Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtre
1.
Braz. J. Pharm. Sci. (Online) ; 58: e19487, 2022. tab, graf
Article Dans Anglais | LILACS | ID: biblio-1394028

Résumé

Abstract Simple, precise, accurate and specific spectrophotometric methods are progressed and validated for concurrent analysis of Furosemide (FUR) and Spironolactone (SPR) in their combined dosage form depend on spectral analysis procedures. Furosemide (FUR) in the binary mixture could be analyzed at its λmax 274 nm using its recovered zero order absorption spectrum using constant multiplication method (CM). Spironolactone (SPR) in the mixture could be analyzed at its λmax 238 nm by ratio subtraction method (RS). Concurrent determination for FUR and SPR in their mixture could be applied by amplitude modulation method (AM), absorbance subtraction method (AS) and ratio difference (RD). Linearity ranges of FUR and SPR were (2.0µg/mL-22.0 µg/mL) and (3.0µg/mL-30.0 µg/mL), respectively. Specificity of the proposed spectrophotometric methods was examined by analyzing the prepared mixtures in laboratory and was applied successfully for pharmaceutical dosage form analysis which have the cited drugs without additives contribution. The proposed spectrophotometric methods were also validated as per as the guidelines of ICH. Statistical comparison was performed between the obtained results with those from the official methods of the cited drugs, using one-way ANOVA, F-test and student t-test. The results are exhibiting insignificant difference concerning precision and accuracy


Sujets)
Spectrophotométrie/méthodes , Spironolactone/antagonistes et inhibiteurs , Préparations pharmaceutiques/administration et posologie , Furosémide/antagonistes et inhibiteurs , Analyse de variance , Formes posologiques , Méthodes
2.
Article Dans Anglais | IMSEAR | ID: sea-163233

Résumé

Aims: A simple RP-TLC Spectrodensitometric method was developed for determination of Hyoscine N-Butyl Bromide (HBB) and Paracetamol (PAR) either in bulk powder or in their pharmaceutical preparation. Study Design: Validation study. Methodology: In this method, HBB and PAR were separated on RP-18 W/ UV254 TLC plates using developing mobile phase consisting of methanol: citrate buffer (pH=1.5): triflouroacetic acid (70:30:0.1, by volume) at room temperature. Experimental conditions such as band size, slit width, different developing systems and scanning wavelength were carefully studied and the optimum conditions were selected. The obtained bands were then scanned at 210 nm. The two drugs were satisfactorily resolved with RF 0.60 ± 0.02 for HBB and 0.81 ± 0.02 for PAR. The validation of spectrodensitometric method was done regarding linearity, accuracy, precision, and specificity. Results: Linearity of the proposed methods was evaluated and it was found to lie within the concentration range of 2.0-12.0 μg.band-1 for HBB and 2.0-14.0 μg.band-1 for PAR. Conclusion: The proposed method was successfully applied for determination of HBB and PAR in pure form and in their different pharmaceutical formulations. The method proved to be specific, accurate and selective.


Sujets)
Acétaminophène/analyse , Acétaminophène/composition chimique , Analgésiques non narcotiques/analyse , Analgésiques non narcotiques/composition chimique , Bromure de N-butyl-scopolammonium/analyse , Bromure de N-butyl-scopolammonium/composition chimique , Chimie pharmaceutique/méthodes , Chromatographie sur couche mince/méthodes , Spectrophotométrie/méthodes
3.
Pakistan Journal of Pharmaceutical Sciences. 2011; 24 (1): 19-23
Dans Anglais | IMEMR | ID: emr-108709

Résumé

Two accurate and sensitive spectrophotometric and spectrofluorimetric methods were developed for determination of Racecadotril. In the first method reduction of Fe3+ into Fe2+ in presence of o-phenanthroline by Racecadotril to form a stable orange-red ferroin chelate [Fe- [Phen][3][2+] was the basis for its determination. The absorbance at 510 nm was measured and linear correlation was obtained in the concentration range of 2.5 - 25 microg mL[-1]. In the second method the native fluorescence of Racecadotril in acetonitril solvent at lambda, = 319 nm when excitation was at 252 nm is used for its determination. Linear correlation was obtained in the concentration range of 50 to 500 ng mL[-1]. The proposed methods were applied for determination of Racecadotril in bulk powder with mean accuracy of 100.39 +/- 1.239 for the spectrophotometric method and 100.09 +/- 1.042 for the spectrofluorimetric method. The proposed methods were successfully applied for determination of Racecadotril in its pharmaceutical dosage form


Sujets)
Spectrométrie de fluorescence , Thiorphan/analogues et dérivés
SÉLECTION CITATIONS
Détails de la recherche