Chinese Medical Equipment Journal ; (6): 95-97, 2017.
Article Dans Chinois | WPRIM | ID: wpr-699911

Résumé

Objective To find out the problems in quality control of the hemodialysis machine to ensure its safety.Methods MESA 90XL meter and Austrian RIGFL 288 electrical safety tester were used to detect the hemodialysis machines according to military and national standards on dialysate temperature,dialysate conductivity,venous pressure,arterial pressure,dialysate flow,dialysate pH value,heparin pump flow,blood pump flow,dehydration flow,electrical safety and etc.Results Most of the hemodialysis met the clinical requirements while unqualified machines underwent maintenance,and some measures were proposed to solve the problems during the detection.Conclusion Periodical detection and quality control are of greát significance for the hemodialysis machine.