Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 4 de 4
Filtre
Ajouter des filtres








Gamme d'année
1.
Rev. colomb. cardiol ; 16(6): 256-260, nov.-dic. 2009.
Article Dans Espagnol | LILACS | ID: lil-552609

Résumé

Se presenta el caso de un hombre de setenta y un años de edad quien presenta en forma súbita síntomas y signos isquémicos cerebrales. Tiene antecedente de fibrilación auricular crónica, prótesis valvular en posición aórtica y mitral, insuficiencia cardiaca y complicaciones hemorrágicas relacionadas con la anticoagulación. Como parte del estudio se realizó ecocardiograma transesofágico que demostró trombo mural gigante en la aurícula izquierda, el cual desapareció luego de nueve meses de tratamiento anticoagulante.


The case of a 71 years old male that suddenly presents ischemic brain signs and symptoms is presented. He had a previous history of chronic atrial fibrillation, mitral and aortic valve protheses, heart failure and bleeding related to anticoagulation. A transesophageal echocardiogram was performed as part of the assessment, showing a gigantic left atrial mural thrombus that disappeared after 9 months of anticoagulation therapy.


Sujets)
Prothèse valvulaire cardiaque
2.
Rev. colomb. cardiol ; 16(1): 5-10, ene.-feb. 2009.
Article Dans Espagnol | LILACS | ID: lil-528909

Résumé

El balistocardiograma es el registro del movimiento del cuerpo que se origina por la energía transmitida desde el corazón hacia las grandes arterias como consecuencia de la salida de la sangre desde los ventrículos y del retroceso del cuerpo como reacción. Esta energía causa un desplazamiento del cuerpo en sentido cefálico, para luego cambiar en dirección opuesta cuando la sangre fluye por la aorta descendente. El sistema, que consta de tres partes, una tabla móvil en el sentido horizontal, un sistema de registro del movimiento corporal y un sistema de amplificación, permite generar un registro gráfico. La primera descripción corresponde a Gordon en 1877, cuando registró los movimientos horizontales y verticales de pacientes en una cama suspendida por cuatro cuerdas. En 1905 Yandel Henderson captó los movimientos en sentido horizontal, utilizando una tabla que se balanceaba unida a una serie de poleas; para el registro utilizó un quimógrafo. Pero fue Starr quien le dio el nombre al instrumento y elaboró un balistocardiógrafo indirecto en 1939, que inscribía las ondas en papel fotográfico. Pocos años después, Dock y Taubman diseñaron el primer balistocardiógrafo directo, usando unas barras metálicas ajustadas a las tibias del paciente. Henderson y Bixby mejoraron la precisión de la calibración a través de un microscopio. Autores como Hamilton, Dow, Thompson, Rappaport y Sprague describieron las ondas y su relación con los eventos del ciclo cardiaco. Su correlación con la fonocardiografía y el registro de los pulsos carotídeo, venoso y ápex-cardiograma fue de gran importancia para relacionar las ondas con los eventos fisiológicos. Starr demostró la relación de las ondas con el gasto cardiaco y su utilidad en el seguimiento de pacientes con insuficiencia cardiaca. Luis Carlos Barón Plata, cardiólogo bogotano, diseñó y elaboró un balistocardiógrafo directo, artesanal. Difirió del aparato de Dock y Taubman en la forma de obtener un registro de los movimientos corporales: diseñó un sensor que se colocaba contra la cabeza para registrar así el desplazamiento del cráneo. Con esto registró en forma adecuada las ondas del balistocardiograma. Su construcción fue muy austera y se conectaba mediante dos cables al electrocardiógrafo. Con el desarrollo de métodos más sencillos y precisos para observar y cuantificar la fisiología del corazón, la balistocardiografía perdió popularidad y casi ha desaparecido en todos los servicios de cardiología.


The ballistocardiogram is the registry of the body’s movement generated by the energy transmitted from the heart to the great arteries, as a consequence of the displacement of blood out from the ventricles and the recoil of the body. The energy transmitted cause a displacement in cephalic direction, and change in the opposite direction when the blood flows in the descending aorta. The system is formed by three parts: a mobile board in the horizontal plane, a system to register the corporal movement and an amplification system, to make possible generate a graphical register. The first description was made by Dr. JD. Gordon in 1877, when he registered the horizontal and vertical movements of a patient lying in a bed hanged by four supports. In the year 1905 Dr. Yandel Henderson was able to register the horizontal movements in a hanging panel and a series of pulleys; for the register he used a quimograph. Dr. Isaac Starr assigns the name to the instrument and made an indirect ballistocardiograph in 1939, printing the waves in photographic paper. Few years after, doctors Dock and Taubman designed the first direct ballistocardiograph, using metallic rods adjusted to the patient’s tibia. Henderson and Bixby improved precision of the calibration by the use of a microscope. Authors like doctors Hamilton, Dow, Thompson, Rappaport and Sprague described the waves and their relationship with events of the cardiac cycle. The correlation with phonocardiography and the registry of carotid and venous pulse, and the apexcardiogram, was of great importance to relate the waves with physiological events. Dr. Starr recognized the relationship between the waves and cardiac output and it’s usefulness in the follow-up of patients with heart failure. Luis Carlos Barón Plata, a cardiologist born in Bogotá, designed and handcrafted a direct ballistocardiograph. It differed from Dock and Taubman’s machine in the way of obtaining the corporal movements: he designed a sensor placed in contact with the head in order to record the displacement of the cranium. With this he was able to register adequately the ballistocardiographic waves. The construction was austere and was connected by two cables to the electrocardiograph. With the development of simpler and more accurate methods to observe and quantify the heart’s physiology, the ballistocardiography lost popularity, and that technique has disappeared from almost all the cardiology units.


