Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtre
Ajouter des filtres








Gamme d'année
1.
Chinese Journal of Hematology ; (12): 160-164, 2007.
Article Dans Chinois | WPRIM | ID: wpr-328392

Résumé

<p><b>OBJECTIVE</b>To identify clinical and laboratory abnormalities and genetic defect of Fechtner syndrome in a Chinese family.</p><p><b>METHODS</b>The characteristic morphological features of platelets and leukocytes were examined on blood smears with Wright's-Giemsa staining and ultrastructure of platelet and leukocyte were investigated under electron microscope. Genomic DNA was isolated from peripheral blood of the proband and 9 members of his family. All the exons and exon-intron boundaries of the MYH9 gene were amplified by PCR followed by direct sequencing.</p><p><b>RESULTS</b>Patients presented the characteristic clinical features including macrothrombocytopenia, leukocyte inclusions and/or hereditary nephritis. A heterozygous C to T mutation was found in the proband and three members of his family at nucleotide 5981 in exon 40 of MYH9 gene, resulting in a nonsense mutation which encoded truncated protein due to premature termination at the Arg 1933 codon.</p><p><b>CONCLUSION</b>It is the first report of a Chinese family with Fechtner syndrome. The Arg (CGA) 1933--> stop (TGA) nonsense mutation in MYH9 gene is a causative genetic defect.</p>


Sujets)
Adulte , Humains , Mâle , Codon non-sens , Analyse de mutations d'ADN , Exons , Génétique , Corps d'inclusion , Génétique , Moteurs moléculaires , Génétique , Chaînes lourdes de myosine , Génétique , Néphropathie familiale avec surdité , Génétique , Pedigree , Syndrome , Thrombopénie , Génétique
2.
Chinese Journal of Medical Instrumentation ; (6): 163-166, 2006.
Article Dans Chinois | WPRIM | ID: wpr-355426

Résumé

In order to prove the feasibility of preparation of the drug-incorporated stent by immersing stent wires in the monoclonal antibody (mAb) solution, fluorescence stain and image analysis were used to evaluate the L-PLA-coated stent. Absorption was measured using a radioisotope technique after preparing the mAb-incorporated stent, and the absorption curve was determined from the absorption data. In an in vitro perfusion circuit, the antibody was eluted from the stent matrices, and the related influence factors were evaluated based on the release data.


Sujets)
Humains , Absorption , Alliages , Chimie , Anticorps monoclonaux , Chimie , Allergie et immunologie , Endoprothèses à élution de substances , Occlusion du greffon vasculaire , Allergie et immunologie , Acide lactique , Chimie , Antiagrégants plaquettaires , Chimie , Allergie et immunologie , Complexe glycoprotéique IIb-IIIa de la membrane plaquettaire , Allergie et immunologie , Polymères , Chimie , Facteurs temps
SÉLECTION CITATIONS
Détails de la recherche