se aplicó el análisis estadístico con SPSS Windows v17, ANOVA para comparar los 3 grupos, con valor significativo de p < 0.05, y correlación no paramétrica de Pearson. RESULTADOS: Se estudiaron 30 embarazadas con edad promedio de 22.5 ± 3.1 años. Las semanas de embarazo se corroboraron con ultrasonido obstétrico. En el ecocardiograma transtorácico se observaron cambios significativos entre el segundo trimestre y los 6 meses posparto: el ventrículo izquierdo en diástole (cm), 4.5 ± 2.5 vs 4.2 ± 3.3, p < 0.01. El volumen diastólico final del ventrículo izquierdo (mL) fue de 93 ± 14.8 vs 78 ± 17.8 (p < 0.05), el volumen latido (mL): 99.5 ± 15.7 vs 86 ± 11.8 (p < 0.01). Las resistencias vasculares sistémicas (dinas/seg/cm-5), 870 ± 108 vs 1262 ± 176 (p < 0.01). Del segundo al tercer trimestres y posnatal hubo incrementos en la aurícula izquierda (cm): 3.1 ± 4.6, 3.3 ± 4.4, 2.9 ± 4.3 (p < 0.001), gasto cardiaco (L/m): 6.8 ± 0.4, 7.0 ± 0.4, 4.7 ± 0.4 (p < 0.001). CONCLUSIONES: El embarazo es un estado de sobrecarga transitoria de volumen con importantes efectos orgánicos y funcionales, sobre todo en el segundo trimestre.


Abstract: OBJECTIVE: The aim of this prospective, observational and longitudinal study, was to evaluate and to compare the maternal adaptation through changes on anthropometric and Doppler echocardiographic parameters in Mexican normal pregnancy with single product. MATERIALS AND METHODS: Prospective, observational, longitudinal study, from January 2014 to January 2017. Obstetric ecosonograms and echocardiographic Doppler studies were performed on 2nd and 3rd trimester and six months postpartum. Each patient was her own control. The data were analyzed using SPSS Windows 17, ANOVA for compared the 3 groups with P value < 0.05 was considered significant, as well as a non-parametric correlation of Pearson. RESULTS: There were thirty pregnant with a mean age 22.5 ± 3.1 years-old, between 2nd and 3rd trimester, with obstetrics ultrasound were corroborated gestational age. With transthoracic echocardiography, we found significant changes between 2nd trimester and 6 month post-partum, among the main, the left ventricle (LV) in diastole (cm), 4.5 ± 2.5 versus 4.2 ± 2.3 (p < 0.01), end diastolic left ventricle volume (mL) 93 ± 14.8, vs 78 ± 17.8 (p < 0.05). Stroke volume (mL) 99.5 ± 15.7 vs 86 ± 11.8 (p < 0.01). Systemic vascular resistance (dyne/sec/cm5 ) 870 ± 108 vs 1,262 ± 176 (p < 0.001). From, 2nd and 3rd trimester and postpartum, left atrial diameter (cm), 3.1 ± 4.4, 3.3 ± 4.4, 2.9 ± 4.3 (p < 0.001). Cardiac output (L/m), 6.8 ± 0.4, 7.0 ± 0.4, 4.7 ± 0.4 (p < 0.001). CONCLUSION: Pregnancy is a transitory overload condition with important organic and functional effects mainly in the second trimester.

2.
Ginecol. obstet. Méx ; 63(5): 196-8, mayo 1995.
Article Dans Espagnol | LILACS | ID: lil-151908

Résumé

Se presenta un caso poco usual de una mujer de 36 años, multigesta, portadora de triple protésis mecánica cardiaca, anticoagulada con cumarínicos, que evolucionó en su sexta gestación sin complicaciones cardiovasculares, obteniendo un recién nacido, con peso de 1,700 g. sin malformaciones. Se discuten los problemas de manejo, seguimiento y resolución del embarazo así como los factores que influyen en un resultado óptimo para el binomio materno-fetal


Sujets)
Grossesse , Nouveau-né , Adulte , Humains , Femelle , Anticoagulants/administration et posologie , Anticoagulants/usage thérapeutique , Retard de croissance intra-utérin/diagnostic , Retard de croissance intra-utérin/étiologie , Complications de la grossesse/chirurgie , Complications de la grossesse/thérapie , Prothèse valvulaire cardiaque/rééducation et réadaptation , Prothèse valvulaire cardiaque
SÉLECTION CITATIONS
Détails de la recherche