Sujets)
Débit cardiaque
3.
Rev. colomb. cardiol ; 15(3): 134-138, mayo-jun. 2008. tab
Article Dans Espagnol | LILACS | ID: lil-496786

Résumé

La enfermedad de Fabry es una patología de origen genético que se produce por el depósito, a nivel lisosomal, de diferentes productos como globotriazolceramida, glicoesfingolípidos neurales y diagalactosilceramida a nivel sistémico, como consecuencia de la actividad deficiente de la enzima alfa-galactosidasa A. Las manifestaciones clínicas se inician desde la infancia pero son sutiles y suelen confundirse con otras patologías, razón por la cual en la mayoría de los casos la enfermedad se detecta en grados avanzados. En los adultos los órganos más afectados son corazón, riñones y cerebro. El compromiso cardiaco es de gran importancia por tratarse de una de las principales causas de morbi-mortalidad. El depósito de estas moléculas ocurre en todos sus componentes celulares. Genera hipertrofia e isquemia y remodelación miocárdica, o ambas.En la actualidad existe tratamiento específico con agalasidasa A y B recombinante, con el cual se logra una disminución en los depósitos lisosomales. Se recomienda aumentar la vigilancia de la enfermedad para detectar los casos e iniciar el tratamiento lo más temprano posible.


Sujets)
Cardiomyopathie hypertrophique familiale , Maladie de Fabry , Maladies lysosomiales , Ischémie myocardique
4.
Rev. colomb. cardiol ; 14(2): 93-99, mar-abr. 2007. ilus, tab, graf
Article Dans Espagnol | LILACS | ID: lil-469026

Résumé

Por lo general, el infarto del ventrículo derecho se asocia con infarto de la pared inferior del ventrículo izquierdo. La enfermedad pulmonar obstructiva crónica y la hipertrofia del ventrículo derecho, son factores que lo predisponen. Casi siempre ocurre como consecuencia de obstrucción proximal de la arteria coronaria derecha que conduce a disfunción sistólica y diastólica del ventrículo derecho. El volumen latido disminuye y el volumen diastólico y la presión de llenado del ventrículo derecho aumentan, con lo que se ocasiona hipotensión y congestión periférica. Se disminuyen el flujo sanguíneo pulmonar y el retorno venoso para el ventrículo izquierdo que puede llevar a estado de choque. Además, se pueden presentar complicaciones como bloqueo aurículo-ventricular, disfunción sinusal y aneurisma ventricular.


In general, right ventricular infarction is associated with left ventricular inferior wall infarction. Obstructive chronic pulmonary disease and right ventricular hypertrophy are predisposing factors. It usually occurs as a consequence of proximal obstruction of the right coronary artery, which leads to right systolic and diastolic ventricle dysfunction. Stroke volume is diminished and diastolic volume and right ventricular filling pressure increase, causing hypotension and peripheral congestion. Pulmonary blood flow and left ventricular venous return are diminished, which may lead to shock. Besides, complications such as atrioventricular block, sinus dysfunction and ventricular aneurysm may occur. The electrocardiogram shows ST elevation in leads III, V1 to V3 and in V4R. The echocardiogram shows right ventricular free wall hypokinesis or akinesis and there is right cavities dilation and tricuspid regurgitation. The Doppler shows an increment in the duration of isovolumetric contraction and relaxation intervals; the ejection period is shortened and the myocardial performance index increase to abnormal values. The tissue Doppler is abnormal because of the decrease of systolic velocity in the tricuspid annulus. The optimization of rhythm and heart rate is an important part of treatment, and by this reason, beta-blockers may be avoided; depending on the severity of bradycardia, atropine, aminophylline or transient pace-maker can be used in order to ensure an adequate heart rate. In case of atrial fibrillation, anti-arrhythmic drugs or electric cardioversion may be used. An adequate filling volume may be guaranteed for maintaining the central venous pressure over 15 mm Hg. The use of vasodilators and diuretics is contraindicated. It is important the quick recanalization of the obstructed artery through thrombolisis or angioplastia. If the low cardiac output signs persist, a parenteral inotropic must be used. Intra-aortic balloon pump or mechanic...


Sujets)
Infarctus , Infarctus du myocarde , Choc cardiogénique
SÉLECTION CITATIONS
Détails de la recherche