Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
J. vasc. bras ; 12(2): 180-183, jun. 2013. graf
Article Dans Anglais | LILACS | ID: lil-687322

Résumé

Para-anastomotic aneurysms are either true aneurysms or pseudoaneurysms. The latter tend to be asymptomatic until rupture. Para-anastomotic aneurysms should be approached surgically, despite the high morbidity and mortality associated with their treatment. This report describes the case of a 68-year-old woman who presented with a para-anastomotic pseudoaneurysm secondary to infrarenal aortic aneurysmectomy. We chose to use an endovascular approach, and results were good. Endovascular techniques are increasingly becoming the method of choice in the treatment of anastomotic pseudoaneurysms.


Os aneurismas para-anastomóticos de aorta podem ser verdadeiros ou pseudoaneurismas. Estes últimos tendem a ser assintomáticos até a ruptura. Devem ser tratados cirurgicamente, apesar da alta morbimortalidade em sua abordagem. Este relato descreve o caso de uma paciente do sexo feminino, 68 anos, com quadro de pseudoaneurisma para-anastomótico pós-aneurismectomia de aorta infrarrenal. Optou-se por correção endovascular, com bons resultados. As técnicas endovasculares vêm se estabelecendo como o método de escolha no tratamento dos pseudoaneurismas anastomóticos.


Sujets)
Humains , Femelle , Sujet âgé , Aorte abdominale/physiopathologie , Faux anévrisme/chirurgie , Angiocardiographie/soins infirmiers , Procédures endovasculaires/rééducation et réadaptation
2.
Rev. Assoc. Med. Bras. (1992) ; 57(2): 187-193, mar.-abr. 2011. tab
Article Dans Portugais | LILACS | ID: lil-584071

Résumé

OBJETIVO: Avaliar a prevalência de estenose hemodinamicamente significativa na revascularização infrainguinal realizada com a veia safena magna reversa. MÉTODOS: No período compreendido entre março de 2008 e março de 2009, foram realizadas 56 revascularizações infrainguinais com a veia safena magna reversa em 56 pacientes, dos quais 32 foram avaliados com ultrassonografia vascular no 30º dia de pós- operatório. Foi analisada a prevalência de estenoses significativas nos enxertos e sua relação com as características clínico-cirúrgicas dos pacientes. Os parâmetros avaliados foram a localização das estenoses ao longo do enxerto, fatores de risco associados e a relação existente entre a ultrassonografia vascular e o índice tornozelo-braço no diagnóstico de estenoses. RESULTADOS: Houve prevalência de 48,4 por cento de estenoses significativas nos enxertos avaliados, com 19,4 por cento de estenoses graves e 29 por cento de estenoses leve a moderada. Não foram encontradas associações significativas entre sexo, diabetes mellitus, hipertensão arterial, hipercolesterolemia, diâmetro do enxerto, localização da anastomose distal, composição do enxerto e a constatação de estenoses significativas. Observou-se fraca correlação entre os métodos no diagnóstico das estenoses em geral (K = 0,30; IC95 por cento 0,232-0,473; p = 0,018), mas razoável concordância no diagnóstico das estenoses graves (K = 0,75; IC95 por cento 0,655-0,811; p = 0,0001). CONCLUSÃO: Este estudo demonstrou elevada prevalência de estenoses no 30º dia do pós-operatório, com localização predominante na metade proximal do enxerto. O índice tornozelo-braço e a ultrassonografia vascular apresentaram concordância, sobretudo no diagnóstico das estenoses graves, mas o índice tornozelo-braço, isoladamente, mostrou-se insuficiente na vigilância dos enxertos de veia safena magna reversa.


OBJECTIVE: The aim of this study was to evaluate the prevalence of hemodynamically significant infrainguinal bypasses stenosis using reverse great saphenous vein graft. METHODS: From March of 2008 to March of 2009, 56 infrainguinal bypasses were performed with reverse great saphenous vein graft in 56 patients. On the 30th post-operative day, 32 out of 56 patients were submitted to vascular ultrasonography. The prevalence of significant graft stenosis was determined. In addition, the diagnosis of stenosis was related to the clinical and surgical characteristics of the patients. The variables analyzed at the moment of diagnosis were the localization of the graft stenosis, the risk factors associated with stenosis and the association of vascular ultrasonography findings with ankle brachial pressure index (ABI). RESULTS: The overall prevalence of significant graft stenosis was 48.4 percent. Out of the total number of observed stenosis, 19.4 percent were considered severe, and 29 percent mild or moderate. There was no significant association between the presence of significant stenosis and the following variables: gender, diabetes, hypertension, smoking, hipercholesterolemia, graft diameter, site of the distal anastomosis, and graft composition. There was a weak agreement between ABI and vascular ultrasonography in detecting stenosis in general (K = 0.30; CL95 percent 0.232 - 0.473; p = 0.018). However, there was a substantial agreement in detecting severe stenosis (K = 0.75; CL95 percent 0.655 - 0.811; p = 0.0001). CONCLUSION: There was a high prevalence of stenosis on the 30th post-operative day, mostly localized in the proximal half of the vein graft. There was no significant association of stenosis with clinical and surgical factors analyzed. ABI and vascular ultrasonography had weak agreement with the diagnosis of stenosis in general and an important agreement for the diagnosis of severe stenosis.


Sujets)
Femelle , Humains , Mâle , Sténose pathologique/étiologie , Occlusion du greffon vasculaire/épidémiologie , Veine saphène/transplantation , Index de pression systolique cheville-bras , Artères , Sténose pathologique/épidémiologie , Sténose pathologique , Occlusion du greffon vasculaire/étiologie , Occlusion du greffon vasculaire , Prévalence , Facteurs de risque , Veine saphène , Échographie-doppler duplex
SÉLECTION CITATIONS
Détails de la recherche