Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 7 de 7
Filtre
Ajouter des filtres








Gamme d'année
2.
Indian Heart J ; 2001 Jul-Aug; 53(4): 467-76
Article Dans Anglais | IMSEAR | ID: sea-6093

Résumé

BACKGROUND: The AutoCapture algorithm as implemented in Regency and Microny pacemakers (Pacesetter Inc., Sylmar, CA, USA) provides beat-by-beat monitoring of capture based on proper detection of the evoked response, provides high output back-up pulse when loss of capture occurs, performs periodic threshold evaluations and acquires the capture threshold data in a time-based event counter for later retrieval. The safety and efficacy of this algorithm was prospectively evaluated at a tertiary care hospital of north India. METHODS AND RESULTS: Fifty-four patients (38 males, mean age 66+/-13 years) received a ventricular pacemaker model Regency SC+ with low polarization bipolar lead for high-grade atrioventricular block (n=42) and sick sinus syndrome (n=12). Evoked response and polarization signal were assessed initially at 24 hours postimplant, and follow-up measurements were systematically conducted at week 1 and months 1, 3 and 6. Further evaluation of eligible patients was performed at 6-monthly intervals. Lead implantation parameters were optimum in all patients. At 6 months, the algorithm was functional in 51 patients. The pacing threshold increased to 0.89+/-0.36 V (p<0.001) in the first month and stabilized thereafter. Significant saving of energy was accomplished by a constant output safety margin of 0.3 V instead of the traditional 100%. While the evoked response signal remained stable throughout the study period, the potential signal increased significantly from 0.6+/-0.7 mV to 1.0+/-0.6 mV (p<0.001) in the first month and remained steady subsequently. Back-up pacing in the event of exit block was confirmed in all 25 patients who underwent a 24-hour Holter test. Based on the suggested sense margins, ventricular undersensing was observed in 7 (28%) patients, the majority of whom had competitive cardiac rhythms. An elderly patient with pneumonic illness succumbed to pulmonary embolism at 6 months. CONCLUSIONS: This large single-center experience on AutoCapture demonstrates the success of this algorithm in low-energy ventricular pacing without compromising the patient's safety.


Sujets)
Adolescent , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Algorithmes , Entraînement électrosystolique/méthodes , Enfant , Potentiels évoqués/physiologie , Femelle , Études de suivi , Bloc cardiaque/physiopathologie , Humains , Mâle , Adulte d'âge moyen , Études prospectives , Seuils sensoriels/physiologie , Maladie du sinus/physiopathologie
3.
Neurol India ; 2001 Mar; 49(1): 87-90
Article Dans Anglais | IMSEAR | ID: sea-121082

Résumé

Carotid angioplasty and stenting is increasingly becoming a safe and efficacious modality of treatment in the management of carotid artery stenosis. Although atherosclerosis is the predominant cause of this morbid disease, Takayasu arteritis assumes special importance in south east Asia. The diffuse nature of this disease with associated inflammation and scarring of the vessel make revascularisation difficult. We report a case of Takayasu arteritis in which a successful bilateral common carotid stenting was done in a single sitting.


Sujets)
Adulte , Angioplastie , Sténose carotidienne/étiologie , Femelle , Humains , Endoprothèses , Maladie de Takayashu/complications
SÉLECTION CITATIONS
Détails de la recherche